Pasar al contenido principal

ORTESIS HIBRIDA MOTOR-FES DE BAJO COSTE PARA LA MARCHA DE LESIONADOS MEDULARES Y METODOS DE SIMULACION PARA AYUDA AL DISEÑO Y LA ADAPTACION

DPI2015-65959-C3-2-R

•
Nombre agencia financiadora Ministerio de Economía y Competitividad
Acrónimo agencia financiadora MINECO
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2015
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Unidad de gestión Dirección General de Investigación Científica y Técnica
Centro beneficiario UNIVERSITAT POLITECNICA DE CATALUNYA
Identificador persistente http://dx.doi.org/10.13039/501100003329

Resultados relacionados

Resultados totales (Incluyendo duplicados): 36
Encontrada(s) 1 página(s)

UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Foot-ground contact modelling for computational prediction of human walking motion

  • Febrer Nafría, Miriam|||0000-0002-1189-835X
  • Pàmies Vilà, Rosa|||0000-0002-3814-9199
  • Font Llagunes, Josep Maria|||0000-0002-7192-2980
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Design, control and evaluation of a low-cost active orthosis for the gait of spinal cord injured subjects

  • Font Llagunes, Josep Maria|||0000-0002-7192-2980
  • Clos Costa, Daniel|||0000-0001-7530-930X
  • Lugrís Armesto, Urbano
  • Romero Sánchez, Francisco
  • Pàmies Vilà, Rosa|||0000-0002-3814-9199
  • Alonso Sánchez, Francisco Javier
  • Cuadrado Aranda, Javier
Robotic gait training after spinal cord injury is of high priority to maximize independence and improve the living conditions of the patients. Current rehabilitation robots are expensive and heavy, and are generally found only in the clinical environment. To overcome these issues, we present the design of a low-cost, low-weight and personalized robotic orthosis for incomplete spinal cord injured subjects. The paper also presents a preliminary experimental evaluation of the assistive device on one subject with spinal cord injury that can control hip flexion to a certain extent, but lacks control of knee and ankle muscles. Results show that gait velocity, stride length and cadence of walking increased (24,11%, 7,41% and 15,56%, respectively) when wearing active orthoses compared to the case when the subject used the usual passive orthoses.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Can the use of an auditory feedback device improve the gait pattern of paediatric patients with hemiparesis?

  • Muñoz Farré, Anna
  • Febrer Nafría, Miriam|||0000-0002-1189-835X
  • Pajares, Ismael
  • Febrer, Anna
  • Pàmies Vilà, Rosa|||0000-0002-3814-9199
  • Font Llagunes, Josep Maria|||0000-0002-7192-2980
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Evaluation of motion/force transmission between passive/active orthosis and subject through forward dynamic analysis

  • Mouzo, Francisco
  • Lugrís Armesto, Urbano
  • Cuadrado Aranda, Javier
  • Font Llagunes, Josep Maria|||0000-0002-7192-2980
  • Alonso Sánchez, Francisco Javier
Forward dynamic analysis of the acquired gait of subjects assisted by either passive or active knee-ankle-foot orthoses and crutches is used to evaluate the motion and force transmission between orthosis and subject depending on the connecting stiffness. Unlike inverse dynamic analysis, this approach allows to consider the subject’s limbs and the assistive devices as different entities, so that their relative behavior may be studied. The quality of motion transmission and the intensity of interface forces are evaluated for a range of connecting stiffness values, so that those providing the best trade-off between both aspects can be identified.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Dynamical analysis and design of active orthoses by aesthetic and energetic optimization

UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Design of personalised active orthoses for spinal cord-injured subjects based on optimal control prediction of assisted walking motions

  • Font Llagunes, Josep Maria|||0000-0002-7192-2980
  • Febrer Nafría, Miriam|||0000-0002-1189-835X
  • Fregly, Benjamin J.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Simulación predictiva de la marcha asistida para la personalización de ortesis activas para lesionados medulares

  • Febrer Nafría, Miriam|||0000-0002-1189-835X
  • Pallarès López, Roger
  • Font Llagunes, Josep Maria|||0000-0002-7192-2980
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Evaluation of optimal control formulations for obtaining dynamically consistent walking motions

