Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 10
Encontrada(s) 1 página(s)

e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

Reducing Blackout Risk by Segmenting European Power Grid with HVDC Lines

  • Gomila, Damià
  • Carreras Verdaguer, Benjamin A.
  • Reynolds Barredo, José Miguel
  • Martínez Barbeito, María
  • Colet, Pere
  • Gomis Bellmunt, Oriol
The utilization of high-voltage direct current (HVDC) lines for the segmentation of the European power grid has been demonstrated to be a highly effective strategy for the mitigation of the risk of cascading blackouts. In this study, an accurate and efficient method for determining the optimal power flow through HVDC lines is presented, with the objective of minimizing load shedding. The proposed method is applied to two distinct scenarios: first, the segmentation of the power grid along the Pyrenees, with the objective of segmenting the Iberian Peninsula from the rest of Europe; and second, the segmentation of the power grid into Eastern and Western Europe, approximately in half. In both scenarios, the method effectively reduces the size of blackouts impacting both sides of the HVDC lines, resulting in a 46% and 67% reduction in total blackout risk, respectively. Furthermore, we have estimated the cost savings from risk reduction and the expenses associated with converting conventional lines to HVDC lines. Our findings indicate that segmenting the European power grid with HVDC lines is economically viable, particularly for segmenting the Iberian Peninsula, due to its favorable cost-risk reduction ratio., This work was supported by MCIN/AEI/10.13039/501100011033 (No. PID2021-122256NB-C22, No. CEX2021-001164-M) and the European Union’s Horizon 2020 Research and Innovation Programme (Grant Agreement No. 957852, VPP4Islands). We acknowledge access to Uranus, a supercomputer clus ter located at Universidad Carlos III de Madrid (Spain).
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

Analysis of the blackout risk reduction when segmenting large power systems using lines with controllable power flow

  • Gomila, D.
  • Carreras, Benjamín A.
  • Reynolds Barredo, José Miguel
  • Colet, P.
  • Gomis Bellmunt, O.
Large electrical transmission networks are susceptible to undergo very large blackouts due to cascading failures, with a very large associated economical cost. In this work we propose segmenting large power grids using controllable lines, such as high-voltage direct-current lines, to reduce the risk of blackouts. The method consists in modifying the power flowing through the lines interconnecting different zones during cascading failures in order to minimize the load shed. As a result, the segmented grids have a substantially lower risk of blackouts than the original network, with reductions up to 60% in some cases. The control method is shown to be specially efficient in reducing blackouts affecting more than one zone., DG and PC acknowledge funding from project PACSS RTI2018-093732-B-C22 and APASOS PID2021-122256NB-C22 of the MCIN/AEI/10.13039/501100011033/ and by EU through FEDER funds (A way to make Europe), from the Maria de Maeztu program MDM-2017-0711 of the MCIN/AEI/10.13039/501100011033/, and also from the European Union's Horizon 2020 research and innovation programme (Grant Agreement No. 957852, VPP4Islands). B.A.C. and J.M.R.-B. acknowledge access to Uranus, a supercomputer cluster located at Universidad Carlos III de Madrid (Spain) funded jointly by EU FEDER funds and by the Spanish Government via the National Research Project Nos. UNC313-4E-2361, ENE2009-12213-C03-03, ENE2012-33219, and ENE2012-31753. OGB was supported in part by FEDER/Ministerio de Ciencia, Innovacion y Universidades - Agencia Estatal de Investigación, Project RTI2018-095429-B-I00 and in part by FI-AGAUR Research Fellowship Program, Generalitat de Catalunya. The work of OGB is supported by the ICREA Academia program.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Modelling energy storage systems in power grids

  • Ruzzene, Giulia
  • Gomila, Damià
  • Colet, Pere
Trabajo presentado en el IFISC Poster Party (online).-- The IFISC Poster Party is an annual activity where PhD students and postdoctoral researchers of IFISC present their research in a poster format.-- Dynamics and Collective Phenomena in Social and Socio-technical Systems., There is a need for more sustainable energy production: this leads to the incorporation of renewable energy resources in power grids. Renewable energy resources provide a fluctuating output (depending on weather, season, etc.) which needs to be compensated with a control mechanism. A possible control mechanism is the introduction of a battery, which can store and provide energy when needed. The objective of this work is to introduce a battery in a model of a conventional power plant for frequency control and grid stability, We acknowledge financial support from Agencia Estatal de Investigación (AEI, Spain), and Fondo Europeo de Desarrollo Regional (FEDER, EU) under grant PACSS (RTI2018-093732-B-C22) and the Maria de Maeztu program for Units of Excellence in R&D (MDM-2017-0711), and from European Commission under Horizon2020 Innovation Action VPP4ISLANDS (grant agreement 957852)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Battery control models for frequency stability in power grids with renewables

