Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Development of Potentiometric Sensors for C2H4 Detection

  • Toldrá-Reig, Fidel|||0000-0001-6133-7043
  • Serra Alfaro, José Manuel|||0000-0002-1515-1106
[EN] Gas exhaust emissions in vehicles are increasingly restrictive in EU and USA. Diesel engines are particularly affected by limitation in hydrocarbons and NOx concentrations. This work presents a screening of working electrode materials to develop a potentiometric sensor, with the most promising material to detect being C2H4 at 550 degrees C. The device consists of a dense 8YSZ (8 mol% Y2O3 stabilized ZrO2) disk as oxide-ion conducting electrolyte, whereas platinum is screen-printed in the back face as reference electrode. As working electrode, several materials such as Fe0.7Cr1.3O3, ZnCr2O4, Fe2NiO4, La0.8Sr0.2CrO3- (LSC), La0.8Sr0.2MnO3 (LSM), and NiO+5%wt Au were tested to detect C2H4. Sensor voltage was measured for several concentrations of C2H4 and CO as these are two of the major oxidizable compounds in a diesel exhaust gas. Fe0.7Cr1.3O3 was selected as the most promising material because of its response to C2H4 and CO. Not only is the response to the individual analytes important, but the C2H4 cross-sensitivity toward CO is also important. Fe0.7Cr1.3O3 showed a good performance to C2H4, with low cross-sensitivity to CO. In addition, when 0.16 ppm of phenanthrene is added, the sensor still has a slightly better response to C2H4 than to CO. Nevertheless, the sensor exposure to high concentrations (>85 ppm) of polycyclic aromatic hydrocarbons led to signal saturation. On the other hand, the operation in wet conditions induces lower sensor sensitivity to C2H4 and higher cross-sensitivity toward CO increase, i.e., the sensor response becomes similar for C2H4 and CO., This research was funded by Spanish government (AP-2003-03478, SEV-2016-0683 and ENE2014-57651).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Surface Functionalization with Ni of Fe0.7Cr1.3O3/8YSZ Electrode in a Potentiometric Sensor To Selectively Detect C2H4

  • Toldrá-Reig, Fidel|||0000-0001-6133-7043
  • Serra Alfaro, José Manuel|||0000-0002-1515-1106
[EN] This work presents a multidevice potentiometric sensor consisting of Fe0.7Cr1.3O3/8YSZ//8YSZ//Pt to detect selectively C2H4 with a low cross-sensitivity to CO in diesel exhaust gases. The device has been designed as a multisensor to measure up to four channels at the same time. A dense 8YSZ disk is employed as oxide-ion conducting electrolyte where four rectangular-shape working electrodes (Fe0.7Cr13O3/8YSZ) are screen-printed in one face while one common cross-shape reference electrode (LSM/8YSZ) is screen printed in the back face. Two major improvements are proposed in this work: first, change the reference electrode from state-of-the-art Pt to LSM/8YSZ, inexpensive and more active to oxygen. And second, increase the catalytic activity of the working electrode to improve the response of the sensor under wet conditions. The surface activation by nickel and ruthenium nanoparticles deposition enables reduction of the cross-sensitivity toward CO even in wet atmospheres. Ni nanoparticles selectively boost the electrochemically driven oxidation to C2H4 with respect to CO oxidation, as inferred by impedance spectroscopy analysis, Funding from Spanish Government (Grants AP-2003-03478, SEV-2016-0683, and ENE2014-57651) is kindly acknowledged. FPU scholarship to F.T.-R. from the Spanish Ministry of Education, Culture and Sport is also acknowledged.