Pasar al contenido principal

ESTUDIO EXPERIMENTAL Y NUMERICO DE REGIONES D TRIDIMENSIONALES DE HORMIGON ARMADO: ENCEPADOS Y CALICES

BES-2013-063409

•
Nombre agencia financiadora Ministerio de Ciencia e Innovación
Acrónimo agencia financiadora MICINN
Programa Programa Estatal de Promoción del Talento y su Empleabilidad en I+D+i
Subprograma Subprograma Estatal de Formación
Convocatoria Contratos Predoctorales
Año convocatoria 2013
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Unidad de gestión Secretaría de Estado de Educación, Formación Profesional y Universidades
Centro beneficiario UNIVERSITAT POLITÈCNICA DE VALÈNCIA
Identificador persistente http://dx.doi.org/10.13039/501100004837

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Tesis doctoral (DoctoralThesis)

Estudio de encepados de tres y cuatro pilotes solicitados por cargas centradas y excéntricas: análisis experimental y de las formulaciones de diseño

  • Miguel Tórtola, Lucía
[ES] Los encepados sobre pilotes son empleados en las cimentaciones profundas de edificios y puentes para transmitir las solicitaciones del pilar a los pilotes embe-bidos en el terreno. En el caso más habitual de los encepados rígidos, se gene-ran campos tensionales complejos, por lo que se consideran regiones D en su totalidad. Las solicitaciones que transmite el pilar a la cimentación incluyen generalmente combinaciones de esfuerzos axil, flector y cortante. A pesar de tratarse del esta-do de carga más común, no existen hasta la fecha ensayos de encepados de más de dos pilotes con carga vertical no centrada. Existe además cierta falta de consenso sobre la disposición de armado en ence-pados: la proporción entre el armado concentrado en bandas frente al distribui-do en la base, y la necesidad de disponer un armado vertical en cercos atando las bandas. Tampoco existen ensayos experimentales diseñados para estudiar la eficacia de la armadura secundaria vertical. Con objeto de estudiar la influencia del tipo de carga, la configuración de ar-mado, el número de pilotes y la esbeltez, se lleva a cabo una campaña experi-mental de 30 ensayos de encepados de tres y cuatro pilotes a escala real. Los ensayos se realizan bajo carga centrada y excéntrica, sobre especímenes con dis-tintas relaciones vuelo-canto (w/d = [0.56-1.68]). Se comparan además tres con-figuraciones de armado: armado en bandas, armado en banda y distribuido ho-rizontal y armado en bandas, distribuido horizontal y con armadura vertical. Se presenta un modelo de bielas y tirantes tridimensional, válido para cargas excéntricas, que explica la contribución resistente de las armaduras secundarias horizontales y verticales. El modelo forma parte de una propuesta unificada, que relaciona el ángulo de inclinación de las bielas con la comprobación de la capacidad resistente del hormigón en bielas y zonas nodales. Por otra parte, se realiza un estudio del tratamiento normativo (Eurocódigo 2, ACI 318-14) del punzonamiento y cortante en encepados, para evaluar su capa-cidad para predecir la resistencia y modo de fallo en condiciones de carga tanto centrada como excéntrica y con diferentes configuraciones de armado. Este estudio culmina con la aplicación a encepados de la Teoría de la Fisura Crítica, en la que se basa la formulación de punzonamiento del Código Modelo 2010, que ya ha sido extendida con éxito al caso de zapatas., [CA] Els encepats sobre pilós són emprats en els fonaments profunds d'edificis i ponts per a transmetre les sol·licitacions del pilar als pilós embeguts en el ter-reny. En el cas més habitual dels encepats rígids, es generen camps tensionals complexos, per la qual cosa es consideren regions D íntegrament. Les sol·licitacions que transmet un pilar als fonaments a través de l'encepat inclouen generalment combinacions d'esforços axial, flector i tallant. Malgrat tractar-se de l'estat de càrrega més comuna, no existeixen fins hui assajos de encepats de més de dos pilotes amb càrrega vertical no centrada. Existeix a més certa falta de consens sobre la disposició d'armat en encepats: la proporció entre l'armat concentrat en bandes enfront del distribuït en la base, i la necessitat de disposar un armat vertical (estreps) lligant les bandes. Tampoc existeixen assajos experimentals dissenyats per a estudiar l'eficàcia de l'armadura secundària vertical. A fi d'estudiar la influència del tipus de càrrega, la configuració d'armat, el nú-mero de pilotes i l'esveltesa, es duu a terme una campanya experimental de 30 assajos de