Pasar al contenido principal

INTELLIGENT IN-VIVO ENDOSCOPIC DIAGNOSIS AND INTERVENTION SUPPORT SYSTEMS

DPI2015-65286-R

•
Nombre agencia financiadora Ministerio de Economía y Competitividad
Acrónimo agencia financiadora MINECO
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2015
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Unidad de gestión Dirección General de Investigación Científica y Técnica
Centro beneficiario CENTRO DE VISION POR COMPUTADOR
Identificador persistente http://dx.doi.org/10.13039/501100003329

Resultados relacionados

Resultados totales (Incluyendo duplicados): 11
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Exploring the clinical potential of an automatic colonic polyp detection method based on the creation of energy maps

  • Fernández-Esparrach, Gloria|||0000-0002-3378-3940
  • Bernal del Nozal, Jorge|||0000-0001-8493-9514
  • Lopez-Ceron, Maria|||0000-0002-7968-9204
  • Córdova, Henry|||0000-0002-6636-6764
  • Sánchez Montes, Cristina|||0000-0002-9692-9521
  • Rodríguez De Miguel, Cristina|||0000-0002-5576-0854
  • Sánchez, F. Javier|||0000-0002-9364-3122
Background and aims: Polyp miss-rate is a drawback of colonoscopy that increases significantly for small polyps. We explored the efficacy of an automatic computer-vision method for polyp detection. Methods: Our method relies on a model that defines polyp boundaries as valleys of image intensity. Valley information is integrated into energy maps that represent the likelihood of the presence of a polyp. Results: In 24 videos containing polyps from routine colonoscopies, all polyps were detected in at least one frame. The mean of the maximum values on the energy map was higher for frames with polyps than without (P<0.001). Performance improved in high quality frames (AUC=0.79 [95%CI 0.70-0.87] vs. 0.75 [95%CI 0.66-0.83]). With 3.75 set as the maximum threshold value, sensitivity and specificity for the detection of polyps were 70.4% (95%CI 60.3%-80.8%) and 72.4% (95%CI 61.6%-84.6%), respectively. Conclusion: Energy maps performed well for colonic polyp detection, indicating their potential applicability in clinical practice.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Bright spot regions segmentation and classification for specular highlights detection in colonoscopy videos

  • Sánchez, F. Javier|||0000-0002-9364-3122
  • Bernal del Nozal, Jorge|||0000-0001-8493-9514
  • Sánchez Montes, Cristina|||0000-0002-9692-9521
  • Rodríguez De Miguel, Cristina|||0000-0002-5576-0854
  • Fernández-Esparrach, Gloria|||0000-0002-3378-3940
A novel specular highlights detection method in colonoscopy videos is presented. The method is based on a model of appearance defining specular highlights as bright spots which are highly contrasted with respect to adjacent regions. Our approach proposes two stages: segmentation and then classification of bright spot regions. The former defines a set of candidate regions obtained through a region growing process with local maxima as initial region seeds. This process creates a tree structure which keeps track, at each growing iteration, of the region frontier contrast; final regions provided depend on restrictions over contrast value. Non-specular regions are filtered through a classification stage performed by a linear SVM classifier using model-based features from each region. We introduce a new validation database with more than 25, 000 regions along with their corresponding pixel-wise annotations. We perform a comparative study against other approaches. Results show that our method is superior to other approaches, with our segmented regions being closer to actual specular regions in the image. Finally, we also present how our methodology can also be used to obtain an accurate prediction of polyp histology.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

GTCreator, a flexible annotation tool for image-based datasets

  • Bernal del Nozal, Jorge|||0000-0001-8493-9514
  • Histace, Aymeric|||0000-0002-3029-4412
  • Masana, Marc|||0000-0003-3254-3096
  • Angermann, Quentin
  • Sánchez Montes, Cristina|||0000-0002-9692-9521
  • Rodríguez De Miguel, Cristina|||0000-0002-5576-0854
  • Hammami, Maroua
  • García-Rodríguez, Ana
  • Córdova, Henry|||0000-0002-6636-6764
  • Romain, Olivier
  • Fernández-Esparrach, Gloria|||0000-0002-3378-3940
  • Dray, Xavier
  • Sánchez, F. Javier|||0000-0002-9364-3122
Purpose:: Methodology evaluation for decision support systems for health is a time-consuming task. To assess performance of polyp detection methods in colonoscopy videos, clinicians have to deal with the annotation of thousands of images. Current existing tools could be improved in terms of flexibility and ease of use. Methods:: We introduce GTCreator, a flexible annotation tool for providing image and text annotations to image-based datasets. It keeps the main basic functionalities of other similar tools while extending other capabilities such as allowing multiple annotators to work simultaneously on the same task or enhanced dataset browsing and easy annotation transfer aiming to speed up annotation processes in large datasets. Results:: The comparison with other similar tools shows that GTCreator allows to obtain fast and precise annotation of image datasets, being the only one which offers full annotation editing and browsing capabilites. Conclusion:: Our proposed annotation tool has been proven to be efficient for large image dataset annotation, as well as showing potential of use in other stages of method evaluation such as experimental setup or results analysis.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Comparative Validation of Polyp Detection Methods in Video Colonoscopy, Results from the MICCAI 2015 Endoscopic Vision Challenge

