Pasar al contenido principal

CARACTERIZACION ELECTROQUIMICA DE MEMBRANAS CERAMICAS NANOESTRUCTURADAS DE INTERCAMBIO IONICO PARA SU APLICACION EN REACTORES ELECTROQUIMICOS Y SISTEMAS ELECTRODIALITICOS.

CTQ2012-37450-C02-01

•
Nombre agencia financiadora Ministerio de Economía y Competitividad
Acrónimo agencia financiadora MINECO
Programa Programa Nacional de Proyectos de Investigación Fundamental
Subprograma Subprograma de Proyectos de Investigación Fundamental no Orientada
Convocatoria Proyectos I+D
Año convocatoria 2012
Plan Estatal 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Unidad de gestión Secretaría de Estado de Investigación, Desarrollo e Innovación
Centro beneficiario UNIVERSITAT POLITÈCNICA DE VALÈNCIA
Identificador persistente http://dx.doi.org/10.13039/501100003329

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Study of the zinc recovery from spent pickling baths by means of an electrochemical membrane reactor using a cation-exchange membrane under galvanostatic control

  • Carrillo Abad, Jordi
  • García Gabaldón, Montserrat|||0000-0003-4254-6733
  • Pérez-Herranz, Valentín|||0000-0002-4010-0888
The performance of a cation-exchange membrane (CEM) used for recovering zinc from real spent pickling baths is studied in this work. These spent baths contain high amounts of ZnCl2 and FeCl2 in aqueous HCl media. The results obtained with this membrane are compared with those obtained with an anion-exchange membrane (AEM) treating the same effluent. The effect of the presence or absence of initial zinc in the cathodic compartment is also studied. The absence of initial zinc in the cathodic compartment in the CEM experiments permits iron codeposition. Furthermore, the results obtained with the CEM are worse than those obtained with the AEM for all the figures of merit. This fact shows the need of filling the cathodic compartment with a synthetic zinc solution. The presence of zinc in the cathodic compartment from the beginning of the electrolysis not only inhibits iron codeposition but also favors zinc deposition as the hydrogen evolution reaction becomes a secondary reaction, improving by this way the results of all the figures of merit of the reactor with the CEM. A deep study about the effect of the applied current and the concentration of the synthetic zinc solution placed in the cathodic compartment permits to reach the equilibrium between the zinc transferred through the membrane and that deposited on the cathode. Therefore, the synthetic cathodic zinc is not consumed at any time. Moreover, under this circumstances iron codeposition is also avoided., The authors want to express their gratitude to the Generalitat Valenciana for a postgraduate Grant (GV/2010/029) and to the Ministerio de Economia y Competitividad for financing the project number CTQ2012-37450-C02-01/PPQ.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Effect of the equilibria of multivalent metal sulfates on the transport through cation-exchange membranes at different current regimes

  • Martí Calatayud, Manuel César|||0000-0002-0745-1918
  • García Gabaldón, Montserrat|||0000-0003-4254-6733
  • Pérez-Herranz, Valentín|||0000-0002-4010-0888
The transport of trivalent metals (Cr(III) and Fe(III)) through cation-exchange membranes is studied and compared with the transport of mono- and divalent ions by means of chronopotentiometry and current-voltage characteristics. The species present in solutions of sulfate salts of multivalent metals give rise to different transport properties depending on the applied current. The detection of various transition times in the chronopotentiograms and two limiting current densities in the current-voltage curves reveals a change in the species being transported in the diffusion boundary layers and inside the membrane phase. At overlimiting current regimes, two different mass transfer mechanisms can predominate depending on the electrolyte composition. For the most concentrated solutions, gravitational convection promotes a decrease in the diffusion boundary layer thickness and the resistance of the membrane system decreases, whereas electroconvection takes place for both concentrated and weak electrolytes when a certain threshold in the membrane voltage drop is surpassed. The initial salt concentration has a significant effect on the emergence of the overlimiting conductance, since the length of the plateau of the current-voltage curves diminishes as a consequence of the size of the cations involved and the equilibrium conditions in which they take part., Manuel-Cesar Marti-Calatayud wants to express his gratitude to Universitat Politecnica de Valencia for a postgraduate grant (Ref. 2010-12). This work was supported by Ministerio de Economia y Competitividad (Spain) with the project number CTQ2012-37450-C02-01/PPQ.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Anion transport through ceramic electrodialysis membranes made with hydrated cerium dioxide

