Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Medical applications of ionizing radiation and radiation protection for European patients, population and environment

  • Thierry-Chef, Isabelle
  • Cardis, Elisabeth
  • Damilakis, John
  • Frija, Guy
  • Hierath, Monika
  • Hoeschen, Christop
  • EURAMED ROCC-N-ROLL consortia members
Medical applications of ionising radiation (IR) represent a key component of the diagnosis and treatment of many diseases, guaranteeing efficient health care. The use of IR in medicine, the largest source of general population radiation exposure, is potentially associated with increased risk of cancer and non-cancer diseases, which needs to be evaluated to provide evidence-based input for risk-benefit considerations. Efforts are also needed to improve the safety and efficacy of medical applications through optimisation. The EC Euratom programme enhances research in medical radiation protection. The four complementary multidisciplinary projects presented here contribute to (1) improving knowledge on exposure and effects of diagnostic and therapeutic applications and (2) transferring results into clinical practice. The common aim is to optimise use for individual patients, enhance education and training, ensuring adherence to ethical standards, particularly related to technologies based on artificial intelligence. MEDIRAD, SINFONIA and HARMONIC focus on improving exposure estimation and studying the detrimental effects of diagnostic and therapeutic medical exposures in patients and staff using different endpoints. EURAMED rocc-n-roll brings together the results of the projects and the recommendations generated by them to build, in collaboration with the EU Radiation Protection research platforms, a strategic research agenda and a roadmap for research priorities., The HARMONIC project has received funding from the Euratom research and training programme 2014–2018 under grant agreement No. 847707. The MEDIRAD project has received funding from Euratom’s research and innovation programme 2014–2018 under grant agreement No. 755523. The SINFONIA project has received funding from the Euratom research and training programme 2019–2020 under grant agreement No. 945196. The EURAMED ROCC-N-ROLL project has received funding from the Euratom research and training programme 2019–2020 under grant agreement No 899995. ISGlobal also acknowledges support from the Spanish Ministry of Science, Innovation and Universities through the “Centro de Excelencia Severo Ochoa 2019–2023” Program (CEX2018-000806-S), support from the Generalitat de Catalunya through the CERCA Program and support from the Secretariat of Universities and Research of the Department of Business and Knowledge of the Generalitat of Catalonia through AGAUR (the Catalan Agency for Management of University and Research Grants) (Project 2017 SGR 1487).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Medical applications of ionizing radiation and radiation protection for European patients, population and environment

  • Thierry-Chef, Isabelle
  • Cardis, Elisabeth
  • Damilakis, John
  • Frija, Guy
  • Hierath, Monika
  • Hoeschen, Christop
  • EURAMED ROCC-N-ROLL consortia members
Medical applications of ionising radiation (IR) represent a key component of the diagnosis and treatment of many diseases, guaranteeing efficient health care. The use of IR in medicine, the largest source of general population radiation exposure, is potentially associated with increased risk of cancer and non-cancer diseases, which needs to be evaluated to provide evidence-based input for risk-benefit considerations. Efforts are also needed to improve the safety and efficacy of medical applications through optimisation. The EC Euratom programme enhances research in medical radiation protection. The four complementary multidisciplinary projects presented here contribute to (1) improving knowledge on exposure and effects of diagnostic and therapeutic applications and (2) transferring results into clinical practice. The common aim is to optimise use for individual patients, enhance education and training, ensuring adherence to ethical standards, particularly related to technologies based on artificial intelligence. MEDIRAD, SINFONIA and HARMONIC focus on improving exposure estimation and studying the detrimental effects of diagnostic and therapeutic medical exposures in patients and staff using different endpoints. EURAMED rocc-n-roll brings together the results of the projects and the recommendations generated by them to build, in collaboration with the EU Radiation Protection research platforms, a strategic research agenda and a roadmap for research priorities., The HARMONIC project has received funding from the Euratom research and training programme 2014–2018 under grant agreement No. 847707. The MEDIRAD project has received funding from Euratom’s research and innovation programme 2014–2018 under grant agreement No. 755523. The SINFONIA project has received funding from the Euratom research and training programme 2019–2020 under grant agreement No. 945196. The EURAMED ROCC-N-ROLL project has received funding from the Euratom research and training programme 2019–2020 under grant agreement No 899995. ISGlobal also acknowledges support from the Spanish Ministry of Science, Innovation and Universities through the “Centro de Excelencia Severo Ochoa 2019–2023” Program (CEX2018-000806-S), support from the Generalitat de Catalunya through the CERCA Program and support from the Secretariat of Universities and Research of the Department of Business and Knowledge of the Generalitat of Catalonia through AGAUR (the Catalan Agency for Management of University and Research Grants) (Project 2017 SGR 1487).
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Peripheral Organ Equivalent Dose Estimation Procedure in Proton Therapy

  • Domingo, Carles|||0000-0002-8480-692X
  • Lagares, Juan Ignacio
  • Romero-Expósito, Maite
  • Sánchez-Nieto, Beatriz
  • Nieto-Camero, Jaime J.
  • Terrón, Jose Antonio
  • Irazola, Leticia
  • Dasu, Alexandru
  • Sánchez-Doblado, Francisco
The aim of this work is to present a reproducible methodology for the evaluation of total equivalent doses in organs during proton therapy facilities. The methodology is based on measuring the dose equivalent in representative locations inside an anthropomorphic phantom where photon and neutron dosimeters were inserted. The Monte Carlo simulation was needed for obtaining neutron energy distribution inside the phantom. The methodology was implemented for a head irradiation case in the passive proton beam of iThemba Labs (South Africa). Thermoluminescent dosimeter (TLD)-600 and TLD-700 pairs were used as dosimeters inside the phantom and GEANT code for simulations. In addition, Bonner sphere spectrometry was performed inside the treatment room to obtain the neutron spectra, some relevant neutron dosimetric quantities per treatment Gy, and a percentual distribution of neutron fluence and ambient dose equivalent in four energy groups, at two locations. The neutron spectrum at one of those locations was also simulated so that a reasonable agreement between simulation and measurement allowed a validation of the simulation. Results showed that the total out-of-field dose equivalent inside the phantom ranged from 1.4 to 0.28 mSv/Gy, mainly due to the neutron contribution and with a small contribution from photons, 10% on average. The order of magnitude of the equivalent dose in organs was similar, displaying a slow reduction in values as the organ is farther from the target volume. These values were in agreement with those found by other authors in other passive beam facilities under similar irradiation and measurement conditions.