Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

An LTCC monolithic microreactor for the synthesis of carbon dots with photoluminescence imaging of the reaction progress

  • Berenguel-Alonso, Miguel|||0000-0002-3759-3634
  • Ortiz-Gómez, Inmaculada|||0000-0003-4677-2383
  • Fernández, Belén|||0000-0001-9987-1495
  • Couceiro, Pedro|||0000-0001-5539-2441
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
  • Capitan-Vallvey, Luis Fermín|||0000-0002-7112-3601
  • Salinas-Castillo, Alfonso|||0000-0002-1360-6699
  • Puyol, Mar|||0000-0002-9274-2284
This work describes the development of a fully integrated Low Temperature Co-fired Ceramic (LTCC)microreactor for the synthesis of carbon dots (CDots). The microreactor integrates fluidics, a heating resistor and an optical window for fluorescence imaging of the reaction progress in a monolithic, all ceramic device, ensuring homogeneous surface chemistry and physical properties. A pool of different CDots was synthesized at high temperature and pressure using a hydrothermal method, demonstrating the robustness of the microreactor. The synthesis was monitored by following the photoluminescence of the produced CDots, and the reaction conditions were optimized according to their Quantum Yield (QY)and the flow pattern inside the microchannel. The obtained CDots exhibited blue photoluminescence upon irradiation with UV light with QYs of up to 0.77. The CDots were screened as metal nanoprobes and bioimaging contrast agents.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Molecularly Imprinted Polymers as Biomimetic Test Zones in Paper-Based Nucleic Acid Assays-Comparing Vertical and Lateral Flow Formats

  • Marfà, Jennifer|||0000-0001-5321-3841
  • Valle, Anaixis del|||0000-0001-5587-9081
  • Taboada Sotomayor, Maria Del Pilar|||0000-0002-6173-7888
  • Pividori, María Isabel|||0000-0002-5266-7873
The development of rapid and sensitive point-of-care nucleic acid tests benefits from robust synthetic recognition elements. Here, a biotin-specific molecularly imprinted polymer (MIP) was synthesized using an optimized protocol and integrated as a biomimetic test zone into two paper-based formats: nucleic acid vertical flow (NAVF) and nucleic acid lateral flow (NALF). Both platforms were evaluated for the detection of double-tagged PCR amplicons from Escherichia coli. NAVF enabled a 3 min visual readout with an LOD of 1.00 × 10-2 ng mL-1. NALF provided a total assay time of <15 min and achieved a visual LOD of 3.17 × 10-2 ng mL-1. Overall, the results demonstrate the versatility of biotin-MIPs as stable synthetic receptors for rapid, low-cost paper-based nucleic acid assays, with NAVF prioritizing speed and design flexibility and NALF prioritizing higher analytical sensitivity.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Microanalyser prototype for on-line monitoring of copper(II) ion in mining industrial processes

  • Guevara Amatón, Karla Victoria
  • Tavares, Nuno
  • Coto-Fuentes, Hesner|||0000-0002-9548-7864
  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Sández, Natàlia|||0000-0003-1712-3552
  • Moreno Casillas, Héctor Aurelio|||0000-0003-0740-6209
  • Valdés-Perezgasga, Francisco|||0000-0002-7176-3641
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
A microanalyzer prototype for copper(II) ion monitoring in mining industrial processes is presented. The microanalyzer is designed as an assembly of di_erent modules, each module being responsible for a unit operation. In order to optimize the industrial processes, the microanalyzer can automate all sample management, signal processing, and mathematical calculations and wirelessly transfer data to a control room. The determination of copper(II) ion is done using a colorimetric reaction and the microanalyser performs autocalibration by in situ dilution of a stock solution, matching the higher analyte concentration of the working range defined for the sample to be determined, using a multicommutation approach. The performance of the microanalyzer for monitoring copper(II) ion in water effuents of mining facilities was optimized in the working range from 1 to 10 mg/L to match Mexican environmental law regulations, which allow a maximum concentration of 4 mg/L of copper(II) ion in these circumstances.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Biomedical point-of-care microanalyzer for potentiometric determination of ammonium ion in plasma and whole blood

