Pasar al contenido principal

DESARROLLO DE UNA HERRAMIENTA COMPUTACIONAL PARA LA PLANIFICACION QUIRURGICA DEL SISTEMA RESPIRATORIO: APLICACION AL DISEÑO DE UN NUEVO STENT BIODEGRADABLE PARA VIAS AEREAS

PID2021-125731OB-C31

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2021
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD PUBLICA DE NAVARRA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 10
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Impact of geometric and hemodynamic changes on a mechanobiological model of atherosclerosis

  • Hernández-López, Patricia
  • Cilla, Myriam
  • Martínez, Miguel Á.
  • Peña, Estefanía
  • Malvè, Mauro
Background and Objective: In this work, the analysis of the importance of hemodynamic updates on a mechanobiological model of atheroma plaque formation is proposed. Methods: For that, we use an idealized and axisymmetric model of carotid artery. In addition, the behavior of endothelial cells depending on hemodynamical changes is analyzed too. A total of three computational simulations are carried out and their results are compared: an uncoupled model and two models that consider the opposite behavior of endothelial cells caused by hemodynamic changes. The model considers transient blood flow using the Navier–Stokes equation. Plasma flow across the endothelium is determined with Darcy’s law and the Kedem–Katchalsky equations, considering the three-pore model, which is also employed for the flow of substances across the endothelium. The behavior of the considered substances in the arterial wall is modeled with convection–diffusion–reaction equations, and the arterial wall is modeled as a hyperelastic Yeoh’s material. Results:Significant variations are noted in both the morphology and stenosis ratio of the plaques when comparing the uncoupled model to the two models incorporating updates for geometry and hemodynamic stimuli. Besides, the phenomenon of double-stenosis is naturally reproduced in the models that consider both geometric and hemodynamical changes due to plaque growth, whereas it cannot be predicted in the uncoupled model. Conclusions: The findings indicate that integrating the plaque growth model with geometric and hemodynamic settings is essential in determining the ultimate shape and dimensions of the carotid plaque.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Old crimes reported in new bottles: the disclosure of child sexual abuse on Twitter through the case #MeTooInceste

  • Aguerri, Jesús C.
  • Molnar, Lorena
  • Miró-Llinares, Fernando
Movements such as #MeToo have shown how an online trend can become the vehicle for collectively sharing personal experiences of sexual victimisation that often remains unreported to the criminal justice system. These social media trends offer new opportunities to social scientists who investigate complex phenomena that, despite existing since time immemorial, are still taboo and difficult to access. They also bring technical difficulties, as the challenge to identify reports of victimisation, and new questions about the characteristic of the events, the role that victimisation testimonies play and the capacity to detect them by analysing their characteristics. To address these issues, we collected 91,501 tweets under the hashtag #MeTooInceste, posted from the 20 to 27 January 2021. A model was fitted using Latent Dirichlet Allocation that detected 1688 tweets disclosing experiences of child sexual abuse, with an accuracy of 91.3% [± 3%] and a recall of 93.1% [± 5%]. We performed Conjunctive Analysis of Case Configurations on the tweets identified as disclosures of victimisation and found that long tweets posted by users with small accounts, without URL or picture, were more likely to be related to disclosure of child sexual abuse. We discuss the possibilities of these trends and techniques offer for research and practice.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Computational fluid dynamics comparison of the upper airway velocity, pressure, and resistance in cats using an endotracheal tube or a supraglottic airway device

  • Zamora-Perarnau, Carla
  • Malvè, Mauro
  • Fernández-Parra, Rocío
Intoduction: In veterinary medicine, airway management of cats under general anesthesia is performed with an endotracheal tube (ETT) or supraglottic airway device (SGAD). This study aims to describe the use of computational fluid dynamics (CFD) to assess the velocities, pressures, and resistances of cats with ETT or SGAD. Methods: A geometrical reconstruction model of the device, trachea, and lobar bronchi was carried out from computed tomography (CT) scans that include the head, neck, and thorax. Twenty CT scans of cats under general anesthesia using ETT (n = 10) and SGAD (n = 10) were modeled and analyzed. An inspiratory flow of 2.4 L/min was imposed in each model and velocity (m/s), general and regional pressures (cmH2O) were computed. General resistance (cmH2O/L/min) was calculated using differential pressure differences between the device inlet and lobar bronchi. Additionally, regional resistances were calculated at the device¿s connection with the breathing circuit (region A), at the glottis area for the SGAD, and the area of the ETT exit (bevel) (region B) and the device itself (region C). Results: Recirculatory flow and high velocities were found at the ETT¿s bevel and at the glottis level in the SGAD group. The pressure gradient (¿p) was more enhanced in the ETT cases compared with the SGAD cases, where the pressure change was drastic. In region A, the ¿p was higher in the ETT group, while in regions B and C, it was higher in the SGAD group. The general resistance was not statistically significant between groups (p = 0.48). Higher resistances were found at the region A (p = <0.001) in the ETT group. In contrast, the resistance was higher in the SGAD cases at the region B (p = 0.001). Discussion: Overall, the provided CT-based CFD analysis demonstrated regional changes in airway pressure and resistance between ETT and SGAD during anesthetic flow conditions. Correct selection of the airway device size is recommended to avoid upper airway obstruction or changes in flow parameters., MM and RF-P are supported by the grants PID2021-125731OB-C31 and PID2021-125731OB-C33, respectively, which are financed by the Spanish Ministry of Science and Innovation MCIN/AEI/10.13039/501100011033/ and FEDER ('A way to build Europe').
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Nasal anatomy and sniffing in respiration and olfaction of wild and domestic animals

