Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Design, Calibration, and Evaluation of a Long-Range 3-D Infrared Positioning System Based on Encoding Techniques

  • Aparicio Esteve, Elena|||0000-0001-7886-312X
  • Hernández Alonso, Álvaro|||0000-0001-9308-8133
  • Ureña Ureña, Jesús|||0000-0003-1408-6039
Optical indoor positioning systems have experienced an increasing research interest during last years as they can provide 3D centimeter accuracy using LED lighting. In the case of having several LEDs emitting simultaneously and a receiver (e.g. the tag to be localized), these systems face important challenges, such as very high dynamic ranges with low Signal-to-Noise Ratios when the coverage area is increased, Multiple Access Interference (MAI), multipath and near-far effects, calibration issues (misalignments in the receiver and other intrinsic parameters), and so on. Previous work have already shown the feasibility of using LED emitters in combination with Quadrature Angular Diversity Aperture (QADA) receivers to implement positioning systems. This work further introduces new design considerations, tested on an experimental setup, to enlarge the emitter-receiver range, thus increasing the total coverage, while dealing with the aforementioned challenges. The system applies encoding techniques to each transmitter to solve the multiple access problem. The performance of two different types of codes has been compared, as well as their influence on the final estimation of the receiver?s position: one based on Kasami sequences and another based on Loosely Synchronous (LS) codes, derived from Complementary Sets of Sequences. At the receiver, the estimation of the incident point is constrained to angles at which the system can be linearized, and a specific calibration process for this type of sensor has also been defined and applied. The proposal has been finally validated with both, simulated and experimental results, in a large space of 2 2m2 (base), with a distance from transmitters to receiver of 3:4m (height). The experimental tests at distances up to 4 m, carried out after the calibration process, achieve average absolute errors bellow 10 cm for X and Y axis and around 20 cm for Z, and standard deviations below 4 cm for X and Y , and around 30 cm for Z., Agencia Estatal de Investigación, Universidad de Alcalá
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Evaluation of Multi-Sensor Fusion Methods for Ultrasonic Indoor Positioning

  • Mannay, Khaoula
  • Ureña Ureña, Jesús|||0000-0003-1408-6039
  • Hernández Alonso, Álvaro|||0000-0001-9308-8133
  • Villadangos Carrizo, José Manuel|||0000-0001-5900-0978
  • Machhout, Mohamed
  • Aguili, Taoufik
Indoor positioning systems have become a feasible solution for the current development of multiple location-based services and applications. They often consist of deploying a certain set of beacons in the environment to create a coverage volume, wherein some receivers, such as robots, drones or smart devices, can move while estimating their own position. Their final accuracy and performance mainly depend on several factors: the workspace size and its nature, the technologies involved (Wi-Fi, ultrasound, light, RF), etc. This work evaluates a 3D ultrasonic local positioning system (3D-ULPS) based on three independent ULPSs installed at specific positions to cover almost all the workspace and position mobile ultrasonic receivers in the environment. Because the proposal deals with numerous ultrasonic emitters, it is possible to determine different time differences of arrival (TDOA) between them and the receiver. In that context, the selection of a suitable fusion method to merge all this information into a final position estimate is a key aspect of the proposal. A linear Kalman filter (LKF) and an adaptive Kalman filter (AKF) are proposed in that regard for a loosely coupled approach, where the positions obtained from each ULPS are merged together. On the other hand, as a tightly coupled method, an extended Kalman filter (EKF) is also applied to merge the raw measurements from all the ULPSs into a final position estimate. Simulations and experimental tests were carried out and validated both approaches, thus providing average errors in the centimetre range for the EKF version, in contrast to errors up to the meter range from the independent (not merged) ULPSs., Agencia Estatal de Investigación, Universidad de Alcalá
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Using Perspective-n-Point Algorithms for a Local Positioning System Based on LEDs and a QADA Receiver

  • Aparicio Esteve, Elena|||0000-0001-7886-312X
  • Ureña Ureña, Jesús|||0000-0003-1408-6039
  • Hernández Alonso, Álvaro|||0000-0001-9308-8133
  • Pizarro Pérez, Daniel|||0000-0003-0622-4884
  • Moltó Orozco, David|||0000-0002-2790-3758
The research interest on location-based services has increased during the last years ever since 3D centimetre accuracy inside intelligent environments could be confronted with. This work proposes an indoor local positioning system based on LED lighting, transmitted from a set of beacons to a receiver. The receiver is based on a quadrant photodiode angular diversity aperture (QADA) plus an aperture placed over it. This configuration can be modelled as a perspective camera, where the image position of the transmitters can be used to recover the receiver?s 3D pose. This process is known as the perspective-n-point (PnP) problem, which is well known in computer vision and photogrammetry. This work investigates the use of different state-of-the-art PnP algorithms to localize the receiver in a large space of 2 2m2 based on four co-planar transmitters and with a distance from transmitters to receiver up to 3.4 m. Encoding techniques are used to permit the simultaneous emission of all the transmitted signals and their processing in the receiver. In addition, correlation techniques (match filtering) are used to determine the image points projected from each emitter on the QADA. This work uses Monte Carlo simulations to characterize the absolute errors for a grid of test points under noisy measurements, as well as the robustness of the system when varying the 3D location of one transmitter. The IPPE algorithm obtained the best performance in this configuration. The proposal has also been experimentally evaluated in a real setup. The estimation of the receiver's position at three particular points for roll angles of the receiver of g ={0º, 120º, 210º and 300º} using the IPPE algorithm achieves average absolute errors and standard deviations of 4.33 cm, 3.51cm and 28.90 cm; and 1.84 cm, 1.17cm and 19.80cm in the coordinates x, y and z, respectively. These positioning results are in line with those obtained in previous work using triangulation techniques but with the addition that the complete pose of the receiver (x, y, z, a, b, g) is obtained in this proposal., Agencia Estatal de Investigación, Universidad de Alcalá
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Dynamic Adjustment of Weighted GCC-PHAT for Position Estimation in an Ultrasonic Local Positioning System

