Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Medical applications of ionizing radiation and radiation protection for European patients, population and environment

  • Thierry-Chef, Isabelle
  • Cardis, Elisabeth
  • Damilakis, John
  • Frija, Guy
  • Hierath, Monika
  • Hoeschen, Christop
  • EURAMED ROCC-N-ROLL consortia members
Medical applications of ionising radiation (IR) represent a key component of the diagnosis and treatment of many diseases, guaranteeing efficient health care. The use of IR in medicine, the largest source of general population radiation exposure, is potentially associated with increased risk of cancer and non-cancer diseases, which needs to be evaluated to provide evidence-based input for risk-benefit considerations. Efforts are also needed to improve the safety and efficacy of medical applications through optimisation. The EC Euratom programme enhances research in medical radiation protection. The four complementary multidisciplinary projects presented here contribute to (1) improving knowledge on exposure and effects of diagnostic and therapeutic applications and (2) transferring results into clinical practice. The common aim is to optimise use for individual patients, enhance education and training, ensuring adherence to ethical standards, particularly related to technologies based on artificial intelligence. MEDIRAD, SINFONIA and HARMONIC focus on improving exposure estimation and studying the detrimental effects of diagnostic and therapeutic medical exposures in patients and staff using different endpoints. EURAMED rocc-n-roll brings together the results of the projects and the recommendations generated by them to build, in collaboration with the EU Radiation Protection research platforms, a strategic research agenda and a roadmap for research priorities., The HARMONIC project has received funding from the Euratom research and training programme 2014–2018 under grant agreement No. 847707. The MEDIRAD project has received funding from Euratom’s research and innovation programme 2014–2018 under grant agreement No. 755523. The SINFONIA project has received funding from the Euratom research and training programme 2019–2020 under grant agreement No. 945196. The EURAMED ROCC-N-ROLL project has received funding from the Euratom research and training programme 2019–2020 under grant agreement No 899995. ISGlobal also acknowledges support from the Spanish Ministry of Science, Innovation and Universities through the “Centro de Excelencia Severo Ochoa 2019–2023” Program (CEX2018-000806-S), support from the Generalitat de Catalunya through the CERCA Program and support from the Secretariat of Universities and Research of the Department of Business and Knowledge of the Generalitat of Catalonia through AGAUR (the Catalan Agency for Management of University and Research Grants) (Project 2017 SGR 1487).
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Health effects of ionising radiation in paediatrics undergoing either cardiac fluoroscopy or modern radiotherapy (The HARMONIC project)

  • Thierry-Chef, Isabelle
  • Sarukhan, Adelaida
  • Ortiz, Rodney
  • Chumak, Vadim
The use of ionising radiation (IR) for medical diagnosis and treatment procedures has had a major impact on the survival of paediatric patients. Although the benefits of these techniques lead to efficient health care, evaluation of potential associated long-term health effects is required. HARMONIC aims to better understand the increased risk of cancer and non-cancer effects after exposure to medical IR in children with cancer treated with modern external beam radiotherapy (EBRT) – radiation energy in MeV range – and in children with cardiac defects diagnosed and treated with cardiac fluoroscopy procedures (CFP) – radiation energy in keV range. The project investigates, among survivors of paediatric cancer, potential endocrine dysfunction, cardiovascular and neurovascular damage, health-related quality of life and second (and subsequent) primary cancer (SPC). The cardiac component builds a pooled cohort of approximately 90 000 paediatric patients who underwent CFP during childhood and adolescence to investigate cancer risk following exposure to IR and explore the potential effects of conditions predisposing to cancer. HARMONIC develops software tools to allow dose reconstruction in both EBRT and CFP to enable epidemiological investigations and future optimisation of treatments. With the creation of a biobank of blood and saliva samples, HARMONIC aims to provide a mechanistic understanding of radiation-induced adverse health effects and identify potential biomarkers that can predict these effects., The HARMONIC project has received funding from the Euratom research and training programme 2014–2018 under grant agreement No. 847707.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Experimental validation of an analytical program and a Monte Carlo simulation for the computation of the far out-of-field dose in external beam photon therapy applied to pediatric patients

  • De Saint-Hubert, Marijke
  • Suesselbeck, Finja
  • Vasi, Fabiano
  • Stuckmann, Florian
  • Rodriguez, Miguel
  • Dabin, Jérémie
  • Timmermann, Beate
  • Thierry-Chef, Isabelle