encepats de tres i quatre pilotes a escala real. Els assajos es realitzen sota càrrega centrada i excèntrica, sobre espècimens amb diferents relacions d'esveltesa (w/d = [0.56-1.68]). Es comparen a més tres configuracions d'armat: armat en bandes, armat en banda i distribuït horitzontal i armat en bandes, dis-tribuït horitzontal i amb armadura vertical. Es presenta un model de bieles i tirants tridimensional, vàlid per a càrregues excèntriques, que explica la contribució resistent de les armadures secundàries horitzontals i verticals. El model forma part d'una proposta unificada, que rela-ciona l'angle d'inclinació de les bieles amb la comprovació de la capacitat resis-tent del formigó en bieles i zones nodals. D'altra banda, es realitza un estudi del tractament normatiu (Eurocódigo 2, ACI 318-14) del punxonament i tallant en encepats, per a avaluar la seua capaci-tat per a predir la resistència i manera de fallada en condicions de càrrega tant centrada com excèntrica i amb diferents configuracions d'armat. Aquest estudi culmina amb l'aplicació a encepats de la Teoria de la Fissura Crítica, en la qual es basa la formulació de punxonament del Codi Model 2010, que ja ha sigut estesa amb èxit al cas de sabates., [EN] Pile caps are used as deep foundations of buildings and bridges to transfer col-umn loads to the piles into the ground. Deep pile caps are commonly used in practice. These elements are usually considered as an entire D-region because complex stress fields develop inside them. Although these loads usually consist of a combination of an axial force and bending moments in one or two directions, all the experimental studies carried out to date that analysed pile cap behaviour have only considered centred loads. There is a lack of agreement regarding the proper reinforcement arrangement in pile caps: the proportion between bunched and distributed reinforcement at the pile cap base, and the convenience of a vertical secondary reinforcement in stir-rups. There are also no experimental tests on pile caps designed to study the effectiveness of vertical secondary reinforcement. With the aim of assessing the influence of non-centred loads, the reinforcement arrangement, the number of piles and the slenderness, an experimental cam-paign on 30 real scale pile caps has been conducted. The tests are carried out under centred and eccentric loads. The shear-span ratio ranges from 0.56 to 1.10 for the four-pile caps and from 0.84 to 1.68 for the three-pile caps. Moreover, three reinforcement layouts are compared: bunched reinforcement, bunched in addition with distributed reinforcement and finally, bunched in addition with distributed and vertical secondary reinforcement in stirrups. Two different approaches for the analysis of these results are considered. On the one hand, a unified STM formulation is presented, valid for eccentric loads, which considers the contribution of the horizontal and vertical secondary rein-forcement to the pile cap strength. This model links the strut inclination with the stress verification in struts and nodal zones. On the other hand, punching and shear formulations of Eurocode 2 and ACI 318-14 are studied to assess their ability to predict the strength and failure mode of pile caps, in both centred and eccentric load conditions and with dif-ferent reinforcement configurations. This study ends with the application of the Critical Shear Crack Theory to pile caps. The Model Code 2010 punching for-mulation is based on the CSCT and has already been successfully applied to squat footings., Agradecer la financiación pública recibida a través del Ministerio de Economía y Competitividad, mediante las Ayudas para contratos predoctorales para la formación de doctores (BES-2013-063409), que me ha permitido una dedicación completa durante cuatro años a esta investigación. Tanto dicha ayuda como la financiación de los ensayos experimentales realizados forman parte del proyecto Estudio experimental y numérico de regiones D tridimensionales de hormigón armado: encepados y cálices (BIA2012-323000). Deseo resaltar la maravillosa experiencia que tuve durante mi estancia de investigación en la University of Surrey. Esta estancia de tres meses fue subvencionada por las Ayudas a la movilidad predoctoral del Ministerio de Economía y Competitividad (EEBB-I-17-12364).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Punching shear failure in three-pile caps: Influence of the shear span-depth ratio and secondary reinforcement

