Pasar al contenido principal

CONTROL DE UNA RED DE MULTIPLES REDES AC Y DC INTERCONECTADAS CON CONVERTIDORES DE POTENCIA

RTI2018-095429-B-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2018
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSITAT POLITECNICA DE CATALUNYA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 17
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Otros (Other)

Reducing Blackout Risk by Segmenting the European Power Grid with Hvdc Lines

  • Gomila, Damià
  • Carreras, Benjamin A.
  • Reynolds-Barredo, José M.
  • Martínez-Barbeito, María
  • Colet, Pere
  • Gomis-Bellmunt, O.
Segmenting the continental Europe power grid using high-voltage direct-current (HVDC) lines can help in reducing the risk of cascading blackouts. In this work we present an accurate and efficient method to determine the power that must flow through these lines in order to minimize the load shed. As an example, the method is applied to the case where the European grid is segmented, first, through the Pyrenees separating the Iberian peninsula from the rest of Europe and, second, dividing the network in approximately two halves, Eastern and Western Europe. In both cases the method is very efficient in reducing the size of blackouts involving both sides of the HVDC lines. Globally, this reduction translates in a decrease of the total blackout risk of approximately 46% and 67% respectively. We estimate also the savings due to the risk reduction and the cost of converting the necessary conventional lines to HVDC. The results show that segmentation of the European grid using HVDC could be economically viable, specially the case of segmenting the Iberian peninsula, as the cost-risk reduction ratio is lower., DG and PC acknowledge funding from MCIN/AEI/10.13039/501100011033/FEDER/EU under project APASOS (PID2021-122256NB-C22) and from MCIN/AEI/10.13039/501100011033 under the Maria de Maeztu Program for units of Excellence in R&D CEX2021-001164-M, and also from the European Union’s Horizon 2020 research and innovation programme (Grant Agreement No. 957852, VPP4Islands). B.A.C. and J.M.R.-B. acknowledge access to Uranus, a supercomputer cluster located at Universidad Carlos III de Madrid (Spain) funded jointly by EU FEDER funds and by the Spanish Government via the National Research Project Nos. UNC313- 4E-2361, ENE2009-12213-C03-03, ENE2012-33219, and ENE2012-31753. OGB was supported in part by FEDER/Ministerio de Ciencia, Innovacion y Universidades - Agencia Estatal de Investigacion, Project RTI2018-095429-B-I00 and in part by FI-AGAUR Research Fellowship Program, Generalitat de Catalunya. The work of OGB is supported by the ICREA Academia program., With funding from the Spanish government through the "Severo Ochoa Centre of Excellence" accreditation (CEX2021-001164-M)., No
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

General form of consensus optimization for distributed OPF in HVAC-VSC-HVDC systems

  • Aragüés Peñalba, Mònica|||0000-0002-1509-376X
  • Nguyen, Tung Lam
  • Caire, Raphael
  • Sumper, Andreas|||0000-0002-5628-1660
  • Galceran Arellano, Samuel|||0000-0001-6378-0997
  • Tran, Quoc-Tuan
In this paper a distributed algorithm for ensuring Optimal Power Flows in hybrid AC-DC systems is proposed. While centralized OPF formulations require information of many variables of all the network nodes, the present approach relies on solving an OPF locally in each AC agent and AC-DC agent that only requires to exchange the voltages corresponding to adjacent nodes. Therefore, operation schemes based on this approach would be specially interesting when communications with the central unit fail. This algorithm is applied to a 3 DC - 5 AC bus system, showing that the obtained results coincide with those of the centralized formulation. Additionally, the dynamic behavior of this system operated under the proposed algorithm is analysed in a real-time platform in a realistic communication environment.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Unidirectional series interline DC/DC current flow controller for meshed HVDC grids

  • Sau Bassols, Joan|||0000-0001-6082-3875
  • Ferrer San José, Ricard|||0000-0001-9047-4397
  • Prieto Araujo, Eduardo|||0000-0003-4349-5923
  • Gomis Bellmunt, Oriol|||0000-0002-9507-8278
© 219 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., Meshed High Voltage Direct Current (HVDC) grids may require additional devices such as Current Flow Controllers (CFC) or Power Flow Controllers (PFC) that can control the DC currents in order to avoid overloads and bottlenecks. This paper studies the unidirectional series interline DC/DC CFC topology. Different control modes are considered for the aforementioned converter and it is validated through simulation results and a prototype is built and tested in an experimental platform in the laboratory., This work was supported by the Spanish Ministry of Science, Innovation and Universities under the Project RTI2018-095429-B-I00. This work was co-financed by the European Regional Development Fund. E. Prieto-Araujo is also a Serra Hunter Lecturer., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Methodology for interaction identification in modular multi-level converter-based HVDC systems