  • Schneider, Uwe
  • Brualla, Lorenzo
Background: The out-of-the-field absorbed dose affects the probability of primary second radiation-induced cancers. This is particularly relevant in the case of pediatric treatments. There are currently no methods employed in the clinical routine for the computation of dose distributions from stray radiation in radiotherapy. To overcome this limitation in the framework of conventional teletherapy with photon beams, two computational tools have been developed-one based on an analytical approach and another depending on a fast Monte Carlo algorithm. The purpose of this work is to evaluate the accuracy of these approaches by comparison with experimental data obtained from anthropomorphic phantom irradiations. Materials and methods: An anthropomorphic phantom representing a 5-year-old child (ATOM, CIRS) was irradiated considering a brain tumor using a Varian TrueBeam linac. Two treatments for the same planned target volume (PTV) were considered, namely, intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). In all cases, the irradiation was conducted with a 6-MV energy beam using the flattening filter for a prescribed dose of 3.6 Gy to the PTV. The phantom had natLiF : Mg, Cu, P (MCP-N) thermoluminescent dosimeters (TLDs) in its 180 holes. The uncertainty of the experimental data was around 20%, which was mostly attributed to the MCP-N energy dependence. To calculate the out-of-field dose, an analytical algorithm was implemented to be run from a Varian Eclipse TPS. This algorithm considers that all anatomical structures are filled with water, with the exception of the lungs which are made of air. The fast Monte Carlo code dose planning method was also used for computing the out-of-field dose. It was executed from the dose verification system PRIMO using a phase-space file containing 3x109 histories, reaching an average standard statistical uncertainty of less than 0.2% (coverage factor k = 1 ) on all voxels scoring more than 50% of the maximum dose. The standard statistical uncertainty of out-of-field voxels in the Monte Carlo simulation did not exceed 5%. For the Monte Carlo simulation the actual chemical composition of the materials used in ATOM, as provided by the manufacturer, was employed. Results: In the out-of-the-field region, the absorbed dose was on average four orders of magnitude lower than the dose at the PTV. For the two modalities employed, the discrepancy between the central values of the TLDs located in the out-of-the-field region and the corresponding positions in the analytic model were in general less than 40%. The discrepancy in the lung doses was more pronounced for IMRT. The same comparison between the experimental and the Monte Carlo data yielded differences which are, in general, smaller than 20%. It was observed that the VMAT irradiation produces the smallest out-of-the-field dose when compared to IMRT. Conclusions: The proposed computational methods for the routine calculation of the out-of-the-field dose produce results that are similar, in most cases, with the experimental data. It has been experimentally found that the VMAT irradiation produces the smallest out-of-the-field dose when compared to IMRT for a given PTV., The presented research has been funded by the HARMONIC project. The HARMONIC project (Health effects of cArdiac fluoRoscopy and MOderN radIotherapy in paediatriCs) has received funding from the Euratom research and training programme 2014-2018 under grant agreement number 847707. MR acknowledges funding from the Sistema Nacional de Investigación de Panamá. ITC acknowledges support from the Spanish Ministry of Science and Innovation and State Research Agency through the “Centro de Excelencia Severo Ochoa 2019-2023” Program (CEX2018-000806-S) and support from the Generalitat de Catalunya through the CERCA Program.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Validation of a Monte Carlo framework for out-of-field dose calculations in proton therapy

  • De Saint-Hubert, Marijke
  • Verbeek, Nico
  • Bäumer, Christian
  • Esser, Johannes
  • Wulff, Jörg
  • Nabha, Racell
  • Van Hoey, Olivier
  • Dabin, Jérémie
  • Stuckmann, Florian
  • Vasi, Fabiano
  • Radonic, Stephan
  • Boissonnat, Guillaume
  • Schneider, Uwe
  • Rodriguez, Miguel
  • Timmermann, Beate
  • Thierry-Chef, Isabelle
  • Brualla, Lorenzo
Proton therapy enables to deliver highly conformed dose distributions owing to the characteristic Bragg peak and the finite range of protons. However, during proton therapy, secondary neutrons are created, which can travel long distances and deposit dose in out-of-field volumes. This out-of-field absorbed dose needs to be considered for radiation-induced secondary cancers, which are particularly relevant in the case of pediatric treatments. Unfortunately, no method exists in clinics for the computation of the out-of-field dose distributions in proton therapy. To help overcome this limitation, a computational tool has been developed based on the Monte Carlo code TOPAS. The purpose of this work is to evaluate the accuracy of this tool in comparison to experimental data obtained from an anthropomorphic phantom irradiation. An anthropomorphic phantom of