Pasar al contenido principal

NUEVAS APLICACIONES DE NANOMATERIALES (MATERIALES EN BASE CARBONO Y ZEOLITAS) COMO SORBENTES EN TECNICAS DE MICROEXTRACCION EN FASE SOLIDA

CTQ2016-79991-R

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2016
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE ALICANTE

Resultados relacionados

Resultados totales (Incluyendo duplicados): 13
Encontrada(s) 1 página(s)

RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Vitamin E determination in edible oils by reversed-phase dispersive liquid-liquid microextraction and screen-printed carbon electrodes

  • Diuzheva, Alina
  • Fernández Martínez, Elena
  • Vidal, Lorena
  • Andruch, Vasil
  • Canals, Antonio
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Vidal, Lorena|||/items/87ae49dd-73c8-41be-9c0c-2d3c37772793
A novel simple, environmentally friendly and portable method to determine vitamin E in edible oils based on reversed-phase dispersive liquid-liquid microextraction combined with electrochemical detection using screen-printed carbon electrodes (SPCEs) has been developed. Vitamin E was extracted from oil samples into a 4 M HCl aqueous solution and determined by differential pulse voltammetry using SPCEs. The extraction conditions optimized by experimental design (i.e., Plackett-Burman and central composite designs) were: aqueous 4 M HCl extractant volume, 43 µL; extraction time, 2 min; centrifugation time, 10 min; and centrifugation speed, 3000 rpm. The proposed method requires a standard addition calibration approach, and the working range showed good linearity from 0 to 20 mg L−1, with a correlation coefficient ranging from 0.990 to 0.995 (N=5). The methodological limit of detection was between 1 and 3 mg L−1. The repeatability of the proposed method was evaluated at 15 mg L−1, and the relative standard deviation ranged between 10 and 15% (n=5). For the quantification of vitamin E in ten commercial samples of olive, sesame, soybean, sunflower and a mixture of sunflower and corn oils, the volume of the extractant phase (i.e., 4 M HCl aqueous solution) was increased up to 100 µL and satisfactory recoveries were obtained in the range of 85-115%, confirming the applicability of the method.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

A new multinebulizer for spectrochemical analysis: wear metal determination in used lubricating oils by on-line standard dilution analysis (SDA) using inductively coupled plasma optical emission spectrometry (ICP OES)

  • García, Miriam
  • Aguirre Pastor, Miguel Ángel
  • Canals, Antonio
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
A new multinebulizer has been employed for wear metal (e.g., Cd, Cr, Cu, Fe, Mn, Ni, and Pb) determination in used lubricating oils. To this end, a multinebulizer-based analytical methodology combined with on-line standard dilution analysis (on-line SDA) and inductively coupled plasma optical emission spectrometry (ICP OES) (multinebulizer/SDA/ICP OES) has been proposed, which is able to overcome typical limitations related to organic sample analysis by ICP-based techniques. This is accomplished by the simultaneous introduction of organic samples and aqueous calibration standards, with a minimal sample pretreatment (i.e., dilution). The multinebulizer/SDA/ICP OES combination allows the determination of Cd, Cr, Cu, Fe, Mn, Ni and Pb in used lubricating oils with a limit of detection of 20, 10, 6, 20, 4, 30 and 200 ng g−1, respectively. The subsequent analysis of spiked commercial lubricating oil samples has led to recovery values which range from 91 to 108%. The efficiency of the proposed methodology has been checked by comparing its results with values obtained with conventional standard addition calibration and both limits of detection and recovery values were of the same order of magnitude. The proposed analytical methodology has the main advantage of ease of operation, as time and cost of analysis are reduced and the use of organic calibration standards is also avoided. Hence, the synergistic association multinebulizer/SDA is a simple, fast, relatively economic, environmentally friendly, direct and reliable method of wear metal monitoring in used lubricating oils by ICP OES.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Metal applications of liquid-phase microextraction

  • Aguirre Pastor, Miguel Ángel
  • Baile, Paola
  • Vidal, Lorena
  • Canals, Antonio
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Vidal, Lorena|||/items/87ae49dd-73c8-41be-9c0c-2d3c37772793
This review focuses on the combination of elemental detection techniques with liquid-phase microextraction (LPME), namely, single drop microextraction, hollow fiber based liquid-phase microextraction, dispersive liquid-liquid microextraction, and related techniques. General features of different microextraction procedures, historical overview and automation of LPME are described and compared, along with examples of new developments and applications presented to demonstrate its potential for trace and ultra-trace metal analysis. Furthermore, potential applications and an outlook on the combination of LPME and elemental detection techniques for inorganic analysis are presented.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Evaluation of electrosprayed graphene oxide coatings for elemental analysis by thin film microextraction followed by Laser-induced Breakdown Spectroscopy detection

