Therapeutic Electrical Stimulation for Regenerative Medicine Application: A Need for a Credible In Vitro Model System

  • Mobini, Sahba
Trabajo presentado en la 30th Annual Conference of the European Society for Biomaterials (ESB-2019), celebrada en Dresden (Alemania), del 9 al 13 de septiembre de 2019, Introduction Endogenous electric field (bioelectric field) is an electrical potential difference resulting from charge flow (current) in the body at all levels (i.e., cell, tissue, and organ), which is found to be essential in a variety of important biological process, such as healing and development 1 .Recent studies showed that manipulation of intrinsic bioelectric fields can cause disease or be used as therapeutics 2-4. Among the wide range of bioelectric fields, steady, long-lasting direct current (≈ 100 μA/cm2 ), also known as current of injury, generates a voltage gradient (≈ 10-100 mV/mm) between intact section and injured site that has regenerative effect and can change cell faith and responses. Experimental Methods We treated different cell types with low voltage electrical stimulation, within an invitro system, and induced different responses, such as differentiation, alignment, viability and proliferation (Figure 1). Results and Discussion These results suggest that electrical stimulation (ES), as a drug-free, cell-free approach, could be an attractive alternative for biochemical remedies and cell therapy approaches for tissue regeneration and wound healing. However, ES has not been widely accepted as a clinical treatment and it is only used as an adjunctive therapy. This is due to the lack of consistency in major outcomes, absence of coherency in defining ES protocols, and unmatchable results in vitro and in vivo. Moreover, there is inadequate understanding of the dominant mechanism of ES and leading parameters triggering the molecular cascades and generate the main changes in cellular level. Conclusion Here, I will discuss: 1) the current state-of-the-art on ES in vitro and in vivo and the common hypothesis on molecular mechanisms involved; 2) the confusions associated with protocols in vitro and in vivo and the incapability of the current devices to address remaining challenges; 3) the approaches intended to develop credible vitro models to provide a standard methodology for exploring ES to induce regeneration responses in tissues such as bone and nerves; 4) the future perspective including the incorporation of modern biomaterials (e.g., conductive nanomaterials, and polymers) and electronics., H2020-Marie Skłodowska Curie-Individual Fellowship currently supports this project (NeuPES ID:793102).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Metallic Nanostructured Electrodes for in vivo and in vitro Electrical Stimulation

  • Mobini, Sahba
  • González Sagardoy, María Ujué
  • Caballero-Calero, Olga
  • Patrick, Erin E.
  • Martín-González, Marisol
  • García Martínez, Jorge Manuel
  • García-Martín, José Miguel
Trabajo presentado en la 31st Annual Conference of the European Society for Biomaterials, celebrada virtualmente del 5 al 9 de septiembre de 2021, The use of electricity in interaction with biological systems for therapeutic and diagnostic purposes become a prominent research topic. Electrodes are key components of electrical stimulation and recording devices for in vivo and in vitro usages. Bioelectrodes should present excellent electroconductivity to be able to transfer the electrical current efficiently (charge mobility inside the device). Moreover, they need to provide excellent electroactivity to convert electronic current to ionic current at the electrode/extracellular fluid (ECF) interphase. The use of nanostructures in fabrication of bioelectrodes is beneficial, since nanostructures offer superior effective surface area that decreases impedance (Z) and increases charge storage capacity (CSC) of the electrodes. Low Z prevents irreversible faradic reactions that are harmful for biological systems (safe stimulation), and decreases thermal noises that interfere recording bioelectrical signals. Higher CSC ensures effective charge transfer (effective stimulation)1. Here we developed highly pure metallic nanostructured electrodes from Ti, Au and Pt and characterized their electrochemical properties. Electrical stimulation (ES) modes for both in vitro and in vivo applications were simulated. Finally, we present the design of an in vitro ES platform incorporating nanostructured electrodes.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Miniaturized In Vitro Electrical Stimulation Platform