  • Bernal del Nozal, Jorge|||0000-0001-8493-9514
  • Tajkbaksh, Nima
  • Sánchez, F. Javier|||0000-0002-9364-3122
  • Matuszewski, Bogdan J.
  • Chen, Hao
  • Yu, Lequan
  • Angermann, Quentin
  • Romain, Olivier
  • Rustad, Bjørn
  • Balasingham, Ilangko
  • Pogorelov, Konstantin
  • Choi, Sungbin
  • Debard, Quentin
  • Maier-Hein, Lena
  • Speidel, Stefanie
  • Stoyanov, Danail
  • Brandao, Patrick
  • Córdova, Henry|||0000-0002-6636-6764
  • Sánchez Montes, Cristina|||0000-0002-9692-9521
  • Gurudu, Suryakanth R.
  • Fernández-Esparrach, Gloria|||0000-0002-3378-3940
  • Dray, Xavier
  • Liang, Jianming
  • Histace, Aymeric|||0000-0002-3029-4412
Colonoscopy is the gold standard for colon cancer screening though some polyps are still missed, thus preventing early disease detection and treatment. Several computational systems have been proposed to assist polyp detection during colonoscopy but so far without consistent evaluation. The lack of publicly available annotated databases has made it difficult to compare methods and to assess if they achieve performance levels acceptable for clinical use. The Automatic Polyp Detection sub-challenge, conducted as part of the Endoscopic Vision Challenge (http://endovis.grand-challenge.org) at the international conference on Medical Image Computing and Computer Assisted Intervention (MICCAI) in 2015, was an effort to address this need. In this paper, we report the results of this comparative evaluation of polyp detection methods, as well as describe additional experiments to further explore differences between methods. We define performance metrics and provide evaluation databases that allow comparison of multiple methodologies. Results show that convolutional neural networks are the state of the art. Nevertheless, it is also demonstrated that combining different methodologies can lead to an improved overall performance.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Computer-aided prediction of polyp histology on white light colonoscopy using surface pattern analysis

  • Sánchez Montes, Cristina|||0000-0002-9692-9521
  • Sánchez, F. Javier|||0000-0002-9364-3122
  • Bernal del Nozal, Jorge|||0000-0001-8493-9514
  • Córdova, Henry|||0000-0002-6636-6764
  • Lopez-Ceron, Maria|||0000-0002-7968-9204
  • Cuatrecasas, Miriam|||0000-0003-3063-0110
  • Rodríguez De Miguel, Cristina|||0000-0002-5576-0854
  • García-Rodríguez, Ana
  • Garcés-Durán, Rodrigo
  • Pellisé, Maria|||0000-0001-9739-4998
  • Llach, Josep
  • Fernández-Esparrach, Gloria|||0000-0002-3378-3940
Background This study aimed to evaluate a new computational histology prediction system based on colorectal polyp textural surface patterns using high definition white light images. Methods Textural elements (textons) were characterized according to their contrast with respect to the surface, shape, and number of bifurcations, assuming that dysplastic polyps are associated with highly contrasted, large tubular patterns with some degree of bifurcation. Computer-aided diagnosis (CAD) was compared with pathological diagnosis and the diagnosis made by endoscopists using Kudo and Narrow-Band Imaging International Colorectal Endoscopic classifications. Results Images of 225 polyps were evaluated (142 dysplastic and 83 nondysplastic). The CAD system correctly classified 205 polyps (91.1 %): 131/142 dysplastic (92.3 %) and 74/83 (89.2 %) nondysplastic. For the subgroup of 100 diminutive polyps (≤ 5 mm), CAD correctly classified 87 polyps (87.0 %): 43/50 (86.0 %) dysplastic and 44/50 (88.0 %) nondysplastic. There were no statistically significant differences in polyp histology prediction between the CAD system and endoscopist assessment. Conclusion A computer vision system based on the characterization of the polyp surface in white light accurately predicted colorectal polyp histology.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Influence of fiber connectivity in simulations of cardiac biomechanics