  • Ripoll-Seguer, Laura
  • Legnaioli, Stefano
  • Palleschi, Vincenzo
  • Hidalgo, Montserrat
  • Hidalgo, Montserrat|||/items/8c122b2d-4d92-45f3-ad75-e863e4e18750
In this work, a solid phase microextraction procedure, denoted as Thin Film Microextraction (TFME), was combined with Laser-induced Breakdown Spectroscopy for the detection of several analytes in aqueous solutions (Cu, Cr, Ni and Pb). The adsorbent films, consisting of a thin layer of graphene oxide deposited on glass substrates, were generated by using the electrospray deposition technique (ESD). Several parameters affecting the quality and shape of the films resulting from the ESD process were studied, and the morphology and adsorption capacity of the films were evaluated. The generated films were used for extraction of the target analytes from aqueous solutions and, after extraction, the analytes-enriched adsorbents were analysed by LIBS without the need of any desorption or elution step. In order to assess the analytical capability of the TFME-LIBS procedure, different analytical figures of merit of the proposed TFME-LIBS methodology were evaluated. The obtained limits of detection were 14 μg kg−1 for Pb and 15 μg kg−1 for the rest of the tested analytes. Measurement repeatability was better than 4% RSD at low concentration level (20 μg kg−1) but deteriorated by increasing the concentration level at 100 μg kg−1, with %RSD ranging from 3.6% (Cr) to 24% (Pb). Method trueness, evaluated from the analysis of a real sample of bottled water, led to recovery values in the range 85%–106%.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Determination of cadmium in used engine oil, gasoline and diesel by electrothermal atomic absorption spectrometry using magnetic ionic liquid-based dispersive liquid-liquid microextraction

  • Aguirre Pastor, Miguel Ángel
  • Canals, Antonio
  • López-García, Ignacio
  • Hernández-Córdoba, Manuel
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
In this study, a sensitive and matrix-effect free analytical method for Cd determination in engine oils and fuel samples by dispersive liquid-liquid microextraction with electrothermal atomic absorption spectrometry has been successfully developed. The extractant solvent used for the microextraction procedure was a magnetic ionic liquid (MIL) (i.e., bis(1-ethyl-3-methylimidazolium) tetrathiocyanatocobaltate (II) [Emim]2[Co(SCN)4]), which presents a paramagnetic property, and allows an easy phase separation using a magnet. In order to eliminate the well-known drawbacks of direct introduction of MIL in the graphite furnace, a back-extraction procedure was performed to transfer the analyte into an aqueous phase. The main experimental factors affecting the extraction of Cd (i.e., amount of sample and MIL, extraction and back-extraction time and concentration and amount of nitric acid) were optimized using a multivariate analysis consisting in two steps: a Plackett-Burman design followed by a circumscribed central composite design. Under optimum conditions (i.e., amount of sample: 6.2 g; amount of MIL: 119 mg; extraction time: 1 min; amount of nitric acid: 200 mg; nitric acid concentration: 1 mol L-1 and back-extraction time: 1 min), the proposed analytical method was validated and successfully used to analyze three real-world samples (i.e., used engine oil, gasoline and diesel). The three samples were spiked at two levels (i.e., 10 and 20 μg kg-1 of Cd for used engine oil and 1 and 3 μg kg-1 of Cd for gasoline and diesel). RSD and recovery values were within the range of 6–11% and 95–110%, respectively.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Determination of four bisphenols in water and urine samples by magnetic dispersive solid‐phase extraction using a modified zeolite/iron oxide composite prior to liquid chromatography diode array detection

