Pasar al contenido principal

BIOFOTONICA Y TECNOLOGIA DE IMAGEN HIPERESPECTRAL APLICADAS A LA SALUD VISUAL Y A LA INVESTIGACION DEL CANCER DE PIEL

DPI2014-56850-R

•
Nombre agencia financiadora Ministerio de Economía y Competitividad
Acrónimo agencia financiadora MINECO
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2014
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Unidad de gestión Secretaría de Estado de Educación, Formación Profesional y Universidades
Centro beneficiario UNIVERSITAT POLITECNICA DE CATALUNYA
Identificador persistente http://dx.doi.org/10.13039/501100003329

Resultados relacionados

Resultados totales (Incluyendo duplicados): 13
Encontrada(s) 1 página(s)

RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Texture Evaluation of Automotive Coatings by Means of a Gonio-Hyperspectral Imaging System Based on Light-Emitting Diodes

  • Burgos Fernández, Francisco Javier
  • Pujol Ramo, Jaume
  • Perales, Esther
  • Martínez-Verdú, Francisco M.
  • Vilaseca Ricart, Meritxell
  • Perales, Esther|||/items/3c441acb-4c61-4b30-b94e-907ed26edd23
  • Martínez-Verdú, Francisco M.|||/items/1b2eb36f-ce01-47d8-b72f-b852349c01a7
Sparkle and graininess are textural effects that appear as intrinsic spatial features of coatings containing goniochromatic pigments, whereas others such as mottling are undesired outcomes. In this study, we present new methods for the evaluation of sparkle, graininess and mottling of automotive coatings through images acquired with a novel gonio-hyperspectral imaging system based on light-emitting diodes with extended spectral sensitivity beyond the visible range (368–1309 nm). A novel analysis of sparkle that considered the amount of sparkling spots was used. Graininess was quantified through a novel statistical descriptor based on the energy descriptor computed from the histogram. A new index was proposed for an enhanced detection of mottling based on the analysis of striping, which was better observed and quantified in the infrared range. Spectral assessments showed a strong relationship with color and spectral reflectance for graininess and mottling. In conclusion, the results showed that these new spatial and spectral methods are a suitable, alternative and potential approach for the assessment of these textural features.
UPCommons. Portal del coneixement obert de la UPC
Publicación Capítulo o parte de un libro (BookPart)

Visible and extended near-infrared multispectral imaging for skin cancer diagnosis

  • Rey Barroso, Laura|||0000-0002-6305-0609
  • Burgos Fernández, Francisco Javier|||0000-0002-3749-6850
  • Delpueyo, Xana
  • Ares Rodríguez, Miguel|||0000-0001-5710-823X
  • Royo Royo, Santiago|||0000-0003-0136-8301
  • Malvehy Guilera, Josep
  • Puig, Susana
  • Vilaseca Ricart, Meritxell|||0000-0001-8166-1617
With the goal of diagnosing skin cancer in an early and noninvasive way, an extended near infrared multispectral imaging system based on an InGaAs sensor with sensitivity from 995 nm to 1613 nm was built to evaluate deeper skin layers thanks to the higher penetration of photons at these wavelengths. The outcomes of this device were combined with those of a previously developed multispectral system that works in the visible and near infrared range (414 nm–995 nm). Both provide spectral and spatial information from skin lesions. A classification method to discriminate between melanomas and nevi was developed based on the analysis of first-order statistics descriptors, principal component analysis, and support vector machine tools. The system provided a sensitivity of 78.6% and a specificity of 84.6%, the latter one being improved with respect to that offered by silicon sensors., This research was supported by the Spanish Ministry of Economy and Competitiveness under the grant DPI2014-56850-R, DPI2017-89414-R, and by the European Union through the project DIAGNOPTICS ‘diagnosis of skin cancer using optics’ (ICT PSP seventh call for proposals 2013)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Binocular open-view system to perform estimations of aberrations and scattering in the human eye

  • García Guerra, Carlos Enrique|||0000-0001-7013-9938
  • Aldaba Arévalo, Mikel|||0000-0001-5835-4395
  • Pujol Ramo, Jaume|||0000-0003-0811-9244
  • Arjona Carbonell, Mª Montserrat|||0000-0001-9040-8410
We present a system that integrates a double-pass (DP) instrument and a Hartmann-Shack (HS) wavefront sensor to provide information not only on aberrations, but also on scattering occurring in the human eye. A binocular open-view design permits evaluations in normal viewing conditions. Furthermore, the system is able to compensate for both spherical and astigmatic refractive errors during measurements by using devices with configurable optical power. The DP and HS techniques provide comparable data after estimating wavefront slopes with respect to intersections of an ideal grid and compensating for residual errors provoked by optical defects of the measuring system. Once comparable data is obtained, it is possible to use this combined manner of assessment to provide information on scattering. Measurements in an artificial eye suggest that the characteristics of the ocular fundus may induce deviations of DP with respect to HS data. These differences were quantified in terms of the modulation transfer function in young healthy eyes measured in infrared light to demonstrate the potential use of the system in visual optics studies.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Double-pass technique and compensation-comparison method in eyes with cataract