a 5-year-old child (ATOM, CIRS) was irradiated for a brain tumor treatment in an IBA Proteus Plus facility using a pencil beam dedicated nozzle. The treatment consisted of three pencil beam scanning fields employing a lucite range shifter. Proton energies ranged from 100 to 165 MeV. A median dose of 50.4 Gy(RBE) with 1.8 Gy(RBE) per fraction was prescribed to the initial planning target volume (PTV), which was located in the cerebellum. Thermoluminescent detectors (TLDs), namely, Li-7-enriched LiF : Mg, Ti (MTS-7) type, were used to detect gamma radiation, which is produced by nuclear reactions, and secondary as well as recoil protons created out-of-field by secondary neutrons. Li-6-enriched LiF : Mg,Cu,P (MCP-6) was combined with Li-7-enriched MCP-7 to measure thermal neutrons. TLDs were calibrated in Co-60 and reported on absorbed dose in water per target dose (μGy/Gy) as well as thermal neutron dose equivalent per target dose (μSv/Gy). Additionally, bubble detectors for personal neutron dosimetry (BD-PND) were used for measuring neutrons (>50 keV), which were calibrated in a Cf-252 neutron beam to report on neutron dose equivalent dose data. The Monte Carlo code TOPAS (version 3.6) was run using a phase-space file containing 1010 histories reaching an average standard statistical uncertainty of less than 0.2% (coverage factor k = 1) on all voxels scoring more than 50% of the maximum dose. The primary beam was modeled following a Fermi-Eyges description of the spot envelope fitted to measurements. For the Monte Carlo simulation, the chemical composition of the tissues represented in ATOM was employed. The dose was tallied as dose-to-water, and data were normalized to the target dose (physical dose) to report on absorbed doses per target dose (mSv/Gy) or neutron dose equivalent per target dose (μSv/Gy), while also an estimate of the total organ dose was provided for a target dose of 50.4 Gy(RBE). Out-of-field doses showed absorbed doses that were 5 to 6 orders of magnitude lower than the target dose. The discrepancy between TLD data and the corresponding scored values in the Monte Carlo calculations involving proton and gamma contributions was on average 18%. The comparison between the neutron equivalent doses between the Monte Carlo simulation and the measured neutron doses was on average 8%. Organ dose calculations revealed the highest dose for the thyroid, which was 120 mSv, while other organ doses ranged from 18 mSv in the lungs to 0.6 mSv in the testes. The proposed computational method for routine calculation of the out-of-the-field dose in proton therapy produces results that are compatible with the experimental data and allow to calculate out-of-field organ doses during proton therapy., The presented research has been funded by the HARMONIC project. The HARMONIC project (Health effects of cArdiac fluoRoscopy and MOderN radIotherapy in paediatriCs) has received funding from the Euratom research and training program 2014-2018 under grant agreement No 847707. MR acknowledges funding from the Sistema Nacional de Investigación de Panamá. IT-C acknowledges support from the Spanish Ministry of Science and Innovation and State Research Agency through the “Centro de Excelencia Severo Ochoa 2019-2023” Program (CEX2018-000806-S) and support from the Generalitat de Catalunya through the CERCA Program.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Complete patient exposure during paediatric brain cancer treatment for photon and proton therapy techniques including imaging procedures

  • De Saint-Hubert, Marijke
  • Boissonnat, Guillaume
  • Schneider, Uwe
  • Bäumer, Christian
  • Verbeek, Nico
  • Esser, Johannes
  • Wulff, Jörg
  • Stuckmann, Florian
  • Suesselbeck, Finja
  • Nabha, Racell
  • Dabin, Jérémie
  • Vasi, Fabiano
  • Radonic, Stephan
  • Rodriguez, Miguel
  • Simon, Anne Catherine
  • Journy, Neige
  • Timmermann, Beate
  • Thierry-Chef, Isabelle
  • Brualla, Lorenzo
Background: In radiotherapy, especially when treating children, minimising exposure of healthy tissue can prevent the development of adverse outcomes, including second cancers. In this study we propose a validated Monte Carlo framework to evaluate the complete patient exposure during paediatric brain cancer treatment. Materials and methods: Organ doses were calculated for treatment of a diffuse midline glioma (50.4 Gy with 1.8 Gy per fraction) on a 5-year-old anthropomorphic phantom with 3D-conformal radiotherapy, intensity modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT) and intensity modulated pencil beam scanning (PBS) proton therapy. Doses from computed tomography (CT) for planning and on-board imaging for positioning (kV-cone beam CT and X-ray imaging) accounted for the estimate of the exposure of the patient including imaging therapeutic dose. For dose calculations we used validated Monte Carlo-based tools (PRIMO, TOPAS, PENELOPE), while lifetime attributable risk (LAR) was estimated from dose-response relationships for cancer induction, proposed by Schneider et al. Results: Out-of-field organ dose equivalent data of proton therapy are lower, with doses between 0.6 mSv (testes) and 120 mSv (thyroid), when compared to photon therapy revealing