Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

A Chromatic Nanoswitcher for Thermal Monitoring of Cell Metabolism

  • Zhang, Fengchan|||0000-0003-0751-1009
  • París Ogáyar, Marina|||0000-0002-4816-7729
  • Artiga, Álvaro|||0000-0001-9475-6367
  • Hernando, Jordi|||0000-0002-1126-4138
  • Villar-Alvarez, Eva|||0000-0003-4023-1375
  • Lorenzo Rivera, Julia|||0000-0001-5659-6008
  • Salegi Ansa, Beñat|||0000-0001-5054-758X
  • Cogliati, Sara|||0000-0002-0374-3489
  • Formentini, Laura|||0000-0001-5641-821X
  • Haro-González, Patricia|||0000-0002-1568-3794
  • Ruiz-Molina, Daniel|||0000-0002-6844-8421
  • Otaegui, Jaume Ramon|||0000-0002-9596-8625
  • Roscini, Claudio|||0000-0002-0157-8934
  • Jaque, Daniel|||0000-0002-3225-0667
Accurate sensing of intracellular temperature is crucial for understanding and monitoring cell metabolism, serving as an initial step toward diagnosing conditions such as mitochondria-related diseases. However, thermal monitoring of cell metabolism is challenging due to the minimal temperature variations caused by intracellular metabolic activity (typically ≈1 °C) and by the risk of crosstalk in intracellular sensors. A novel type of intracellular thermal sensor is presented, based on silica nanocapsules filled with a thermo-responsive fluorescent medium. This medium undergoes a reversible phase transition from solid to liquid at temperatures ≈37 °C, inducing a chromatic switch that facilitates remote thermal sensing. The chromatic switchers exhibit a thermal sensitivity of ≈13% °C⁻¹ at 37 °C, one of the highest reported for intracellular thermal sensing. Notably, the thermal response is unaffected by external factors such as pH, ionic strength, and viscosity. Moreover, it is confirmed that the response of the sensors is not affected by the cellular activity, underscoring their reliability for cytoplasmic temperature measurements. The potential of these sensors is demonstrated by measuring intracellular heating during the metabolic switch from mitochondrial to glycolytic activity, showcasing their potential for real-time, precise thermal monitoring (<1 °C) of cell metabolism.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Otros (Other)

Accurate and Fast Thermal Sensing via Phase-Responsive Nanothermometers and Neural Networks