  • Pallarès López, Roger
  • Febrer Nafría, Miriam|||0000-0002-1189-835X
  • Fregly, Benjamin Jon
  • Font Llagunes, Josep Maria|||0000-0002-7192-2980
n recent years, interest has grown in predicting human motion, for example, to study cause-effect relations for a specific task [1]. To predict human motion, researchers typically use optimization-based methods that minimize a certain cost function. The objective of this study is to analyze two different optimal control formulations that track experimental data from a healthy gait cycle to obtain a dynamically consistent walking motion, i.e., with minimal residual wrench applied to the pelvis.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Design and experimental evaluation of a low-cost robotic orthosis for gait assistance in subjects with spinal cord injury

  • Font Llagunes, Josep Maria|||0000-0002-7192-2980
  • Clos Costa, Daniel|||0000-0001-7530-930X
  • Lugrís Armesto, Urbano
  • Alonso Sánchez, Francisco Javier
  • Cuadrado Aranda, Javier
Robotic gait training after spinal cord injury (SCI) is of high priority to maximize independence and improve the living conditions of these patients. Current rehabilitation robots are expensive and heavy, and are generally found only in the clinic. To overcome these issues, we present the design of a low-cost, low-weight robotic orthosis for subjects with SCI. The paper also presents a preliminary experimental evaluation of the assistive device on a subject with SCI. Results show that gait velocity, stride length and cadence of walking increased (24.11, 7.41 and 15.56 %, respectively) when wearing active orthoses compared to the case with standard passive orthoses.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Influence of robotic orthosis dynamic parameters on optimization-based prediction of assisted walking

  • Febrer Nafría, Miriam|||0000-0002-1189-835X
  • Font Llagunes, Josep Maria|||0000-0002-7192-2980
  • García-Vallejo, Daniel
The numerical simulation by parameter optimization techniques has been proven to be a powerful tool in human walking dynamics research [1, 2]. Although there are several studies related to human walking dynamics, not much attention has been paid to the prediction of human gait assisted by robotic orthoses or exoskeletons. The aim of this work is to investigate the influence of some design parameters of an assistive orthosis on the injured subject’s gait dynamics by using a predictive parameter optimization approach.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Personalised active orthoses for SCI subjects based on optimal control prediction

  • Febrer Nafría, Miriam|||0000-0002-1189-835X
  • Pallarès López, Roger
  • Fregly, Benjamin Jon
  • Font Llagunes, Josep Maria|||0000-0002-7192-2980
The authors are working on the personalisation of an innovative low-cost, lightweight, and easy-to-use active orthosis to facilitate over-ground walking with crutches by individuals with spinal cord injury (SCI) who possess remaining hip function. Personalisation will involve selection of the best knee motor control strategy for each subject, using predictive walking simulations that combine OpenSim patient-specific models with GPOPS-II optimal control predictions. In the present work, we describe a direct collocation optimal control framework to obtain a dynamically consistent walking motion that reproduces experimental measurements.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

ABLE: assistive biorobotic low-cost exoskeleton

  • Font Llagunes, Josep Maria|||0000-0002-7192-2980
  • Carnicero Carmona, Alfons
  • Vidal Samsó, Joan
  • Clos Costa, Daniel|||0000-0001-7530-930X
  • Lugrís Armesto, Urbano
  • Alonso Sánchez, Francisco Javier
  • Cuadrado Aranda, Javier
Robotic gait training after spinal cord injury is of high priority to maximize independence and improve the health condition of these patients. Current rehabilitation robots are expensive and heavy, and are generally found only in the clinic. To overcome these issues, we present the design of a low-cost, low-weight, personalized and easy-to-use robotic exoskeleton for incomplete spinal cord injured subjects based on simple modular components that are assembled on the current passive orthopedic supports. The paper also presents a preliminary experimental assessment of the assistive device on one subject with spinal cord injury that can control hip flexion, but lacks control of knee and ankle muscles. Results show that gait velocity, stride length and cadence of walking increased (24,11%, 7,41% and 15,56%, respectively) when wearing the robotic exoskeleton compared to the case when the subject used the usual passive supports.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Design, control, and pilot study of a lightweight and modular robotic exoskeleton for walking assistance after spinal cord injury