the highest out-of-field doses for IMRT ranging between 43 mSv (testes) and 575 mSv (thyroid). Dose delivered by CT ranged between 0.01 mSv (testes) and 72 mSv (scapula) while a single imaging positioning ranged between 2 μSv (testes) and 1.3 mSv (thyroid) for CBCT and 0.03 μSv (testes) and 48 μSv (scapula) for X-ray. Adding imaging dose from CT and daily CBCT to the therapeutic demonstrated an important contribution of imaging to the overall radiation burden in the course of treatment, which is subsequently used to predict the LAR, for selected organs. Conclusion: The complete patient exposure during paediatric brain cancer treatment was estimated by combining the results from different Monte Carlo-based dosimetry tools, showing that proton therapy allows significant reduction of the out-of-field doses and secondary cancer risk in selected organs., The presented research has been funded by the HARMONIC project. The HARMONIC project (Health effects of cArdiac fluoRoscopy and MOderN radIotherapy in paediatriCs) has received funding from the Euratom research and training programme 2014-2018 under grant agreement No 847707. IT-C acknowledges support from the Spanish Ministry of Science and Innovation and State Research Agency through the ‘Centro de Excelencia Severo Ochoa 2019-2023’ Program (CEX2018-000806-S), and support from the Generalitat de Catalunya through the CERCA Program.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

A Longitudinal Study of Individual Radiation Responses in Pediatric Patients Treated with Proton and Photon Radiotherapy, and Interventional Cardiology: Rationale and Research Protocol of the HARMONIC Project

  • Grazia Andreassi, María
  • Haddy, Nadia
  • Harms-Ringdahl, Mats
  • Campolo, Jonica
  • Borghini, Andrea
  • Chevalier, François
  • Schwenk, Jochen M.
  • Fresneau, Brice
  • Bolle, Stephanie
  • Fuentes, Manuel
  • Haghdoost, Siamak
The Health Effects of Cardiac Fluoroscopy and Modern Radiotherapy (photon and proton) in Pediatrics (HARMONIC) is a five-year project funded by the European Commission that aimed to improve the understanding of the long-term ionizing radiation (IR) risks for pediatric patients. In this paper, we provide a detailed overview of the rationale, design, and methods for the biological aspect of the project with objectives to provide a mechanistic understanding of the molecular pathways involved in the IR response and to identify potential predictive biomarkers of individual response involved in long-term health risks. Biological samples will be collected at three time points: before the first exposure, at the end of the exposure, and one year after the exposure. The average whole-body dose, the dose to the target organ, and the dose to some important out-of-field organs will be estimated. State-of-the-art analytical methods will be used to assess the levels of a set of known biomarkers and also explore high-resolution approaches of proteomics and miRNA transcriptomes to provide an integrated assessment. By using bioinformatics and systems biology, biological pathways and novel pathways involved in the response to IR exposure will be deciphered., The HARMONIC project (Health effects of cArdiac fluoRoscopy and MOderN radIotherapy in paediatriCs) has received funding from the Euratom research and training program 2014–2018 under grant agreement No 847707., Peer reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Monte Carlo simulation of the Varian TrueBeam flattened-filtered beams using a surrogate geometry in PRIMO

  • Rodríguez Olmos, Miguel David
  • Sempau Roma, Josep|||0000-0002-2754-7685
  • Brualla, Lorenzo
Background. Monte Carlo simulation of radiation transport for medical linear accelerators (linacs) requires accurate knowledge of the geometrical description of the linac head. Since the geometry of Varian TrueBeam machines has not been disclosed, the manufacturer distributes phase-space files of the linac patient-independent part to allow researchers to compute absorbed dose distributions using the Monte Carlo method. This approach limits the possibility of achieving an arbitrarily small statistical uncertainty. This work investigates the use of the geometry of the Varian Clinac 2100, which is included in the Monte Carlo system PRIMO, as a surrogate. Methods. Energy, radial and angular distributions extracted from the TrueBeam phase space files published by the manufacturer and from phase spaces tallied with PRIMO for the Clinac 2100 were compared for the 6, 8, 10 and 15 MV flattened-filtered beams. Dose distributions in water computed for the two sets of PSFs were compared with the Varian Representative Beam Data (RBD) for square fields with sides ranging from 3 to 30 cm. Output factors were calculated for square fields with sides ranging from 2 to 40 cm. Results. Excellent agreement with the RBD was obtained for the simulations that employed the phase spaces distributed by Varian as well as for those that used the surrogate geometry, reaching in both cases Gamma ( , 2 mm) pass rates larger than , except for the 15 MV surrogate. This result supports previous investigations that suggest a change in the material composition of the TrueBeam 15 MV flattening