Pasar al contenido principal

ESTRATEGIAS INNOVADORAS DE SENSADO BASADAS EN LA TECNOLOGIA DE MICROSISTEMAS PARA LAS DEMANDAS ANALITICAS ACTUALES EN MEDIO AMBIENTE, AGROALIMENTARIO Y BIOMEDICINA

PID2020-117216RB-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2020
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD AUTONOMA DE BARCELONA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 17
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Novel autocalibration strategy for disposable potentiometric test strips

  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Garrido Carretero, Laia|||0009-0005-5464-886X
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
  • Puyol, Mar|||0000-0002-9274-2284
Potentiometry, particularly involving ion-selective electrodes (ISEs), is widely employed in laboratories due to its selectivity and compatibility with portable instruments. However, ISEs face a drawback -instability over time, requiring frequent calibration for precise and reliable results. This manual calibration process contradicts the user-friendly concept and inhibits the development of single-use quantitative devices for untrained personnel. To solve this limitation, a novel potentiometric autocalibration procedure, which is automated, is presented, and successfully tested for the first time with versatile potentiometric disposable test strips to perform the determination of chloride ion in sweat as a demonstrator. The test strips are based on a cyclic olefin copolymer platform, where two identical Ag/AgCl chloride ISEs are integrated, one acting as indicator and the other as reference electrode. Comparison of chloride results in real sweat samples between those obtained with the proposed test strips performing the novel autocalibration procedure and using ion chromatography reveals that the automated procedure effectively allows quantitative chloride ion analysis with good analytical features: linear range from 10 to 150 mM (covering the pathological range), average inter-method error of 7 % and average RSD between test strips of 4 %. By carefully selecting the initial solution composition in direct contact with each electrode, the autocalibration ensures that potentiometric test strips can be calibrated just before its use without requiring conscious user involvement. This breakthrough not only streamlines the process but also opens the possibility for the development of cheap disposable potentiometric test strips, accessible to non-experts operators, to quantitatively determine selected analytes in different fields.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Ketocyanine-Based Materials for Near Infrared-to-Visible Thermochromism

  • López, Alex Julià
  • Muñoz Pérez, Noel
  • Magerramov, Ruslan
  • Puyol, Mar|||0000-0002-9274-2284
  • Crugeira, Ferran|||0000-0001-8464-8725
  • Miltsov, Sergey
  • Ruiz-Molina, Daniel|||0000-0002-6844-8421
  • Roscini, Claudio|||0000-0002-0157-8934
Thermochromic materials with tunable optical absorption over the NIR and visible spectral regions, and exhibiting colorless-to-colored transitions, are of interest in relevant applications such as invisible security inks or solar light-energy management. Despite so, the most common commercial thermochromic materials, based on phase-change-material mixtures of spirocompounds (leuco-dyes), allow narrow spectral modulation within the UV/vis regions and mostly produce colored-to-colorless transition, hampering their applicability beyond novelty products. In contrast, materials intrinsically thermochromic in the NIR, require time-consuming syntheses for their spectral and transition temperature tunability. Herein these challenges are overcome by replacing conventional leuco-dyes with Ketocyanines that exhibit strong color sensitivity on external multifactor, i.e. polarity, aggregation state, and pH, through different intermolecular interaction mechanisms, allowing fine and straightforward spectral tunability. Their absorption can be further shifted to the NIR region (λmax = 870 nm) by increasing the number of methine units, giving access to the desired colorless-to-colored transition (Δλ = 280 nm), via negative thermochromism. The preserved transitions of the microstructured mixtures are of interest for future thermochromic inks. Finally, their acid/base vapors response makes these multistimuli responsive materials highly attractive for applications such as anti-counterfeiting, bioimaging, and optical information storage for food packaging.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Multilayered Manufacturing Method for Microfluidic Systems Using Low-Cost, Resin-Based Three-Dimensional Printing

