Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Observador de alta ganancia con zona muerta ajustable para estimar la saturación de agua líquida en pilas de combustible tipo PEM, High gain observer with dynamic deadzone to estimate liquid water saturation in PEM fuel cells

  • Cecilia, A.
  • Costa-Castelló, R.
[EN] In the area of PEM fuel cells, water management remains one of the most challenging issues affecting PEMFC efficiency and lifetime. Liquid water active control and supervision techniques are limited by the absence of online sensors that can estimate the liquid water saturation. For this reason, this work presents the design of a state observer to estimate the cathode catalyst layer's liquid water saturation of an open-cathode PEM fuel cell. The proposed observer is based on High-Gain techniques, and is modified with a dynamic dead-zone which reduces the observer's noise sensibility. The results have been validated through numerical simulation and experiments. It is shown that, in the absence of noise, the proposed observer presents a similar performance than its non dead-zone equivalent. Moreover, in the presence of noise, the dead-zone significantly reduces the estimation error induced by it., [ES] En el campo de las pilas de combustible PEM, la gestión de agua líquida es una de las problemáticas más importantes que afectan a la eficiencia y vida útil del sistema. Las técnicas de control activo y supervisión del agua se ven limitadas por la ausencia de sensores que puedan medir la saturación de agua líquida en línea. Por eso, en este trabajo se presenta el diseño de un observador de estado para la estimación de la saturación de agua líquida en la capa catalizadora del cátodo de una pila de combustible PEM de cátodo abierto. El observador propuesto se basa en técnicas de alta ganancia. Además, se modifica con una función de zona muerta autoajustable con el fin de reducir su sensibilidad al ruido en la medida. Los resultados se han validado mediante simulación numérica y experimentación. Estos muestran que, en ausencia de ruido, el observador propuesto presenta unas prestaciones similares a las de su equivalente sin zona muerta. Además, en presencia de ruido, la zona muerta disminuye significativamente el error de estimación inducido por este., Este proyecto se ha financiado parcialmente por el proyecto DOVELAR (ref. RTI2018-096001-B-C32). Este trabajo se ha realizado con el apoyo de la Agencia Estatal de Investigación española a través del sello de excelencia de María de Maeztu, IRI (MDM-2016-0656). Este trabajo se ha financiado parcialmente por AGAUR of Generalitat de Catalunya a través de la subvención del grupo Advanced Control Systems (SAC) (2017 SGR 482). Este trabajo se ha realizado con el apoyo de ACCIÓ (Operational Program FEDER Catalunya 2014-2020) a través de REFER project (COMRDI15-1-0036-11).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Optimal energy management in a standalone microgrid, with photovoltaic generation, short-term storage, and hydrogen production

  • Cecilia Piñol, Andreu
  • Carroquino, Javier
  • Roda Serrat, Vicente
  • Costa Castelló, Ramon
  • Barreras Toledo, Felix Manuel
This paper addresses the energy management of a standalone renewable energy system. The system is configured as a microgrid, including photovoltaic generation, a lead-acid battery as a short term energy storage system, hydrogen production, and several loads. In this microgrid, an energy management strategy has been incorporated that pursues several objectives. On the one hand, it aims to minimize the amount of energy cycled in the battery, in order to reduce the associated losses and battery size. On the other hand, it seeks to take advantage of the long-term surplus energy, producing hydrogen and extracting it from the system, to be used in a fuel cell hybrid electric vehicle. A crucial factor in this approach is to accommodate the energy consumption to the energy demand and to achieve this, a model predictive control (MPC) scheme is proposed. In this context, proper models for solar estimation, hydrogen production, and battery energy storage will be presented. Moreover, the controller is capable of advancing or delaying the deferrable loads from its prescheduled time. As a result, a stable and efficient supply with a relatively small battery is obtained. Finally, the proposed control scheme has been validated on a real case scenario., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Parameter estimation algorithm of H-100 PEM fuel cell

  • Xing, Yashan
  • Costa Castelló, Ramon
  • Jing, Na
Best Oral Communication Award for Young Authors, atorgat pel comitè científic HYCELTEC 2019, Polymer electrolyte membrane fuel cells (PEMFCs) have been recognized as one of the most promising eneygy conversion devices for commercial application due to their specific advantages, such as low operation temperature, zero pollutant emission, and high efficiency, etc. Since PEMFC is a highly nonlinear system and some parameters are related to the operation condition, most existing models are difficult to accurately predict the PEMFC characteristics. Thus, it is necessary to exploit parameter estimation methods for PEMFC to online determine the unknown model parameters by using easily measurable data to obtain concrete models. Most of the parameter estimations schemes for PEMFC have been designed based on intelligent optimization techniques. However, optimization methods cannot address the estimation problem online since they focus exclusively on offline searching procedure, which introduces heavy computational costs in the practical implementation and thus cannot be used in the real-time applications. Therefore, this paper aims to exploit real-time adaptive parameter estimation methods for a nonlinear parametric PEMFC system., Peer Reviewed, Award-winning, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

An analysis of energy storage system interaction in a multi objective model predictive control based energy management in DC microgrid

  • Raveendran Nair, Unnikrishnan
  • Costa Castelló, Ramon
© 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., Non-deterministic generation from renewable sources have resulted in the incorporation energy storage systems in modern grids. Management of energy between different storage elements need to done optimally to ensure efficient operation of the grid. The intraday energy management problem is addressed in this work through an online model predictive control using multi objective optimisation. This work analyses the energy interaction among different storages when penalty weights in a multi objective optimisation problem is varied, in order to find an optimal scenario in terms of weight distribution. Different scenarios are identified and performance indices are proposed to achieve the same. The work also addresses implicitly the objective of minimising rate of degradation batteries. Simulation results are presented to aid in the analysis., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Observador de alta ganancia con zona muerta para pilas de combustible PEM de cátodo abierto

  • Cecilia Piñol, Andreu
  • Costa Castelló, Ramon
Premio al mejor trabajo en Ingeniería de Control presentado en las XL Jornadas de Automática, otorgado por el Comité Español de Automàtica, celebradas en Ferrol 2019, En este trabajo se presenta el diseño de un observador de estado para la estimación de la saturación de agua líquida en la capa catalizadora del cátodo de una pila de combustible PEM de cátodo abierto. El observador propuesto se basa en técnicas de alta ganancia, además se modifica con una función de zona muerta dinámica. En este trabajo se muestra que, en ausencia de ruido, el observador propuesto presenta unas prestaciones similares a las de su equivalente sin zona muerta. Además, en presencia de ruido, la zona muerta disminuye significativamente el error de estimación inducido por este., Peer Reviewed, Award-winning, Postprint (author's final draft)