Pasar al contenido principal

NUEVOS DESARROLLOS EN OPTICA VISUAL, VISION Y SISTEMAS HIPERESPECTRALES: APLICACIONES CLINICAS E INDUSTRIALES

DPI2011-30090-C02-01

•
Nombre agencia financiadora Ministerio de Ciencia e Innovación
Acrónimo agencia financiadora MICINN
Programa Programa Nacional de Proyectos de Investigación Fundamental
Subprograma Subprograma de Proyectos de Investigación Fundamental no Orientada
Convocatoria Proyectos I+D
Año convocatoria 2011
Plan Estatal 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Unidad de gestión Subdirección General de Proyectos de Investigación
Centro beneficiario UNIVERSITAT POLITECNICA DE CATALUNYA
Identificador persistente http://dx.doi.org/10.13039/501100004837

Resultados relacionados

Resultados totales (Incluyendo duplicados): 15
Encontrada(s) 1 página(s)

RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Study of color perceptibility of gonio‐apparent panels with curvature angle

  • Chorro, Elísabet
  • Perales, Esther
  • Viqueira, Valentín
  • Martínez-Verdú, Francisco M.
  • Perales, Esther|||/items/3c441acb-4c61-4b30-b94e-907ed26edd23
  • Martínez-Verdú, Francisco M.|||/items/1b2eb36f-ce01-47d8-b72f-b852349c01a7
Color tolerances of curved gonio‐apparent panels have been studied in this work. To achieve that, an experimental set‐up of the illumination and tilt variation of two identical coated panels was designed for simulation of curved panels with both concave and convex borders and with and without effect pigments (perceived as solid and gonio‐apparent colors, respectively). Finally, visual and instrumental measures were collected with both curvatures. The results show that the relationship of the instrumental color difference with the tilt angle can be modeled by a second‐order and the vertex did not depend on illumination, but on coating type. The critical angles (the angle marked when the color discrepancy between two identical samples is merely perceived) assessed by the observers showed that they were not equal according to border, nor according to coating type. The color tolerances at these angles were clearly higher than the conventional chromatic thresholds of industrial color comparisons.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Validation of a gonio-hyperspectral imaging system based on light-emitting diodes for the spectral and colorimetric analysis of automotive coatings

  • Burgos Fernández, Francisco Javier
  • Vilaseca Ricart, Meritxell
  • Perales, Esther
  • Chorro, Elísabet
  • Martínez-Verdú, Francisco M.
  • Fernández-Dorado, José
  • Pujol Ramo, Jaume
  • Perales, Esther|||/items/3c441acb-4c61-4b30-b94e-907ed26edd23
  • Martínez-Verdú, Francisco M.|||/items/1b2eb36f-ce01-47d8-b72f-b852349c01a7
In this study, a novel gonio-hyperspectral imaging system based on light-emitting diodes for the analysis of automotive coatings was validated colorimetrically and spectrally from 368 to 1309 nm. A total of 30 pearlescent, 30 metallic, and 30 solid real automotive coatings were evaluated with this system, the BYK-mac and X-Rite MA98 gonio-spectrophotometers, and also with the SPECTRO 320 spectrometer for further comparison. The results showed very precise correlations, especially in the visible range. In conclusion, this new system provides a deeper assessment of goniochromatic pigments than current approaches due to the expansion of the spectral range to the infrared.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Texture Evaluation of Automotive Coatings by Means of a Gonio-Hyperspectral Imaging System Based on Light-Emitting Diodes

  • Burgos Fernández, Francisco Javier
  • Pujol Ramo, Jaume
  • Perales, Esther
  • Martínez-Verdú, Francisco M.
  • Vilaseca Ricart, Meritxell
  • Perales, Esther|||/items/3c441acb-4c61-4b30-b94e-907ed26edd23
  • Martínez-Verdú, Francisco M.|||/items/1b2eb36f-ce01-47d8-b72f-b852349c01a7
Sparkle and graininess are textural effects that appear as intrinsic spatial features of coatings containing goniochromatic pigments, whereas others such as mottling are undesired outcomes. In this study, we present new methods for the evaluation of sparkle, graininess and mottling of automotive coatings through images acquired with a novel gonio-hyperspectral imaging system based on light-emitting diodes with extended spectral sensitivity beyond the visible range (368–1309 nm). A novel analysis of sparkle that considered the amount of sparkling spots was used. Graininess was quantified through a novel statistical descriptor based on the energy descriptor computed from the histogram. A new index was proposed for an enhanced detection of mottling based on the analysis of striping, which was better observed and quantified in the infrared range. Spectral assessments showed a strong relationship with color and spectral reflectance for graininess and mottling. In conclusion, the results showed that these new spatial and spectral methods are a suitable, alternative and potential approach for the assessment of these textural features.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Effects of aging on optical quality and visual function