  • Xi, Jinxiang
  • Si, Xiuhua April
  • Malvè, Mauro
Animals have been widely utilized as surrogate models for humans in exposure testing, infectious disease experiments, and immunology studies. However, respiratory diseases affect both humans and animals. These disorders can spontaneously affect wild and domestic animals, impacting their quality and quantity of life. The origin of such responses can primarily be traced back to the pathogens deposited in the respiratory tract. There is a lack of understanding of the transport and deposition of respirable particulate matter (bio-aerosols or viruses) in either wild or domestic animals. Moreover, local dosimetry is more relevant than the total or regionally averaged doses in assessing exposure risks or therapeutic outcomes. An accurate prediction of the total and local dosimetry is the crucial first step to quantifying the dose-response relationship, which in turn necessitates detailed knowledge of animals' respiratory tract and flow/aerosol dynamics within it. In this review, we examined the nasal anatomy and physiology (i.e., structure-function relationship) of different animals, including the dog, rat, rabbit, deer, rhombus monkey, cat, and other domestic and wild animals. Special attention was paid to the similarities and differences in the vestibular, respiratory, and olfactory regions among different species. The ventilation airflow and behaviors of inhaled aerosols were described as pertinent to the animals' mechanisms for ventilation modulation and olfaction enhancement. In particular, sniffing, a breathing maneuver that animals often practice enhancing olfaction, was examined in detail in different animals. Animal models used in COVID-19 research were discussed. The advances and challenges of using numerical modeling in place of animal studies were discussed. The application of this technique in animals is relevant for bidirectional improvements in animal and human health., The author MM is supported by grant PID2021-125731OB-C31 from the Spanish Ministry of Science and Innovation MCIN/AEI/10.13039/501100011033/and FEDER (A way to build Europe).
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Computational analysis of polymeric biodegradable and customizable airway stent designs

  • Ayechu Abendaño, Ada
  • Pérez-Jiménez, Aurora
  • Sánchez-Matás, Carmen
  • López-Villalobos, José Luis
  • Díaz Jiménez, Cristina
  • Fernández-Parra, Rocío
  • Malvè, Mauro
The placement of endotracheal prostheses is a procedure used to treat tracheal lesions when no other surgical options are available. Unfortunately, this technique remains controversial. Both silicon and metallic stents are used with unpredictable success rates, as they have advantages but also disadvantages. Typical side effects include restenosis due to epithelial hyperplasia, obstruction and granuloma formation. Repeat interventions are often required. Biodegradable stents are promising in the field of cardiovascular biomechanics but are not yet approved for use in the respiratory system. The aim of the present study is to summarize important information and to evaluate the role of different geometrical features for the fabrication of a new tracheo-bronchial prosthesis prototype, which should be biodegradable, adaptable to the patient’s lesion and producible by 3D printing. A parametric design and subsequent computational analysis using the finite element method is carried out. Two different stent designs are parameterized and analyzed. The biodegradable material chosen for simulations is polylactic acid. Experimental tests are conducted for assessing its mechanical properties. The role of the key design parameters on the radial force of the biodegradable prosthesis is investigated. The computational results allow us to elucidate the role of the pitch angle, the wire thickness and the number of cells or units, among other parameters, on the radial force. This work may be useful for the design of ad hoc airway stents according to the patient and type of lesion., This study is financed by grants PID2021-125731OB-C31, PID2021-125731OB-C32 and PID2021-125731OB-C33 from MCIN/AEI/10.13039/501100011033/ and FEDER 'A way to build Europe'.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Effect of annealing on the mechanical properties of composites of PLA mixed with Mg and with HA