  • Dadjo Tavakoli, Saman
  • Prieto Araujo, Eduardo|||0000-0003-4349-5923
  • Sánchez Sánchez, Enric|||0000-0003-4075-0191
  • Gomis-Bellmunt, Oriol
This paper suggests a methodology for the identification, classification, and evaluation of various types of interactions that may occur in an HVDC link based on modular multi-level converters (MMC). The methodology incorporates the most suitable analytic tools for the frequency-domain study of each interaction category. To do so, a detailed nonlinear model of an MMC-based HVDC link that consists of master and slave MMCs, AC grids, and the DC transmission system is derived. Then, it is linearized to obtain a multi-input multi-output (MIMO) linear model that represents the dynamics of the complete MMC-based HVDC link. Based on the control loops of interest, interactions are classified as (1) state variable interactions, (2) disturbance interactions, (3) control loop interactions, and (4) overall system interactions. Then, through the application examples, the mentioned four categories of interactions are studied in frequency domain via the relevant analytic tools. The results obtained from the frequency-domain analysis are validated by time-domain simulation., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Optimal H-infinity control design for MMC-based HVDC links

  • Dadjo Tavakoli, Saman
  • Fekriasl, Sajjad
  • Prieto Araujo, Eduardo|||0000-0003-4349-5923
  • Beerten, Jef
  • Gomis Bellmunt, Oriol|||0000-0002-9507-8278
© 2021 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting /republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works, The modular multilevel converter (MMC) has emerged as the preferred choice for voltage source converter (VSC)-based high voltage direct current (HVDC) systems due to its low losses, low harmonic distortion, modularity, and redundancy. These advantages come at the expense of a complex control system with the strong coupling among its control variables, which complicates the design procedure of both its individual control loops and the DC link controllers. In fact, the performance improvement of a control loop could lead to degraded performance of other loops. Hence, to deal with such a complex dynamic system, this article suggests adopting multivariable H optimal control techniques in order to ensure stability and optimized performance of a VSC-HVDC link. First, a full-order, centralized multi-input-multi-output (MIMO) controller is derived based on H optimization and used as a benchmark for the system performance level. Then, a fixed-structure, decentralized MIMO controller is synthesized to make a compromise between the optimal performance and feasibility of practical implementation. Finally, simulations are conducted to evaluate and compare the performance and robustness degradation due to the migration from a high-order, centralized controller towards a low-order, decentralized controller., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Real-time optimization-based reference calculation integrated control for MMCs considering converter limitations

  • Westerman Spier, Daniel|||0000-0003-3477-6328
  • Rodríguez Bernuz, Joan Marc|||0000-0003-4503-379X
  • Prieto Araujo, Eduardo|||0000-0003-4349-5923
  • López Mestre, Joaquim
  • Junyent Ferré, Adrià
  • Gomis Bellmunt, Oriol|||0000-0002-9507-8278
© 2021 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting /republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works, The paper addresses a real-time optimization-based reference calculation integrated with a control structure for Modular Multilevel Converters (MMC) operating under normal and constrained situations (where it has reached current and/or voltage limitations, e.g. during system faults). The algorithm prioritizes to satisfy the Transmission System Operators (TSO) AC grid current demanded set-points. The constrained optimization problem is formulated based on the steady-state model of the MMC, whereby the prioritization is achieved through distinct weights defined in the Objective Function’s (OF) terms. The resultant optimization problem, however, is highly nonlinear requiring high computation burden to be solved in real-time. To overcome this issue, this paper applies a Linear Time-Varying (LTV) approximation, where the nonlinear dynamics of the system are represented as constant parameters, while a Linear Time-Invariant (LTI) system is used to formulate the optimization constraints. The converter's current references are determined in real-time by solving a constrained linearized optimization problem at each control time step, considering the TSO's demands, the current MMC operating point and its physical limitations. Finally, the linearized-optimization problem is integrated with the MMC controllers and evaluated under different network conditions, where the results indicated that method can be potentially employed to obtain the MMCs current references., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Steady-state impedance mapping in grids with power electronics: What is grid strength in modern power systems?