  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Rebollo Calderón, Beatriz|||0000-0001-5968-8004
  • Ormazábal, Aida
  • Artuch, R.|||0000-0002-3422-9685
  • Rosell Ferrer, Javier|||0000-0002-9691-328X
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
  • Puyol, Mar|||0000-0002-9274-2284
Some inborn errors of metabolism and other diseases can result in increasing blood ammonium (hyperammonemia episodes), which can cause serious neurological complications in patients or even death. Early diagnosis, follow up and treatment are essential to minimize irreversible damages in brain. Currently, adequate analytical instrumentation for the necessary ammonium bedside determination is not available in all health centers but only in clinical laboratories of reference hospitals. We therefore have developed a low cost and portable potentiometric Point-of-Care microanalyzer (POC) to address this problem. It consists of a cyclic olefin copolymer-based microanalyzer, the size of a credit card and working in continuous flow, which integrates microfluidics, a gas-diffusion module and a potentiometric detection system. The analytical features achieved are a linear range from 30 to 1000 μmol L NH , a detection limit of 18 μmol L NH and a required sample volume of 100 μL, which comply with the medical requirements. Plasma and blood samples are analyzed with no significant differences observed between ammonium concentrations obtained with both the proposed microanalyzer and the reference method. This demonstrates the value of the developed POC for bedside clinical applications.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Rapid warning microanalyzer for heavy metals monitoring in natural waters

  • Pascual-Esco, Alex
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
  • Puyol, Mar|||0000-0002-9274-2284
A warning microanalyzer for the rapid monitoring of different heavy metals in water using Carbon Dots (CDs) as selective optical reagents is presented. The synthesized CDs have different surface functionalization and exhibit selective fluorescence quenching by heavy metal ions, that combined with the use of microfluidics, provide sensitivity, ease of automation and reproducibility to the method. Moreover, they present maximum excitation wavelengths around 350 nm, allowing multiparametric analysis with a single light source. Although quantum yields range from 16 % to 78 % depending on the type of CDs, enough sensitivity is achieved for each heavy metal using the same measurement conditions of the optical detection system (lock-in modulating frequency, signal amplitude and measurement frequency). The microanalyzer is composed of a Cyclic Olefin Copolymer (COC) analytical microsystem, a flow management system, and a miniaturized customized optical detection system. In this paper, we demonstrate that our proposed system can be used as a toxicity control system by selectively measuring five different heavy metal ions (Co, Cu, Hg, Ni, and Pb) with detection limits ranging from 2 to 12 ppb. Spiked tap water samples were analyzed, giving recoveries from 98 % to 134 %. Polluted samples containing four of the five heavy metal ions studied (Co, Cu, Ni, and Pb) were also analyzed with no significant differences observed between both methods, the proposed microanalyzer and the reference method (ICP-OES).
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Serum/plasma potassium monitoring using potentiometric point-of-care microanalyzers with improved ion selective electrodes

  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Arasa-Puig, Eva|||0000-0002-0702-0069
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
  • Puyol, Mar|||0000-0002-9274-2284
Different causes can trigger imbalances on homeostatic mechanisms between intracellular and extracellular compartments resulting in abnormal blood potassium concentrations (hypo or hyperkalemia). This can lead to serious consequences, even a life-threatening situation. Early diagnosis, treatment and follow-up are essential to minimize critical impacts in patients. Bedside determination of blood potassium is not accessible in all health care centers or in all emergency departments and far less common in this kind of centers in emerging countries. We have therefore proposed a portable, economic and long-lifetime potentiometric point-of-care (POC) analytical microsystem to deal with this question. It is a continuous flow microfluidic platform, made of cyclic olefin copolymer (COC), which combines microfluidics and a detection system based on the potentiometric technique containing a potassium selective electrode with a novel composition of polymeric membrane, which improves lifetime. Its size is smaller than a credit card and shows a linear range of Nernst calibration equation from 1 to 26 mM K+, a detection limit of 0.16 mM K+, a satisfactory repeatability and reproducibility, and an analysis frequency of 20 samples h-1, requiring only 25 μL as sample volume. Moreover, lifetime is as long as 9 months by intensive use. All these features comply with medical requirements. Human serum samples were analyzed with the developed device and the obtained results were compared with those provided by two methods: ICP-OES and another using ion selective electrodes. No significant differences were observed, demonstrating the suitability of the developed POC microanalyzer for bedside health applications.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Electrochemical genosensing of overexpressed GAPDH transcripts in breast cancer exosomes