  • Sánchez González, Carmen
  • Pérez Jiménez, Aurora Fernanda
  • Malvè, Mauro
  • Díaz Jiménez, Cristina
Polylactic acid (PLA) is a bioresorbable and biocompatible material and is a promising alternative to the current materials used for permanent implants as it has osteosynthesis properties. However, this material has some drawbacks due to its low mechanical and thermal resistance after 3D printing. Extensive research has been conducted to improve the properties of this material, for example, with the addition of other compounds, such as magnesium (Mg) or Hydroxyapatite (HA). These reinforced materials have been shown to reduce the internal stress of the matrix of PLA, improving the thermal, optical and structural properties of the material, even though the performance achieved is lower than needed to be implanted. In addition, although it is known that the addition of Mg or HA affects the mechanical performance of the material, mechanical properties have not been studied in the literature. Thus, the aim of this study is to research the effect of thermal post-processing based on annealing of composites made of PLA with Mg and PLA with HA, manufactured by fused filament fabrication, with the goal of finding an improvement in the mechanical properties of these materials. As a result, different designs of annealing processes have been studied with different reinforced materials and their mechanical properties have been compared, studying axial traction and compression, radial compression as well as flexibility, among others. The comparative results achieved show the relevance of the design of the annealing process for the improvement of the mechanical properties of these materials., This study is financed by grants PID2021-125731OB-C31 and PID2021-125731OB-C32 from MCIN/AEI/10.13039/501100011033/ and CER-20231013 from Cervera.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Impact of geometric and hemodynamic changes on a mechanobiological model of atherosclerosis

  • Hernández-López, Patricia
  • Cilla, Myriam
  • Martínez, Miguel Ángel
  • Peña, Estefanía
  • Malvè, Mauro
Background and objective: in this work, the analysis of the importance of hemodynamic updates on a mechanobiological model of atheroma plaque formation is proposed. Methods: for that, we use an idealized and axisymmetric model of carotid artery. In addition, the behavior of endothelial cells depending on hemodynamical changes is analyzed too. A total of three computational simulations are carried out and their results are compared: an uncoupled model and two models that consider the opposite behavior of endothelial cells caused by hemodynamic changes. The model considers transient blood flow using the Navier-Stokes equation. Plasma flow across the endothelium is determined with Darcy's law and the Kedem-Katchalsky equations, considering the three-pore model, which is also employed for the flow of substances across the endothelium. The behavior of the considered substances in the arterial wall is modeled with convection¿diffusion¿reaction equations, and the arterial wall is modeled as a hyperelastic Yeoh's material. Results: significant variations are noted in both the morphology and stenosis ratio of the plaques when comparing the uncoupled model to the two models incorporating updates for geometry and hemodynamic stimuli. Besides, the phenomenon of double-stenosis is naturally reproduced in the models that consider both geometric and hemodynamical changes due to plaque growth, whereas it cannot be predicted in the uncoupled model. Conclusions: the findings indicate that integrating the plaque growth model with geometric and hemodynamic settings is essential in determining the ultimate shape and dimensions of the carotid plaque., Support was obtained from the Spanish Ministry of Science and Technology through the research projects PID2019-107517RB-I00 and PID2022-140219OB-I00 and financial support to P. Hernández-López from the grant BES-2017-080239, and the regional Government of Aragón support for the funding of the research project T24-20R. Myriam Cilla is supported by Grant Ramón Cajal grant 171562 funded by MICIU/AEI/ 10.13039/501100011033 and the European Social Fund Plus (FSE+) . M. Malvé is supported by grant PID2021-125731OB-C31 from the Spanish Ministry of Science and Innovation MCIN/AEI/10.13039/501100011033/ and FEDER ("Away to build Europe").; The authors thank the research support from the CIBER initiative, whose actions are financed by the Instituto de Salud Carlos III with assistance from the European Regional Development Fund .
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Salbutamol transport and deposition in healthy cat airways under different breathing conditions and particle sizes

  • Fernández-Parra, Rocío
  • Pey, Pascaline
  • Reinero, Carol
  • Malvè, Mauro
Salbutamol is a bronchodilatator commonly used for the treatment of feline inflammatory lower airway disease, including asthma or acute bronchospasm. As in humans, a pressurized metered dose inhaler (pMDI) is used in conjunction with a spacer and a spherical mask to facilitate salbutamol administration. However, efficacy of inhalation therapy is influenced by different factors including the noncooperative character of cats. In this study, the goal was to use computational fluid dynamics (CFD) to analyze the impact of breathing patterns and salbutamol particle size on overall drug transport and deposition using a specific spherical mask and spacer designed for cats. A model incorporating three-dimensional cat airway geometry, a commercially available spherical mask, and a 10  cm spacer, was used for CFD analysis. Two peak inspiratory flows were tested: 30  mL/s and 126  mL/s. Simulations were performed with 30s breathing different inspiratory and expiratory times, respiratory frequencies and peaks. Droplet spray transport and deposition were simulated with different particle sizes typical of the drug delivery therapies (1, 5, 10, and 15  μm). The percentage of particle deposition into the device and upper airways decreased with increasing particle diameter during both flows imposed in this cat model. During increased mean ventilatory rate (MVR) conditions, most of the salbutamol was lost in the upper airways. And during decreased MVR conditions, most of the particles remained in suspension (still in hold-up) between the mask and the carina, indicating the need for more than 30  s to be transported. In both flows the percentage of particles traveling to the lung was low at 1.5%–2.3%. In conclusion, in contrast to what has been described in the human literature, the results from this feline model suggest that the percentage of particles deposited on the upper airway decreases with increasing particle diameter., This study is supported by grants PID2021-125731OB-C31 and PID2021-125731OB-C33 from the Spanish Ministry of Science and Innovation MCIN/AEI/10.13039/501100011033/ and FEDER (“A way to build Europe”).
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Numerical modelling of airflow and aerosol particle delivery in cats with bronchial and non-bronchial disease

