Pasar al contenido principal

LENGUAS BIOELECTRONICAS CON TRANSDUCCION ELECTROQUIMICA. EXPLORANDO NUEVAS APLICACIONES.

CTQ2016-80170-P

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de Fomento de la Investigación Científica y Técnica de Excelencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D (Excelencia / Generación de Conocimiento)
Año convocatoria 2016
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD AUTONOMA DE BARCELONA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 11
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Label-free aptasensor for lysozyme detection using electrochemical impedance spectroscopy

  • Ortiz, Dionisia|||0000-0002-5637-8120
  • Valle, Manel del|||0000-0002-1032-8611
This research develops a label-free aptamer biosensor (aptasensor) based on graphite-epoxy composite electrodes (GECs) for the detection of lysozyme protein using Electrochemical Impedance Spectroscopy (EIS) technique. The chosen immobilization technique was based on covalent bonding using carbodiimide chemistry; for this purpose, carboxylic moieties were first generated on the graphite by electrochemical grafting. The detection was performed using [Fe(CN)]/[Fe(CN)] as redox probe. After recording the frequency response, values were fitted to its electric model using the principle of equivalent circuits. The aptasensor showed a linear response up to 5 µMfor lysozyme and a limit of detection of 1.67 µM. The sensitivity of the established method was 0.090 µM in relative charge transfer resistance values. The interference response by main proteins, such as bovine serum albumin and cytochrome c, has been also characterized. To finally verify the performance of the developed aptasensor, it was applied to wine analysis.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

A voltammetric electronic tongue for the resolution of ternary nitrophenol mixtures

  • González-Calabuig, Andreu|||0000-0002-6325-138X
  • Cetó, Xavier|||0000-0003-1589-6076
  • Valle, Manel del|||0000-0002-1032-8611
This work reports the applicability of a voltammetric sensor array able to quantify the content of 2,4-dinitrophenol, 4-nitrophenol, and picric acid in artificial samples using the electronic tongue (ET) principles. The ET is based on cyclic voltammetry signals, obtained from an array of metal disk electrodes and a graphite epoxy composite electrode, compressed using discrete wavelet transform with chemometric tools such as artificial neural networks (ANNs). ANNs were employed to build the quantitative prediction model. In this manner, a set of standards based on a full factorial design, ranging from 0 to 300 mg·L, was prepared to build the model; afterward, the model was validated with a completely independent set of standards. The model successfully predicted the concentration of the three considered phenols with a normalized root mean square error of 0.030 and 0.076 for the training and test subsets, respectively, and r ≥ 0.948.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Simultaneous voltammetric determination of acetaminophen, ascorbic acid and uric acid by use of integrated array of screen-printed electrodes and chemometric tools

  • Ortiz, Dionisia|||0000-0002-5637-8120
  • Bonet-SanEmeterio, Marta|||0000-0002-5076-8136
  • Valle, Manel del|||0000-0002-1032-8611
In the present work, ternary mixtures of Acetaminophen, Ascorbic acid and Uric acid were resolved using the Electronic tongue (ET) principle and Cyclic voltammetry (CV) technique. The screen-printed integrated electrode array having differentiated response for the three oxidizable compounds was formed by Graphite, Prussian blue (PB), Cobalt (II) phthalocyanine (CoPc) and Copper oxide (II) (CuO) ink-modified carbon electrodes. A set of samples, ranging from 0 to 500 µmol·L, was prepared, using a tilted (3) factorial design in order to build the quantitative response model. Subsequently, the model performance was evaluated with an external subset of samples defined randomly along the experimental domain. Partial Least Squares Regression (PLS) was employed to construct the quantitative model. Finally, the model successfully predicted the concentration of the three compounds with a normalized root mean square error (NRMSE) of 1.00 and 0.99 for the training and test subsets, respectively, and R ≥ 0.762 for the obtained vs. expected comparison graphs. In this way, a screen-printed integrated electrode platform can be successfully used for voltammetric ET applications.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Voltammetric electronic tongue for the simultaneous determination of three benzodiazepines