  • Baile, Paola
  • Medina, Juan
  • Vidal, Lorena
  • Canals, Antonio
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Vidal, Lorena|||/items/87ae49dd-73c8-41be-9c0c-2d3c37772793
A novel approach is presented to determine four bisphenols in water and urine samples, employing magnetic dispersive solid‐phase extraction combined with liquid chromatography and diode array detection. A modified zeolite‐based magnetic composite was used as an efficient sorbent, combining the advantages of magnetic materials with the remarkable properties of zeolites. A multivariate optimization design was employed to optimize some experimental factors affecting magnetic dispersive solid‐phase extraction. The method was evaluated under optimized conditions (i.e., amount of sorbent, 50 mg; sample pH, unadjusted; NaCl concentration, 1.25%; extraction and elution time, 2 min; eluent solvent, ethanol; eluent solvent volume, 400 µL), obtaining good linearity with correlation coefficients ranging between 0.995 and 0.999 (N = 5) (from 2 to 250 µg/L for bisphenol A, bisphenol AP, and bisphenol P and from 5 to 250 µg/L for bisphenol AF). Method repeatability was assessed obtaining coefficients of variation between 3 and 11% (n = 6). Finally, the method was applied to spiked real samples, obtaining for water samples relative recoveries between 83 and 105%, and for urine samples between 81 and 108% for bisphenol A, bisphenol AP, and bisphenol AF, and between 47 and 59% for bisphenol P.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Graphene thin film microextraction and nanoparticle enhancement for fast LIBS metal trace analysis in liquids

  • Poggialini, Francesco
  • Campanella, Beatrice
  • Palleschi, Vincenzo
  • Hidalgo, Montserrat
  • Legnaioli, Stefano
  • Hidalgo, Montserrat|||/items/8c122b2d-4d92-45f3-ad75-e863e4e18750
Several strategies have been effectively tested in the past to improve the Laser Induced Breakdown Spectroscopy (LIBS) signal for the analysis of liquid samples, involving peculiar experimental configurations, such as Double Pulse LIBS (DP-LIBS). Recently, sample treatment has proven to be a viable and simple way to enhance the performances of LIBS towards the analysis of solutions. Among the various strategies, the most promising and versatile appears to be Thin Film Microextraction (TFME) using carbon-based adsorbents. Another sample pre-treatment procedure, Nanoparticle-Enhanced LIBS (NELIBS), has gained significant interest due to its relative simplicity and effectiveness. This methodology uses a deposition of silver nanoparticles (AgNPs) on the sample to greatly increase the emission of the LIBS plasma. In this work, we investigate for the first time the possibility of combining TFME and NELIBS. We developed TFME supports by depositing an aqueous graphene nano-sheets (aq-GRA) prepared by Pulsed Laser Ablation in Liquid (PLAL) on a glass substrate. The preparation of the supports was optimized with regards to the substrate nature, deposition method, sorbent volume and drying method. Then, the TFME supports were tested for the extraction of Chromium from aqueous solution at different extraction times and analyte concentration. Subsequently, the TFME supports were treated with a deposition of silver nanoparticles (AgNP) to test the feasibility of the NELIBS approach. We observed an enhancement in the emission lines of Cr when the AgNPs were applied, as well as a lower estimated LOD value when compared to plain graphene TFME supports.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Magnetic dispersive solid-phase extraction using a zeolite-based composite for direct electrochemical determination of lead(II) in urine using screen-printed electrodes

  • Fernández Martínez, Elena
  • Vidal, Lorena
  • Silvestre-Albero, Joaquín
  • Canals, Antonio
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Silvestre-Albero, Joaquín|||/items/340b8128-2e1e-4869-8845-03b1802a1577
  • Vidal, Lorena|||/items/87ae49dd-73c8-41be-9c0c-2d3c37772793
Magnetic dispersive solid-phase extraction (MDSPE) is combined with electrochemical detection by using a screen-printed carbon electrode modified with gold nanoparticles to determine lead(II). A zeolite-based magnetic composite was used as sorbent during sample preparation, thus combining the unique properties of zeolites as sorbent materials with the remarkable advantages provided by magnetic materials. Three different zeolite-based magnetic composites were initially investigated and characterized. ZSM-5/Fe2O3 treated with HNO3 (ZSM-5/Fe2O3(tr)) was finally selected as sorbent. Lead was extracted from urine samples using ZSM-5/Fe2O3(tr). After extraction, the phases were separated by using an external magnet. Subsequently, the magnetic composite carrying the analyte was directly deposited onto the working electrode of a modified screen-printed carbon electrode for final electrochemical detection. Thereby, the elution and detection of Pb(II) were carried out in a single step. A multivariate approach was employed to optimize the experimental parameters affecting extraction. Under optimized conditions and at a typical working potential of −0.23 V (vs. Ag pseudo-reference electrode), response is linear in the 0 to 25 μg L−1 Pb(II) concentration range. The empirical limit of detection ranged from 1.0 to 2.0 μg L−1. The method was used to analyze Pb(II)-spiked urine samples, and apparent recoveries ranged between 99 and 107%, with coefficients of variation of <20%.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