  • Ruzzene, Giulia
  • Gomila, Damià
  • Colet, Pere
Trabajo presentado en el IFISC Poster Party (online).-- The IFISC Poster Party is an annual activity where PhD students and postdoctoral researchers of IFISC present their research in a poster format.-- Dynamics and Collective Phenomena in Social and Socio-technical Systems., The ecological transition to cleaner energy production is a fundamental part in facing the challenge of climate change. Many renewables, such as solar and wind powers, have an intermittent nature as their outputs strongly depend on factors like the weather, time of the day, season etc. This may create issues to the stability of the power grid, in particular it may accentuate frequency fluctuations. A possible solution to this problem is the introduction of energy storage systems in the grid, such as batteries. In this study we propose two different algorithms for battery operations: one is based on an optimisation technique called model predictive control which aims at smoothing power from renewables, and another which acts as an additional primary and secondary control., We acknowledge funding from project PACSS RTI2018-093732-B-C22 of the MCIN/AEI/10.13039/501100011033/ and by EU through FEDER funds, from the Maria de Maeztu program MDM-2017-0711 of the MCIN/AEI/10.13039/501100011033/, and from European Commission under Horizon2020 Innovation Action VPP4ISLANDS (grant agreement 957852)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Analysis of the blackout risk reduction when segmenting large power systems using lines with controllable power flow

  • Gomila, Damià
  • Carreras, Benjamin A.
  • Reynolds-Barredo, José M.
  • Colet, Pere
  • Gomis-Bellmunt, O.
Large electrical transmission networks are susceptible to undergo very large blackouts due to cascading failures, with a very large associated economical cost. In this work we propose segmenting large power grids using controllable lines, such as high-voltage direct-current lines, to reduce the risk of blackouts. The method consists in modifying the power flowing through the lines interconnecting different zones during cascading failures in order to minimize the load shed. As a result, the segmented grids have a substantially lower risk of blackouts than the original network, with reductions up to 60% in some cases. The control method is shown to be specially efficient in reducing blackouts affecting more than one zone., DG and PC acknowledge funding from project PACSS RTI2018-093732-B-C22 and APASOS PID2021-122256NB-C22 of the MCIN/AEI/10.13039/501100011033/ and by EU through FEDER funds (A way to make Europe), from the Maria de Maeztu program MDM-2017-0711 of the MCIN/AEI/10.13039/501100011033/, and also from the European Union’s Horizon 2020 research and innovation programme (Grant Agreement No. 957852, VPP4Islands). B.A.C. and J.M.R.-B. acknowledge access to Uranus, a supercomputer cluster located at Universidad Carlos III de Madrid (Spain) funded jointly by EU FEDER funds and by the Spanish Government via the National Research Project Nos. UNC313- 4E-2361, ENE2009-12213-C03-03, ENE2012-33219, and ENE2012-31753. OGB was supported in part by FEDER/Ministerio de Ciencia, Innovacion y Universidades - Agencia Estatal de Investigacion, Project RTI2018-095429-B-I00 and in part by FI-AGAUR Research Fellowship Program, Generalitat de Catalunya . The work of OGB is supported by the ICREA Academia program ., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Otros (Other)