  • París Ogáyar, Marina
  • Ming, Liyan
  • Zhang, Fengchan
  • Ximendes, Erving
  • Marin, Riccardo
  • Lifante-Pedrola, Ginés
  • Serrano Rubio, Aída
  • Espinosa, Ana
  • Haro-González, Patricia
  • Hernando, Jordi
  • Ruiz Molina, Daniel
  • Otaegui, Jaume R.
  • Roscini, Claudio
  • Jaque, Daniel
Accurate, rapid, and remote temperature sensing at the nanoscale is essential for applications ranging from monitoring cellular thermodynamics to thermal management of microelectronic devices. Luminescent nanothermometers are promising candidates; however, their deployment is hindered by limited thermal sensitivity and cross-sensitivity to environmental factors that mimic temperature-induced luminescence changes. We introduce fluorescent chromatic nanoswitchers (CNSs), comprising silica nanocapsules incorporating a fluorescent dye within a thermoresponsive matrix. The matrix undergoes a solid-to-liquid phase transition, yielding an exceptional fluorescence lifetime sensitivity of 19% °C-1 at 37 °C. Crucially, the lifetime-based thermal readout provided by CNSs is resistant to environmental interference, ensuring reliable, reproducible temperature measurements. To enhance CNS performance, we integrate artificial neural networks (ANNs) for advanced lifetime signal processing, enabling faster and robust thermal readouts. Proof-of-concept experiments show that the synergy between high-sensitivity lifetime-based nanothermometers and ANN-driven analysis paves the way for next-generation thermal sensing technologies, offering improved responsiveness, real-time capabilities, and enhanced accuracy., M.P.O. acknowledges the financial support from MICINN for an FPU (FPU20/03166). L.M. acknowledges a scholarship from the China Scholarship Council (202108350018). F.Z. acknowledges a scholarship from the China Scholarship Council (202108440235). E.X. thanks the Community of Madrid for Project SI4/PJI/2024-00130 through a direct grant with Universidad Autónoma de Madrid and also acknowledges support from Grant RYC2023-044309-I, funded by MICIU/AEI (10.13039/501100011033) and the FSE. This work was supported by Grant PID2024-161565OB-C21 funded by MICIU/AEI/10.13039/501100011033/FEDER, UE, and CNS2022-135495 and PID2023-151078OB-I00 funded by MCIN/AEI/10.13039/501100011033 and by the European Union NextGenerationEU/PRTR. ICN2 is supported by the Severo Ochoa Centres of Excellence program, Grant CEX2021-001214-S, funded by MICIU/AEI/10.13039.501100011033. R.M. is grateful to the Spanish Ministerio de Ciencia, Innovación y Universidades for support to research through a Ramón y Cajal Fellowship (RYC2021-032913-I) and Project PID2022- 14210NA-I00 (NAMASTEPS) funded by MICIU/AEI/10.13039/5011000 11033 and by FEDER, EU. The ICMM-CSIC acknowledges support from the Severo Ochoa Centres of Excellence Program, Grant CEX2024-001445-S funded by MICIU/AEI/10.13039/501100011033. The UAB thanks the support from MICIU/AEI/10.13039.501100011033 (PID2022-141293OB-I00) and Generalitat de Catalunya (2021 SGR 00064 project). J.R.O. thanks the Generalitat de Catalunya (AGAUR) for his predoctoral FI fellowship. A.S. acknowledges financial support from Grant RYC2021-031236-I funded by MCIN/AEI/10.13039/501100011033 and by the “European Union NextGenerationEU/PRTR” and Project PID2021-124585NB-C33 funded by MCIN/AEI/10.13039/501100011033 and by “ERDF A way of making Europe”. A.E. acknowledges financial support from Project PID2024-161273OB-C21 funded by MCIN/AEI/10.13039/501100011033 and CNS2023-144689 funded by MCIN/AEI/10.13039/501100011033 and the “European Union NextGenerationEU/PRTR., With funding from the Spanish government through the "Severo Ochoa Centre of Excelence" accreditation (CEX2021-001214-S), With funding from the Spanish government through the "Severo Ochoa Centre of Excelence" accreditation (CEX2024-001445-S), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Light-Induced Accumulation of Micro- and Nanoplastics from Water Dispersion by Optoelectronic Lithium Niobate Platforms

  • Camarero, P.
  • Rincón, E.
  • Haro-González, P.
  • Agulló Rueda, F.
  • García-Cabañes, A.
  • Carrascosa, M.
Plastic contamination in marine and drinking water is a major concern in environmental research. Particularly, detection and identification of micro and nanometric particles remain as important challenges, and so, several emergent methods are currently being investigated. Here, an optoelectronic platform is presented for trapping and accumulating micro/nano-plastics dispersed in water. The system exploits the photo-induced electric fields generated by visible light in LiNbO3:Fe crystals. When light is focused on the crystal, the photogenerated electric field triggers successive ejection of tiny droplets from the aqueous sample. These droplets reach the illuminated surface and evaporate leaving behind accumulated particles. Efficient accumulation of polystyrene microparticles is achieved down to 1 µg L−1. The influence of plastic concentration and illumination time are characterized. Moreover, the method is further validated at the nanoscale using 140 nm diameter polystyrene (PS) nanoparticles. Its functionality in saline water dispersions is also confirmed although exhibiting a lower efficiency. Finally, the platform´s versatility is demonstrated by accumulating other plastic contaminants such as polyethylene (PE) and polymethyl-methacrylate (PMMA), and a mix of PE and PS. The resulting accumulation spots serve as suitable samples for plastic identification by Raman spectroscopy. Overall, these results highlight the potential of optoelectronic lithium niobate platforms for micro/nano-plastics capture, accumulation and Raman identification. © 2025 The Author(s). Advanced Materials Interfaces published by Wiley-VCH GmbH., This work was financed by Grants PID2020-116192RB-I00,PID2023-151078OB-I00 and CNS2022-135495 funded byMCIN/AEI/10.13039/501100011033, and TED2021-129937B-I00 fundedby MCIN/AEI/10.13039/501100011033 and the European Union. P.C.thanks the regional government of Comunidad de Madrid for the contract PIPF-2023/TEC-29840 and for the contract from Programa Investigo (Plande Recuperación, Transformación y Resiliencia) developed thanks toSEPE, Ministerio de Trabajo y Economía Social and the European Union through NextGeneration EU., Peer reviewed