  • Herrera-Chacon, Anna|||0000-0002-6169-147X
  • Torabi, Farzad
  • Faridbod, Farnoush
  • Ghasemi, Jahan B.
  • González-Calabuig, Andreu|||0000-0002-6325-138X
  • Valle, Manel del|||0000-0002-1032-8611
The presented manuscript reports the simultaneous detection of a ternary mixture of the benzodiazepines diazepam, lorazepam, and flunitrazepam using an array of voltammetric sensors and the electronic tongue principle. The electrodes used in the array were selected from a set of differently modified graphite epoxy composite electrodes; specifically, six electrodes were used incorporating metallic nanoparticles of Cu and Pt, oxide nanoparticles of CuO and WO, plus pristine electrodes of epoxy-graphite and metallic Pt disk. Cyclic voltammetry was the technique used to obtain the voltammetric responses. Multivariate examination using Principal Component Analysis (PCA) justified the choice of sensors in order to get the proper discrimination of the benzodiazepines. Next, a quantitative model to predict the concentrations of mixtures of the three benzodiazepines was built employing the set of voltammograms, and was first processed with the Discrete Wavelet Transform, which fed an artificial neural network response model. The developed model successfully predicted the concentration of the three compounds with a normalized root mean square error (NRMSE) of 0.034 and 0.106 for the training and test subsets, respectively, and coefficient of correlation R ≥ 0.938 in the predicted vs. expected concentrations comparison graph.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Modification of electrodes with N-and S-doped carbon dots. Evaluation of the electrochemical response

  • Bonet-SanEmeterio, Marta|||0000-0002-5076-8136
  • Algarra, Manuel|||0000-0003-2410-8430
  • Petković, Marijana
  • Valle, Manel del|||0000-0002-1032-8611
Nitrogen and sulphur-doped Carbons Dots (N-CDs and S-CDs) were synthesized by a hydrothermal method and incorporated as surface electrode modifiers to evaluate their properties for electrochemical sensing. The first task was to characterize the synthesized materials, for which different spectroscopies, scanning microscopes, mass spectrometry and elementary analysis were performed. Next, a glassy carbon electrode (GCE) was surface-modified with the doped CDs and applied to check the electrochemical signal of different organic compounds corresponding to different families. Water solubility of the doped carbon dots forced us to incorporate them in a graphite-polystyrene ink to complete the modification of electrodes. This modification needed a first activation to obtain a properly conductive surface. The organic compounds examined were salicylic acid, cysteine and ascorbic acid. The modified GCEs exhibited an enhanced sensitivity, probably caused by the increase of active surface, but in addition, signals of salicylic acid were shifted ca. 200 mV to lower potentials, what is a proof of the increase of the heterogeneous electron transfer rate, and a demonstration of an enhanced catalytic response.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Improved sensing of capsaicin with TiO2 nanoparticles modified epoxy graphite electrode

  • Sarma, Munmi
  • Valle, Manel del|||0000-0002-1032-8611
The presented research focuses on the electrochemical determination of capsaicin, a lipophilic alkaloid which originates hotness in chili peppers. An electrochemical sensor based on epoxy-graphite composite with the modification of titanium dioxide (TiO2) nanoparticles is developed for the determination of this alkaloid. The measurements were carried out in glycine buffer at pH 2.5 using cyclic voltammetry. Two linear concentration ranges were obtained from 6 to 75 μM (R=0.99) and from 12 to 138 μM, with a detection limit of 5.34 μM and 11.3 μM capsaicin, for 1st and 2nd oxidation peak, respectively. The main advantage of developed sensor is its repeatability and robustness against fouling; the relative standard deviation (RSD) value was 2.53 % (n=10). This voltammetric sensing procedure has successfully been applied to quantify capsaicin in various real samples such as hot chili sauce and pharmaceutical preparations.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Avoiding nonsense in electronic taste sensing

  • Legin, Andrey
  • Kirsanov, Dmitry|||0000-0002-5667-6910
  • Valle, Manel del|||0000-0002-1032-8611
Last years have watched the birth and profusion of analytical systems known as "taste sensors" or "electronic tongues". Regardless of the fancy names, these "taste sensors" and "electronic tongues" are primarily analytical instruments and require responsible handling and application in order to provide for meaningful results. In spite of intensively reported scientific activities and even commercial availability of such devices, multisensor systems are still not widely used in routine laboratory and industrial practice but are rather research instruments. The purpose of this report is to critically analyze different aspects of multisensor systems' studies and to highlight problematic issues requiring special attention from the research community to keep staying objective with reported results and declared conclusions.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Integrating molecularly imprinted polymer beads in graphite-epoxy electrodes for the voltammetric biosensing of histamine in wines