  • Martínez Roda, Juan Antonio|||0000-0003-0222-7164
  • Vilaseca Ricart, Meritxell|||0000-0001-8166-1617
  • Ondategui Parra, Juan Carlos|||0000-0001-8090-6731
  • Aguirre, Montserrat
  • Pujol Ramo, Jaume|||0000-0003-0811-9244
Background: We assessed the effects of aging on visual function and optical quality in a healthy adult population and provide reference values for different age ranges. Methods: We conducted a prospective study with 198 healthy volunteers from31 to 70 years of age. The visual acuity (VA) and contrast sensitivity (CS) at 3, 6, 12 and 18cycles per degree (cpd) frequencies were assessed, together with values of optical quality and intraocular scatter- ing obtained with a double-pass system(Optical Quality Analysis System– OQAS), specifically the modulation transfer function cutoff frequency (MTFcutoff), the Strehl ratio, the OQAS values (OV) at contrasts of 100, 20 and nine per cent and the objective scatter index (OSI). We studied the change of these variables with age and obtained standard values for optical quality and intraocular scattering parameters for four age groups: 31 to 40, 41 to 50, 51 to 60 and 61 to 70 years. Results: We found significant correlations between age and all variables analysed and signifi- cant differences among the age groups considered except for CS (3 cpd) (p= 0.067). Ageing particularly affected low-contrast parameters, such as theOV nine per cent and theOSI, which decreased to 37 and 50 per cent of their original values, respectively.TheOSIwas found to pro- vide high sensitivity and specificity values, when healthy and caratactous eyes were considered. The results suggest that optical deficits are compensated until 50 years of age with sensory and perceptual factors, as smaller changes were found for visual function than for objective mea- surements of optical quality and intraocular scattering. Conclusions: Measures of optical quality assessed by subjective psychophysical and objective techniques varied differently with age. Values obtained for each age group can be used to de- termine normal limits of optical quality and intraocular scattering for diagnosis of ocular conditions.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Quantification of forward scattering based on the analysis of double-pass images in the frequency domain

  • Martínez Roda, Juan Antonio|||0000-0003-0222-7164
  • García Guerra, Carlos Enrique|||0000-0001-7013-9938
  • Díaz Douton, Fernando|||0000-0003-3699-015X
  • Pujol Ramo, Jaume|||0000-0003-0811-9244
  • Salvador, Antoni
  • Vilaseca Ricart, Meritxell|||0000-0001-8166-1617
The research leading to these results has receivedfunding from the Spanish Ministry for Science andInnovation (MICINN; DPI2011-30090-C02-01),from the European Union’s Horizon 2020 researchand innovation programme under the MarieSkłodowska–Curie grant agreement No. 712949(TECNIOspring PLUS) and from the Agency forBusiness Competitiveness of the Government ofCatalonia.e1026Acta Ophthalmologica2019
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

New compact open-field double-pass system with asymmetric focus, Nuevo sistema de doble-paso compacto con enfoque asimétrico