  • Manqueros-Avilés, Victor Edi
  • Coto-Fuentes, Hesner|||0000-0002-9548-7864
  • Guevara Amatón, Karla Victoria
  • Valdés-Perezgasga, Francisco|||0000-0002-7176-3641
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
This work presents a multilamination method for fabricating microfluidic devices or analytical microsystems using commercial 3D printers and photocurable resins as primary components. The developed method was validated by fabricating devices for the colorimetric measurement of copper ions in aqueous solutions, achieving results comparable to traditional cyclic olefin copolymer (COC) systems. The microfluidic platforms demonstrated stability and functionality over a twelve-week testing period. Channels with minimum dimensions of 0.4 mm × 0.4 mm were fabricated, and the feasibility of using resin modules for optical applications was demonstrated. This study highlights the potential of combining 3D printing with multilamination procedures as a versatile alternative, offering flexibility through the selection of a variety of available resins and commercial printers, as well as the ease of design development. This method offers significant reductions in cost, time, and manufacturing complexity by eliminating the need for equipment such as CNC machines, presses, and ovens, which are typically required in other multilamination technologies like LTCC and COC.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Pine bio-oil based biorefinery procedure for the production of antioxidants, acids, and sugars

  • Mora, Mireia|||0000-0001-5417-3052
  • Fàbregas, Esteve|||0000-0003-4681-4918
  • Céspedes, Francisco|||0000-0002-0296-6314
  • Puy, Neus|||0000-0002-6003-5200
In this study, a wood-based biorefinery with Pinus halepensis biomass was developed to obtain acids, sugars, and antioxidants with high recovery yields. Pine wood residues from sustainable forest management are transformed into bio-oil (BO) and separated into value-added chemicals with an integrated and innovative methodology. First, biomass is thoroughly characterized and the optimum operational parameters to produce BO are determined, the maximum yield being obtained at 450 °C. Second, BO is processed using a novel approach that integrates adsorption chromatography, vacuum distillation, liquid-liquid extraction, and precipitation, all of which are mature techniques at an industrial scale. This methodology offers a step forward to a more integrated strategy than current studies in the literature, allowing the simultaneous recovery of multiple chemicals rather than focusing only on the separation of a single family of compounds. The BO was divided into three fractions: (1) an acid-rich fraction, containing polar compounds with low boiling points such as acetic acid, formic acid, acetol, and furfural; (2) a sugar-rich fraction, containing polar compounds with higher boiling points like levoglucosan, 5-hydroxymethylfurfural (5HMF), and methyl cyclopentenolone, and (3) an antioxidant fraction, containing phenolic species with antioxidant properties such as phenol, guaiacol, catechol and vanillin. Elevated recovery yields were obtained: 69 wt% of the initial acetic acid with a value of 18 g·kg biomass, 92 wt% of the initial levoglucosan with a value of 10 g·kg biomass, and 65 wt% of the initial phenol with a value of 0.7 g·kg biomass. This represents a step forward in the development of biorefineries and the integrated production of chemicals for the pharmaceutical, nutraceutical, and chemical industries from a renewable feedstock: wood.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Production and separation of value-added compounds from pine wood using pyrolysis and biorefinery techniques