Reducing Blackout Risk by Segmenting the European Power Grid with Hvdc Lines

  • Gomila, Damià
  • Carreras, Benjamin A.
  • Reynolds-Barredo, José M.
  • Martínez-Barbeito, María
  • Colet, Pere
  • Gomis-Bellmunt, O.
Segmenting the continental Europe power grid using high-voltage direct-current (HVDC) lines can help in reducing the risk of cascading blackouts. In this work we present an accurate and efficient method to determine the power that must flow through these lines in order to minimize the load shed. As an example, the method is applied to the case where the European grid is segmented, first, through the Pyrenees separating the Iberian peninsula from the rest of Europe and, second, dividing the network in approximately two halves, Eastern and Western Europe. In both cases the method is very efficient in reducing the size of blackouts involving both sides of the HVDC lines. Globally, this reduction translates in a decrease of the total blackout risk of approximately 46% and 67% respectively. We estimate also the savings due to the risk reduction and the cost of converting the necessary conventional lines to HVDC. The results show that segmentation of the European grid using HVDC could be economically viable, specially the case of segmenting the Iberian peninsula, as the cost-risk reduction ratio is lower., DG and PC acknowledge funding from MCIN/AEI/10.13039/501100011033/FEDER/EU under project APASOS (PID2021-122256NB-C22) and from MCIN/AEI/10.13039/501100011033 under the Maria de Maeztu Program for units of Excellence in R&D CEX2021-001164-M, and also from the European Union’s Horizon 2020 research and innovation programme (Grant Agreement No. 957852, VPP4Islands). B.A.C. and J.M.R.-B. acknowledge access to Uranus, a supercomputer cluster located at Universidad Carlos III de Madrid (Spain) funded jointly by EU FEDER funds and by the Spanish Government via the National Research Project Nos. UNC313- 4E-2361, ENE2009-12213-C03-03, ENE2012-33219, and ENE2012-31753. OGB was supported in part by FEDER/Ministerio de Ciencia, Innovacion y Universidades - Agencia Estatal de Investigacion, Project RTI2018-095429-B-I00 and in part by FI-AGAUR Research Fellowship Program, Generalitat de Catalunya. The work of OGB is supported by the ICREA Academia program., With funding from the Spanish government through the "Severo Ochoa Centre of Excellence" accreditation (CEX2021-001164-M)., No
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Transmission grid stability with large interregional power flows

  • Martínez Barbeito, María
  • Gomila, Damià
  • Colet, Pere
  • Fritzsch, Julian
  • Jacquod, Philippe
We propose a general methodology for identifying critical lines in the long-distance transmission of power across large electric grids. When the system is pushed to its operational limit, for instance by large power imbalances such as those generated by high penetration of variable renewable energy sources, the network gets destabilized and loses synchrony. We investigate a model of the synchronous AC grid of continental Europe under tunable large interregional power flows. When those flows exceed some critical value, we find that instabilities emerge due to topological constraints. We identify two different scenarios triggering these instabilities. In the first one, specific sets of lines reach their maximal load simultaneously, causing the grid to split into two desynchronized zones. In the second one, one or a few lines become overloaded, which eventually renders one Lyapunov exponent positive. The first scenario is obviously less generic and we develop a numerical approach to force the splitting of the AC grid into disconnected areas. Remarkably, the critical lines identified in this way match those that triggered the separation of the synchronous grid of continental Europe in two instances in 2021. We further discuss how the modes of the system provide information on which areas are more susceptible to lose synchrony with each other., M.M.-B., D.G., and P.C. acknowledge funding from the European Commission integrated action Virtual Power Plants for Islands, VPP4ISLANDS, (Grant Agreement No. 957852), from project APASOS PID2021-122256NB-C22 financed by MCIN/AEI/10.13039/501100011033/ and by EU through FEDER funds, and from Maria de Maeztu program CEX2021-001164-M of MCIN/AEI/10.13039/501100011033/. J.F. and P.J. acknowledge funding from the Swiss National Science Foundation under Grant No. 200020_182050., With funding from the Spanish government through the "María de Maeztu Unit of Excellence" accreditation (CEX2021-001164-M), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Reducing blackout risk by segmenting European power grid with HVDC lines

  • Gomila, Damià
  • Carreras, Benjamin A.
  • Reynolds-Barredo, José M.
  • Martínez Barbeito, María
  • Colet, Pere
  • Gomis-Bellmunt, O.
The utilization of high-voltage direct current (HVDC) lines for the segmentation of the European power grid has been demonstrated to be a highly effective strategy for the mitigation of the risk of cascading blackouts. In this study, an accurate and efficient method for determining the optimal power flow through HVDC lines is presented, with the objective of minimizing load shedding. The proposed method is applied to two distinct scenarios: first, the segmentation of the power grid along the Pyrenees, with the objective of segmenting the Iberian Peninsula from the rest of Europe; and second, the segmentation of the power grid into Eastern and Western Europe, approximately in half. In both scenarios, the method effectively reduces the size of blackouts impacting both sides of the HVDC lines, resulting in a 46% and 67% reduction in total blackout risk, respectively. Furthermore, we have estimated the cost savings from risk reduction and the expenses associated with converting conventional lines to HVDC lines. Our findings indicate that segmenting the European power grid with HVDC lines is economically viable, particularly for segmenting the Iberian Peninsula, due to its favorable cost-risk reduction ratio., This work was supported by MCIN/AEI/10.13039/501100011033 (No. PID2021-122256NB-C22, No. CEX2021-001164-M) and the European Union’s Horizon 2020 Research and Innovation Programme (Grant Agreement No. 957852, VPP4Islands). We acknowledge access to Uranus, a supercomputer cluster located at Universidad Carlos III de Madrid (Spain). Oriol Gomis-Bellmunt was supported in part by FI-AGAUR Research Fellowship Program, Generalitat de Catalunya, and the ICREA Academia program. This article is distributed under the terms of the Creative Commons Attribution 4.0 International License http://creativecommons.org/licenses/by/4.0/)., With funding from the Spanish government through the "María de Maeztu Unit of Excellence" accreditation (CEX2021-001164-M), Peer reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Reducing blackout risk by segmenting European power grid with HVDC lines