  • Gomis Bellmunt, Oriol|||0000-0002-9507-8278
  • Song, Jie
  • Cheah Mañé, Marc|||0000-0002-0942-661X
  • Prieto Araujo, Eduardo|||0000-0003-4349-5923
The paper analyzes grid strength and grid impedance for systems with significant penetration of power electronics. The work shows that the traditionally employed Thévenin equivalent cannot capture the different saturation states of power converters and therefore some classical definitions of grid strength based on short-circuit power at the point of connection fail to describe the system behavior. The paper proposes to map the impedance for all the different possible voltages at the point of connection and analyzes how the impedance depend on the voltage and angle of derivation for different possible simplified systems (grid-following converter in parallel with a Thévenin equivalent and grid-forming converter) considering the different saturation states of the converter. Numerical results and case studies are included as examples of the conducted analysis., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Modelling and experimental validation of a laboratory-scaled HVDC cable emulator tested in an MMC-based platform

  • Sánchez Sánchez, Enric|||0000-0003-4075-0191
  • Junyent Ferré, Adrià
  • Prieto Araujo, Eduardo|||0000-0003-4349-5923
  • Gomis Bellmunt, Oriol|||0000-0002-9507-8278
  • Green, T.
© 2020 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., Typical Modular Multilevel Converter (MMC)-based HVDC systems don't include capacitors directly connected to the DC-side in parallel with the HVDC lines. The dynamics of the HVDC line voltage depend on the equivalent capacitance of the HVDC system, which in turn depends on the length of the lines. Recent work in the literature has shown that this can become problematic for HVDC line voltage control in the case of short links. This paper describes the operation of a laboratory-scaled MMC-based HVDC short link platform devised to study this phenomenon. Special emphasis is put on the design and the scaling of a frequency-dependent cable emulator. Experimental results are compared with a benchmark high-voltage simulated model., This work was funded by the EPSRC Centre for Power Electronics Researcher Exchange Scheme, the FI-AGAUR Research Fellowship Program, the FEDER/Ministerio de Ciencia, Innovación y Universidades -Agencia Estatal de Investigación (RTI2018-095429- B- I00), and the Serra Húnter and ICREA Academia programs. The work was also supported by the European Regional Development Fund (ERDF)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Dc voltage droop control design for mmc-based multiterminal hvdc grids

  • Dadjo Tavakoli, Saman
  • Sánchez Sánchez, Enric|||0000-0003-4075-0191
  • Prieto Araujo, Eduardo|||0000-0003-4349-5923
  • Gomis Bellmunt, Oriol|||0000-0002-9507-8278
© 2020 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting /republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to, This article addresses the design of the DC voltage droop control in modular multilevel converter (MMC)-based multiterminal HVDC grids. First, two energy-based control approaches, namely classic and cross control, are explored for the implementation of the voltage-power droop controller. The cross control, as the better solution for droop implementation, is further improved, making it more robust against disturbances. Then, a methodology is derived to select the droop gain combinations considering the AC grid, DC grid and MMC dynamics and their limitations. The methodology is based on a linear analysis to identify the valid droop gains which comply with the limits imposed on: the transient power sharing among MMCs, the DC grid voltage, the MMC AC and DC currents, the total MMC stored energy, and the stability margin of the complete multiterminal HVDC grid. Finally, time-domain simulations are conducted using the nonlinear model to validate the dynamic performance of the selected droop combinations obtained from the suggested methodology., Peer Reviewed, Objectius de Desenvolupament Sostenible::7 - Energia Assequible i No Contaminant
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Modelling and experimental validation of a laboratory-scaled HVDC cable emulator tested in an MMC-based platform