  • Mora, Mireia
  • Fàbregas, Esteve
  • Céspedes, Francisco
  • Puy, Neus
Value-added compounds were obtained from pine wood bio-oil, converting it into a renewable source for several chemicals: acids (acetic acid), sugars (levoglucosan), furan derivatives (furfural) and phenolics (catechol, phenol, 4-propylguaiacol, vanillin). To achieve this, firstly a comparison of a direct pyrolysis at 500 ◦C versus a twostaged pyrolysis (300 ◦C and 500 ◦C) was made. It was determined that a two-staged pyrolysis ensue in the obtainment of less complex liquid fractions since it concentrates families of compounds in different phases of biooil, facilitating their subsequent separation. Secondly, two methodologies (A and B) were designed to establish a procedure for separating the various chemical groups present in bio-oil. Methodology A consisted of a first vacuum distillation followed by an extraction process that combined an alkaline extraction and a simple extraction with ethyl acetate. Methodology B consisted of a first extraction with trioctylamine and ethyl acetate followed by a vacuum distillation and an extraction with hot water. The results showed that methodology A was better for the separation of chemical compounds from bio-oil, obtaining one fraction with the carboxylic acid content and furan derivatives, a second fraction containing the phenolic compounds and a third fraction enriched with the sugar content., We would also like to acknowledge the financial support of the LIFE Programme of the European Union for the project LIFE BIOREFFORMED (LIFE 19 ENV/ES/ 000544) and the support of the MINECO for the project PID2020- 117216RB-100 and the Group of Sensors and Biosensors of the Universitat Autonoma ` de Barcelona
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Dialysis and column chromatography for biomass pyrolysis liquids separation

  • Mora, Mireia
  • Fàbregas, Esteve
  • Céspedes, Francisco
  • Rovira, Pere
  • Puy, Neus
In the current study, a novel approach for separating value-added chemicals from pine wood residues’ pyrolysis liquids (bio-oil) was effectively carried out. It combined two separation techniques used for the first time in this field: dialysis with water, methanol and acetone, and column chromatography with Amberlite™ XAD7 resin. This strategy made it possible to separate bio-oil into four fractions: (1) pyrolytic lignin, which can be utilized in the synthesis of resins, foams, electrodes, asphalt, etc. (2) acid-rich fraction, with particular relevance to the chemical industry, (3) antioxidant fraction, containing phenolic compounds, with a lot of interest for pharmaceutical and nutraceutical industry, and (4) a final fraction containing the most non-polar chemicals from bio-oil. Thus, it was possible to develop a process that allows the obtention of bioproducts from woody biomass, a residue obtained in significant quantities in the management of non-profitable forests, making a step forward within the context of circular economy and bioeconomy., This work was supported by the LIFE Programme of the European Union with the project LIFE BIOREFFORMED [LIFE 19 ENV/ES/ 000544]; and the MINECO [PID2020-117216RB-100]. We would also like to acknowledge the support from the group of Sensors and Biosensors of the Universitat Autonoma ` de Barcelona.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Ketocyanine-Based Materials for Near Infrared-to-Visible Thermochromism

  • Julià-López, Alex
  • Muñoz Pérez, Noel
  • Magerramov, Ruslan
  • Puyol, Mar
  • Crugeira, Ferran
  • Miltsov, Sergey
  • Ruiz Molina, Daniel
  • Roscini, Claudio
Thermochromic materials with tunable optical absorption over the NIR and visible spectral regions, and exhibiting colorless-to-colored transitions, are of interest in relevant applications such as invisible security inks or solar light-energy management. Despite so, the most common commercial thermochromic materials, based on phase-change-material mixtures of spirocompounds (leuco-dyes), allow narrow spectral modulation within the UV/vis regions and mostly produce colored-to-colorless transition, hampering their applicability beyond novelty products. In contrast, materials intrinsically thermochromic in the NIR, require time-consuming syntheses for their spectral and transition temperature tunability. Herein these challenges are overcome by replacing conventional leuco-dyes with Ketocyanines that exhibit strong color sensitivity on external multifactor, i.e. polarity, aggregation state, and pH, through different intermolecular interaction mechanisms, allowing fine and straightforward spectral tunability. Their absorption can be further shifted to the NIR region (λmax = 870 nm) by increasing the number of methine units, giving access to the desired colorless-to-colored transition (Δλ = 280 nm), via negative thermochromism. The preserved transitions of the microstructured mixtures are of interest for future thermochromic inks. Finally, their acid/base vapors response makes these multistimuli responsive materials highly attractive for applications such as anti-counterfeiting, bioimaging, and optical information storage for food packaging., A.J.L. and N.M.P. equally contributed to this work. A.J. and N.M. acknowledge grant PID2021-127983OB-C21, and PID2020-117216RB-I00 funded by MCIU/AEI/10.13039/501100011033/ and ERDF A way of making Europe and with the grant TED2021-131709B-I00 funded by MCIU/AEI/10.13039/501100011033 and by the European Union NextGenerationEU/PRTR. The ICN2 is funded by the CERCA program/Generalitat de Catalunya and supported by the Severo Ochoa Centres of Excellence program, Grant CEX2021-001214-S, funded by MCIU/AEI/10.13039.501100011033. F.C. acknowledges the Industrial PhD program, funded by “Agència de Gestió d'Ajuts Universitaris i de Recerca (AGAUR) under Secretaria d'Universitats i Recerca de la Generalitat de Catalunya N° 2020-DI-2”., With funding from the Spanish government through the "Severo Ochoa Centre of Excelence" accreditation (CEX2021-001214-S), Peer reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Dialysis and column chromatography for biomass pyrolysis liquids separation

