Pasar al contenido principal

NUEVAS METODOLOGIAS ANALITICAS ECOLOGICAS: AVANCES EN LA MICROEXTRACCION LIQUIDO-LIQUIDO Y EN SUS SISTEMAS DE DETECCION

CTQ2011-23968

•
Nombre agencia financiadora Ministerio de Ciencia e Innovación
Acrónimo agencia financiadora MICINN
Programa Programa Nacional de Proyectos de Investigación Fundamental
Subprograma Subprograma de Proyectos de Investigación Fundamental no Orientada
Convocatoria Proyectos I+D
Año convocatoria 2011
Plan Estatal 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Unidad de gestión Subdirección General de Proyectos de Investigación
Centro beneficiario UNIVERSIDAD DE ALICANTE
Identificador persistente http://dx.doi.org/10.13039/501100004837

Resultados relacionados

Resultados totales (Incluyendo duplicados): 10
Encontrada(s) 1 página(s)

RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Screen-printed electrode-based electrochemical detector coupled with in-situ ionic-liquid-assisted dispersive liquid–liquid microextraction for determination of 2,4,6-trinitrotoluene

  • Fernández Martínez, Elena
  • Vidal, Lorena
  • Iniesta, Jesus
  • Metters, Jonathan P.
  • Banks, Craig E.
  • Canals, Antonio
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Iniesta, Jesus|||/items/9131f62f-f4a8-44bf-83be-90c9270e5d9d
  • Vidal, Lorena|||/items/87ae49dd-73c8-41be-9c0c-2d3c37772793
A novel method is reported, whereby screen-printed electrodes (SPELs) are combined with dispersive liquid–liquid microextraction. In-situ ionic liquid (IL) formation was used as an extractant phase in the microextraction technique and proved to be a simple, fast and inexpensive analytical method. This approach uses miniaturized systems both in sample preparation and in the detection stage, helping to develop environmentally friendly analytical methods and portable devices to enable rapid and onsite measurement. The microextraction method is based on a simple metathesis reaction, in which a water-immiscible IL (1-hexyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide, [Hmim][NTf2]) is formed from a water-miscible IL (1-hexyl-3-methylimidazolium chloride, [Hmim][Cl]) and an ion-exchange reagent (lithium bis[(trifluoromethyl)sulfonyl]imide, LiNTf2) in sample solutions. The explosive 2,4,6-trinitrotoluene (TNT) was used as a model analyte to develop the method. The electrochemical behavior of TNT in [Hmim][NTf2] has been studied in SPELs. The extraction method was first optimized by use of a two-step multivariate optimization strategy, using Plackett–Burman and central composite designs. The method was then evaluated under optimum conditions and a good level of linearity was obtained, with a correlation coefficient of 0.9990. Limits of detection and quantification were 7 μg L−1 and 9 μg L−1, respectively. The repeatability of the proposed method was evaluated at two different spiking levels (20 and 50 μg L−1), and coefficients of variation of 7 % and 5 % (n = 5) were obtained. Tap water and industrial wastewater were selected as real-world water samples to assess the applicability of the method.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Analysis of metals and phosphorus in biodiesel B100 from different feedstock using a Flow Blurring® multinebulizer in inductively coupled plasma-optical emission spectrometry

  • Ávila Orozco, Francisco D.
  • Kovachev, Nikolay
  • Aguirre Pastor, Miguel Ángel
  • Domini, Claudia E.
  • Fernández Band, Beatriz S.
  • Canals, Antonio
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
A simple and fast method for determining the content of Na, K, Ca, Mg, P, and 20 heavy metals in biodiesel samples with inductively coupled plasma optical emission spectrometry (ICP OES) using a two-nozzle Flow Blurring® multinebulizer prototype and on-line internal standard calibration, are proposed. The biodiesel samples were produced from different feedstock such as sunflower, corn, soybean and grape seed oils, via a base catalyst transesterification. The analysis was carried out without any sample pretreatment. The standards and samples were introduced through one of the multinebulizer nozzles, while the aqueous solution containing yttrium as an internal standard was introduced through the second nozzle. Thus, the spectral interferences were compensated and the formation of carbon deposits on the ICP torch was prevented. The determination coefficients (R2) were greater than 0.99 for the studied analytes, in the range 0.21–14.75 mg kg−1. Short-term and long-term precisions were estimated as relative standard deviation. These were acceptable, their values being lower than 10%. The LOQ for major components such as Ca, K, Mg, Na, and P, were within a range between 4.9 ng g−1 for Mg (279.553 nm) and 531.1 ng g−1 for Na (588.995 nm), and for the other 20 minor components they were within a range between 1.1 ng g−1 for Ba (455.403 nm) and 2913.9 ng g−1 for Pb (220.353 nm). Recovery values ranged between 95% and 106%.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Graphene oxide/Fe3O4 as sorbent for magnetic solid-phase extraction coupled with liquid chromatography to determine 2,4,6-trinitrotoluene in water samples