  • Sánchez Sánchez, Enric
  • Junyent Ferré, Adrià
  • Prieto Araujo, Eduardo
  • Gomis Bellmunt, Oriol
  • Green, T.
© 2020 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., Typical Modular Multilevel Converter (MMC)-based HVDC systems don't include capacitors directly connected to the DC-side in parallel with the HVDC lines. The dynamics of the HVDC line voltage depend on the equivalent capacitance of the HVDC system, which in turn depends on the length of the lines. Recent work in the literature has shown that this can become problematic for HVDC line voltage control in the case of short links. This paper describes the operation of a laboratory-scaled MMC-based HVDC short link platform devised to study this phenomenon. Special emphasis is put on the design and the scaling of a frequency-dependent cable emulator. Experimental results are compared with a benchmark high-voltage simulated model., This work was funded by the EPSRC Centre for Power Electronics Researcher Exchange Scheme, the FI-AGAUR Research Fellowship Program, the FEDER/Ministerio de Ciencia, Innovación y Universidades -Agencia Estatal de Investigación (RTI2018-095429- B- I00), and the Serra Húnter and ICREA Academia programs. The work was also supported by the European Regional Development Fund (ERDF)., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Methodology for interaction identification in modular multi-level converter-based HVDC systems

  • Dadjo Tavakoli, Saman
  • Prieto Araujo, Eduardo
  • Sánchez Sánchez, Enric
  • Gomis-Bellmunt, Oriol
This paper suggests a methodology for the identification, classification, and evaluation of various types of interactions that may occur in an HVDC link based on modular multi-level converters (MMC). The methodology incorporates the most suitable analytic tools for the frequency-domain study of each interaction category. To do so, a detailed nonlinear model of an MMC-based HVDC link that consists of master and slave MMCs, AC grids, and the DC transmission system is derived. Then, it is linearized to obtain a multi-input multi-output (MIMO) linear model that represents the dynamics of the complete MMC-based HVDC link. Based on the control loops of interest, interactions are classified as (1) state variable interactions, (2) disturbance interactions, (3) control loop interactions, and (4) overall system interactions. Then, through the application examples, the mentioned four categories of interactions are studied in frequency domain via the relevant analytic tools. The results obtained from the frequency-domain analysis are validated by time-domain simulation., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Real-time optimization-based reference calculation integrated control for MMCs considering converter limitations

  • Westerman Spier, Daniel
  • Rodríguez Bernuz, Joan Marc
  • Prieto Araujo, Eduardo
  • López Mestre, Joaquim
  • Junyent Ferré, Adrià
  • Gomis Bellmunt, Oriol
© 2021 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting /republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works, The paper addresses a real-time optimization-based reference calculation integrated with a control structure for Modular Multilevel Converters (MMC) operating under normal and constrained situations (where it has reached current and/or voltage limitations, e.g. during system faults). The algorithm prioritizes to satisfy the Transmission System Operators (TSO) AC grid current demanded set-points. The constrained optimization problem is formulated based on the steady-state model of the MMC, whereby the prioritization is achieved through distinct weights defined in the Objective Function’s (OF) terms. The resultant optimization problem, however, is highly nonlinear requiring high computation burden to be solved in real-time. To overcome this issue, this paper applies a Linear Time-Varying (LTV) approximation, where the nonlinear dynamics of the system are represented as constant parameters, while a Linear Time-Invariant (LTI) system is used to formulate the optimization constraints. The converter's current references are determined in real-time by solving a constrained linearized optimization problem at each control time step, considering the TSO's demands, the current MMC operating point and its physical limitations. Finally, the linearized-optimization problem is integrated with the MMC controllers and evaluated under different network conditions, where the results indicated that method can be potentially employed to obtain the MMCs current references., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Optimal H-infinity control design for MMC-based HVDC links

  • Dadjo Tavakoli, Saman
  • Fekriasl, Sajjad
  • Prieto Araujo, Eduardo
  • Beerten, Jef
  • Gomis Bellmunt, Oriol
© 2021 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting /republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works, The modular multilevel converter (MMC) has emerged as the preferred choice for voltage source converter (VSC)-based high voltage direct current (HVDC) systems due to its low losses, low harmonic distortion, modularity, and redundancy. These advantages come at the expense of a complex control system with the strong coupling among its control variables, which complicates the design procedure of both its individual control loops and the DC link controllers. In fact, the performance improvement of a control loop could lead to degraded performance of other loops. Hence, to deal with such a complex dynamic system, this article suggests adopting multivariable H optimal control techniques in order to ensure stability and optimized performance of a VSC-HVDC link. First, a full-order, centralized multi-input-multi-output (MIMO) controller is derived based on H optimization and used as a benchmark for the system performance level. Then, a fixed-structure, decentralized MIMO controller is synthesized to make a compromise between the optimal performance and feasibility of practical implementation. Finally, simulations are conducted to evaluate and compare the performance and robustness degradation due to the migration from a high-order, centralized controller towards a low-order, decentralized controller., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Unidirectional series interline DC/DC current flow controller for meshed HVDC grids