A modified zeolite/iron oxide composite as a sorbent for magnetic dispersive solid-phase extraction for the preconcentration of nonsteroidal anti-inflammatory drugs in water and urine samples

  • Baile, Paola
  • Vidal, Lorena
  • Canals, Antonio
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Vidal, Lorena|||/items/87ae49dd-73c8-41be-9c0c-2d3c37772793
This study is the first to use a new ZSM-5 zeolite-based composite decorated with iron oxide magnetic nanoparticles and modified with hexadecyltrimethylammonium bromide surfactant (i.e., HDTMA-ZSM-5/Fe2O3) as an efficient sorbent for magnetic dispersive solid-phase extraction (MDSPE) of nonsteroidal anti-inflammatory drugs in water and urine samples with subsequent measurement by liquid chromatography diode array detection. Experimental factors affecting MDSPE were optimized using a multivariate optimization strategy. The optimum experimental conditions were: amount of sorbent, 40 mg; sample pH, 2.2; NaCl concentration, 2.5%; extraction time, 2 min; eluent solvent, methanol; eluent solvent volume, 424 μL; and elution time, 2 min. The linearity of the method was studied from 3.3 to 400 μg L−1 (N = 8) for ketoprofen, from 1.7 to 400 μg L−1 (N = 8) for felbinac, from 6.6 to 400 μg L−1 (N = 7) for diclofenac and from 9.9 to 400 μg L−1 (N = 6) for ibuprofen. Method repeatability was evaluated at 10 and 200 μg L−1 spiking levels, obtaining coefficients of variation between 2 and 5% (n = 6). Limits of detection, determined empirically, were 1.0 μg L−1 , 0.5 μg L−1, 2.0 μg L−1 and 3.0 μg L−1 for ketoprofen, felbinac, diclofenac and ibuprofen, respectively. Tap water, reservoir water, wastewater and five urine samples were selected to assess method applicability. Recovery values ranged between 86–107% and 80–112% for water and urine samples, respectively, showing negligible matrix effects. Finally, this method was employed to monitor ibuprofen excretion in real urine samples.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Magnetic dispersive solid-phase extraction using ZSM-5 zeolite/Fe2O3 composite coupled with screen-printed electrodes based electrochemical detector for determination of cadmium in urine samples

  • Baile, Paola
  • Vidal, Lorena
  • Canals, Antonio
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Vidal, Lorena|||/items/87ae49dd-73c8-41be-9c0c-2d3c37772793
A novel, simple, fast, sensitive and environmentally friendly approach is presented to determine cadmium in urine samples, combining magnetic dispersive solid-phase extraction (MDSPE) for sample preparation and screen-printed carbon electrodes (SPCEs) for square-wave anodic stripping voltammetry. This association involves the miniaturization of sample preparation and measurement process. Firstly, cadmium was extracted directly from urine samples employing a ZSM-5/Fe2O3, then, the composite enriched with cadmium was deposited onto the SPCE and finally covered with a suitable electrolyte for electrochemical detection. Thereby, the elution and detection of cadmium were carried out in a single step. To optimize experimental parameters affecting MDSPE, a two-step multivariate strategy has been employed. The method has been evaluated under optimized extraction/elution conditions (i.e., type of sorbent, ZSM-5/Fe2O3; amount of sorbent, 10 mg; sample pH, 6.8; extraction time, 5.5 min; and HCl concentration, 0.5 M) using standard addition calibration. Standard addition calibration curves gave a good linearity in the range from 0 to 30 μg L−1 with correlation coefficients ranging from 0.997 to 0.998 (N = 7). The limit of detection, evaluated empirically and statistically, ranged from 0.5 to 1.0 μg L−1 and from 0.4 to 0.8 μg L−1, respectively, which are lower than the threshold level established by the Ministry of Labour and Social Affairs (Spain) and World Health Organization for normal cadmium content in urine (i.e., 3.4 and 4.0 μg L−1, respectively). The repeatability of the proposed method was evaluated at 5 and 20 μg L−1 spiking levels obtaining coefficients of variation ranged between 12 and 15% (n = 6). A certified reference material (REC-8848/Level II) was analyzed to assess method accuracy finding 92% and 1.3 μg L−1 as the recovery (trueness) and standard deviation values, respectively. Finally, the method was applied to spiked urine samples, obtaining good agreement between spiked and found concentrations (recovery ranged from 89 to 98% and CV values ranged from 7% to 14%). Therefore, this is a new and successful contribution to the portable total analytical systems.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Zeolites and zeolite-based materials in extraction and microextraction techniques