  • Gomila Villalonga, Damià Agustí
  • Carreras, Benjamín A.
  • Reynolds Barredo, Jose Miguel
  • Martínez Barbeito, María
  • Colet Rafecas, Pere
  • Gomis Bellmunt, Oriol|||0000-0002-9507-8278
The utilization of high-voltage direct current (HVDC) lines for the segmentation of the European power grid has been demonstrated to be a highly effective strategy for the mitigation of the risk of cascading blackouts. In this study, an accurate and efficient method for determining the optimal power flow through HVDC lines is presented, with the objective of minimizing load shedding. The proposed method is applied to two distinct scenarios: first, the segmentation of the power grid along the Pyrenees, with the objective of segmenting the Iberian Peninsula from the rest of Europe; and second, the segmentation of the power grid into Eastern and Western Europe, approximately in half. In both scenarios, the method effectively reduces the size of blackouts impacting both sides of the HVDC lines, resulting in a 46% and 67% reduction in total blackout risk, respectively. Furthermore, we have estimated the cost savings from risk reduction and the expenses associated with converting conventional lines to HVDC lines. Our findings indicate that segmenting the European power grid with HVDC lines is economically viable, particularly for segmenting the Iberian Peninsula, due to its favorable cost-risk reduction ratio., This work was supported by MCIN/AEI/10.13039/501100011033 (No. PID2021-122256NB-C22, No. CEX2021-001164-M) and the European Union’s Horizon 2020 Research and Innovation Programme (Grant Agreement No. 957852, VPP4Islands). We acknowledge access to Uranus, a supercomputer clus‐ ter located at Universidad Carlos III de Madrid (Spain). Oriol Gomis-Bellmunt was supported in part by FI-AGAUR Research Fellowship Program, Generalitat de Catalunya, and the ICREA Academia program., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Reducing blackout risk by segmenting European power grid with HVDC lines

  • Gomila Villalonga, Damià Agustí
  • Carreras, Benjamín A.
  • Reynolds Barredo, Jose Miguel
  • Martínez Barbeito, María
  • Colet Rafecas, Pere
  • Gomis Bellmunt, Oriol
The utilization of high-voltage direct current (HVDC) lines for the segmentation of the European power grid has been demonstrated to be a highly effective strategy for the mitigation of the risk of cascading blackouts. In this study, an accurate and efficient method for determining the optimal power flow through HVDC lines is presented, with the objective of minimizing load shedding. The proposed method is applied to two distinct scenarios: first, the segmentation of the power grid along the Pyrenees, with the objective of segmenting the Iberian Peninsula from the rest of Europe; and second, the segmentation of the power grid into Eastern and Western Europe, approximately in half. In both scenarios, the method effectively reduces the size of blackouts impacting both sides of the HVDC lines, resulting in a 46% and 67% reduction in total blackout risk, respectively. Furthermore, we have estimated the cost savings from risk reduction and the expenses associated with converting conventional lines to HVDC lines. Our findings indicate that segmenting the European power grid with HVDC lines is economically viable, particularly for segmenting the Iberian Peninsula, due to its favorable cost-risk reduction ratio., This work was supported by MCIN/AEI/10.13039/501100011033 (No. PID2021-122256NB-C22, No. CEX2021-001164-M) and the European Union’s Horizon 2020 Research and Innovation Programme (Grant Agreement No. 957852, VPP4Islands). We acknowledge access to Uranus, a supercomputer clus‐ ter located at Universidad Carlos III de Madrid (Spain). Oriol Gomis-Bellmunt was supported in part by FI-AGAUR Research Fellowship Program, Generalitat de Catalunya, and the ICREA Academia program., Peer Reviewed, Postprint (published version)