  • Font Llagunes, Josep Maria|||0000-0002-7192-2980
  • Lugrís Armesto, Urbano
  • Clos Costa, Daniel|||0000-0001-7530-930X
  • Alonso Sánchez, Francisco Javier
  • Cuadrado Aranda, Javier
Walking rehabilitation using exoskeletons is of high importance to maximize independence and improve the general well-being of spinal cord injured subjects. We present the design and control of a lightweight and modular robotic exoskeleton to assist walking in spinal cord injured subjects who can control hip flexion, but lack control of knee and ankle muscles. The developed prototype consists of two robotic orthoses, which are powered by a motor-harmonic drive actuation system that controls knee flexion–extension. This actuation module is assembled on standard passive orthoses. Regarding the control, the stance-to-swing transition is detected using two inertial measurement units mounted on the tibial supports, and then the corresponding motor performs a predefined flexion–extension cycle that is personalized to the specific patient’s motor function. The system is portable by means of a backpack that contains an embedded computer board, the motor drivers, and the battery. A preliminary biomechanical evaluation of the gait-assistive device used by a female patient with incomplete spinal cord injury at T11 is presented. Results show an increase of gait speed (+24.11%), stride length (+7.41%), and cadence (+15.56%) when wearing the robotic orthoses compared with the case with passive orthoses. Conversely, a decrease of lateral displacement of the center of mass (-19.31%) and step width (-13.37% right step, -8.81% left step) are also observed, indicating gain of balance. The biomechanical assessment also reports an overall increase of gait symmetry when wearing the developed assistive device., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Calibration and validation of a skeletal multibody model for leg-orthosis contact force estimation

  • Mouzo, Francisco
  • Lugrís Armesto, Urbano
  • Cuadrado Aranda, Javier
  • Font Llagunes, Josep Maria|||0000-0002-7192-2980
  • Alonso Sánchez, Francisco Javier
Estimation of contact forces between lower limb and orthosis duringgait is useful to prevent skin issues in subjects wearing this type of assistivedevices. While inverse-dynamics based gait analysis of multibody models isdifficult to apply due to the limited accuracy of motion capture systems, aforward-dynamics based analysis in which leg and orthosis are considered asindependent entities is shown to provide acceptable results. Contact modelparameters are calibrated through comparison of measured and calculatedbending torque at the orthosis location where a load cell is installed, and theattained correlation allows to validate the model, Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Impact of friction and gait parameters on the optimization of series elastic actuators for gait assistance

  • Stuhlenmiller, Florian
  • Clos Costa, Daniel|||0000-0001-7530-930X
  • Rinderknecht, Stephan
  • Beckerle, Philipp
  • Font Llagunes, Josep Maria|||0000-0002-7192-2980
Elastic actuators feature increased energy efficiency and improved human-robot interaction compared to directly driven concepts for active orthoses and prostheses. Structure and parameters of the elastic actuation system are often designed via a model-based minimization of energy consumption based on gait data gained from healthy individuals. However, natural motion exhibits variability among individuals and may not consider requirements of persons using assistive devices. A parametric study is performed examining the impact of varying gait characteristics on the energy consumption and constraints of an optimized (clutchable) series elastic actuator of the knee joint. Furthermore, friction parameters are varied to analyze the impact on actuator constraints. Results of the parametric study indicate increased energy consumption for a slower cadence compared to the healthy gait data for both systems. The clutchable series elastic actuator is less impacted by constraints than the series elastic actuator. The utilized models are evaluated experimentally at a test bench, indicating good accordance to the measured energy consumption. The results highlight the interrelation of friction and gait parameters with energy consumption and actuator constraints and indicate that the optimization procedure for the actuator design requires detailed models of component efficiency as well as subject-specific gait characteristics.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Low-cost active orthosis for gait assistance of subjects with spinal cord injury

  • Font Llagunes, Josep Maria|||0000-0002-7192-2980
  • Lugrís Armesto, Urbano
  • Febrer Nafría, Miriam|||0000-0002-1189-835X
  • Romero Sánchez, Francisco
  • Pàmies Vilà, Rosa|||0000-0002-3814-9199
  • Alonso Sánchez, Francisco Javier
  • Cuadrado Aranda, Javier
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Kinematic model of savannah monitor locomotion

  • Klodowski, Adam
  • Febrer Nafría, Miriam|||0000-0002-1189-835X
  • Martínez Silvestre, Albert
  • Font Llagunes, Josep Maria|||0000-0002-7192-2980
  • Fortuny Terricabras, Josep|||0000-0003-4282-1619
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Evaluation of Optimal Control Approaches for Predicting Active Knee-Ankle-Foot-Orthosis Motion for Individuals With Spinal Cord Injury