  • Miguel-Tortola, Lucia
  • Pallarés Rubio, Luis|||0000-0003-2126-2387
  • Miguel Sosa, Pedro|||0000-0001-5395-8149
[EN] The strut-and-tie model (STM) is currently established as the best approach for pile cap design. This model leads to efficient estimations of the main reinforcement placed in strips between piles. However, good practices and some international Concrete Design Standards recommend some secondary distributed reinforcement, and even vertical stirrups that are not considered by the STM. An experimental campaign with nine three-pile caps tested by a centered load is presented to show the influence of both secondary reinforcement and the shear span-depth ratio on pile cap strength. The experimental results show a potential redistribution of internal forces in pile caps after yielding of main reinforcement, finally collapsed due to punching. Secondary reinforcement proves efficient to enhance pile cap strength since it takes part in complementary resistance mechanisms. As expected, the failure load increases with shear span-depth ratio reduction. The STM neither captures the effect of this ratio nor considers punching failure. Checking this failure mode is also required for pile caps. The punching formulation of Eurocode 2 allows considering the influence of this ratio, but some interpretation is required whether one deals with pile caps, regarding the effective width of the shear enhancement factor and the definition of the basic control perimeter. A proper definition would prevent unsafe or very conservative results. Therefore, some recommendations for the verification of deep pile caps following the Eurocode 2 are presented. The contribution of vertical stirrups as punching reinforcement is also investigated. The proposed approach is applied to the existing experimental database of three- and four-pile caps to check formulation validity, and conservative predictions with low coefficient of variation are reached., The authors would like to acknowledge the funding received from the Spanish Ministry of Economy and Competitiveness for basic non oriented research projects (BIA2012-32300), which also included a PhD fellowship (BES-2013-063409).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Strength of pile caps under eccentric loads: Experimental study and review of code provisions

  • Miguel-Tortola, Lucia
  • Miguel Sosa, Pedro|||0000-0001-5395-8149
  • Pallarés Rubio, Luis|||0000-0003-2126-2387
[EN] Pile caps are rigid reinforced concrete structures that transfer column loads, generally consisting of a combination of an axial load and bending moments in one or two directions, to the piles. The design formulations of pile caps for more than two piles were derived from the results of experimental tests under a centered load. The practice of checking both punching and shear failure modes is common as described in the literature review, even though these formulations were developed for more slender elements. Currently, Codes ACI 318-14 and EC2 allow designing pile caps with strut-and-tie models or sectional approaches (shear, punching and flexural designs). In this study, 21 full-scale pile caps with different shear span-depth ratios and reinforcement layouts were studied to investigate the effect of eccentric loading on the strength and accuracy of the code formulations. The results show that in eccentrically loaded pile caps, the ultimate load is reduced but the maximum pile reaction increases and the secondary reinforcement proves effective to enhance the pile cap strength. Although the strut-and-tie models (STM) allow eccentric loads to be taken into consideration, they predict a much lower peak load than that observed at the experimental results and do not adequately reflect either the influence of slenderness or the failure mode. In general the sectional approach provided by Codes ACI-318-14, EC2 and MC-2010 (Level I of Approximation) lead to safe predictions of the peak load but do not always correctly predict the failure mode. The ultimate load predicted by EC-2 formulation comes closest to the experimental peak load, accurately reflects the influence of slenderness and the effect of secondary reinforcement, however, additional assumptions need to be made for its application. The ACI formulation complemented by the CRSI-2008 Special Investigation for deep pile caps is the safest but does not adequately capture the effect of horizontal and vertical secondary reinforcement. The MC2010 LoAI formulation is also conservative but does not detect the influence of slenderness or the contribution of secondary reinforcement., The authors wish to express their gratitude for the financial support (BIA2012-32300 and BIA2015-64672-C4-4-R) received from the Spanish Ministry of Economy and Competitiveness, which enabled the experimental campaign to be carried out, also for the PhD fellowship (BES-2013-063409).