  • Gil-Tapetado, Diego
  • Arís, Ruth
  • Borrás, A.
  • Ramírez, E.
  • Sebastian, Rafael
  • Vázquez, Mariano
Purpose: Personalized computational simulations of the heart could open up new improved approaches to diagnosis and surgery assistance systems. While it is fully recognized that myocardial fiber orientation is central for the construction of realistic computational models of cardiac electromechanics, the role of its overall architecture and connectivity remains unclear. Morphological studies show that the distribution of cardiac muscular fibers at the basal ring connects epicardium and endocardium. However, computational models simplify their distribution and disregard the basal loop. This work explores the influence in computational simulations of fiber distribution at different short-axis cuts. Methods: We have used a highly parallelized computational solver to test different fiber models of ventricular muscular connectivity. We have considered two rule-based mathematical models and an own-designed method preserving basal connectivity as observed in experimental data. Simulated cardiac functional scores (rotation, torsion and longitudinal shortening) were compared to experimental healthy ranges using generalized models (rotation) and Mahalanobis distances (shortening, torsion). Results: The probability of rotation was significantly lower for ruled-based models [95% CI (0.13, 0.20)] in comparison with experimental data [95% CI (0.23, 0.31)]. The Mahalanobis distance for experimental data was in the edge of the region enclosing 99% of the healthy population. Conclusions: Cardiac electromechanical simulations of the heart with fibers extracted from experimental data produce functional scores closer to healthy ranges than rule-based models disregarding architecture connectivity., This work was funded by Spanish Projects DPI2015- 430 65286-R, 2017-SGR-1624, the CERCA Programme, the Serra Hunter Programme and the grant BES-2016-078042., Peer reviewed
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

A Benchmark for endoluminal scene segmentation of colonoscopy images

  • Vázquez Bermúdez, David|||0000-0002-2845-8158
  • Bernal del Nozal, Jorge|||0000-0001-8493-9514
  • Sánchez, F. Javier|||0000-0002-9364-3122
  • Fernández-Esparrach, Gloria|||0000-0002-3378-3940
  • López Peña, Antonio M.|||0000-0002-6979-5783
  • Romero, Adriana
  • Drozdzal, Michal
  • Courville, Aaron
Colorectal cancer (CRC) is the third cause of cancer death worldwide. Currently, the standard approach to reduce CRC-related mortality is to perform regular screening in search for polyps and colonoscopy is the screening tool of choice. The main limitations of this screening procedure are polyp miss rate and the inability to perform visual assessment of polyp malignancy. These drawbacks can be reduced by designing decision support systems (DSS) aiming to help clinicians in the different stages of the procedure by providing endoluminal scene segmentation. Thus, in this paper, we introduce an extended benchmark of colonoscopy image segmentation, with the hope of establishing a new strong benchmark for colonoscopy image analysis research. The proposed dataset consists of 4 relevant classes to inspect the endoluminal scene, targeting different clinical needs. Together with the dataset and taking advantage of advances in semantic segmentation literature, we provide new baselines by training standard fully convolutional networks (FCNs). We perform a comparative study to show that FCNs significantly outperform, without any further postprocessing, prior results in endoluminal scene segmentation, especially with respect to polyp segmentation and localization.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

BronchoX, bronchoscopy exploration software for biopsy intervention planning

  • Ramírez, Esmitt|||0000-0001-7573-631X
  • Sánchez Ramos, Carles|||0000-0003-3435-9882
  • Borràs, Agnés|||0000-0002-7747-9924
  • Diez-Ferrer, Marta|||0000-0002-0207-8157
  • Rosell Gratacos, Antoni|||0000-0003-0877-7191
  • Gil, Debora|||0000-0002-2770-4767
Virtual bronchoscopy (VB) is a non-invasive exploration tool for intervention planning and navigation of possible pulmonary lesions (PLs). A VB software involves the location of a PL and the calculation of a route, starting from the trachea, to reach it. The selection of a VB software might be a complex process, and there is no consensus in the community of medical software developers in which is the best-suited system to use or framework to choose. The authors present Bronchoscopy Exploration (BronchoX), a VB software to plan biopsy interventions that generate physician-readable instructions to reach the PLs. The authors' solution is open source, multiplatform, and extensible for future functionalities, designed by their multidisciplinary research and development group. BronchoX is a compound of different algorithms for segmentation, visualisation, and navigation of the respiratory tract. Performed results are a focus on the test the effectiveness of their proposal as an exploration software, also to measure its accuracy as a guiding system to reach PLs. Then, 40 different virtual planning paths were created to guide physicians until distal bronchioles. These results provide a functional software for BronchoX and demonstrate how following simple instructions is possible to reach distal lesions from the trachea.
Dipòsit Digital de Documents de la UAB
Publicación Capítulo o parte de un libro (BookPart)