  • Villadangos Carrizo, José Manuel|||0000-0001-5900-0978
  • Ureña Ureña, Jesus|||0000-0003-1408-6039
  • García Domínguez, Juan Jesús|||0000-0002-7121-8651
  • Jiménez Martín, Ana|||0000-0003-0713-0054
  • Hernández Alonso, Álvaro|||0000-0001-9308-8133
  • Pérez Rubio, María Del Carmen|||0000-0001-8271-6843
Ultrasonic local positioning systems (ULPS) have been brought to the attention of researchers as one of the possibilities that can be used for indoor localization. Acoustic systems combine a suitable trade-off between precision, ease of development, and cost. This work proposes a method for measuring the time of arrival of encoded emissions from a set of ultrasonic beacons, which are used to implement an accurate ULPS. This method uses the generalized cross-correlation technique with PHAT filter and weighting factor b (GCC-PHAT-b). To improve the performance of the GCC-PHAT-b in encoded emission detection, the employment is proposed of mixed-medium multiple-access techniques, based on code division and time division multiplexing of beacon emissions (CDMA and TDMA respectively), and to dynamically adjust the PHAT filter weighting factor. The receiver position is obtained by hyperbolic multilateration from the time differences of arrival (TDoA) between a reference beacon and the rest, thus avoiding the need for receiver synchronization. The results show how the dynamic adaptation of the weighting factor significantly reduces positioning errors from 20 cm to 2 cm in 80% of measurements. The simulated and real experiments prove that the proposed algorithms improve the performance of the ULPS in situations with lower signal-to-noise ratios (SNR) than 0 dB and in environments where the multipath effect makes it difficult to correctly detect the encoded ultrasonic emissions., Agencia Estatal de Investigación, Universidad de Alcalá
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Detecting relative amplitude of IR signals with active sensors and its application to a positioning system

  • Aparicio Esteve, Elena|||0000-0001-7886-312X
  • Hernández Alonso, Álvaro|||0000-0001-9308-8133
  • Ureña Ureña, Jesús|||0000-0003-1408-6039
  • Villadangos Carrizo, José Manuel|||0000-0001-5900-0978
  • Lluva Plaza, Sergio|||0000-0002-0050-2807
  • Pérez Rubio, María del Carmen|||0000-0001-8271-6843
Nowadays, there is an increasing interest in smart systems, e.g., smart metering or smart spaces, for which active sensing plays an important role. In such systems, the sample or environment to be measured is irradiated with a signal (acoustic, infrared, radio‐frequency…) and some of their features are determined from the transmitted or reflected part of the original signal. In this work, infrared (IR) signals are emitted from different sources (four in this case) and received by a unique quadrature angular diversity aperture (QADA) sensor. A code division multiple access (CDMA) technique is used to deal with the simultaneous transmission of all the signals and their separation (depending on the source) at the receiver’s processing stage. Furthermore, the use of correlation techniques allows the receiver to determine the amount of energy received from each transmitter, by quantifying the main correlation peaks. This technique can be used in any system requiring active sensing; in the particular case of the IR positioning system presented here, the relative amplitudes of those peaks are used to determine the central incidence point of the light from each emitter on the QADA. The proposal tackles the typical phenomena, such as distortions caused by the transducer impulse response, the near‐far effect in CDMA‐based systems, multipath transmissions, the correlation degradation from non‐coherent demodulations, etc. Finally, for each emitter, the angle of incidence on the QADA receiveris estimated, assuming that it is on a horizontal plane, although with any rotation on the vertical axis Z. With the estimated angles and the known positions of the LED emitters, the position (x, y, z) of the receiver is determined. The system is validated at different positions in a volume of 3 × 3 × 3.4 m3 obtaining average errors of 7.1, 5.4, and 47.3 cm in the X, Y and Z axes, respectively., Agencia Estatal de Investigación, Universidad de Alcalá, Junta de Comunidades de Castilla-La Mancha