filter. In order to get the said agreement, PRIMO simulations were run using enlarged transport parameters to compensate the discrepancies between the actual and surrogate geometries. Conclusions. This work sustains the claim that the simulation of the 6, 8 and 10 MV flattening-filtered beams of the TrueBeam linac can be performed using the Clinac 2100 model of PRIMO without significant loss of accuracy., Open Access funding enabled and organized by Projekt DEAL. The authors acknowledge support by the Open Access Publication Fund of the University of Duisburg-Essen. MR acknowledges funding by the Sistema Nacional de Investigación de Panamá (SNI). JS thanks the Spanish Ministerio de Ciencia e Innovación, project PID2019-104714GB-C22. LB acknowledges funding by the HARMONIC project. The HARMONIC project (Health effects of cArdiac fluoRoscopy and MOderN radIotherapy in paediatriCs) has received funding from the Euratom research and training programme 2014-2018 under grant agreement number 847707.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Medical applications of ionizing radiation and radiation protection for European patients, population and environment

  • Thierry-Chef, Isabelle
  • Cardis, Elisabeth
  • Damilakis, John
  • Frija, Guy
  • Hierath, Monika
  • Hoeschen, Christop
  • EURAMED ROCC-N-ROLL consortia members
Medical applications of ionising radiation (IR) represent a key component of the diagnosis and treatment of many diseases, guaranteeing efficient health care. The use of IR in medicine, the largest source of general population radiation exposure, is potentially associated with increased risk of cancer and non-cancer diseases, which needs to be evaluated to provide evidence-based input for risk-benefit considerations. Efforts are also needed to improve the safety and efficacy of medical applications through optimisation. The EC Euratom programme enhances research in medical radiation protection. The four complementary multidisciplinary projects presented here contribute to (1) improving knowledge on exposure and effects of diagnostic and therapeutic applications and (2) transferring results into clinical practice. The common aim is to optimise use for individual patients, enhance education and training, ensuring adherence to ethical standards, particularly related to technologies based on artificial intelligence. MEDIRAD, SINFONIA and HARMONIC focus on improving exposure estimation and studying the detrimental effects of diagnostic and therapeutic medical exposures in patients and staff using different endpoints. EURAMED rocc-n-roll brings together the results of the projects and the recommendations generated by them to build, in collaboration with the EU Radiation Protection research platforms, a strategic research agenda and a roadmap for research priorities., The HARMONIC project has received funding from the Euratom research and training programme 2014–2018 under grant agreement No. 847707. The MEDIRAD project has received funding from Euratom’s research and innovation programme 2014–2018 under grant agreement No. 755523. The SINFONIA project has received funding from the Euratom research and training programme 2019–2020 under grant agreement No. 945196. The EURAMED ROCC-N-ROLL project has received funding from the Euratom research and training programme 2019–2020 under grant agreement No 899995. ISGlobal also acknowledges support from the Spanish Ministry of Science, Innovation and Universities through the “Centro de Excelencia Severo Ochoa 2019–2023” Program (CEX2018-000806-S), support from the Generalitat de Catalunya through the CERCA Program and support from the Secretariat of Universities and Research of the Department of Business and Knowledge of the Generalitat of Catalonia through AGAUR (the Catalan Agency for Management of University and Research Grants) (Project 2017 SGR 1487).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Validation of a Monte Carlo framework for out-of-field dose calculations in proton therapy

  • De Saint-Hubert, Marijke
  • Verbeek, Nico
  • Bäumer, Christian
  • Esser, Johannes
  • Wulff, Jörg
  • Nabha, Racell
  • Van Hoey, Olivier
  • Dabin, Jérémie
  • Stuckmann, Florian
  • Vasi, Fabiano
  • Radonic, Stephan
  • Boissonnat, Guillaume
  • Schneider, Uwe
  • Rodriguez, Miguel
  • Timmermann, Beate
  • Thierry-Chef, Isabelle
  • Brualla, Lorenzo
Proton therapy enables to deliver highly conformed dose distributions owing to the characteristic Bragg peak and the finite range of protons. However, during proton therapy, secondary neutrons are created, which can travel long distances and deposit dose in out-of-field volumes. This out-of-field absorbed dose needs to be considered for radiation-induced secondary cancers, which are particularly relevant in the case of pediatric treatments. Unfortunately, no method exists in clinics for the computation of the out-of-field dose distributions in proton therapy. To help overcome this limitation, a computational tool has been developed based on the Monte Carlo code TOPAS. The purpose of this work is to evaluate the accuracy of this tool in comparison to experimental data obtained from an anthropomorphic phantom irradiation. An anthropomorphic