  • Zamora-Perarnau, Carla
  • Malvè, Mauro
  • Fernández-Parra, Rocío
Feline lower airway disease comprises a spectrum of inflammatory conditions, including asthma, which is commonly treated with inhaled glucocorticoids. This study employs computed tomography (CT)–based computational fluid dynamics (CFD) models to characterize airflow dynamics in feline lower airways with and without bronchial disease (BD and NBD), evaluating velocity, pressure, wall shear stress, and airway resistance under different flow conditions. In addition, deposition patterns of two aerosol particle sizes (1 µm and 10 µm) were assessed within the trachea and bronchi. Geometrical reconstructions of the trachea and lobar bronchi were generated from CT scans of 24 cats, classified into BD and NBD groups. Simulations were performed using two airflow conditions and two particle diameters. Airflow parameters and aerosol particle deposition were calculated for each model. A trend toward higher values of most airflow parameters was observed in the NBD group, except for expiratory resistance and velocity. However, no statistically significant differences in airflow parameters were identified between groups. Particle deposition analysis showed a higher deposition fraction for larger particles, with 10 µm particles depositing more frequently on bronchial walls than 1 µm particles in both groups. Overall, CT-based CFD analysis revealed no significant group differences in resistance, pressure, wall shear stress, or velocity. Nevertheless, particle size influenced deposition patterns, with larger particles showing increased bronchial trapping. Although the initial hypothesis was not confirmed, this feasibility and characterization study establishes a methodological framework for future in silico investigations of feline lower airway disease providing preliminary physiologically and clinically relevant insights., This study is supported by grants PID2021-125731OB-C31 and PID2021-125731OB-C33 from the Spanish Ministry of Science and Innovation MCIN/ AEI/10.13039/501100011033/ and FEDER ('A way to build Europe').
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Influence of material selection on the mechanical properties of 3D-printed tracheal stents for surgical applications

  • Pérez Jiménez, Aurora Fernanda
  • Sánchez González, Carmen
  • Pérez Teresí, Sandra
  • Landa, Noelia
  • Díaz Jiménez, Cristina
  • Malvè, Mauro
Endotracheal prosthesis placement is employed as a therapeutic intervention for tracheal lesions in cases where conventional surgical approaches are not feasible. The learning curve for endotracheal stent placement can vary depending on the type of stent, the training environment, and the clinician's prior experience; however, it is generally considered moderately complex. Inadequate practice can have serious consequences, as the procedure involves a critical area such as the airway. The main risks and complications associated with inadequate technique or improper execution can include stent migration, formation of granulation tissue or hyperplasia, tracheal or pulmonary infection, obstruction or fracture of the stent, hemorrhage and tracheal perforation, among others. The purpose of the present study is to summarize important information and evaluate the role of different material features in the 3D printing manufacturing of an appropriate tracheobronchial medical device, which should be as appropriate as possible to facilitate placement during surgical practice. A complex stent design was fabricated using three different biodegradable materials, polycaprolactone (PCL), polydioxanone (PDO), and polymer blend of polylactic acid/polycaprolactone (PLA/PCL), through additive manufacturing, specifically fused filament fabrication (FFF)3D printing. Parameter optimization of the 3D printing process was required for each material to achieve an adequate geometric quality of the stent. Experimental analyses were conducted to characterize the mechanical properties of the printed stents. Flexural strength and radial compression resistance were evaluated, with particular emphasis on radial force due to its clinical relevance in preventing collapse after implantation in the trachea. The results provide valuable insights into how material selection could influence device behavior during placement to support surgical requirements., This research was financed by the grants PID2021-125731OB-C31 and PID2021-125731OB-C32 from the Spanish Ministry of Science and Innovation (MCIN), Agencia Estatal de Investigación (AEI) -- grant number 10.13039/501100011033, and by grant CER-20231013 from the Cervera Programme.