Pasar al contenido principal

VALIDACION CLINICA DEL PRIMER SISTEMA IN-VIVO DE PREDICCION HISTOLOGICA AUTOMATICA DE LOS POLIPOS DE COLON INTEGRANDO LA VISION DEL ENDOSCOPISTA CON LA VISION POR COMPUTADOR (HISINVIA)

PI17/00894

•
Nombre agencia financiadora Instituto de Salud Carlos III
Acrónimo agencia financiadora ISCIII
Programa Programa Estatal de Fomento de la Investigación Científica y Técnica de Excelencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de Investigación en Salud
Año convocatoria 2017
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario INSTITUTO DE INVESTIGACIONES BIOMEDICAS AUGUST PI I SUNYER (IDIBAPS)
Centro realización INSTITUTO DE INVESTIGACIONES BIOMEDICAS AUGUST PI I SUNYER (IDIBAPS)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

GTCreator, a flexible annotation tool for image-based datasets

  • Bernal del Nozal, Jorge|||0000-0001-8493-9514
  • Histace, Aymeric|||0000-0002-3029-4412
  • Masana, Marc|||0000-0003-3254-3096
  • Angermann, Quentin
  • Sánchez Montes, Cristina|||0000-0002-9692-9521
  • Rodríguez De Miguel, Cristina|||0000-0002-5576-0854
  • Hammami, Maroua
  • García-Rodríguez, Ana
  • Córdova, Henry|||0000-0002-6636-6764
  • Romain, Olivier
  • Fernández-Esparrach, Gloria|||0000-0002-3378-3940
  • Dray, Xavier
  • Sánchez, F. Javier|||0000-0002-9364-3122
Purpose:: Methodology evaluation for decision support systems for health is a time-consuming task. To assess performance of polyp detection methods in colonoscopy videos, clinicians have to deal with the annotation of thousands of images. Current existing tools could be improved in terms of flexibility and ease of use. Methods:: We introduce GTCreator, a flexible annotation tool for providing image and text annotations to image-based datasets. It keeps the main basic functionalities of other similar tools while extending other capabilities such as allowing multiple annotators to work simultaneously on the same task or enhanced dataset browsing and easy annotation transfer aiming to speed up annotation processes in large datasets. Results:: The comparison with other similar tools shows that GTCreator allows to obtain fast and precise annotation of image datasets, being the only one which offers full annotation editing and browsing capabilites. Conclusion:: Our proposed annotation tool has been proven to be efficient for large image dataset annotation, as well as showing potential of use in other stages of method evaluation such as experimental setup or results analysis.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Computer-aided prediction of polyp histology on white light colonoscopy using surface pattern analysis

  • Sánchez Montes, Cristina|||0000-0002-9692-9521
  • Sánchez, F. Javier|||0000-0002-9364-3122
  • Bernal del Nozal, Jorge|||0000-0001-8493-9514
  • Córdova, Henry|||0000-0002-6636-6764
  • Lopez-Ceron, Maria|||0000-0002-7968-9204
  • Cuatrecasas, Miriam|||0000-0003-3063-0110
  • Rodríguez De Miguel, Cristina|||0000-0002-5576-0854
  • García-Rodríguez, Ana
  • Garcés-Durán, Rodrigo
  • Pellisé, Maria|||0000-0001-9739-4998
  • Llach, Josep
  • Fernández-Esparrach, Gloria|||0000-0002-3378-3940
Background This study aimed to evaluate a new computational histology prediction system based on colorectal polyp textural surface patterns using high definition white light images. Methods Textural elements (textons) were characterized according to their contrast with respect to the surface, shape, and number of bifurcations, assuming that dysplastic polyps are associated with highly contrasted, large tubular patterns with some degree of bifurcation. Computer-aided diagnosis (CAD) was compared with pathological diagnosis and the diagnosis made by endoscopists using Kudo and Narrow-Band Imaging International Colorectal Endoscopic classifications. Results Images of 225 polyps were evaluated (142 dysplastic and 83 nondysplastic). The CAD system correctly classified 205 polyps (91.1 %): 131/142 dysplastic (92.3 %) and 74/83 (89.2 %) nondysplastic. For the subgroup of 100 diminutive polyps (≤ 5 mm), CAD correctly classified 87 polyps (87.0 %): 43/50 (86.0 %) dysplastic and 44/50 (88.0 %) nondysplastic. There were no statistically significant differences in polyp histology prediction between the CAD system and endoscopist assessment. Conclusion A computer vision system based on the characterization of the polyp surface in white light accurately predicted colorectal polyp histology.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

In vivo computer-aided diagnosis of colorectal polyps using white light endoscopy

  • García-Rodríguez, Ana
  • Tudela, Yael
  • Córdova, Henry|||0000-0002-6636-6764
  • Carballal, Sabela
  • Ordás, Ingrid|||0000-0001-7632-0340
  • Moreira, Leticia|||0000-0002-4518-8591
  • Vaquero, Eva|||0000-0003-0098-5295
  • Ortiz, Oswaldo
  • Rivero, Liseth
  • Sánchez, F. Javier|||0000-0002-9364-3122
  • Cuatrecasas, Miriam|||0000-0003-3063-0110
  • Pellisé, Maria|||0000-0001-9739-4998
  • Bernal del Nozal, Jorge|||0000-0001-8493-9514
  • Fernández-Esparrach, Gloria|||0000-0002-3378-3940
Background and study aims Artificial intelligence is currently able to accurately predict the histology of colorectal polyps. However, systems developed to date use complex optical technologies and have not been tested in vivo. The objective of this study was to evaluate the efficacy of a new deep learning-based optical diagnosis system, ATENEA, in a real clinical setting using only high-definition white light endoscopy (WLE) and to compare its performance with endoscopists. Methods ATENEA was prospectively tested in real life on consecutive polyps detected in colorectal cancer screening colonoscopies at Hospital Clínic. No images were discarded, and only WLE was used. The in vivo ATENEA's prediction (adenoma vs non-adenoma) was compared with the prediction of four staff endoscopists without specific training in optical diagnosis for the study purposes. Endoscopists were blind to the ATENEA output. Histology was the gold standard. Results Ninety polyps (median size: 5 mm, range: 2-25) from 31 patients were included of which 69 (76.7 %) were adenomas. ATENEA correctly predicted the histology in 63 of 69 (91.3 %, 95 % CI: 82 %-97 %) adenomas and 12 of 21 (57.1 %, 95 % CI: 34 %-78 %) non-adenomas while endoscopists made correct predictions in 52 of 69 (75.4 %, 95 % CI: 60 %-85 %) and 20 of 21 (95.2 %, 95 % CI: 76 %-100 %), respectively. The global accuracy was 83.3 % (95 % CI: 74%-90 %) and 80 % (95 % CI: 70 %-88 %) for ATENEA and endoscopists, respectively. Conclusion ATENEA can accurately be used for in vivo characterization of colorectal polyps, enabling the endoscopist to make direct decisions. ATENEA showed a global accuracy similar to that of endoscopists despite an unsatisfactory performance for non-adenomatous lesions.