  • Mora, Mireia
  • Fàbregas, Esteve
  • Céspedes, Francisco
  • Rovira, Pere
  • Puy, Neus
In the current study, a novel approach for separating value-added chemicals from pine wood residues’ pyrolysis liquids (bio-oil) was effectively carried out. It combined two separation techniques used for the first time in this field: dialysis with water, methanol and acetone, and column chromatography with Amberlite™ XAD7 resin. This strategy made it possible to separate bio-oil into four fractions: (1) pyrolytic lignin, which can be utilized in the synthesis of resins, foams, electrodes, asphalt, etc. (2) acid-rich fraction, with particular relevance to the chemical industry, (3) antioxidant fraction, containing phenolic compounds, with a lot of interest for pharmaceutical and nutraceutical industry, and (4) a final fraction containing the most non-polar chemicals from bio-oil. Thus, it was possible to develop a process that allows the obtention of bioproducts from woody biomass, a residue obtained in significant quantities in the management of non-profitable forests, making a step forward within the context of circular economy and bioeconomy., This work was supported by the LIFE Programme of the European Union with the project LIFE BIOREFFORMED [LIFE 19 ENV/ES/ 000544]; and the MINECO [PID2020-117216RB-100]. We would also like to acknowledge the support from the group of Sensors and Biosensors of the Universitat Autonoma ` de Barcelona.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Production and separation of value-added compounds from pine wood using pyrolysis and biorefinery techniques

  • Mora, Mireia
  • Fàbregas, Esteve
  • Céspedes, Francisco
  • Puy, Neus
Value-added compounds were obtained from pine wood bio-oil, converting it into a renewable source for several chemicals: acids (acetic acid), sugars (levoglucosan), furan derivatives (furfural) and phenolics (catechol, phenol, 4-propylguaiacol, vanillin). To achieve this, firstly a comparison of a direct pyrolysis at 500 ◦C versus a twostaged pyrolysis (300 ◦C and 500 ◦C) was made. It was determined that a two-staged pyrolysis ensue in the obtainment of less complex liquid fractions since it concentrates families of compounds in different phases of biooil, facilitating their subsequent separation. Secondly, two methodologies (A and B) were designed to establish a procedure for separating the various chemical groups present in bio-oil. Methodology A consisted of a first vacuum distillation followed by an extraction process that combined an alkaline extraction and a simple extraction with ethyl acetate. Methodology B consisted of a first extraction with trioctylamine and ethyl acetate followed by a vacuum distillation and an extraction with hot water. The results showed that methodology A was better for the separation of chemical compounds from bio-oil, obtaining one fraction with the carboxylic acid content and furan derivatives, a second fraction containing the phenolic compounds and a third fraction enriched with the sugar content., We would also like to acknowledge the financial support of the LIFE Programme of the European Union for the project LIFE BIOREFFORMED (LIFE 19 ENV/ES/ 000544) and the support of the MINECO for the project PID2020- 117216RB-100 and the Group of Sensors and Biosensors of the Universitat Autonoma ` de Barcelona
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Biomedical point-of-care microanalyzer for potentiometric determination of ammonium ion in plasma and whole blood

