Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Fully integrated miniaturized wireless power transfer rectenna for medical applications tested inside biological tissues

  • Fernández Muñoz, Miguel|||0000-0001-8872-7834
  • Missous, Mohamed
  • Sadeghi, Mohammadreza
  • López Espí, Pablo Luis|||0000-0003-3750-255X
  • Sánchez Montero, Rocío|||0000-0002-3135-8828
  • Martínez Rojas, Juan Antonio|||0000-0001-8842-6986
  • Díez Jiménez, Efrén|||0000-0002-3689-841X
This work presents the results of the characterization of two 1 × 5 mm2 miniaturized rectennas developed for medical applications. They have been designed for relatively high voltage and high-power applications, given the size of the rectennas. Both rectennas were tested in open-air conditions and surrounded by pork fat and muscle tissues, whose properties are similar to those of the human body. The resonant frequencies of the rectennas were found, and the incident electric field on the rectennas tests was increased. The first chip showed a maximum output voltage of 5.29 V and a maximum output power of 0.056 mW, at 1.446 GHz, under an incident field on the rectenna of 340 V/m, and the second chip, 4.62 V and 4.27 mW, at 1.175 GHz, under 535 V/m. The second rectenna can provide an output power greater than 5 mW. The rectennas presented in this article are beyond the state of the art, as they can deliver about three times more power and voltage than those of similar dimensions reported in the literature. Based on the test results, the efficiency of the rectennas was analyzed at different locations of the human body, considering different thicknesses of tissues with high and low water content. Finally, potential applications are described in which the rectennas could power implantable medical devices or microsurgery tools, for example, pulmonary artery pressure monitors., European Commission
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Model-based systems engineering applied to trade-off analysis of wireless power transfer technologies for implanted biomedical microdevices

  • Martínez Rojas, Juan Antonio|||0000-0001-8842-6986
  • Fernández Sánchez, José L.
  • Sánchez Montero, Rocío|||0000-0002-3135-8828
  • López Espí, Pablo Luis|||0000-0003-3750-255X
  • Díez Jiménez, Efrén|||0000-0002-3689-841X
Decision-making is an important part of human life and particularly in any engineering process related to a complex product. New sensors and actuators based on MEMS technologies are increasingly complex and quickly evolving into products. New biomedical implanted devices may benefit from system engineering approaches, previously reserved to very large projects, and it is expected that this need will increase in the future. Here, we propose the application of Model Based Systems Engineering (MBSE) to systematize and optimize the trade-off analysis process. The criteria, their utility functions and the weighting factors are applied in a systematic way for the selection of the best alternative. Combining trade-off with MBSE allow us to identify the more suitable technology to be implemented to transfer energy to an implanted biomedical micro device., European Commission
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Model-based systems engineering approach to the study of electromagnetic interference and compatibility in wireless powered microelectromechanical systems

  • Martínez Rojas, Juan Antonio|||0000-0001-8842-6986
  • Fernández Sánchez, José L.
  • Fernández Muñoz, Miguel|||0000-0001-8872-7834
  • Sánchez Montero, Rocío|||0000-0002-3135-8828
  • López Espí, Pablo Luis|||0000-0003-3750-255X
  • Díez Jiménez, Efrén|||0000-0002-3689-841X
Electromagnetic Interference and Compatibility (EMI–EMC) are a serious problem in Microelectromechanical Systems (MEMS), and specially in powered by wireless energy transfer MEMS. Most MEMS have dimensions in the order of 1 mm or less, thus, most of the suitable electromagnetic radiation sources have wavelengths larger than this, making isolation of electromagnetic effects very difficult. Model-Based Systems Engineering (MBSE) can be an excellent tool to deal with EMI—EMC in MEMS during early design phases. In this work, we present a problem-solving procedure and integration of EMI—EMC in MEMS from a Model-Based Systems Engineering perspective. This approach is described in detail by a real example using a procedure based on nine steps fully integrated with the proposed systems engineering methodology. For example, the use of context diagrams (IBDs) and N SQUARE charts to describe EMC interactions is explained in detail. The system is formed by a Wireless Power Transfer (WPT) subsystem working near 2.45 or 4.5 GHz coupled to an electromagnetic micromotor. This micromotor contains copper microcoils which can receive electromagnetic radiation directly at the same time that the WPT subsystem. The greatest difficulty is, then, to power the WPT while isolating the micromotor, and optimizing the coupling interface. A summary of the most important EMC concepts and tools are reviewed from the systems engineer perspective and possible problems during the design and testing phases are discussed in detail using the example., European Commission
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Experimental study of micromilling process and deburring electropolishing process on FeCo-based soft magnetic alloys

  • Villalba Alumbreros, Gabriel
  • López Cámara, Enrique
  • Martínez Gómez, Javier|||0000-0001-8807-7595
  • Cóbreces Álvarez, Santiago|||0000-0002-3308-4613
  • Valiente Blanco, Ignacio|||0000-0001-5068-7910
  • Díez Jiménez, Efrén|||0000-0002-3689-841X
FeCo-based soft magnetic alloys are commonly used in macroscale devices to improve its electromagnetic performance, whereas they have been barely used in the microscale. Current FeCo alloy micromanufacturing processes present some difficulties like low structural strength, oxidation at high temperature processes, stoichiometry mismatches in deposition processes and tough workability. In this work, a microcutting of FeCo-2 V-based soft magnetic alloys process is presented and described as an alternative method to obtain microparts with high magnetic properties and good geometrical finish. The results of the machining process are analysed by varying the machining parameters such as depth of cut, tool diameter, rotation speed and feed speed on simple machining operations. The study has been done for 50-μm-diameter endmill and 250-μm-diameter endmill tools. It concludes that the roughness is minimized when machining parameter combination is 0.24 mm/min of feed rate and 8 μm of depth of cut size for a 250-μm-diameter tool, while for a 50-μm-diameter tool, the selected feed rate is 0.24 mm/min, for a depth of cut between 2 and 4 μm. An automated precision 3-axis CNC station is used. Shapes needed for actuators such as angular slots, disks, or slender square geometries are shown in this work with excellent magnetic and mechanical properties. Additionally, a complementary electropolishing process is described. This process helps to eliminate burr in edges and residuals of the milling operation. This study demonstrates that micromilling can be a good alternative for microfabrication of FeCo-2 V components, suitable for precision microassemblies on MEMS., European Commission, Ministerio de Ciencia e Innovación