  • Martínez Roda, Juan Antonio|||0000-0003-0222-7164
  • Vilaseca Ricart, Meritxell|||0000-0001-8166-1617
  • Ondategui Parra, Juan Carlos|||0000-0001-8090-6731
  • Almudí Cortés, Lorena
  • Asaad Ammaar, Mouafk
  • Mateos Pena, Lorena
  • Arjona Carbonell, Mª Montserrat|||0000-0001-9040-8410
  • Pujol Ramo, Jaume|||0000-0003-0811-9244
PURPOSE To clinically assess the objective scatter index (OSI) obtained from double-pass images and the log(s) parameter measured with the direct compensation-comparison psychophysical technique in eyes with cataract. SETTING Ophthalmology Service, Terrassa Hospital, Barcelona, Spain. DESIGN Prospective observational case series. METHODS The analysis comprised eyes diagnosed with nuclear, cortical, or posterior subcapsular cataracts and healthy eyes (control group). Patient examinations included assessment of the manifest subjective refraction, corrected distance visual acuity, contrast sensitivity, and cataract grade using the Lens Opacities Classification System III (LOCS III) score. The protocol also included the straylight (log[s]) measured by the C-Quant device, measurement of the objective optical quality (Strehl ratio and modulation transfer function cutoff frequency), and the OSI (HD Analyzer). RESULTS Significant correlations with LOCS III classification were found in terms of log(s) and OSI, although they were slightly stronger with OSI for all cataract types, which could be attributable to higher-order aberrations. The OSI and log(s) shared approximately 44% of the scattering estimation and to coincide on the visual function decline with scattering for the 3 cataract types evaluated. Limits to discriminate between healthy and cataractous eyes and sensitivity and specificity values were 1.15 (sensitivity 91%, specificity 100%) for log(s) and 1.18 (sensitivity 89%, specificity 100%) for OSI (P < .05). CONCLUSIONS Both instruments provide complementary information to diagnose cataracts and follow patients. Although backscattered light from deeper retinal layers can have an effect on OSI, the double-pass image provides information to grade different types of cataract when assessing cataractous eyes for treatment.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

An automated and objective cover test to measure heterophoria

UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Does the Badal optometer stimulate accommodation accurately?

UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Texture evaluation of automotive coatings by means of a gonio-hyperspectral imaging system based on light-emitting diodes

  • Burgos Fernández, Francisco Javier|||0000-0002-3749-6850
  • Pujol Ramo, Jaume|||0000-0003-0811-9244
  • Perales Romero, Esther
  • Martínez Verdú, Francisco Miguel
  • Vilaseca Ricart, Meritxell|||0000-0001-8166-1617
Sparkle and graininess are textural effects that appear as intrinsic spatial features of coatings containing goniochromatic pigments, whereas others such as mottling are undesired outcomes. In this study, we present new methods for the evaluation of sparkle, graininess and mottling of automotive coatings through images acquired with a novel gonio-hyperspectral imaging system based on light-emitting diodes with extended spectral sensitivity beyond the visible range (368–1309 nm). A novel analysis of sparkle that considered the amount of sparkling spots was used. Graininess was quantified through a novel statistical descriptor based on the energy descriptor computed from the histogram. A new index was proposed for an enhanced detection of mottling based on the analysis of striping, which was better observed and quantified in the infrared range. Spectral assessments showed a strong relationship with color and spectral reflectance for graininess and mottling. In conclusion, the results showed that these new spatial and spectral methods are a suitable, alternative and potential approach for the assessment of these textural features., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Does the Badal optometer stimulate accommodation accurately?

Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Texture evaluation of automotive coatings by means of a gonio-hyperspectral imaging system based on light-emitting diodes

  • Burgos Fernández, Francisco Javier
  • Pujol Ramo, Jaume
  • Perales Romero, Esther
  • Martínez Verdú, Francisco Miguel
  • Vilaseca Ricart, Meritxell
Sparkle and graininess are textural effects that appear as intrinsic spatial features of coatings containing goniochromatic pigments, whereas others such as mottling are undesired outcomes. In this study, we present new methods for the evaluation of sparkle, graininess and mottling of automotive coatings through images acquired with a novel gonio-hyperspectral imaging system based on light-emitting diodes with extended spectral sensitivity beyond the visible range (368–1309 nm). A novel analysis of sparkle that considered the amount of sparkling spots was used. Graininess was quantified through a novel statistical descriptor based on the energy descriptor computed from the histogram. A new index was proposed for an enhanced detection of mottling based on the analysis of striping, which was better observed and quantified in the infrared range. Spectral assessments showed a strong relationship with color and spectral reflectance for graininess and mottling. In conclusion, the results showed that these new spatial and spectral methods are a suitable, alternative and potential approach for the assessment of these textural features., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Binocular open-view system to perform estimations of aberrations and scattering in the human eye