  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Rebollo Calderón, Beatriz|||0000-0001-5968-8004
  • Ormazábal, Aida
  • Artuch, R.|||0000-0002-3422-9685
  • Rosell Ferrer, Javier|||0000-0002-9691-328X
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
  • Puyol, Mar|||0000-0002-9274-2284
Some inborn errors of metabolism and other diseases can result in increasing blood ammonium (hyperammonemia episodes), which can cause serious neurological complications in patients or even death. Early diagnosis, follow up and treatment are essential to minimize irreversible damages in brain. Currently, adequate analytical instrumentation for the necessary ammonium bedside determination is not available in all health centers but only in clinical laboratories of reference hospitals. We therefore have developed a low cost and portable potentiometric Point-of-Care microanalyzer (POC) to address this problem. It consists of a cyclic olefin copolymer-based microanalyzer, the size of a credit card and working in continuous flow, which integrates microfluidics, a gas-diffusion module and a potentiometric detection system. The analytical features achieved are a linear range from 30 to 1000 μmol L NH , a detection limit of 18 μmol L NH and a required sample volume of 100 μL, which comply with the medical requirements. Plasma and blood samples are analyzed with no significant differences observed between ammonium concentrations obtained with both the proposed microanalyzer and the reference method. This demonstrates the value of the developed POC for bedside clinical applications.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Fluorescence Imaging Characterization of the Separation Process in a Monolithic Microfluidic Free-Flow Electrophoresis Device Fabricated Using Low-Temperature Co-Fired Ceramics

  • Couceiro, Pedro|||0000-0001-5539-2441
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
A monolithic microfluidic free-flow electrophoresis device, fabricated using low-temperature co-fired ceramic technology, is presented. The device integrates gold electrodes and a 20 µm thick transparent ceramic optical window, suitable for fluorescence imaging, into a multilevel microfluidic chamber design. The microfluidic chamber consists of a 60 µm deep separation chamber and two, 50 µm deep electrode chambers separated by 10 µm deep side channel arrays. Fluorescence imaging was used for in-chip, spatial-temporal characterization of local pH variations in separation conditions as well as to characterize the separation process. The device allowed baseline resolution separation of a sample mixture of Fluorescein, Rhodamine 6G, and 4-Methylumbelliferone at pH 7.0, in only 6 s, using 378 V.s/cm. The results demonstrate the possibility of studying a chemical process using fluorescence imaging within the traditional fields of low-temperature co-fired ceramics technology, such as high-electrical-field applications, while using a simple fabrication procedure suitable for low-cost mass production.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Rapid warning microanalyzer for heavy metals monitoring in natural waters

  • Pascual-Esco, Alex
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
  • Puyol, Mar|||0000-0002-9274-2284
A warning microanalyzer for the rapid monitoring of different heavy metals in water using Carbon Dots (CDs) as selective optical reagents is presented. The synthesized CDs have different surface functionalization and exhibit selective fluorescence quenching by heavy metal ions, that combined with the use of microfluidics, provide sensitivity, ease of automation and reproducibility to the method. Moreover, they present maximum excitation wavelengths around 350 nm, allowing multiparametric analysis with a single light source. Although quantum yields range from 16 % to 78 % depending on the type of CDs, enough sensitivity is achieved for each heavy metal using the same measurement conditions of the optical detection system (lock-in modulating frequency, signal amplitude and measurement frequency). The microanalyzer is composed of a Cyclic Olefin Copolymer (COC) analytical microsystem, a flow management system, and a miniaturized customized optical detection system. In this paper, we demonstrate that our proposed system can be used as a toxicity control system by selectively measuring five different heavy metal ions (Co, Cu, Hg, Ni, and Pb) with detection limits ranging from 2 to 12 ppb. Spiked tap water samples were analyzed, giving recoveries from 98 % to 134 %. Polluted samples containing four of the five heavy metal ions studied (Co, Cu, Ni, and Pb) were also analyzed with no significant differences observed between both methods, the proposed microanalyzer and the reference method (ICP-OES).
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Serum/plasma potassium monitoring using potentiometric point-of-care microanalyzers with improved ion selective electrodes