  • Costa dos Reis, Luciana
  • Vidal, Lorena
  • Canals, Antonio
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Vidal, Lorena|||/items/87ae49dd-73c8-41be-9c0c-2d3c37772793
A fast, simple, economical, and environmentally friendly magnetic solid-phase extraction (MSPE) procedure has been developed to preconcentrate 2,4,6-trinitrotoluene (TNT) from water samples prior to determination by liquid chromatography-UV-Vis employing graphene oxide/Fe3O4 nanocomposite as sorbent. The nanocomposite synthesis was investigated, and the MSPE was optimized by a multivariate approach. The optimum MSPE conditions were 40 mg of nanocomposite, 10 min of vortex extraction, 1 mL of acetonitrile as eluent, and 6 min of desorption in an ultrasonic bath. Under the optimized experimental conditions, the method was evaluated to obtain a preconcentration factor of 153. The linearity of the method was studied from 1 to 100 μg L−1 (N = 5), obtaining a correlation coefficient of 0.994. The relative standard deviation and limit of detection were found to be 12% (n = 6, 10 μg L−1) and 0.3 μg L−1, respectively. The applicability of the method was investigated, analyzing three types of water samples (i.e., reservoir and drinking water and effluent wastewater) and recovery values ranged between 87 and 120% (50 μg L−1 spiking level), showing that the matrix had a negligible effect upon extraction. Finally, the semiquantitative Eco-Scale metrics confirmed the greenness of the developed method.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Dispersive liquid–liquid microextraction combined with laser-induced breakdown spectrometry and inductively coupled plasma optical emission spectrometry to elemental analysis

  • Gaubeur, Ivanise
  • Aguirre Pastor, Miguel Ángel
  • Kovachev, Nikolay
  • Hidalgo, Montserrat
  • Canals, Antonio
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Hidalgo, Montserrat|||/items/8c122b2d-4d92-45f3-ad75-e863e4e18750
In this paper, two analytical methodologies based on the combination of dispersive liquid–liquid microextraction with inductively coupled plasma optical emission spectrometry and laser-induced breakdown spectrometry, respectively, were evaluated for simultaneous preconcentration and detection of Cd, Co, Ni, Pb and Zn. The microextraction procedure was based on the injection of appropriate quantities of 1-undecanol and methanol into the sample solution containing the complexes formed between metal ions and 1-(2-pyridylazo) 2-naphtol (PAN). The main experimental factors affecting the complexation and the extraction of metals (pH, PAN concentration, salt addition and extractant solvent and disperser solvent volume) were optimized using a multivariate analysis consisting of two steps: a Plackett-Burman design followed by a Circumscribed Central Composite Design (CCCD). Under optimum microextraction conditions, the analytical features of the proposed methodologies were assessed. Accuracy was evaluated by analyzing two certified reference materials, yielding results in agreement with the certified values. Both methodologies were applied to the analysis of a number of beverage samples.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Determination of cyclic and linear siloxanes in wastewater samples by ultrasound-assisted dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry

  • Cortada Cortés, Carolina
  • Costa dos Reis, Luciana
  • Vidal, Lorena
  • Llorca, Julio
  • Canals, Antonio
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Vidal, Lorena|||/items/87ae49dd-73c8-41be-9c0c-2d3c37772793
A fast, simple and environmentally friendly ultrasound-assisted dispersive liquid-liquid microextraction (USA-DLLME) procedure has been developed to preconcentrate eight cyclic and linear siloxanes from wastewater samples prior to quantification by gas chromatography-mass spectrometry (GC-MS). A two-stage multivariate optimization approach has been developed employing a Plackett-Burman design for screening and selecting the significant factors involved in the USA-DLLME procedure, which was later optimized by means of a circumscribed central composite design. The optimum conditions were: extractant solvent volume, 13 µL; solvent type, chlorobenzene; sample volume, 13 mL; centrifugation speed, 2300 rpm; centrifugation time, 5 min; and sonication time, 2 min. Under the optimized experimental conditions the method gave levels of repeatability with coefficients of variation between 10 and 24% (n=7). Limits of detection were between 0.002 and 1.4 µg L−1. Calculated calibration curves gave high levels of linearity with correlation coefficient values between 0.991 and 0.9997. Finally, the proposed method was applied for the analysis of wastewater samples. Relative recovery values ranged between 71–116% showing that the matrix had a negligible effect upon extraction. To our knowledge, this is the first time that combines LLME and GC-MS for the analysis of methylsiloxanes in wastewater samples.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Speciation of chromium by dispersive liquid–liquid microextraction followed by laser-induced breakdown spectrometry detection (DLLME–LIBS)

  • Gaubeur, Ivanise
  • Aguirre Pastor, Miguel Ángel
  • Kovachev, Nikolay
  • Hidalgo, Montserrat
  • Canals, Antonio
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Hidalgo, Montserrat|||/items/8c122b2d-4d92-45f3-ad75-e863e4e18750
In this study, an analytical methodology based on a combination of dispersive liquid–liquid microextraction with laser-induced breakdown spectrometry was evaluated for simultaneous pre-concentration, speciation and detection of Cr. The microextraction procedure was based on the injection of appropriated quantities of 1-undecanol and ethanol into a sample solution containing the complexes formed between Cr(VI) and diethyldithiocarbamate (DDTC). The main experimental factors affecting the complexation and the extraction of metal (pH, DDTC concentration, extractant and volume of disperser solvents) were optimized using a multivariate analysis consisting of two steps: a Plackett–Burman design followed by a Circumscribed Central Composite Design (CCCD). Under optimum microextraction conditions, the analytical figures of merit of the proposed methodology were assessed. The method was finally applied to the analysis of a certified reference material hard drinking water (ERM® CA011a), yielding results in good agreement with the certified value.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Total sulfur determination in liquid fuels by ICP-OES after oxidation-extraction desulfurization using magnetic graphene oxide

  • Ahmadi, Mazaher
  • Aguirre Pastor, Miguel Ángel
  • Madrakian, Tayyebeh
  • Afkhami, Abbas
  • Canals, Antonio
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
This paper presents a graphene oxide-based magnetic nanocomposite as a catalyst for desulfurization and also as a sorbent for removal of the total sulfur in liquid fuel matrices. The magnetic nanocomposite was prepared by decorating graphene oxide nanosheets with magnetite nanoparticles (MGO). For the desulfurization experiments, an oxidation-extraction procedure was developed using MGO as the catalyst and H2O2 as the oxidant. For the sulfur determination experiments, the oxidized-sulfur compounds were sorbed by magnetic solid phase extraction (MSPE) followed by ICP-OES detection. The magnetic nanocomposite showed high efficiency as did both the catalyst of sulfur compounds oxidation and the adsorbent of the oxidized sulfur compounds. Different parameters which could affect the desulfurization and determination were optimized using a multivariate analysis. The results showed that under the optimum conditions removal efficiencies of over 97% were achievable and the limit of detection of 0.15 mg kg−1 of sulfur was obtained. Finally, the spiked/recovery assays of commercial fuel samples using MSPE-ICP-OES led to recovery values in the range of 94 ± 5% to 101 ± 3%. The results obtained suggest that a powerful alternative has been developed for the desulfurization and total sulfur determination in commercial fuel samples.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Dispersive liquid–liquid microextraction for metals enrichment: A useful strategy for improving sensitivity of laser-induced breakdown spectroscopy in liquid samples analysis