  • Mobini, Sahba
  • González Sagardoy, María Ujué
  • García Martínez, Jorge Manuel
  • García-Martín, José Miguel
Resumen del trabajo presentado en la 31st Annual Conference of the European Society for Biomaterials, celebrada virtualmente del 5 al 9 de septiembre de 2021, Bioelectricity facilitates sending and receiving information to/from the body to provide controlling and feedbacking ºystems to regulate, and monitor biological microenvironment. Also, numerous studies showed electrical stimulation (ES) promotes proliferation, migration and secretion of pro-regenerative factors in the cells and accelerates tissue regeneration, and wound healing. Moreover, ES has a great potential to be adapted as a digital medicine and/or smart therapeutic. Growing research on the use of ES in biological systems, promotes development of in vitro platforms to study the role and applications of ES in contact with cells and tissues. Up to now several in vitro ES devices has been established, such as: devices for measuring electrical impedance of cells that is used to evaluate specific biological activities; devices for inducing specific cell responses by means of low voltage ES (e.g., cell migration, differentiation); devices for stimulating and/or recording electrical activity of electroactive cells in CMOS-based multi-electrode arrays (MEAs) and/or multipurpose setups such as lab-on-the-chip. Nevertheless, quality of electrical signals, reproducibility of experiments, increasing of throughput and accuracy of performance of current in vitro platforms are yet to be improved. We believe, advances in biomaterials technology, computational modelling, microelectronics, microfabrication, and electrochemistry have opened new doors to meet these needs. Here we present the evolution of in vitro platforms for electrical stimulation and recording for different proposes and introduce our innovative device for low voltage direct electrical stimulation. We discussed design, fabrication and characterization of this platform and its benefits for conducting high throughput and controlled experiments within a standard cell culture vessel.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Reactive Accelerated Aging Test, A Time Machine to Evaluate the Durability of Biomaterials for Neural Implants

  • Limones-Ahijón, Blanca
  • García-Martín, José Miguel
  • González Sagardoy, María Ujué
  • Mobini, Sahba
Resumen del trabajo presentado en la 31st Annual Conference of the European Society for Biomaterials, celebrada virtualmente del 5 al 9 de septiembre de 2021, Neural implants are increasingly investigated to assist patients with defects or pathologies in nervous system. There is a growing research about developing new biomaterials to improve the effectiveness and biocompatibility of neural implants. For example, inflammatory responses to implantation of these devices, also called foreign body reactions (FBR), are still a challenge for their performance. During FBR, immune cells such as monocytes and macrophages are recruited and activated, leading to several consequences. One of those is the increased amount of reactive oxygen species (ROS) due to differentiation and phagocytosis of macrophages. ROS affects the performance of neural implants in the long-term by increasing corrosion and delamination. Reactive accelerated aging tests (RAAT) are used as a tool to test the durability of bioelectrodes and neural implants, mimicking the presence of ROS in vivo. In RAAT, an H2O2 solution with high temperature can mimic several years of implantation during a few weeks due to the increased reaction rate provided by temperature. A RAAT protocol for testing neural implants has been recently approved by FDA. In this work, we have built a RAAT setup based on this protocol. We have studied different parameters that affect the stability of the system and we have employed RAAT to analyse the durability of different flat and nanostructured metallic layers.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Effects of nanostructuration on the electrochemical performance of metallic bioelectrodes

  • Mobini, Sahba
  • González Sagardoy, María Ujué
  • Caballero-Calero, Olga
  • Patrick, Erin E.
  • Martín-González, Marisol
  • García-Martín, José Miguel
The use of metallic nanostructures in the fabrication of bioelectrodes (e.g., neural implants) is gaining attention nowadays. Nanostructures provide increased surface area that might benefit the performance of bioelectrodes. However, there is a need for comprehensive studies that assess electrochemical performance of nanostructured surfaces in physiological and relevant working conditions. Here, we introduce a versatile scalable fabrication method based on magnetron sputtering to develop analogous metallic nanocolumnar structures (NCs) and thin films (TFs) from Ti, Au, and Pt. We show that NCs contribute significantly to reduce the impedance of metallic surfaces. Charge storage capacity of Pt NCs is remarkably higher than that of Pt TFs and that of the other metals in both morphologies. Circuit simulations of the electrode/electrolyte interface show that the signal delivered in voltage-controlled systems is less filtered when nanocolumns are used. In a current-controlled system, simulation shows that NCs provide safer stimulation conditions compared to TFs. We have assessed the durability of NCs and TFs for potential use in vivo by reactive accelerated aging test, mimicking one-year in vivo implantation. Although each metal/morphology reveals a unique response to aging, NCs show overall more stable electrochemical properties compared to TFs in spite of their porous structure., This work was supported by European Commission (Ref. 793102-NeuPES-H2020-MSCA-IF-2017), Comunidad de Madrid (Atracción de Talento Programme, Modalidad-1 Ref. 2019-T1/ IND-1335), and CSIC (ILINK+2020 Ref. LINKA20342). The authors would also like to acknowledge the service from the MiNa Laboratory at IMN, funded from CM (project SpaceTec, S2018/NMT-4291 TEC2SPACE), MINECO (project CSIC13- 4E-1794), and EU (FEDER, FSE). O. C–C and M. M-G would like to acknowledge financial support from project MAT2017- 86450-c4-3-r., Peer reviewed