  • Herrera-Chacon, Anna|||0000-0002-6169-147X
  • Dinç-Zor, Şule
  • Valle, Manel del|||0000-0002-1032-8611
This manuscript presents a voltammetric biosensing study with use of molecularly imprinted polymers to detect histamine in wine. Polymer beads were synthesized by standard precipitation polymerization method and implemented on the electrode surface via sol-gel immobilization. Scanning and confocal microscopy examinations permitted characterizing the material. Adsorptive stripping voltammetry in differential mode was the technique chosen for final application, selecting an enrichment time of 5 min. These conditions permitted a limit of detection of 0.19 μg mL -1 (1.0 μM), with a linear response range from 0.5 to 6.0 μg mL -1 (2.71-32.4 μM). The repeatability of the measurements was 4.6% relative standard deviation (n = 12). Principal component analysis showed the ability of the prepared receptor for discriminating other biogenic amines and potential interfering species. A final application, illustrating the determination of histamine, was completed to show agreement of results between the fluorimetric reference method and the proposed electrochemical approach.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Voltammetric electronic tongue based on carbon paste electrodes modified with biochar for phenolic compounds stripping detection

  • Kalinke, Cristiane
  • de Oliveira, Paulo Roberto
  • Bonet-SanEmeterio, Marta|||0000-0002-5076-8136
  • González-Calabuig, Andreu|||0000-0002-6325-138X
  • Valle, Manel del|||0000-0002-1032-8611
  • Salvio Mangrich, Antonio
  • Humberto Marcolino, Luiz
  • Bergamini, Márcio F.
Biochar is a charcoal produced from the biomass pyrolysis process that presents a highly porous and functionalized surface. In the present work an array of carbon paste electrodes (CPE) made of different forms of carbon (graphite, carbon nanotubes and activated biochar) was evaluated in the development of an electronic tongue for discrimination and stripping voltammetric determination of catechol (CAT), 4-ethylcatechol (4-EC) and 4-ethylguaiacol (4-EG) phenolic compounds. Morphological characterization of carbon materials and electrodes surfaces was performed by scanning electron microscopy (SEM) and semi-quantitative elemental composition by energy dispersive spectroscopy (EDS). Electrochemical Impedance Spectroscopy (EIS) measurements were used for electrochemical characterization of electrodes. Cyclic voltammetry measurements were performed for the phenolic compounds evaluated using different concentrations. Principal component analysis (PCA) was performed to evaluate the qualitative analysis. Quantitative data modeling was done using artificial neural networks (ANN). The proposed sensor array presented analytical potentiality allowing the distinction and determination of CAT, 4-EC and 4-EG by using chemometric processing. The method showed sensibility, reproducibility and a good linearity (R2.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Artificial neural networks for the resolution of dopamine and serotonin complex mixtures using a graphene-modified carbon electrode

  • Bonet-SanEmeterio, Marta|||0000-0002-5076-8136
  • González-Calabuig, Andreu|||0000-0002-6325-138X
  • Valle, Manel del|||0000-0002-1032-8611
This work explores an electrode modified with electrochemically reduced graphene oxide (ERGO) for the voltammetric resolution of mixtures of neurotransmitters and its most common interferents. This enhanced sensitivity device coupled with advanced chemometric tools, such as artificial neural networks (ANNs), is able to resolve and quantify complex mixtures with overlapped signals. In this case, it has been applied to dopamine (DA), serotonin (5-hydroxytryptamine, 5-HT) and its main physiologic interferents, ascorbic acid (AA) and uric acid (UA), which play a relevant role in human body. The results obtained for individual analysis make evident a higher sensitivity of the developed sensor than the unmodified electrode. Furthermore, it has been attained an ANN response model with good correlation ability allowing the separation and quantification of each compound with comparison slope of predicted vs. expected concentrations with correlation better than 0.974. In short, the developed ERGO-modified sensor not only improved the signal but it also permitted resolving and quantifying each compound in complex mixtures when the proper chemometric treatment was used.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Multivariate determination of total sugar content and ethanol in bioethanol production using carbon electrodes modified with MWCNT/MeOOH and chemometric data treatment

  • Cardoso de Sá, Acelino|||0000-0002-9811-4879
  • Cipri, Andrea
  • González-Calabuig, Andreu|||0000-0002-6325-138X
  • Stradiotto, Nelson Ramos
  • Valle, Manel del|||0000-0002-1032-8611
This work reports the characterization and application of a voltammetric electronic tongue using an array of glassy carbon electrodes modified with multi-walled carbon nanotubes containing metal (Pd, Au, Cu) and oxy-hydroxide nanoparticles (MetalsOOH of Ni, Co) towards the determination of total sugar content in products related with sugarcane-bioethanol production. The prediction model based on Artificial Neural Networks (ANN) has given satisfactory results for the carbohydrate sum and the obtained response had shown an adequate accuracy. Voltammetric data was first adapted for the computation using the Fast Fourier transform, and results from the electronic tongue approach were compared with use of different electrodes alone. Final performance was better using uniquely the Ni oxy-hydroxide modified electrode, especially in the quantification of ethanol, a side-effect of counter-balancing its interference.