phantom of a 5-year-old child (ATOM, CIRS) was irradiated for a brain tumor treatment in an IBA Proteus Plus facility using a pencil beam dedicated nozzle. The treatment consisted of three pencil beam scanning fields employing a lucite range shifter. Proton energies ranged from 100 to 165 MeV. A median dose of 50.4 Gy(RBE) with 1.8 Gy(RBE) per fraction was prescribed to the initial planning target volume (PTV), which was located in the cerebellum. Thermoluminescent detectors (TLDs), namely, Li-7-enriched LiF : Mg, Ti (MTS-7) type, were used to detect gamma radiation, which is produced by nuclear reactions, and secondary as well as recoil protons created out-of-field by secondary neutrons. Li-6-enriched LiF : Mg,Cu,P (MCP-6) was combined with Li-7-enriched MCP-7 to measure thermal neutrons. TLDs were calibrated in Co-60 and reported on absorbed dose in water per target dose (μGy/Gy) as well as thermal neutron dose equivalent per target dose (μSv/Gy). Additionally, bubble detectors for personal neutron dosimetry (BD-PND) were used for measuring neutrons (>50 keV), which were calibrated in a Cf-252 neutron beam to report on neutron dose equivalent dose data. The Monte Carlo code TOPAS (version 3.6) was run using a phase-space file containing 1010 histories reaching an average standard statistical uncertainty of less than 0.2% (coverage factor k = 1) on all voxels scoring more than 50% of the maximum dose. The primary beam was modeled following a Fermi-Eyges description of the spot envelope fitted to measurements. For the Monte Carlo simulation, the chemical composition of the tissues represented in ATOM was employed. The dose was tallied as dose-to-water, and data were normalized to the target dose (physical dose) to report on absorbed doses per target dose (mSv/Gy) or neutron dose equivalent per target dose (μSv/Gy), while also an estimate of the total organ dose was provided for a target dose of 50.4 Gy(RBE). Out-of-field doses showed absorbed doses that were 5 to 6 orders of magnitude lower than the target dose. The discrepancy between TLD data and the corresponding scored values in the Monte Carlo calculations involving proton and gamma contributions was on average 18%. The comparison between the neutron equivalent doses between the Monte Carlo simulation and the measured neutron doses was on average 8%. Organ dose calculations revealed the highest dose for the thyroid, which was 120 mSv, while other organ doses ranged from 18 mSv in the lungs to 0.6 mSv in the testes. The proposed computational method for routine calculation of the out-of-the-field dose in proton therapy produces results that are compatible with the experimental data and allow to calculate out-of-field organ doses during proton therapy., The presented research has been funded by the HARMONIC project. The HARMONIC project (Health effects of cArdiac fluoRoscopy and MOderN radIotherapy in paediatriCs) has received funding from the Euratom research and training program 2014-2018 under grant agreement No 847707. MR acknowledges funding from the Sistema Nacional de Investigación de Panamá. IT-C acknowledges support from the Spanish Ministry of Science and Innovation and State Research Agency through the “Centro de Excelencia Severo Ochoa 2019-2023” Program (CEX2018-000806-S) and support from the Generalitat de Catalunya through the CERCA Program.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Complete patient exposure during paediatric brain cancer treatment for photon and proton therapy techniques including imaging procedures

  • De Saint-Hubert, Marijke
  • Boissonnat, Guillaume
  • Schneider, Uwe
  • Bäumer, Christian
  • Verbeek, Nico
  • Esser, Johannes
  • Wulff, Jörg
  • Stuckmann, Florian
  • Suesselbeck, Finja
  • Nabha, Racell
  • Dabin, Jérémie
  • Vasi, Fabiano
  • Radonic, Stephan
  • Rodriguez, Miguel
  • Simon, Anne Catherine
  • Journy, Neige
  • Timmermann, Beate
  • Thierry-Chef, Isabelle
  • Brualla, Lorenzo
Background: In radiotherapy, especially when treating children, minimising exposure of healthy tissue can prevent the development of adverse outcomes, including second cancers. In this study we propose a validated Monte Carlo framework to evaluate the complete patient exposure during paediatric brain cancer treatment. Materials and methods: Organ doses were calculated for treatment of a diffuse midline glioma (50.4 Gy with 1.8 Gy per fraction) on a 5-year-old anthropomorphic phantom with 3D-conformal radiotherapy, intensity modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT) and intensity modulated pencil beam scanning (PBS) proton therapy. Doses from computed tomography (CT) for planning and on-board imaging for positioning (kV-cone beam CT and X-ray imaging) accounted for the estimate of the exposure of the patient including imaging therapeutic dose. For dose calculations we used validated Monte Carlo-based tools (PRIMO, TOPAS, PENELOPE), while lifetime attributable risk (LAR) was estimated from dose-response relationships for cancer induction, proposed by Schneider et al. Results: Out-of-field organ dose equivalent data of proton therapy are lower, with doses between 0.6 mSv (testes) and 120 mSv (thyroid), when compared to photon