  • Sau Bassols, Joan
  • Ferrer San José, Ricard
  • Prieto Araujo, Eduardo
  • Gomis Bellmunt, Oriol
© 219 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., Meshed High Voltage Direct Current (HVDC) grids may require additional devices such as Current Flow Controllers (CFC) or Power Flow Controllers (PFC) that can control the DC currents in order to avoid overloads and bottlenecks. This paper studies the unidirectional series interline DC/DC CFC topology. Different control modes are considered for the aforementioned converter and it is validated through simulation results and a prototype is built and tested in an experimental platform in the laboratory., This work was supported by the Spanish Ministry of Science, Innovation and Universities under the Project RTI2018-095429-B-I00. This work was co-financed by the European Regional Development Fund. E. Prieto-Araujo is also a Serra Hunter Lecturer., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Steady-state impedance mapping in grids with power electronics: What is grid strength in modern power systems?

  • Gomis Bellmunt, Oriol
  • Song, Jie
  • Cheah Mañé, Marc
  • Prieto Araujo, Eduardo
The paper analyzes grid strength and grid impedance for systems with significant penetration of power electronics. The work shows that the traditionally employed Thévenin equivalent cannot capture the different saturation states of power converters and therefore some classical definitions of grid strength based on short-circuit power at the point of connection fail to describe the system behavior. The paper proposes to map the impedance for all the different possible voltages at the point of connection and analyzes how the impedance depend on the voltage and angle of derivation for different possible simplified systems (grid-following converter in parallel with a Thévenin equivalent and grid-forming converter) considering the different saturation states of the converter. Numerical results and case studies are included as examples of the conducted analysis., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

General form of consensus optimization for distributed OPF in HVAC-VSC-HVDC systems

  • Aragüés Peñalba, Mònica
  • Nguyen, Tung Lam
  • Caire, Raphael
  • Sumper, Andreas
  • Galceran Arellano, Samuel
  • Tran, Quoc-Tuan
In this paper a distributed algorithm for ensuring Optimal Power Flows in hybrid AC-DC systems is proposed. While centralized OPF formulations require information of many variables of all the network nodes, the present approach relies on solving an OPF locally in each AC agent and AC-DC agent that only requires to exchange the voltages corresponding to adjacent nodes. Therefore, operation schemes based on this approach would be specially interesting when communications with the central unit fail. This algorithm is applied to a 3 DC - 5 AC bus system, showing that the obtained results coincide with those of the centralized formulation. Additionally, the dynamic behavior of this system operated under the proposed algorithm is analysed in a real-time platform in a realistic communication environment., Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Dc voltage droop control design for mmc-based multiterminal hvdc grids

  • Dadjo Tavakoli, Saman
  • Sánchez Sánchez, Enric
  • Prieto Araujo, Eduardo
  • Gomis Bellmunt, Oriol
© 2020 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting /republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to, This article addresses the design of the DC voltage droop control in modular multilevel converter (MMC)-based multiterminal HVDC grids. First, two energy-based control approaches, namely classic and cross control, are explored for the implementation of the voltage-power droop controller. The cross control, as the better solution for droop implementation, is further improved, making it more robust against disturbances. Then, a methodology is derived to select the droop gain combinations considering the AC grid, DC grid and MMC dynamics and their limitations. The methodology is based on a linear analysis to identify the valid droop gains which comply with the limits imposed on: the transient power sharing among MMCs, the DC grid voltage, the MMC AC and DC currents, the total MMC stored energy, and the stability margin of the complete multiterminal HVDC grid. Finally, time-domain simulations are conducted using the nonlinear model to validate the dynamic performance of the selected droop combinations obtained from the suggested methodology., Peer Reviewed, Objectius de Desenvolupament Sostenible::7 - Energia Assequible i No Contaminant, Postprint (published version)