  • Baile, Paola
  • Fernández Martínez, Elena
  • Vidal, Lorena
  • Canals, Antonio
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Vidal, Lorena|||/items/87ae49dd-73c8-41be-9c0c-2d3c37772793
Zeolites are ordered crystalline materials with a promising performance for a wide range of applications such as catalysis, petrochemistry, environmental remediation, and medicine, but have scarcely been evaluated in Analytical Chemistry. Their unique and fascinating properties such as their high surface area, high adsorption capacity and molecular selectivity, chemical and thermal stability, ion-exchange capacity, low cost extraction and synthesis, and their easy modification, which provides a wide range of zeolite-based materials, make zeolites potential sorbents for extraction procedures. Therefore, in this review, we provide an overview of the current status of zeolites and zeolite-based materials used in extraction and microextraction techniques with reference to recent applications and highlight some of the novel advances.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

A multinebulization technique for the determination of trace metals in a marine biota sample by on-line isotope dilution inductively coupled plasma mass spectrometry (OID-ICP-MS)

  • García, Miriam
  • Aguirre Pastor, Miguel Ángel
  • Vassileva, Emilia
  • Canals, Antonio
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
A new concept of a nebulizer (i.e., multinebulizer) has been employed for trace element (e.g., Cd, Cu, Hg, Ni, Pb, and Zn) determination in marine biota samples (e.g., fish sample). To this end, an analytical methodology based on the combination of a multinebulizer with an isotope dilution (ID) calibration strategy and inductively coupled plasma mass spectrometry (ICP-MS) has been proposed. In this way, the on-line isotope dilution (OID) is accomplished by the simultaneous introduction of the liquid samples/standard and the isotopic reference solution (i.e., spike) into the plasma with an efficient mixing between them, which takes place at the inner cavity of the multinebulizer tip. The proposed OID-ICP-MS analytical methodology allows the fast determination of Cd, Cu, Hg, Ni, Pb and Zn in a biota sample certified reference material (CRM) (e.g., IAEA-476) with limits of detection of 0.006, 0.4, 0.09, 30, 0.2 and 4 ng g−1, respectively, and recovery values ranging from 97 to 103%. The primary advantage offered by the proposed analytical methodology is that the time-consuming spiking step in the conventional ID analysis is avoided. This yields savings in both the total time and cost of the analysis per sample. Hence, it has been proved that OID-ICP-MS using a multinebulizer is a promising solution for the trace element analysis of samples with a high matrix content, which simplifies operation and significantly increases sample throughput and productivity.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Determination of As, Se, and Hg in fuel samples by in-chamber chemical vapor generation ICP OES using a Flow Blurring® multinebulizer

  • García, Miriam
  • Aguirre Pastor, Miguel Ángel
  • Canals, Antonio
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
In this work, a new and simple analytical methodology based on in-chamber chemical vapor generation has been developed for the spectrochemical analysis of commercial fuel samples. A multiple nebulizer with three nebulization units has been employed for this purpose: One unit was used for sample introduction, while the other two were used for the necessary reagent introduction. In this way, the aerosols were mixed inside the spray chamber. Through this method, analyte transport and, therefore, sensitivity are improved in inductively coupled plasma-optical emission spectrometry. The factors (i.e., variables), influencing chemical vapor generation, have been optimized using a multivariate approach. Under optimum chemical vapor generation conditions ([NaBH4] = 1.39%, [HCl] = 2.97 M, total liquid flow = 936 μL min−1), the proposed sample introduction system allowed the determination of arsenic, selenium, and mercury up to 5 μg g−1 with a limit of detection of 25, 140, and 13 μg kg−1, respectively. Analyzing spiked commercial fuel samples, recovery values obtained were between 96 and 113%, and expanded uncertainty values ranged from 4 to 16%. The most striking practical conclusion of this investigation is that no carbon deposit appears on the plasma torch after extended periods of working.