  • Giner Tort, Anna|||0000-0002-5487-979X
  • Arjona Carbonell, Mª Montserrat|||0000-0001-9040-8410
  • Díaz Douton, Fernando|||0000-0003-3699-015X
  • Aldaba Arévalo, Mikel|||0000-0001-5835-4395
  • García Guerra, Carlos Enrique|||0000-0001-7013-9938
  • Sanabria Ortega, Fernando Guillermo|||0000-0003-0326-6878
  • Pujol Ramo, Jaume|||0000-0003-0811-9244
Every day more people are using multifocal systems to correct presbyopia, as for example contact lenses or intraocular lenses. As a consequence, the necessity to do an appropriate characterization of their optical quality has increased. Due to this situation, the main purpose of this project has been to develop a new compact open-field double-pass system with asymmetric focus that characterizes objectively in vivo the optical quality of multifocal systems that are adapted or implanted in the eye. As a preliminary study, one diffractive and one refractive multifocal lens were implanted in a wet customized model-eye and characterized by this new set-up. Regarding the asymmetric focus of the set-up, a through-focus from +0.75 to -4.00D in steps of 0.25D was performed in the second pass for each tested lens,while the optical power of the first pass remained fixed. Results show that it is possible to distinguish, characterize the different foci of the measured multifocal intraocular lenses implanted in the model eye, and evaluate the optical quality of the system composed by the eye + the multifocal element. Therefore, it has been concluded that this new compact open-field double-pass system with asymmetric focus is suitable to evaluate the optical quality of multifocal systems adapted or implanted in the eye., Cada día más personas usan elementos ópticos multifocales para corregir la presbicia, por ejemplo una lente de contacto o una lente intraocular. En consecuencia, la necesidad de evaluar la calidad óptica del ojo con un elemento corrector multifocal ha adquirido una gran importancia. Dada esta situación, el principal objetivo de este proyecto ha sido desarrollar un nuevo sistema compacto basado en la técnica de doble-paso con enfoque asimétrico capaz de realizar una caracterización objetiva e “in vivo” de la calidad óptica del conjunto ojo-elemento óptico multifocal. En este estudio preliminar se han empleado dos lentes intraoculares multifocales, una difractiva y otra refractiva,implantadas en un ojo artificial. Al ser un sistema con enfoque asimétrico, se utilizó el segundo paso para realizar un barrido desde +0.75 a -4.00D en pasos de 0.25 D manteniendo el primer paso fijo. Los resultados han mostrado que es posible hallar y diferenciar los dos planos de enfoque, lejano y cercano, de las lentes intraoculares multifocales implantadas en el ojo artificial y evaluar la calidad óptica del conjunto ojoelemento multifocal. Por tanto, se ha demostrado la viabilidad de este nuevo sistema compacto de doble-paso con enfoque asimétrico para caracterizar la calidad óptica de un ojo con un elemento óptico multifocal.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Spherical subjective refraction with a novel 3D virtual reality based system

UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Texture evaluation of automotive coatings by means of a gonio-hyperspectral imaging system based on light-emitting diodes

  • Burgos Fernández, Francisco Javier|||0000-0002-3749-6850
  • Pujol Ramo, Jaume|||0000-0003-0811-9244
  • Perales Romero, Esther
  • Martínez Verdú, Francisco Miguel
  • Vilaseca Ricart, Meritxell|||0000-0001-8166-1617
Sparkle and graininess are textural effects that appear as intrinsic spatial features of coatings containing goniochromatic pigments, whereas others such as mottling are undesired outcomes. In this study, we present new methods for the evaluation of sparkle, graininess and mottling of automotive coatings through images acquired with a novel gonio-hyperspectral imaging system based on light-emitting diodes with extended spectral sensitivity beyond the visible range (368–1309 nm). A novel analysis of sparkle that considered the amount of sparkling spots was used. Graininess was quantified through a novel statistical descriptor based on the energy descriptor computed from the histogram. A new index was proposed for an enhanced detection of mottling based on the analysis of striping, which was better observed and quantified in the infrared range. Spectral assessments showed a strong relationship with color and spectral reflectance for graininess and mottling. In conclusion, the results showed that these new spatial and spectral methods are a suitable, alternative and potential approach for the assessment of these textural features., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Quantification of forward scattering based on the analysis of double-pass images in the frequency domain

  • Martínez Roda, Juan Antonio
  • García Guerra, Carlos Enrique
  • Díaz Douton, Fernando
  • Pujol Ramo, Jaume
  • Salvador, Antoni
  • Vilaseca Ricart, Meritxell
The research leading to these results has receivedfunding from the Spanish Ministry for Science andInnovation (MICINN; DPI2011-30090-C02-01),from the European Union’s Horizon 2020 researchand innovation programme under the MarieSkłodowska–Curie grant agreement No. 712949(TECNIOspring PLUS) and from the Agency forBusiness Competitiveness of the Government ofCatalonia.e1026Acta Ophthalmologica2019, Preprint
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Effects of aging on optical quality and visual function

