Analysis of the accuracy on computing nominal stress in a biaxial test for arteries

  • Cilla, Miryam
  • Corral, A.V.
  • Peña Baquedano, Juan Antonio
  • Peña Baquedano Estefania
Biaxial tests are commonly used to investigate the mechanical behaviour of anisotropic soft biological tissues such as cardiovascular tissues. However, there is still no clear understanding of the influence that the biaxial test set-up conditions may have on the computing material stress of the experimental results. The aim of the present study is to further investigate the accuracy of calculated material stress from measured force during biaxial tests using finite element methods (FEM). The biaxial mechanical response of ascending aorta and pulmonary artery tissue samples was obtained by FEM simulation under two different gripping methods: (a) a system with noodle clamps and (b) a clamped system with needles which leave the specimen's edges free to expand laterally. The results show that the clamped method whose joints allow free movement in the lateral direction produces stresses closer to the universally accepted formulation of biaxial material stress in the central region. However, the system with noodle clamps, commonly used to grip the sample, produces an alteration of the measurement stresses. Our simulations show results giving an inaccurate estimation of the stress at the centre of the sample. In some cases, the stresses are overestimated and in others underestimated depending on the anisotropy of the sample. We can conclude that the clamped system with needles which leave the specimen's edges free to expand laterally should be used as an efficient methodology to other commonly used gripping methods for biological tissues with anisotropic materials.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Influence of vessel curvature and plaque composition on drug transport in the arterial wall following drug-eluting stent implantation

  • Escuer, J.
  • Aznar, I.
  • McCormick, C.
  • Peña, E.
  • McGinty, S.
  • Martínez, M.A.
In the last decade, many computational models have been developed to describe the transport of drug eluted from stents and the subsequent uptake into arterial tissue. Each of these models has its own set of limitations: for example, models typically employ simplified stent and arterial geometries, some models assume a homogeneous arterial wall, and others neglect the influence of blood flow and plasma filtration on the drug transport process. In this study, we focus on two common limitations. Specifically, we provide a comprehensive investigation of the influence of arterial curvature and plaque composition on drug transport in the arterial wall following drug-eluting stent implantation. The arterial wall is considered as a three-layered structure including the subendothelial space, the media and the adventitia, with porous membranes separating them (endothelium, internal and external elastic lamina). Blood flow is modelled by the Navier–Stokes equations, while Darcy’s law is used to calculate plasma filtration through the porous layers. Our findings demonstrate that arterial curvature and plaque composition have important influences on the spatiotemporal distribution of drug, with potential implications in terms of effectiveness of the treatment. Since the majority of computational models tend to neglect these features, these models are likely to be under- or over-estimating drug uptake and redistribution in arterial tissue.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Unraveling the multilayer mechanical response of aorta using layer-specific residual stresses and experimental properties

  • Díaz, C.
  • Peña, J. A.
  • Martínez, M. A.
  • Peña, E.
To test the capability of the multilayer model, we used previously published layer-specific experimental data relating to the axial pre-stretch, the opening angle, the fiber distribution obtained by polarized light microscopy measurements, and the uniaxial and biaxial response of the porcine descending and abdominal aorta. We fitted the mechanical behavior of each arterial layer using Gasser, Holzapfel and Ogden strain energy function using the dispersion parameter ¿ as phenomenological parameter obtained during the fitting procedure or computed from the experimental fiber distribution. A multilayer finite element model of the whole aorta with the dimensions of the circumferential and longitudinal strips were then built using layer-specific material parameters previously fitted. This model was used to capture the whole aorta response under uniaxial and biaxial stress states and to reproduce the response of the whole aorta to internal pressure. Our results show that a model based on a multilayer structure without residual stresses is unable to render the uniaxial and biaxial mechanical response of the aorta (R2=0.6954 and R2=0.8582 for descending thoracic aorta (DTA) and infrarenal abdominal aorta (IAA), respectively). Only an appropriate multilayer model that includes layer-specific residual stresses can reproduce the response of the whole aorta (R2=0.9787 and R2=0.9636 for DTA and IAA respectively). In addition, a multilayer model without residual stresses produces the same stress distribution as a monolayer model without residual stresses where the maximal value of circumferential and longitudinal stresses appears at the inner radius of the intima. Finally, if layer-specific residual stresses are not available, there is less error the stress distribution using a monolayer model with residual stresses that a multilayer model without residual stresses.