  • Pallarès-Rusiñol, Arnau|||0000-0001-9990-148X
  • Lima Moura, Silio|||0000-0001-8867-6029
  • Martí, Mercè|||0000-0002-1846-0043
  • Pividori, María Isabel|||0000-0002-5266-7873
Exosomes are receiving highlighted attention as new biomarkers for the detection of cancer since they are profusely released by tumor cells in different biological fluids. In this paper, the exosomes are preconcentrated from the serum by immunomagnetic separation (IMS) based on a CD326 receptor as a specific epithelial cancer-related biomarker and detected by glyceraldehyde-3-phosphate dehydrogenase (GAPDH) transcripts. Following the lysis of the captured exosomes, the released GAPDH transcripts are amplified by reverse transcription polymerase chain reaction (RT-PCR) with a double-tagging set of primers on poly(dT)-modified-MPs to increase the sensitivity. The double-tagged amplicon is then quantified by electrochemical genosensing. The IMS/double-tagging RT-PCR/electrochemical genosensing approach is first demonstrated for the sensitive detection of exosomes derived from MCF7 breast cancer cells and compared with CTCs in terms of the analytical performance, showing an LOD of 4 × 102 exosomes μL-1. The genosensor was applied to human samples by immunocapturing the exosomes directly from serum from breast cancer patients and showed a higher electrochemical signal (3.3-fold, p < 0.05), when compared with healthy controls, suggesting an overexpression of GAPDH on serum-derived exosomes from breast cancer patients. The detection of GAPDH transcripts is performed from only 1.0 mL of human serum using specific magnetic particles, improving the analytical simplification and avoiding ultracentrifugation steps, demonstrating to be a promising strategy for minimal invasive liquid biopsy.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Improved biosensing of Legionella by integrating filtration and immunomagnetic separation of the bacteria retained in filters

  • Mesas Gómez, Melania|||0000-0002-3297-1077
  • Molina-Moya, Barbara|||0000-0001-5144-2165
  • de Araújo, Bárbara Camila
  • Boldrin Zanoni, Maria Valnice|||0000-0002-2296-1393
  • Julián, Esther|||0000-0002-6558-3978
  • Domínguez, José|||0000-0001-7888-0309
  • Pividori, María Isabel|||0000-0002-5266-7873
A novel approach is presented that combines filtration and the direct immunomagnetic separation of the retained bacteria Legionella in filters, for further electrochemical immunosensing. This strategy allows for the separation and preconcentration of the water-borne pathogen from high-volume samples, up to 1000 mL. The limit of detection of the electrochemical immunosensor resulted in 100 CFU mL-1 and improved up to 0.1 CFU mL-1 when the preconcentration strategy was applied in 1 L of sample (103-fold improvement). Remarkably, the immunosensor achieves the limit of detection in less than 2.5 h and simplified the analytical procedure. This represents the lowest concentration reported to date for electrochemical immunosensing of Legionella cells without the need for pre-enrichment or DNA amplification. Furthermore, the study successfully demonstrates the extraction of bacteria retained on different filtering materials using immunomagnetic separation, highlighting the high efficiency of the magnetic particles to pull out the bacteria directly from solid materials. This promising feature expands the applicability of the method beyond water systems for detecting bacteria retained in air filters of air conditioning units by directly performing the immunomagnetic separation in the filters.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Mycobacterium detection method combining filtration, immunomagnetic separation, and electrochemical readout in a portable biosensing device