therapy revealing the highest out-of-field doses for IMRT ranging between 43 mSv (testes) and 575 mSv (thyroid). Dose delivered by CT ranged between 0.01 mSv (testes) and 72 mSv (scapula) while a single imaging positioning ranged between 2 μSv (testes) and 1.3 mSv (thyroid) for CBCT and 0.03 μSv (testes) and 48 μSv (scapula) for X-ray. Adding imaging dose from CT and daily CBCT to the therapeutic demonstrated an important contribution of imaging to the overall radiation burden in the course of treatment, which is subsequently used to predict the LAR, for selected organs. Conclusion: The complete patient exposure during paediatric brain cancer treatment was estimated by combining the results from different Monte Carlo-based dosimetry tools, showing that proton therapy allows significant reduction of the out-of-field doses and secondary cancer risk in selected organs., The presented research has been funded by the HARMONIC project. The HARMONIC project (Health effects of cArdiac fluoRoscopy and MOderN radIotherapy in paediatriCs) has received funding from the Euratom research and training programme 2014-2018 under grant agreement No 847707. IT-C acknowledges support from the Spanish Ministry of Science and Innovation and State Research Agency through the ‘Centro de Excelencia Severo Ochoa 2019-2023’ Program (CEX2018-000806-S), and support from the Generalitat de Catalunya through the CERCA Program.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Health effects of ionising radiation in paediatrics undergoing either cardiac fluoroscopy or modern radiotherapy (The HARMONIC project)

  • Thierry-Chef, Isabelle
  • Sarukhan, Adelaida
  • Ortiz, Rodney
  • Chumak, Vadim
The use of ionising radiation (IR) for medical diagnosis and treatment procedures has had a major impact on the survival of paediatric patients. Although the benefits of these techniques lead to efficient health care, evaluation of potential associated long-term health effects is required. HARMONIC aims to better understand the increased risk of cancer and non-cancer effects after exposure to medical IR in children with cancer treated with modern external beam radiotherapy (EBRT) – radiation energy in MeV range – and in children with cardiac defects diagnosed and treated with cardiac fluoroscopy procedures (CFP) – radiation energy in keV range. The project investigates, among survivors of paediatric cancer, potential endocrine dysfunction, cardiovascular and neurovascular damage, health-related quality of life and second (and subsequent) primary cancer (SPC). The cardiac component builds a pooled cohort of approximately 90 000 paediatric patients who underwent CFP during childhood and adolescence to investigate cancer risk following exposure to IR and explore the potential effects of conditions predisposing to cancer. HARMONIC develops software tools to allow dose reconstruction in both EBRT and CFP to enable epidemiological investigations and future optimisation of treatments. With the creation of a biobank of blood and saliva samples, HARMONIC aims to provide a mechanistic understanding of radiation-induced adverse health effects and identify potential biomarkers that can predict these effects., The HARMONIC project has received funding from the Euratom research and training programme 2014–2018 under grant agreement No. 847707.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Monte Carlo simulation of the Varian TrueBeam flattened-filtered beams using a surrogate geometry in PRIMO

  • Rodríguez Olmos, Miguel David
  • Sempau Roma, Josep
  • Brualla, Lorenzo
Background. Monte Carlo simulation of radiation transport for medical linear accelerators (linacs) requires accurate knowledge of the geometrical description of the linac head. Since the geometry of Varian TrueBeam machines has not been disclosed, the manufacturer distributes phase-space files of the linac patient-independent part to allow researchers to compute absorbed dose distributions using the Monte Carlo method. This approach limits the possibility of achieving an arbitrarily small statistical uncertainty. This work investigates the use of the geometry of the Varian Clinac 2100, which is included in the Monte Carlo system PRIMO, as a surrogate. Methods. Energy, radial and angular distributions extracted from the TrueBeam phase space files published by the manufacturer and from phase spaces tallied with PRIMO for the Clinac 2100 were compared for the 6, 8, 10 and 15 MV flattened-filtered beams. Dose distributions in water computed for the two sets of PSFs were compared with the Varian Representative Beam Data (RBD) for square fields with sides ranging from 3 to 30 cm. Output factors were calculated for square fields with sides ranging from 2 to 40 cm. Results. Excellent agreement with the RBD was obtained for the simulations that employed the phase spaces distributed by Varian as well as for those that used the surrogate geometry, reaching in both cases Gamma ( , 2 mm) pass rates larger than , except for the 15 MV surrogate. This result supports previous investigations that suggest a change in the material composition of the TrueBeam 15 MV flattening filter. In order to get the said agreement, PRIMO simulations