  • García Guerra, Carlos Enrique
  • Aldaba Arévalo, Mikel
  • Pujol Ramo, Jaume
  • Arjona Carbonell, Mª Montserrat
We present a system that integrates a double-pass (DP) instrument and a Hartmann-Shack (HS) wavefront sensor to provide information not only on aberrations, but also on scattering occurring in the human eye. A binocular open-view design permits evaluations in normal viewing conditions. Furthermore, the system is able to compensate for both spherical and astigmatic refractive errors during measurements by using devices with configurable optical power. The DP and HS techniques provide comparable data after estimating wavefront slopes with respect to intersections of an ideal grid and compensating for residual errors provoked by optical defects of the measuring system. Once comparable data is obtained, it is possible to use this combined manner of assessment to provide information on scattering. Measurements in an artificial eye suggest that the characteristics of the ocular fundus may induce deviations of DP with respect to HS data. These differences were quantified in terms of the modulation transfer function in young healthy eyes measured in infrared light to demonstrate the potential use of the system in visual optics studies., Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

An automated and objective cover test to measure heterophoria

Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Double-pass technique and compensation-comparison method in eyes with cataract

  • Martínez Roda, Juan Antonio
  • Vilaseca Ricart, Meritxell
  • Ondategui Parra, Juan Carlos
  • Almudí Cortés, Lorena
  • Asaad Ammaar, Mouafk
  • Mateos Pena, Lorena
  • Arjona Carbonell, Mª Montserrat
  • Pujol Ramo, Jaume
PURPOSE To clinically assess the objective scatter index (OSI) obtained from double-pass images and the log(s) parameter measured with the direct compensation-comparison psychophysical technique in eyes with cataract. SETTING Ophthalmology Service, Terrassa Hospital, Barcelona, Spain. DESIGN Prospective observational case series. METHODS The analysis comprised eyes diagnosed with nuclear, cortical, or posterior subcapsular cataracts and healthy eyes (control group). Patient examinations included assessment of the manifest subjective refraction, corrected distance visual acuity, contrast sensitivity, and cataract grade using the Lens Opacities Classification System III (LOCS III) score. The protocol also included the straylight (log[s]) measured by the C-Quant device, measurement of the objective optical quality (Strehl ratio and modulation transfer function cutoff frequency), and the OSI (HD Analyzer). RESULTS Significant correlations with LOCS III classification were found in terms of log(s) and OSI, although they were slightly stronger with OSI for all cataract types, which could be attributable to higher-order aberrations. The OSI and log(s) shared approximately 44% of the scattering estimation and to coincide on the visual function decline with scattering for the 3 cataract types evaluated. Limits to discriminate between healthy and cataractous eyes and sensitivity and specificity values were 1.15 (sensitivity 91%, specificity 100%) for log(s) and 1.18 (sensitivity 89%, specificity 100%) for OSI (P < .05). CONCLUSIONS Both instruments provide complementary information to diagnose cataracts and follow patients. Although backscattered light from deeper retinal layers can have an effect on OSI, the double-pass image provides information to grade different types of cataract when assessing cataractous eyes for treatment., Preprint
Recercat. Dipósit de la Recerca de Catalunya
Publicación

Visible and extended near-infrared multispectral imaging for skin cancer diagnosis

  • Rey Barroso, Laura
  • Burgos Fernández, Francisco Javier
  • Delpueyo, Xana
  • Ares Rodríguez, Miguel
  • Royo Royo, Santiago
  • Malvehy Guilera, Josep
  • Puig, Susana
  • Vilaseca Ricart, Meritxell
With the goal of diagnosing skin cancer in an early and noninvasive way, an extended near infrared multispectral imaging system based on an InGaAs sensor with sensitivity from 995 nm to 1613 nm was built to evaluate deeper skin layers thanks to the higher penetration of photons at these wavelengths. The outcomes of this device were combined with those of a previously developed multispectral system that works in the visible and near infrared range (414 nm–995 nm). Both provide spectral and spatial information from skin lesions. A classification method to discriminate between melanomas and nevi was developed based on the analysis of first-order statistics descriptors, principal component analysis, and support vector machine tools. The system provided a sensitivity of 78.6% and a specificity of 84.6%, the latter one being improved with respect to that offered by silicon sensors., This research was supported by the Spanish Ministry of Economy and Competitiveness under the grant DPI2014-56850-R, DPI2017-89414-R, and by the European Union through the project DIAGNOPTICS ‘diagnosis of skin cancer using optics’ (ICT PSP seventh call for proposals 2013)., Peer Reviewed, Postprint (published version)