  • Mesas Gómez, Melania|||0000-0002-3297-1077
  • Molina-Moya, Barbara|||0000-0001-5144-2165
  • de Araújo, Bárbara Camila
  • Pallarès-Rusiñol, Arnau|||0000-0001-9990-148X
  • Ferrer-Dalmau, Jofre|||0000-0002-7415-6222
  • Boldrin Zanoni, Maria Valnice|||0000-0002-2296-1393
  • Domínguez, José|||0000-0001-7888-0309
  • Julián, Esther|||0000-0002-6558-3978
  • Pividori, María Isabel|||0000-0002-5266-7873
This study addresses a straightforward and highly sensitive approach for detecting Mycobacterium fortuitum. The method involves a combination of filtration and direct immunomagnetic separation to isolate the bacteria retained on filters for further electrochemical magneto immunosensing in a handheld device. Unlike conventional methods involving pre-enrichment by culturing, this approach employs a simplified preconcentration technique, which includes filtration of large water samples, up to 100 mL, followed by a one-step process of immunomagnetic separation and labeling. After a 60-min, during which the filter with the retained bacteria and all the reagents (including modified magnetic particles and enzymatic conjugates) are incubated, the resulting product is directly drop into a cartridge, capable of performing magnetic actuation and washing. The electrochemical readout is carried out on a portable battery-operated device within 30 seconds. Remarkably, the immunosensor demonstrates an outstanding limit of detection of 5 CFU mL-1 in hemodialysis water processing 100 mL of sample. This achievement is remarkable considering the short and simplified analytical procedure, compared to the traditional isolation and culturing of mycobacteria, which typically takes 2 weeks.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Automated analytical microsystem for the spectrophotometric monitoring of titratable acidity in white, rosé and red wines

  • Sández, Natàlia|||0000-0003-1712-3552
  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Vidigal, Susana S.M.P.|||0000-0002-0213-063X
  • Rangel, António O.S.S.|||0000-0002-6486-8947
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
The design, construction and evaluation of a low-cost cyclic olefin copolymer (COC)-based continuous flow microanalyzer with optical detection to determine the titratable acidity content of wine is here presented. The analysis method is based on the monitoring of the blue coloration decrease of a buffered bromothymol blue (BTB) solution in the presence of the acidic compounds of wine. The microanalyzer monolithically integrates the required microfluidic motifs as well as an optical flow cell where the measurements are performed by using a miniaturized and versatile photometric detection system. Fluid management is totally automated by the use of computer-controlled microvalves, permitting the automatic calibration of the system as well as the automatic sampling, including in-line dilution and analysis. The reduced size of the whole system along with its high simplicity and automation make it suitable for its application to the on-line monitoring of titratable acidity during wine-making processes. With the optimal conditions, a linear range up to 0.50 g L-1 tartaric acid, a quantification limit (LOQ) of 0.01 g L-1 and a detection limit (LOD) of 0.004 g L-1 were obtained, covering the most common acidity content of musts and wines. A sampling rate up to 26 h-1 could be achieved, consuming less than 3 mL of inexpensive reagents per analysis and requiring no pretreatment of the sample. The microsystem has been successfully applied to the quantification of the titratable acidity content of several wine samples, being the results in excellent agreement with the ones obtained by the reference method.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Soluble reactive phosphorous determination in wastewater treatment plants by automatic microanalyzers

