Pasar al contenido principal

Neural Interfacing the Central Nervous System to study and treat neurological conditions affecting movement

RYC2021-031905-I

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Desarrollar, Atraer y Retener Talento
Subprograma Subprograma Estatal de Incorporación
Convocatoria Ramón y Cajal
Año convocatoria 2021
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE ZARAGOZA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Motor potentials evoked by transcranial magnetic stimulation: interpreting a simple measure of a complex system

  • Spampinato, Danny Adrian
  • Ibáñez, Jaime
  • Rocchi, Lorenzo
  • Rothwell, John
Transcranial magnetic stimulation (TMS) is a non‐invasive technique that is increasingly used to study the human brain. One of the principal outcome measures is the motor‐evoked potential (MEP) elicited in a muscle following TMS over the primary motor cortex (M1), where it is used to estimate changes in corticospinal excitability. However, multiple elements play a role in MEP generation, so even apparently simple measures such as peak‐to‐peak amplitude have a complex interpretation. Here, we summarize what is currently known regarding the neural pathways and circuits that contribute to the MEP and discuss the factors that should be considered when interpreting MEP amplitude measured at rest in the context of motor processing and patients with neurological conditions. In the last part of this work, we also discuss how emerging technological approaches can be combined with TMS to improve our understanding of neural substrates that can influence MEPs. Overall, this review aims to highlight the capabilities and limitations of TMS that are important to recognize when attempting to disentangle sources that contribute to the physiological state‐related changes in corticomotor excitability.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Non-linearity in motor unit velocity twitch dynamics: implications for ultrafast ultrasound source separation

  • Lubel, Emma
  • Sgambato, Bruno Grandi
  • Rohlén, Robin
  • Ibánez, Jaime
  • Barsakcioglu, Deren Y.
  • Tang, Meng-Xing
  • Farina, Dario
Ultrasound (US) muscle image series can be used for peripheral human-machine interfacing based on global features, or even on the decomposition of US images into the contributions of individual motor units (MUs). With respect to state-of-the-art surface electromyography (sEMG), US provides higher spatial resolution and deeper penetration depth. However, the accuracy of current methods for direct US decomposition, even at low forces, is relatively poor. These methods are based on linear mathematical models of the contributions of MUs to US images. Here, we test the hypothesis of linearity by comparing the average velocity twitch profiles of MUs when varying the number of other concomitantly active units. We observe that the velocity twitch profile has a decreasing peak-to-peak amplitude when tracking the same target motor unit at progressively increasing contraction force levels, thus with an increasing number of concomitantly active units. This observation indicates non-linear factors in the generation model. Furthermore, we directly studied the impact of one MU on a neighboring MU, finding that the effect of one source on the other is not symmetrical and may be related to unit size. We conclude that a linear approximation is partly limiting the decomposition methods to decompose full velocity twitch trains from velocity images, highlighting the need for more advanced models and methods for US decomposition than those currently employed.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A particle swarm optimised independence estimator for blind source separation of neurophysiological time series

  • Grison, Agnese
  • Clarke, Alexander Kenneth
  • Muceli, Silvia
  • Ibáñez, Jaime
  • Kundu, Aritra
  • Farina, Dario
The decomposition of neurophysiological recordings into their constituent neural sources is of major importance to a diverse range of neuroscientific fields and neuroengineering applications. The advent of high density electrode probes and arrays has driven a major need for novel semi-automated and automated blind source separation methodologies that take advantage of the increased spatial resolution and coverage these new devices offer. Independent component analysis (ICA) offers a principled theoretical framework for such algorithms, but implementation inefficiencies often drive poor performance in practice, particularly for sparse sources. Here we observe that the use of a single non-linear optimization function to identify spiking sources with ICA often has a detrimental effect that precludes the recovery and correct separation of all spiking sources in the signal. We go on to propose a projection-pursuit ICA algorithm designed specifically for spiking sources, which uses a particle swarm methodology to adaptively traverse a polynomial family of non-linearities approximating the asymmetric cumulants of the sources. We robustly prove state-of-the-art decomposition performance on recordings from high density intramuscular probes and demonstrate how the particle swarm quickly finds optimal contrast non-linearities across a range of neurophysiological datasets.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Changes in high-frequency neural inputs to muscles during movement cancellation

  • Zicher, Blanka
  • Avrillon, Simon
  • Ibáñez, Jaime
  • Farina, Dario
Objective. Cortical beta (13–30 Hz) and gamma (30–60 Hz) oscillations are prominent in the motor cortex and are known to be transmitted to the muscles despite their limited direct impact on force modulation. However, we currently lack fundamental knowledge about the saliency of these oscillations at spinal level. Here, we developed an experimental approach to examine the modulations in high-frequency inputs to motoneurons under different motor states while maintaining a stable force, thus constraining behaviour. Approach. Specifically, we acquired brain and muscle activity during a ‘GO’/’NO-GO’ task. In this experiment, the effector muscle for the task (tibialis anterior) was kept tonically active during the trials, while participants (N = 12) reacted to sequences of auditory stimuli by either keeping the contraction unaltered (‘NO-GO’ trials), or by quickly performing a ballistic contraction (‘GO’ trials). Motor unit (MU) firing activity was extracted from high-density surface and intramuscular electromyographic signals, and the changes in its spectral contents in the ‘NO-GO’ trials were analysed. Main results. We observed an increase in beta and low-gamma (30–45 Hz) activity after the ‘NO-GO’ cue in the MU population activity. These results were in line with the brain activity changes measured with electroencephalography. These increases in power occur without relevant alterations in force, as behaviour was restricted to a stable force contraction. Significance. We show that modulations in motor cortical beta and gamma rhythms are also present in muscles when subjects cancel a prepared ballistic action while holding a stable contraction in a ‘GO’/’NO-GO’ task. This occurs while force levels produced by the task effector muscle remain largely unaltered. Our results suggest that muscle recordings are informative also about motor states that are not force-control signals. This opens up new potential use cases of peripheral neural interfaces.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Excitation of natural spinal reflex loops in the sensory-motor control of hand prostheses

  • Sagastegui Alva, Patrick G.
  • Boesendorfer, Anna
  • Aszmann, Oskar C.
  • Ibáñez, Jaime
  • Farina, Dario
Sensory feedback for prosthesis control is typically based on encoding sensory information in specific types of sensory stimuli that the users interpret to adjust the control of the prosthesis. However, in physiological conditions, the afferent feedback received from peripheral nerves is not only processed consciously but also modulates spinal reflex loops that contribute to the neural information driving muscles. Spinal pathways are relevant for sensory-motor integration, but they are commonly not leveraged for prosthesis control. We propose an approach to improve sensory-motor integration for prosthesis control based on modulating the excitability of spinal circuits through the vibration of tendons in a closed loop with muscle activity. We measured muscle signals in healthy participants and amputees during different motor tasks, and we closed the loop by applying vibration on tendons connected to the muscles, which modulated the excitability of motor neurons. The control signals to the prosthesis were thus the combination of voluntary control and additional spinal reflex inputs induced by tendon vibration. Results showed that closed-loop tendon vibration was able to modulate the neural drive to the muscles. When closed-loop tendon vibration was used, participants could achieve similar or better control performance in interfaces using muscle activation than without stimulation. Stimulation could even improve prosthetic grasping in amputees. Overall, our results indicate that closed-loop tendon vibration can integrate spinal reflex pathways in the myocontrol system and open the possibility of incorporating natural feedback loops in prosthesis control.