  • Mora-Gómez, Julia
  • Mestre, Sergio
  • García Gabaldón, Montserrat|||0000-0003-4254-6733
  • Martí Calatayud, Manuel César|||0000-0002-0745-1918
  • Pérez-Herranz, Valentín|||0000-0002-4010-0888
[EN] In this research, low-cost ceramic anion-exchange membranes have been developed from porous supports manufactured, using a chamotte as a pore former. An inorganic anion-exchanger (hydrated cerium dioxide) has been deposited into the support and fixed by thermal treatment. The effects of some process variables (such as the temperature of the thermal treatment or the pH of the electrolyte) on the properties of the anion-exchange membranes have been investigated. The electrochemical performance of the resulting membranes has been compared to that exhibited by ceramic anion-exchange membranes based on another anion exchanger (hydrated zirconium dioxide) deposited into alumina-kaolin supports. The temperature of the thermal treatment applied to fix the hydrated cerium dioxide (HCeD) does not affect the structure nor the electrochemical properties of the membranes. The porosity of the supports obtained, using a chamotte as the pore former was lower than that of the alumina-kaolin ones, which led to a lower deposition of hydrated cerium dioxide than that obtained for hydrated zirconium dioxide (HZrD) in alumina-kaolin supports. The higher porosity registered for the HZrD-based membrane also implies higher membrane conductivities. The selective transport of anions through the membranes was enhanced by increasing the number of infiltrating steps, as confirmed from current to voltage curves. However, this behavior was only apparent at acidic or neutral pH, thus confirming the amphoteric character of the anion-exchanger. Comparing the parameter (equivalents of ion exchanger per gram of deposited oxide), it is concluded that the porosity of the ceramic supports, consequence of their distinct microstructure, is the main parameter responsible for the difference in the ion-exchange capacity obtained for HZrD and HCeD membranes. Consequently, the CeO2 particles used in this work are also good candidates to impart ion-exchange properties to microporous ceramic supports., Ministerio de Economia y Competitividad (Spain), Grant/Award Number: CTQ2012-3750-C02-01/PPQ, CTQ2012-3750-C02-02/PPQ
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Ceramic anion-exchange membranes based on microporous supports infiltrated with hydrated zirconium dioxide

  • Martí Calatayud, Manuel César|||0000-0002-0745-1918
  • García Gabaldón, Montserrat|||0000-0003-4254-6733
  • Pérez-Herranz, Valentín|||0000-0002-4010-0888
  • Sales, Sonia
  • Mestre, Sergio
Anion-exchange membranes made from inexpensive ceramic materials were synthesized by using a simple procedure based on incorporating particles of an ion exchanger into a host microporous structure. Microporous ceramics produced from alumina and kaolin were used as supports, and their internal voids were functionalized by direct precipitation of hydrated ZrO2. The addition of starch as pore former to the sintering mixture induces the formation of pores within the micrometer range, where the subsequent deposition of hydrated ZrO2 occurred preferentially. An increase in the loading of hydrated ZrO2 particles improved the ion exchange capacity (IEC) and induced anion-selective properties on the membranes. However, when more than six infiltration cycles were performed, the membrane porosity was substantially reduced. Electrochemical measurements conducted in acidic and neutral media corroborated the implication of the hydrated ZrO2 particles on the development of concentration polarization and confirmed the strong relationship existing between the membrane porosity and electrical conductivity. Conversely, chronopotentiometric curves showed that the membranes practically lack of ion-exchange properties when tested under alkaline conditions. The methodology proposed to synthesize ceramic ion-conducting membranes could significantly broaden the utilization of electromembrane processes in industrial applications where the use of polymeric membranes is restricted due to their expensive cost or poor chemical stability., This work was financially supported by the Ministerio de Economia y Competitividad (Spain) with the project number CTQ2012-3750-C02-01/PPQ and CTQ2012-3750-C02-02/PPQ.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Sulfuric acid recovery from acid mine drainage by means of electrodialysis

  • Martí Calatayud, Manuel César|||0000-0002-0745-1918
  • García Gabaldón, Montserrat|||0000-0003-4254-6733
  • Ortega Navarro, Emma María|||0000-0001-6902-018X
  • Pérez-Herranz, Valentín|||0000-0002-4010-0888
  • CARDOSO BUZZI, DANIELLA
  • Bernardes, A.M.
  • Suarez Tenorio, Jose Alberto
In the present work the recovery of sulfuric acid from acid mine drainage by means of 3-compartment electrodialysis (ED) is evaluated. An effective recovery of sulfuric acid free from Fe(III) species was obtained in the anodic compartment as a result of the co-ion exclusion mechanism in the membranes. The difference in the pH and pSO42 − values between the membrane phase and the external electrolyte promotes the dissociation of complex species inside the membranes. This phenomenon impedes the transport of Fe(III) and sulfates in the form of complex ions toward the anodic and cathodic compartment, respectively. The current efficiency values of the anion-exchange membrane at different current densities were approximately constant with time. However, the increase in the recovery of acid decreases as the current increases. This result is explained by the shift in the equilibrium at the membrane/solution interface as more SO42 − ions cross the anionic membrane and, by the enhancement of the dissociation of water when the limiting current density is exceeded. The main limitation of the process is related to an abrupt increase in the cell voltage due to the formation of precipitates at the surface of the cation-exchange membrane., This work was supported by Ministerio de Economia y Competitividad (Spain) with the project number CTQ2012-37450-C02-01/PPQ. M.C. Marti-Calatayud is grateful to the Universitat Politecnica de Valencia for a postgraduate grant (Ref.: 2010-12). D.C. Buzzi wants to express her gratitude to CAPES (Brazil) for a postgraduate grant (Proc. BEX 8747/11-3).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Ion transport through homogeneous and heterogeneous ion-exchange membranes in single salt and multicomponent electrolyte solutions