  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Ymbern Llorens, Oriol|||0000-0003-1997-6794
  • Puyol, Mar|||0000-0002-9274-2284
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
The analysis of soluble reactive phosphate (SRP) in water is key to control water quality. In order to continuous monitor orthophosphate content in water during treatment processes and in the effluents of wastewater treatment plants, conventional procedures, usually performed in a laboratory, must be adapted. This means pursuing efforts on miniaturizing systems to operate in situ and automating analytical methods to work on-line. The design, construction and evaluation of an automatic and low cost cyclic olefin copolymer (COC)-based spectrophotometric microanalyzer, capable of operating in unattended conditions, is presented to monitor soluble reactive phosphorous, as orthophosphate ion, in wastewater samples coming from sewage treatment plants. The microsystem, constructed by CNC micromilling and using a multilayer approach, integrates microfluidics to carry out the phosphomolybdenum blue (PMB) reaction and an optical flow-cell for the spectrophotometric orthophosphate determination in a single polymeric substrate smaller than a credit card. It is connected to a compact optical detection system composed by a LED emitting at 660 nm and a PIN-photodiode, both integrated in a PCB. Flow management is automatically performed by programmed microvalves and micropumps, which control autocalibration processes and allow unattended operation. Analytical features after the optimization of the microfluidic platform and the chemical and the hydrodynamic variables, were a linear range from 0.09 to 32 mg L-1 P and a detection limit of 0.03 mg L-1 P with a sampling rate of 24 samples h-1, demonstrating the microanalyzer suitability for SRP monitoring in water. Moreover, real samples were analyzed obtaining promising results.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Monitoring of total potassium in winemaking processes using a potentiometric analytical microsystem

  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Martinez-Bassedas, Ernest
  • Puyol, Mar|||0000-0002-9274-2284
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
Innovation in products and processes, traceability, food security and quality control are inherent challenges in agri-food sector. Trends in wine production are focused on obtaining natural wines with less chemical intervention. Following this goal, a low cost miniaturized, easy-to-use and highly automated microanalyzer to monitor total potassium in winemaking processes is presented. The microsystem monolithically integrates microfluidics as well as a potentiometric detection system and does not require any sample pretreatment. The analytical features provided are a linear range from 250 to 4000 mg L-1 K+, covering all the concentrations expected in must and wine samples, a detection limit of 75 ± 12 mg L-1 K+, and an adequate reproducibility and repeatability. Sample throughput is calculated at 20 h-1 with a waste volume generation lower than 4 mL per analysis. The microsystem lifetime is at least 4 months. Different wine and grape juice samples have been analyzed reaching outstanding results.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Evaluating smartphone-based optical readouts for immunoassays in human and veterinary healthcare, A comparative study

  • Mesas Gómez, Melania|||0000-0002-3297-1077
  • Julián, Esther|||0000-0002-6558-3978
  • Armengou Ruiz, Lara|||0000-0003-4715-7323
  • Pividori, María Isabel|||0000-0002-5266-7873
Recent advances have significantly enhanced the use of smartphone devices for medical diagnostics. This study uses high-resolution cameras in mobile devices to capture and process bioassay images, enabling the quantification of diverse biomarkers across a range of diagnostic tests conducted on 96-well microplates. The study evaluates the effectiveness of this technology through protein quantification techniques and immunoassays that generate colorimetric responses at specific wavelengths. It includes the assessment of bicinchoninic acid and Bradford protein quantification methods, alongside a conventional immunoassay for detecting mare antibodies in colostrum to monitor foal immunodeficiencies. Further application involves the readout of magneto-actuated immunoassays aimed at quantifying bacteria. The results obtained from benchtop spectrophotometry at 595, 562, and 450 nm are compared with those acquired using a smartphone, which identified color intensities in shades of blue, purple, and yellow. This comparison yields promising correlations for the samples tested, suggesting a high degree of accuracy in the smartphone capability to analyze bioassay outcomes. The analysis via smartphone is facilitated by a specific app, which processes the images captured by the phone camera to quantify color intensities corresponding to different biomarker concentrations. Detection limits of 12.3 and 22.8 μg mL for the bicinchoninic acid assay and 36.7 and 45.4 μg mL for the Bradford are obtained for protein quantification using the spectrophotometer and the smartphone app, respectively. For mare's antibodies in colostrum, the values are 1.14 and 1.72 ng mL, while the detection of E. coli is performed at 2.0 x 10 and 2.9 × 10 CFU mL, respectively. This approach offers further advantages, including wide availability, cost-effectiveness, portability, compared to traditional and expensive benchtop instruments.