NUEVAS METODOLOGIAS ANALITICAS ECOLOGICAS: AVANCES EN LA MICROEXTRACCION LIQUIDO-LIQUIDO Y EN SUS SISTEMAS DE DETECCION

BES-2012-058759

•
Nombre agencia financiadora Ministerio de Ciencia e Innovación
Acrónimo agencia financiadora MICINN
Programa Programa Nacional de Formación de Personal Investigador
Subprograma Subprograma de Ayudas de Formación de Personal Investigador
Convocatoria Contratos Predoctorales
Año convocatoria 2012
Plan Estatal 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Unidad de gestión Secretaría de Estado de Educación, Formación Profesional y Universidades
Centro beneficiario UNIVERSIDAD DE ALICANTE
Identificador persistente http://dx.doi.org/10.13039/501100004837

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Evaluation of electrosprayed graphene oxide coatings for elemental analysis by thin film microextraction followed by Laser-induced Breakdown Spectroscopy detection

  • Ripoll-Seguer, Laura
  • Legnaioli, Stefano
  • Palleschi, Vincenzo
  • Hidalgo, Montserrat
  • Hidalgo, Montserrat|||/items/8c122b2d-4d92-45f3-ad75-e863e4e18750
In this work, a solid phase microextraction procedure, denoted as Thin Film Microextraction (TFME), was combined with Laser-induced Breakdown Spectroscopy for the detection of several analytes in aqueous solutions (Cu, Cr, Ni and Pb). The adsorbent films, consisting of a thin layer of graphene oxide deposited on glass substrates, were generated by using the electrospray deposition technique (ESD). Several parameters affecting the quality and shape of the films resulting from the ESD process were studied, and the morphology and adsorption capacity of the films were evaluated. The generated films were used for extraction of the target analytes from aqueous solutions and, after extraction, the analytes-enriched adsorbents were analysed by LIBS without the need of any desorption or elution step. In order to assess the analytical capability of the TFME-LIBS procedure, different analytical figures of merit of the proposed TFME-LIBS methodology were evaluated. The obtained limits of detection were 14 μg kg−1 for Pb and 15 μg kg−1 for the rest of the tested analytes. Measurement repeatability was better than 4% RSD at low concentration level (20 μg kg−1) but deteriorated by increasing the concentration level at 100 μg kg−1, with %RSD ranging from 3.6% (Cr) to 24% (Pb). Method trueness, evaluated from the analysis of a real sample of bottled water, led to recovery values in the range 85%–106%.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Electrospray deposition followed by laser-induced breakdown spectroscopy (ESD-LIBS): a new method for trace elemental analysis of aqueous samples

  • Ripoll-Seguer, Laura
  • Hidalgo, Montserrat
  • Hidalgo, Montserrat|||/items/8c122b2d-4d92-45f3-ad75-e863e4e18750
The combination of electrospray deposition with laser-induced breakdown spectroscopy (ESD-LIBS) was investigated as a potential approach to the detection and quantification of Zn, Cd, Cr and Ni, at trace levels, in aqueous samples. In this analytical procedure, the aqueous samples were first converted into solids in an electrospray system. To this end, micro-volumes of liquids were electro-sprayed onto a heated substrate, leading to the generation of solid residues. Afterwards, the as-obtained residues were analysed by LIBS. Three calibration methodologies were tested with the proposed ESD-LIBS methodology, namely external calibration, conventional standard addition calibration and on-line standard addition calibration. In all cases, the analytical features of the ESD-LIBS method were assessed. The obtained limits of detection ranged from 9 μg kg−1 to 57 μg kg−1, depending on the element and on the calibration modality used. Method trueness, evaluated from the analysis of a real sample of tap water, was highly dependent on the calibration method. The use of external calibration led to recovery values in the range of 18–123%, indicating the existence of strong matrix effects. This drawback was overcome with the application of conventional standard addition and on-line standard addition calibration modalities, for which recovery values were improved to the ranges 91–110% and 90–105%, respectively. Among them, the use of on-line standard addition provides a sensitive and accurate methodology with possibilities of automation.