  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Arasa-Puig, Eva|||0000-0002-0702-0069
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
  • Puyol, Mar|||0000-0002-9274-2284
Different causes can trigger imbalances on homeostatic mechanisms between intracellular and extracellular compartments resulting in abnormal blood potassium concentrations (hypo or hyperkalemia). This can lead to serious consequences, even a life-threatening situation. Early diagnosis, treatment and follow-up are essential to minimize critical impacts in patients. Bedside determination of blood potassium is not accessible in all health care centers or in all emergency departments and far less common in this kind of centers in emerging countries. We have therefore proposed a portable, economic and long-lifetime potentiometric point-of-care (POC) analytical microsystem to deal with this question. It is a continuous flow microfluidic platform, made of cyclic olefin copolymer (COC), which combines microfluidics and a detection system based on the potentiometric technique containing a potassium selective electrode with a novel composition of polymeric membrane, which improves lifetime. Its size is smaller than a credit card and shows a linear range of Nernst calibration equation from 1 to 26 mM K+, a detection limit of 0.16 mM K+, a satisfactory repeatability and reproducibility, and an analysis frequency of 20 samples h-1, requiring only 25 μL as sample volume. Moreover, lifetime is as long as 9 months by intensive use. All these features comply with medical requirements. Human serum samples were analyzed with the developed device and the obtained results were compared with those provided by two methods: ICP-OES and another using ion selective electrodes. No significant differences were observed, demonstrating the suitability of the developed POC microanalyzer for bedside health applications.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Production and separation of value-added compounds from pine wood using pyrolysis and biorefinery techniques

  • Mora, Mireia|||0000-0001-5417-3052
  • Fàbregas, Esteve|||0000-0003-4681-4918
  • Céspedes, Francisco|||0000-0002-0296-6314
  • Bartrolí i Molins, Jordi|||0000-0001-9968-4286
  • Puy, Neus|||0000-0002-6003-5200
Value-added compounds were obtained from pine wood bio-oil, converting it into a renewable source for several chemicals: acids (acetic acid), sugars (levoglucosan), furan derivatives (furfural) and phenolics (catechol, phenol, 4-propylguaiacol, vanillin). To achieve this, firstly a comparison of a direct pyrolysis at 500 °C versus a two-staged pyrolysis (300 °C and 500 °C) was made. It was determined that a two-staged pyrolysis ensue in the obtainment of less complex liquid fractions since it concentrates families of compounds in different phases of bio-oil, facilitating their subsequent separation. Secondly, two methodologies (A and B) were designed to establish a procedure for separating the various chemical groups present in bio-oil. Methodology A consisted of a first vacuum distillation followed by an extraction process that combined an alkaline extraction and a simple extraction with ethyl acetate. Methodology B consisted of a first extraction with trioctylamine and ethyl acetate followed by a vacuum distillation and an extraction with hot water. The results showed that methodology A was better for the separation of chemical compounds from bio-oil, obtaining one fraction with the carboxylic acid content and furan derivatives, a second fraction containing the phenolic compounds and a third fraction enriched with the sugar content.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Dialysis and column chromatography for biomass pyrolysis liquids separation

