Publicación Artículo científico (JournalArticle)

Rapid and portable molecular test for Mycobacterium sp. based on double-tagging amplification and electrochemical readout

  • Mesas Gómez, Melania|||0000-0002-3297-1077
  • Ropero Gil, Daniel|||0009-0008-2522-1340
  • Molina-Moya, Barbara|||0000-0001-5144-2165
  • Pallarès-Rusiñol, Arnau|||0000-0001-9990-148X
  • Ferrer-Dalmau, Jofre|||0000-0002-7415-6222
  • Julián, Esther|||0000-0002-6558-3978
  • Domínguez, José|||0000-0001-7888-0309
  • Pividori, María Isabel|||0000-0002-5266-7873
Tuberculosis (TB) remains one of the leading causes of death worldwide, with Mycobacterium tuberculosis as the main pathogen responsible. Although several rapid molecular tests endorsed by the World Health Organization (WHO) show high accuracy, their implementation in low-resource settings is still limited by cost and infrastructure requirements. In this work, a rapid and portable molecular test was developed for Mycobacterium sp. detection based on double-tagging polymerase chain reaction (PCR) and electrochemical magneto-genosensing. The method enables amplification of mycobacterial DNA using primers targeting the gyrB and IS6110 genes through a double-tagging PCR completed within approximately one hour, followed by electrochemical detection on a handheld, battery-operated device, yielding a measurable current signal within 15 minutes, including single-step incubation and electrochemical readout. The test achieved a limit of detection as low as 117 CFU mL−1 for the gyrB target, comparable to the commercial GeneXpert® MTB/RIF assay, while significantly reducing assay time and equipment needs. Total analysis, including DNA extraction, amplification and detection, was completed within approximately two hours. In addition, comparable electrochemical responses were obtained when PCR amplification was carried out using either a conventional benchtop thermocycler or a portable battery-operated miniPCR device, further supporting the applicability of the method in decentralized and field settings. Overall, this approach combines high sensitivity, portability, and simplicity, offering a promising solution for point-of-care TB diagnosis and adaptable to other infectious diseases by changing the primer sequences.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Improved biosensing of Legionella by integrating filtration and immunomagnetic separation of the bacteria retained in filters

  • Mesas Gómez, Melania|||0000-0002-3297-1077
  • Molina-Moya, Barbara|||0000-0001-5144-2165
  • de Araújo, Bárbara Camila
  • Boldrin Zanoni, Maria Valnice|||0000-0002-2296-1393
  • Julián, Esther|||0000-0002-6558-3978
  • Domínguez, José|||0000-0001-7888-0309
  • Pividori, María Isabel|||0000-0002-5266-7873
A novel approach is presented that combines filtration and the direct immunomagnetic separation of the retained bacteria Legionella in filters, for further electrochemical immunosensing. This strategy allows for the separation and preconcentration of the water-borne pathogen from high-volume samples, up to 1000 mL. The limit of detection of the electrochemical immunosensor resulted in 100 CFU mL-1 and improved up to 0.1 CFU mL-1 when the preconcentration strategy was applied in 1 L of sample (103-fold improvement). Remarkably, the immunosensor achieves the limit of detection in less than 2.5 h and simplified the analytical procedure. This represents the lowest concentration reported to date for electrochemical immunosensing of Legionella cells without the need for pre-enrichment or DNA amplification. Furthermore, the study successfully demonstrates the extraction of bacteria retained on different filtering materials using immunomagnetic separation, highlighting the high efficiency of the magnetic particles to pull out the bacteria directly from solid materials. This promising feature expands the applicability of the method beyond water systems for detecting bacteria retained in air filters of air conditioning units by directly performing the immunomagnetic separation in the filters.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Mycobacterium detection method combining filtration, immunomagnetic separation, and electrochemical readout in a portable biosensing device

  • Mesas Gómez, Melania|||0000-0002-3297-1077
  • Molina-Moya, Barbara|||0000-0001-5144-2165
  • de Araújo, Bárbara Camila
  • Pallarès-Rusiñol, Arnau|||0000-0001-9990-148X
  • Ferrer-Dalmau, Jofre|||0000-0002-7415-6222
  • Boldrin Zanoni, Maria Valnice|||0000-0002-2296-1393
  • Domínguez, José|||0000-0001-7888-0309
  • Julián, Esther|||0000-0002-6558-3978
  • Pividori, María Isabel|||0000-0002-5266-7873
This study addresses a straightforward and highly sensitive approach for detecting Mycobacterium fortuitum. The method involves a combination of filtration and direct immunomagnetic separation to isolate the bacteria retained on filters for further electrochemical magneto immunosensing in a handheld device. Unlike conventional methods involving pre-enrichment by culturing, this approach employs a simplified preconcentration technique, which includes filtration of large water samples, up to 100 mL, followed by a one-step process of immunomagnetic separation and labeling. After a 60-min, during which the filter with the retained bacteria and all the reagents (including modified magnetic particles and enzymatic conjugates) are incubated, the resulting product is directly drop into a cartridge, capable of performing magnetic actuation and washing. The electrochemical readout is carried out on a portable battery-operated device within 30 seconds. Remarkably, the immunosensor demonstrates an outstanding limit of detection of 5 CFU mL-1 in hemodialysis water processing 100 mL of sample. This achievement is remarkable considering the short and simplified analytical procedure, compared to the traditional isolation and culturing of mycobacteria, which typically takes 2 weeks.