Image-Based Bronchial Anatomy Codification for Biopsy Guiding in Video Bronchoscopy

  • Ramírez, Esmitt|||0000-0001-7573-631X
  • Sánchez Ramos, Carles|||0000-0003-3435-9882
  • Borràs, Agnés|||0000-0002-7747-9924
  • Diez-Ferrer, Marta|||0000-0002-0207-8157
  • Rosell Gratacos, Antoni|||0000-0003-0877-7191
  • Gil, Debora|||0000-0002-2770-4767
Bronchoscopy examinations allow biopsy of pulmonary nodules with minimum risk for the patient. Even for experienced bronchoscopists, it is difficult to guide the bronchoscope to most distal lesions and obtain an accurate diagnosis. This paper presents an image-based codification of the bronchial anatomy for bronchoscopy biopsy guiding. The 3D anatomy of each patient is codified as a binary tree with nodes representing bronchial levels and edges labeled using their position on images projecting the 3D anatomy from a set of branching points. The paths from the root to leaves provide a codification of navigation routes with spatially consistent labels according to the anatomy observes in video bronchoscopy explorations. We evaluate our labeling approach as a guiding system in terms of the number of bronchial levels correctly codified, also in the number of labels-based instructions correctly supplied, using generalized mixed models and computer-generated data. Results obtained for three independent observers prove the consistency and reproducibility of our guiding system. We trust that our codification based on viewer's projection might be used as a foundation for the navigation process in Virtual Bronchoscopy systems.
Dipòsit Digital de Documents de la UAB
Publicación Capítulo o parte de un libro (BookPart)

Back to Front Architecture for Diagnosis as a Service

  • Sánchez Ramos, Carles|||0000-0003-3435-9882
  • Viñas, Miguel-Angel
  • Atens, Coen Jacobus
  • Borràs, Agnés|||0000-0002-7747-9924
  • Gil, Debora|||0000-0002-2770-4767
Software as a Service (SaaS) is a cloud computing model in which a provider hosts applications in a server that customers use via internet. Since SaaS does not require to install applications on customers' own computers, it allows the use by multiple users of highly specialized software without extra expenses for hardware acquisition or licensing. A SaaS tailored for clinical needs not only would alleviate licensing costs, but also would facilitate easy access to new methods for diagnosis assistance. This paper presents a SaaS client-server architecture for Diagnosis as a Service (DaaS). The server is based on docker technology in order to allow execution of softwares implemented in different languages with the highest portability and scalability. The client is a content management system allowing the design of websites with multimedia content and interactive visualization of results allowing user editing. We explain a usage case that uses our DaaS as crowdsourcing platform in a multicentric pilot study carried out to evaluate the clinical benefits of a software for assessment of central airway obstruction.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Time to match, when do homologous chromosomes become closer?

  • Solé Canal, Mireia|||0000-0002-6054-0071
  • Blanco, Joan|||0000-0003-0647-3856
  • Gil, Debora|||0000-0002-2770-4767
  • Valero, Oliver|||0000-0003-0014-9916
  • Cárdenas, Bryan|||0000-0002-6752-7355
  • Fonseka, G.
  • Anton, Ester|||0000-0002-8914-2667
  • Pascual Bascuñana, Álvaro|||0000-0002-9821-5442
  • Frodsham, R.
  • Vidal, Francesca|||0000-0002-0985-7348
  • Sarrate Navas, Zaida|||0000-0001-9677-1376
In most eukaryotes, pairing of homologous chromosomes is an essential feature of meiosis that ensures homologous recombination and segregation. However, when the pairing process begins, it is still under investigation. Contrasting data exists in Mus musculus, since both leptotene DSB-dependent and preleptotene DSB-independent mechanisms have been described. To unravel this contention, we examined homologous pairing in pre-meiotic and meiotic Mus musculus cells using a three-dimensional fluorescence in situ hybridization-based protocol, which enables the analysis of the entire karyotype using DNA painting probes. Our data establishes in an unambiguously manner that 73.83% of homologous chromosomes are already paired at premeiotic stages (spermatogonia-early preleptotene spermatocytes). The percentage of paired homologous chromosomes increases to 84.60% at mid-preleptotene-zygotene stage, reaching 100% at pachytene stage. Importantly, our results demonstrate a high percentage of homologous pairing observed before the onset of meiosis; this pairing does not occur randomly, as the percentage was higher than that observed in somatic cells (19.47%) and between nonhomologous chromosomes (41.1%). Finally, we have also observed that premeiotic homologous pairing is asynchronous and independent of the chromosome size, GC content, or presence of NOR regions.