  • Martínez Roda, Juan Antonio
  • Vilaseca Ricart, Meritxell
  • Ondategui Parra, Juan Carlos
  • Aguirre, Montserrat
  • Pujol Ramo, Jaume
Background: We assessed the effects of aging on visual function and optical quality in a healthy adult population and provide reference values for different age ranges. Methods: We conducted a prospective study with 198 healthy volunteers from31 to 70 years of age. The visual acuity (VA) and contrast sensitivity (CS) at 3, 6, 12 and 18cycles per degree (cpd) frequencies were assessed, together with values of optical quality and intraocular scatter- ing obtained with a double-pass system(Optical Quality Analysis System– OQAS), specifically the modulation transfer function cutoff frequency (MTFcutoff), the Strehl ratio, the OQAS values (OV) at contrasts of 100, 20 and nine per cent and the objective scatter index (OSI). We studied the change of these variables with age and obtained standard values for optical quality and intraocular scattering parameters for four age groups: 31 to 40, 41 to 50, 51 to 60 and 61 to 70 years. Results: We found significant correlations between age and all variables analysed and signifi- cant differences among the age groups considered except for CS (3 cpd) (p= 0.067). Ageing particularly affected low-contrast parameters, such as theOV nine per cent and theOSI, which decreased to 37 and 50 per cent of their original values, respectively.TheOSIwas found to pro- vide high sensitivity and specificity values, when healthy and caratactous eyes were considered. The results suggest that optical deficits are compensated until 50 years of age with sensory and perceptual factors, as smaller changes were found for visual function than for objective mea- surements of optical quality and intraocular scattering. Conclusions: Measures of optical quality assessed by subjective psychophysical and objective techniques varied differently with age. Values obtained for each age group can be used to de- termine normal limits of optical quality and intraocular scattering for diagnosis of ocular conditions., Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

New compact open-field double-pass system with asymmetric focus, Nuevo sistema de doble-paso compacto con enfoque asimétrico

  • Giner Tort, Anna
  • Arjona Carbonell, Mª Montserrat
  • Díaz Douton, Fernando
  • Aldaba Arévalo, Mikel
  • García Guerra, Carlos Enrique
  • Sanabria Ortega, Fernando Guillermo
  • Pujol Ramo, Jaume
Every day more people are using multifocal systems to correct presbyopia, as for example contact lenses or intraocular lenses. As a consequence, the necessity to do an appropriate characterization of their optical quality has increased. Due to this situation, the main purpose of this project has been to develop a new compact open-field double-pass system with asymmetric focus that characterizes objectively in vivo the optical quality of multifocal systems that are adapted or implanted in the eye. As a preliminary study, one diffractive and one refractive multifocal lens were implanted in a wet customized model-eye and characterized by this new set-up. Regarding the asymmetric focus of the set-up, a through-focus from +0.75 to -4.00D in steps of 0.25D was performed in the second pass for each tested lens,while the optical power of the first pass remained fixed. Results show that it is possible to distinguish, characterize the different foci of the measured multifocal intraocular lenses implanted in the model eye, and evaluate the optical quality of the system composed by the eye + the multifocal element. Therefore, it has been concluded that this new compact open-field double-pass system with asymmetric focus is suitable to evaluate the optical quality of multifocal systems adapted or implanted in the eye., Cada día más personas usan elementos ópticos multifocales para corregir la presbicia, por ejemplo una lente de contacto o una lente intraocular. En consecuencia, la necesidad de evaluar la calidad óptica del ojo con un elemento corrector multifocal ha adquirido una gran importancia. Dada esta situación, el principal objetivo de este proyecto ha sido desarrollar un nuevo sistema compacto basado en la técnica de doble-paso con enfoque asimétrico capaz de realizar una caracterización objetiva e “in vivo” de la calidad óptica del conjunto ojo-elemento óptico multifocal. En este estudio preliminar se han empleado dos lentes intraoculares multifocales, una difractiva y otra refractiva,implantadas en un ojo artificial. Al ser un sistema con enfoque asimétrico, se utilizó el segundo paso para realizar un barrido desde +0.75 a -4.00D en pasos de 0.25 D manteniendo el primer paso fijo. Los resultados han mostrado que es posible hallar y diferenciar los dos planos de enfoque, lejano y cercano, de las lentes intraoculares multifocales implantadas en el ojo artificial y evaluar la calidad óptica del conjunto ojoelemento multifocal. Por tanto, se ha demostrado la viabilidad de este nuevo sistema compacto de doble-paso con enfoque asimétrico para caracterizar la calidad óptica de un ojo con un elemento óptico multifocal., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Spherical subjective refraction with a novel 3D virtual reality based system

Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Texture evaluation of automotive coatings by means of a gonio-hyperspectral imaging system based on light-emitting diodes

  • Burgos Fernández, Francisco Javier
  • Pujol Ramo, Jaume
  • Perales Romero, Esther
  • Martínez Verdú, Francisco Miguel
  • Vilaseca Ricart, Meritxell
Sparkle and graininess are textural effects that appear as intrinsic spatial features of coatings containing goniochromatic pigments, whereas others such as mottling are undesired outcomes. In this study, we present new methods for the evaluation of sparkle, graininess and mottling of automotive coatings through images acquired with a novel gonio-hyperspectral imaging system based on light-emitting diodes with extended spectral sensitivity beyond the visible range (368–1309 nm). A novel analysis of sparkle that considered the amount of sparkling spots was used. Graininess was quantified through a novel statistical descriptor based on the energy descriptor computed from the histogram. A new index was proposed for an enhanced detection of mottling based on the analysis of striping, which was better observed and quantified in the infrared range. Spectral assessments showed a strong relationship with color and spectral reflectance for graininess and mottling. In conclusion, the results showed that these new spatial and spectral methods are a suitable, alternative and potential approach for the assessment of these textural features., Peer Reviewed, Postprint (published version)
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Spherical subjective refraction with a novel 3D virtual reality based system

  • Pujol Ramo, Jaume|||0000-0003-0811-9244
  • Ondategui-Parra, Juan Carlos
  • Badiella, Llorenç|||0000-0002-9653-7421
  • Otero, Carles
  • Vilaseca, Meritxell
  • Aldaba, Mikel
To conduct a clinical validation of a virtual reality-based experimental system that is able to assess the spherical subjective refraction simplifying the methodology of ocular refraction. For the agreement assessment, spherical refraction measurements were obtained from 104 eyes of 52 subjects using three different methods: subjectively with the experimental prototype (Subj.E) and the classical subjective refraction (Subj.C); and objectively with the WAM-5500 autorefractor (WAM). To evaluate precision (intra- and inter-observer variability) of each refractive tool independently, 26 eyes were measured in four occasions. With regard to agreement, the mean difference (±SD) for the spherical equivalent (M) between the new experimental subjective method (Subj.E) and the classical subjective refraction (Subj.C) was -0.034 D (±0.454 D). The corresponding 95% Limits of Agreement (LoA) were (-0.856 D, 0.924 D). In relation to precision, intra-observer mean difference for the M component was 0.034 ± 0.195 D for the Subj.C, 0.015 ± 0.177 D for the WAM and 0.072 ± 0.197 D for the Subj.E. Inter-observer variability showed worse precision values, although still clinically valid (below 0.25 D) in all instruments. The spherical equivalent obtained with the new experimental system was precise and in good agreement with the classical subjective routine. The algorithm implemented in this new system and its optical configuration has been shown to be a first valid step for spherical error correction in a semiautomated way.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Multispectral and colour imaging systems for the detection of small vertebrate fossils, a preliminary study

  • Delpueyo, Xana
  • Vilaseca, Meritxell
  • Furió, Marc|||0000-0002-4582-3268
  • Burgos-Fernández, Francisco J.
  • Pujol Ramo, Jaume|||0000-0003-0811-9244
The process of separating small vertebrate fossils from sediment is a monotonous exercise, usually carried out manually and mainly based on morphological features. The large amount of time and personnel required results in the high economic costs associated with this antiquated technique. In this study we test the potential of colour and multispectral imaging for the detection of small vertebrate fossils to facilitate their separation from sediment. This technique is based on the analysis of the spectral and fluorescence characteristics of fossils. Specifically, a multispectral system with a charge-coupled device (CCD) camera attached to a liquid crystal tunable filter and a digital colour camera was used in combination with daylight and ultraviolet light sources. The results show that the reflectance of bones, teeth and sediment are usually different at longer wavelengths, and that fluorescence rates also differ in the bluegreen region. Unfortunately, samples from different paleontological sites present different patterns, hindering the standardization of a method that discriminates microfossils from sediments. However, the combination of colour and multispectral imaging systems with recent advances in laser-stimulated fluorescence in fossils could constitute an optimal solution for an efficient sorting process of small vertebrate remains within geological samples.