  • Martí Calatayud, Manuel César|||0000-0002-0745-1918
  • García Gabaldón, Montserrat|||0000-0003-4254-6733
  • Pérez-Herranz, Valentín|||0000-0002-4010-0888
  • Buzzi, Daniella Cardoso
  • BERNARDES, ANDREA MOURA
  • Tenório, Jorge Alberto Suarez
The increasing demand for clean industrial processes has intensified the use of electrodialysis in the treatment of metal containing effluents and encourages the investigation of the different phenomena involved in the transport of metal ions through cation-exchange membranes. Ion sorption, chronopotentiometric and current–voltage characteristics have been obtained to characterize the transport of sodium and iron through homogeneous and heterogeneous cation-exchange membranes. The heterogeneous membranes having a broader pore size distribution showed increased electrical resistances with solutions of trivalent iron, which may be caused by the blockage of the smallest pores by multivalent ions. However, for both types of membranes an unexpected decrease of the electrical resistance with increasing current densities was verified with concentrated solutions of Fe2(SO4)3. This behavior was explained to be a consequence of the dissociation of FeSO4+ ions into more conductive Fe3+ and SO42− ions as the depleting solution layer becomes diluted. When tested with multicomponent mixtures, the homogeneous perfluorosulfonic membranes show an increased preference for Na+ ions at low current densities and, once Na+ ions are depleted from the membrane surface Fe3+ ions are transported preferentially at higher current densities. On the contrary, both Na+ ions and Fe(III) species are responsible for the ion transport through the heterogeneous membranes within the ohmic regime of currents., This work was supported by the Ministerio de Economia y Competitividad (Spain) with the Project number CTQ2012-37450-C02-01/PPQ. M.C. Marti-Calatayud is grateful to the Universitat Politecnica de Valencia for a postgraduate grant (Ref. 2010-12). D.C. Buzzi wants to express her gratitude to CAPES (Brazil) for a postgraduate grant (Proc. BEX 8747/11-3).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Treatment of spent pickling baths coming from hot dip galvanizing by means of an electrochemical membrane reactor

  • Carrillo Abad, Jordi
  • García Gabaldón, Montserrat|||0000-0003-4254-6733
  • Pérez-Herranz, Valentín|||0000-0002-4010-0888
The performance of a one (OCR) and a two-compartment electrochemical reactor in the presence of a cation-exchange membrane (CEM) for the zinc recovery present in the spent pickling baths is analyzed in this paper under galvanostatic control. These solutions, which mainly contain ZnCl2 and FeCl2 in aqueous HCl media, come from the hot dip galvanizing industry. The effect of the applied current, the dilution factor of the baths and the presence or absence of initial cathodic zinc is also studied. For the 1:50 diluted spent bath, OCR experiments initially present higher values of the figures of merit than those obtained in the presence of the CEM since zinc is close to the cathode from the first electrolysis instants. However, at long electrolysis times, OCR presents zinc redissolution for all the current values tested due to the chlorine and iron presence close to the zinc deposits. In addition, the iron codeposition phenomenon is also observed in the OCR experiments when pH values are close to 2. On the other hand, CEM experiments become very similar to the OCR experiments at long time values since the CEM under these experimental conditions prevents zinc redissolution phenomenon and also iron codeposition. When the 1:50 diluted bath is concentred to 1:10, OCR experiments present the same tendency as that observed for the 1:50 dilution factor but the effect of zinc redissolution is increased due to the greater amount of chlorine generated in the anode. Under these experimental conditions, iron deposition has also been observed in the presence of the cation-exchange membrane as the rate of zinc deposition is greater than that of zinc transport through the membrane, and the zinc/iron ratio in the cathodic compartment is not high enough to prevent iron codeposition. In both cases, the pH values when iron codeposits with zinc are close to 2 and the zinc/iron ratio is below 0.6. The presence of initial zinc in the cathodic compartment of the electrochemical reactor enhances the reactor performance since it allows the zinc–iron separation in one single step and avoids the zinc redissolution phenomenon., The authors want to express their gratitude to the Generalitat Valenciana for a postgraduate grant (GV/2010/029) and to the Ministerio de Economia y Competitividad for financing the project number CTQ2012-37450-C02-01/PPQ.