  • Aguirre Pastor, Miguel Ángel
  • Selva, E.J.
  • Hidalgo, Montserrat
  • Canals, Antonio
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Hidalgo, Montserrat|||/items/8c122b2d-4d92-45f3-ad75-e863e4e18750
A rapid and efficient Dispersive Liquid–Liquid Microextraction (DLLME) followed by Laser-Induced Breakdown Spectroscopy detection (LIBS) was evaluated for simultaneous determination of Cr, Cu, Mn, Ni and Zn in water samples. Metals in the samples were extracted with tetrachloromethane as pyrrolidinedithiocarbamate (APDC) complexes, using vortex agitation to achieve dispersion of the extractant solvent. Several DLLME experimental factors affecting extraction efficiency were optimized with a multivariate approach. Under optimum DLLME conditions, DLLME-LIBS method was found to be of about 4.0–5.5 times more sensitive than LIBS, achieving limits of detection of about 3.7–5.6 times lower. To assess accuracy of the proposed DLLME-LIBS procedure, a certified reference material of estuarine water was analyzed.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Determination of As, Se, and Hg in fuel samples by in-chamber chemical vapor generation ICP OES using a Flow Blurring® multinebulizer

  • García, Miriam
  • Aguirre Pastor, Miguel Ángel
  • Canals, Antonio
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
In this work, a new and simple analytical methodology based on in-chamber chemical vapor generation has been developed for the spectrochemical analysis of commercial fuel samples. A multiple nebulizer with three nebulization units has been employed for this purpose: One unit was used for sample introduction, while the other two were used for the necessary reagent introduction. In this way, the aerosols were mixed inside the spray chamber. Through this method, analyte transport and, therefore, sensitivity are improved in inductively coupled plasma-optical emission spectrometry. The factors (i.e., variables), influencing chemical vapor generation, have been optimized using a multivariate approach. Under optimum chemical vapor generation conditions ([NaBH4] = 1.39%, [HCl] = 2.97 M, total liquid flow = 936 μL min−1), the proposed sample introduction system allowed the determination of arsenic, selenium, and mercury up to 5 μg g−1 with a limit of detection of 25, 140, and 13 μg kg−1, respectively. Analyzing spiked commercial fuel samples, recovery values obtained were between 96 and 113%, and expanded uncertainty values ranged from 4 to 16%. The most striking practical conclusion of this investigation is that no carbon deposit appears on the plasma torch after extended periods of working.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Hyphenation of single-drop microextraction with laser-induced breakdown spectrometry for trace analysis in liquid samples: a viability study

  • Aguirre Pastor, Miguel Ángel
  • Nikolova, H.
  • Hidalgo, Montserrat
  • Canals, Antonio
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
  • Hidalgo, Montserrat|||/items/8c122b2d-4d92-45f3-ad75-e863e4e18750
In this work, an analytical methodology based on single drop microextraction (SDME) followed by Laser-Induced Breakdown Spectrometry (LIBS) has been tested for trace metal determination in liquid samples. By this method, analytes in the samples were extracted into a small volume of toluene as ammonium pyrrolidinedithiocarbamate (APDC) chelates. After that, the analyte-enriched toluene was dried on a solid substrate and, finally, the resulting solid residue was analyzed by LIBS. Analyte extraction by the SDME procedure was optimized for the first time by using a multivariate optimization approach. Under optimum SDME conditions, analytical figures of merit of the proposed SDME-LIBS methodology were compared to those of the direct LIBS analysis method (i.e., without the SDME procedure). An estuarine water certified reference material was analyzed for method trueness evaluation. The results obtained in this study indicate that SDME-LIBS methodology leads to a sensitivity increase of about 2.0–2.6 times the ones obtained by LIBS. Detection limits of SDME-LIBS decrease according to the obtained sensitivity improvement, reaching values in the range 21–301 μg kg−1 for the analytes tested. The measurement repeatability was similar in both SDME-LIBS (13–20% RSD) and LIBS (16–20% RSD) methodologies, mainly limited by the LIBS experimental setup used in this work for LIBS analysis of liquid samples. The SDME-LIBS analysis of the certified reference material led to recovery values in the range of 96% to 112%.