were run using enlarged transport parameters to compensate the discrepancies between the actual and surrogate geometries. Conclusions. This work sustains the claim that the simulation of the 6, 8 and 10 MV flattening-filtered beams of the TrueBeam linac can be performed using the Clinac 2100 model of PRIMO without significant loss of accuracy., Open Access funding enabled and organized by Projekt DEAL. The authors acknowledge support by the Open Access Publication Fund of the University of Duisburg-Essen. MR acknowledges funding by the Sistema Nacional de Investigación de Panamá (SNI). JS thanks the Spanish Ministerio de Ciencia e Innovación, project PID2019-104714GB-C22. LB acknowledges funding by the HARMONIC project. The HARMONIC project (Health effects of cArdiac fluoRoscopy and MOderN radIotherapy in paediatriCs) has received funding from the Euratom research and training programme 2014-2018 under grant agreement number 847707., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Experimental validation of an analytical program and a Monte Carlo simulation for the computation of the far out-of-field dose in external beam photon therapy applied to pediatric patients

  • De Saint-Hubert, Marijke
  • Suesselbeck, Finja
  • Vasi, Fabiano
  • Stuckmann, Florian
  • Rodriguez, Miguel
  • Dabin, Jérémie
  • Timmermann, Beate
  • Thierry-Chef, Isabelle
  • Schneider, Uwe
  • Brualla, Lorenzo
Background: The out-of-the-field absorbed dose affects the probability of primary second radiation-induced cancers. This is particularly relevant in the case of pediatric treatments. There are currently no methods employed in the clinical routine for the computation of dose distributions from stray radiation in radiotherapy. To overcome this limitation in the framework of conventional teletherapy with photon beams, two computational tools have been developed-one based on an analytical approach and another depending on a fast Monte Carlo algorithm. The purpose of this work is to evaluate the accuracy of these approaches by comparison with experimental data obtained from anthropomorphic phantom irradiations. Materials and methods: An anthropomorphic phantom representing a 5-year-old child (ATOM, CIRS) was irradiated considering a brain tumor using a Varian TrueBeam linac. Two treatments for the same planned target volume (PTV) were considered, namely, intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). In all cases, the irradiation was conducted with a 6-MV energy beam using the flattening filter for a prescribed dose of 3.6 Gy to the PTV. The phantom had natLiF : Mg, Cu, P (MCP-N) thermoluminescent dosimeters (TLDs) in its 180 holes. The uncertainty of the experimental data was around 20%, which was mostly attributed to the MCP-N energy dependence. To calculate the out-of-field dose, an analytical algorithm was implemented to be run from a Varian Eclipse TPS. This algorithm considers that all anatomical structures are filled with water, with the exception of the lungs which are made of air. The fast Monte Carlo code dose planning method was also used for computing the out-of-field dose. It was executed from the dose verification system PRIMO using a phase-space file containing 3x109 histories, reaching an average standard statistical uncertainty of less than 0.2% (coverage factor k = 1 ) on all voxels scoring more than 50% of the maximum dose. The standard statistical uncertainty of out-of-field voxels in the Monte Carlo simulation did not exceed 5%. For the Monte Carlo simulation the actual chemical composition of the materials used in ATOM, as provided by the manufacturer, was employed. Results: In the out-of-the-field region, the absorbed dose was on average four orders of magnitude lower than the dose at the PTV. For the two modalities employed, the discrepancy between the central values of the TLDs located in the out-of-the-field region and the corresponding positions in the analytic model were in general less than 40%. The discrepancy in the lung doses was more pronounced for IMRT. The same comparison between the experimental and the Monte Carlo data yielded differences which are, in general, smaller than 20%. It was observed that the VMAT irradiation produces the smallest out-of-the-field dose when compared to IMRT. Conclusions: The proposed computational methods for the routine calculation of the out-of-the-field dose produce results that are similar, in most cases, with the experimental data. It has been experimentally found that the VMAT irradiation produces the smallest out-of-the-field dose when compared to IMRT for a given PTV., The presented research has been funded by the HARMONIC project. The HARMONIC project (Health effects of cArdiac fluoRoscopy and MOderN radIotherapy in paediatriCs) has received funding from the Euratom research and training programme 2014-2018 under grant agreement number 847707. MR acknowledges funding from the Sistema Nacional de Investigación de Panamá. ITC acknowledges support from the Spanish Ministry of Science and Innovation and State Research Agency through the “Centro de Excelencia Severo Ochoa 2019-2023” Program (CEX2018-000806-S) and support from the Generalitat de Catalunya through the CERCA Program.