  • Mora, Mireia|||0000-0001-5417-3052
  • Fàbregas, Esteve|||0000-0003-4681-4918
  • Céspedes, Francisco|||0000-0002-0296-6314
  • Rovira, Pere|||0000-0002-9450-5020
  • Puy, Neus|||0000-0002-6003-5200
In the current study, a novel approach for separating value-added chemicals from pine wood residues' pyrolysis liquids (bio-oil) was effectively carried out. It combined two separation techniques used for the first time in this field: dialysis with water, methanol and acetone, and column chromatography with Amberlite™ XAD7 resin. This strategy made it possible to separate bio-oil into four fractions: (1) pyrolytic lignin, which can be utilized in the synthesis of resins, foams, electrodes, asphalt, etc. (2) acid-rich fraction, with particular relevance to the chemical industry, (3) antioxidant fraction, containing phenolic compounds, with a lot of interest for pharmaceutical and nutraceutical industry, and (4) a final fraction containing the most non-polar chemicals from bio-oil. Thus, it was possible to develop a process that allows the obtention of bioproducts from woody biomass, a residue obtained in significant quantities in the management of non-profitable forests, making a step forward within the context of circular economy and bioeconomy.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Live synthesis of selective carbon dots as fluorescent probes for cobalt determination in water with an automatic microanalyzer

  • Pascual-Esco, Alex
  • Lleonart, Pere
  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
  • Puyol, Mar|||0000-0002-9274-2284
A new strategy integrating the straight synthesis of carbon dots (CDs) and their direct use for the determination of heavy metals by means of fuorescence quenching is presented. The proposal consists of a modular analyzer, which includes a low temperature co-fred ceramics (LTCC) microreactor for the synthesis of CDs and a cyclic olefn copolymer (COC) microfuidic platform, which automatically performs a reverse fow injection analysis (rFIA) protocol for the determination of heavy metal ions in water by CD fuorescence quenching. As a proof of concept, nitrogen-doped CDs were synthesized from acrylic acid and ethylenediamine (ED) with quantum yields (QYs) of up to 44%, which are selective to cobalt. With the described system, we synthesized homogeneous CDs without the need for further purifcation and with the minimum consumption of reagents, and optimized fuorescence measurements can be performed with freshly obtained luminescent nanomaterials that have not undergone decomposition processes. They have an averagehydrodynamic diameter of 4.2±0.9 nm and maximum excitation and emission wavelengths at 358 nm and 452 nm, respectively. The system allows the automatic dilution and bufering of the synthesized CDs and the sample prior to the determination of cobalt. The concentration of cobalt was determined with good sensitivity and a limit of detection of 7 μg·L-1 with a linear range of 0.02-1 mg·L-1 of Co2+. Spiked tap water and river water samples were analyzed, obtaining recovery from 98 to 104%. This demonstrates the potential of the equipment as an efcient on-site control system for heavy metal monitoring in water.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Highly versatile and automated total ammonia nitrogen compact analyzer suitable for different types of water samples

  • Calvo-López, Antonio|||0000-0003-2728-8676
  • Alonso-Chamarro, Julián|||0000-0002-6804-6027
  • Puyol, Mar|||0000-0002-9274-2284
Continuous monitoring of total ammonia nitrogen (TAN) currently needs to improve further not only to meet optimal analytical features but also to reduce equipment maintenance needs and avoid manual intervention. The development, evaluation in different aqueous samples (fresh and wastewater) and validation of a fully automated and adaptable miniaturized potentiometric analytical instrument with this purpose are presented. The main goals accomplished are a wider and adaptable working range (0.08 to 1000 mg L-1 NH4+) with a detection limit of 0.03 mg L-1 and a significant reduction of reagent and sample consumption, as well as waste generation, compared to current commercial potentiometric flow analyzers. Moreover, different programmable calibration and sample analysis protocols have been successfully applied. Finally, suitable analytical features in terms of accuracy and precision are achieved even with samples with very complex matrices without any pretreatment required.