Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Motor unit sampling from intramuscular micro-electrode array recordings

  • Grison, Agnese
  • Ibáñez Pereda, Jaime
  • Farina, Dario
Recordings of electrical activity from muscles allow us to identify the activity of pools of spinal motor neurons that send the neural drive for muscle activation. Decoding motor unit and motor neuron activity from muscle recordings can be performed by high-density (HD) electrode systems, both non-invasively (surface, HD-sEMG) and invasively (intramuscular, HD-iEMG). HD-sEMG recordings are obtained by grids placed on the skin surface while HD-iEMG signals can be acquired by micro-electrode arrays. While it has been shown that HD-iEMG allows the accurate decoding of a larger number of motor units when compared to HD-sEMG, the dependence of motor unit yield on the parameters of the micro-electrode arrays is still unexplored. Here, we used recently developed HD-iEMG electrodes to record from hundreds of recording sites within the muscle. This allowed us to investigate the impact of electrode number, inter-electrode distance, and the number of muscle insertions on the ability to sample motor units within the muscle. Specifically, we recorded both HD-sEMG and HD-iEMG from the Tibialis Anterior muscle of two healthy subjects at various contraction intensities (10%, 30%, and 70% of maximum voluntary contraction, MVC). For the first time, we present intramuscular recordings with more than 140 electrodes inside a single muscle, achieved through multiple implants of high-density micro-electrode arrays. Through systematic offline analyses of these recordings, we tested different electrode configurations to identify optimal setups for accurately capturing motor unit activity. The results revealed that the density of electrodes in the micro-electrode arrays is the most critical factor for maximising the number of identified motor units and ensuring very high accuracy. Comparisons between intramuscular and surface recordings also confirmed that HD-iEMG consistently captures larger and more stable numbers of motor units across subjects and contraction levels. These results undersc...
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Unlocking the full potential of high‐density surface EMG: novel non‐invasive high‐yield motor unit decomposition

  • Grison, Agnese
  • Mendez Guerra, Irene
  • Clarke, Alexander Kenneth
  • Muceli, Silvia
  • Ibáñez, Jaime
  • Farina, Dario
The decomposition of high‐density surface electromyography (HD‐sEMG) signals into motor unit discharge patterns has become a powerful tool for investigating the neural control of movement, providing insights into motor neuron recruitment and discharge behaviour. However, current algorithms, while effective under certain conditions, face significant challenges in complex scenarios, as their accuracy and motor unit yield are highly dependent on anatomical differences among individuals. To address this issue, we recently introduced Swarm‐Contrastive Decomposition (SCD), which dynamically adjusts the contrast function based on the distribution of the data. Here, we demonstrate the ability of SCD in identifying low‐amplitude motor unit action potentials and effectively handling complex decomposition scenarios. We validated SCD using simulated and experimental HD‐sEMG recordings and compared it with current state‐of‐the‐art decomposition methods under varying conditions, including different excitation levels, noise intensities, force profiles, sexes and muscle groups. The proposed method consistently outperformed existing techniques in both the quantity of decoded motor units and the precision of their firing time identification. Across different simulated excitation levels, SCD detected, on average, 25.9 ±5.8 motor units vs. 13.9 ± 2.7 found by a state‐of‐the‐art baseline approach. Across noise levels, SCD detected 19.8 ± 13.5 motor units, compared to 11.9 ± 6.9 by the baseline method. In simulated conditions of high synchronisation levels, SCD detected approximately three times as many motor units compared to previous methods (31.2 ± 4.3 for SCD, 10.5 ± 1.7 for baseline), while also significantly improving accuracy. These advancements represent a step forward in non‐invasive EMG technology for studying motor unit activity in complex scenarios. imageKey points High‐density surface electromyography (HD‐sEMG) decomposition provides information on how the nervous system controls muscles, but current methods struggle in complex conditions. Swarm‐Contrastive Decomposition (SCD) is a new approach that dynamically adjusts how signals are separated, improving accuracy and increasing the sample of detected motor units. SCD successfully identifies more motor units, including those with low‐amplitude signals, and performs well even in challenging conditions such as high‐interference signals. In simulated ballistic contractions, SCD detected three times more motor units than previous methods while improving accuracy. These advancements could improve non‐invasive studies of muscle function in movement, fatigue and neurological disorders.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Excitation of natural spinal reflex loops in the sensory-motor control of hand prostheses

  • Sagastegui Alva, Patrick G.
  • Boesendorfer, Anna
  • Aszmann, Oskar C.
  • Ibáñez, Jaime
  • Farina, Dario
Sensory feedback for prosthesis control is typically based on encoding sensory information in specific types of sensory stimuli that the users interpret to adjust the control of the prosthesis. However, in physiological conditions, the afferent feedback received from peripheral nerves is not only processed consciously but also modulates spinal reflex loops that contribute to the neural information driving muscles. Spinal pathways are relevant for sensory-motor integration, but they are commonly not leveraged for prosthesis control. We propose an approach to improve sensory-motor integration for prosthesis control based on modulating the excitability of spinal circuits through the vibration of tendons in a closed loop with muscle activity. We measured muscle signals in healthy participants and amputees during different motor tasks, and we closed the loop by applying vibration on tendons connected to the muscles, which modulated the excitability of motor neurons. The control signals to the prosthesis were thus the combination of voluntary control and additional spinal reflex inputs induced by tendon vibration. Results showed that closed-loop tendon vibration was able to modulate the neural drive to the muscles. When closed-loop tendon vibration was used, participants could achieve similar or better control performance in interfaces using muscle activation than without stimulation. Stimulation could even improve prosthetic grasping in amputees. Overall, our results indicate that closed-loop tendon vibration can integrate spinal reflex pathways in the myocontrol system and open the possibility of incorporating natural feedback loops in prosthesis control.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Intramuscular microelectrode arrays enable highly accurate neural decoding of finger tasks

  • Grison, Agnese
  • Ibáñez, Jaime
  • Muceli, Silvia
  • Kundu, Aritra
  • Baracat, Farah Ashraf Moustafa Mahmoud
  • Indiveri, Giacomo
  • Donati, Elisa
  • Farina, Dario
Decoding the activity of the nervous system is a critical challenge in neuroscience and neural interfacing. In this study, we present a neuromuscular recording system that enables large-scale sampling of muscle activity using microelectrode arrays with over 100 channels embedded in forearm muscles. These arrays captured intramuscular high-density signals that were decoded into patterns of activation of spinal motoneurons. In two healthy participants, we recorded high-density intramuscular activity during single- and multi-digit contractions, revealing distinct motoneuron recruitment patterns specific to each task. Based on these patterns, we achieved perfect classification accuracy (100%) for 12 single- and multi-digit tasks and over approximately 96% accuracy for up to 16 tasks, significantly outperforming state-of-the-art electromyogram classification methods. This intramuscular high-density system and classification method represent an advancement in neural interfacing, with the potential to improve human–computer interaction and the control of assistive technologies, particularly for replacing or restoring impaired motor function.