  • Febrer Nafría, Miriam|||0000-0002-1189-835X
  • Fregly, Benjamin Jon
  • Font Llagunes, Josep Maria|||0000-0002-7192-2980
Gait restoration of individuals with spinal cord injury can be partially achieved using active orthoses or exoskeletons. To improve the walking ability of each patient as much as possible, it is important to personalize the parameters that define the device actuation. This study investigates whether using an optimal control-based predictive simulation approach to personalize pre-defined knee trajectory parameters for an active knee-ankle-foot orthosis (KAFO) used by spinal cord injured (SCI) subjects could potentially be an alternative to the current trial-and-error approach. We aimed to find the knee angle trajectory that produced an improved orthosis-assisted gait pattern compared to the one with passive support (locked knee). We collected experimental data from a healthy subject assisted by crutches and KAFOs (with locked knee and with knee flexion assistance) and from an SCI subject assisted by crutches and KAFOs (with locked knee). First, we compared different cost functions and chose the one that produced results closest to experimental locked knee walking for the healthy subject (angular coordinates mean RMSE was 5.74°). For this subject, we predicted crutch-orthosis-assisted walking imposing a pre-defined knee angle trajectory for different maximum knee flexion parameter values, and results were evaluated against experimental data using that same pre-defined knee flexion trajectories in the real device. Finally, using the selected cost function, gait cycles for different knee flexion assistance were predicted for an SCI subject. We evaluated changes in four clinically relevant parameters: foot clearance, stride length, cadence, and hip flexion ROM. Simulations for different values of maximum knee flexion showed variations of these parameters that were consistent with experimental data for the healthy subject (e.g., foot clearance increased/decreased similarly in experimental and predicted motions) and were reasonable for the SCI subject (e.g., maximum parameter values were found for moderate knee flexion). Although more research is needed before this method can be applied to choose optimal active orthosis controller parameters for specific subjects, these findings suggest that optimal control prediction of crutch-orthosis-assisted walking using biomechanical models might be used in place of the trial-and-error method to select the best maximum knee flexion angle during gait for a specific SCI subject., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Design, control, and pilot study of a lightweight and modular robotic exoskeleton for walking assistance after spinal cord injury

  • Font Llagunes, Josep Maria
  • Lugrís Armesto, Urbano
  • Clos Costa, Daniel
  • Alonso Sánchez, Francisco Javier
  • Cuadrado Aranda, Javier
Walking rehabilitation using exoskeletons is of high importance to maximize independence and improve the general well-being of spinal cord injured subjects. We present the design and control of a lightweight and modular robotic exoskeleton to assist walking in spinal cord injured subjects who can control hip flexion, but lack control of knee and ankle muscles. The developed prototype consists of two robotic orthoses, which are powered by a motor-harmonic drive actuation system that controls knee flexion–extension. This actuation module is assembled on standard passive orthoses. Regarding the control, the stance-to-swing transition is detected using two inertial measurement units mounted on the tibial supports, and then the corresponding motor performs a predefined flexion–extension cycle that is personalized to the specific patient’s motor function. The system is portable by means of a backpack that contains an embedded computer board, the motor drivers, and the battery. A preliminary biomechanical evaluation of the gait-assistive device used by a female patient with incomplete spinal cord injury at T11 is presented. Results show an increase of gait speed (+24.11%), stride length (+7.41%), and cadence (+15.56%) when wearing the robotic orthoses compared with the case with passive orthoses. Conversely, a decrease of lateral displacement of the center of mass (-19.31%) and step width (-13.37% right step, -8.81% left step) are also observed, indicating gain of balance. The biomechanical assessment also reports an overall increase of gait symmetry when wearing the developed assistive device., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Evaluation of optimal control formulations for obtaining dynamically consistent walking motions

  • Pallarès López, Roger
  • Febrer Nafría, Miriam
  • Fregly, Benjamin Jon
  • Font Llagunes, Josep Maria
n recent years, interest has grown in predicting human motion, for example, to study cause-effect relations for a specific task [1]. To predict human motion, researchers typically use optimization-based methods that minimize a certain cost function. The objective of this study is to analyze two different optimal control formulations that track experimental data from a healthy gait cycle to obtain a dynamically consistent walking motion, i.e., with minimal residual wrench applied to the pelvis., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Design, control and evaluation of a low-cost active orthosis for the gait of spinal cord injured subjects

  • Font Llagunes, Josep Maria
  • Clos Costa, Daniel
  • Lugrís Armesto, Urbano
  • Romero Sánchez, Francisco
  • Pàmies Vilà, Rosa
  • Alonso Sánchez, Francisco Javier
  • Cuadrado Aranda, Javier
Robotic gait training after spinal cord injury is of high priority to maximize independence and improve the living conditions of the patients. Current rehabilitation robots are expensive and heavy, and are generally found only in the clinical environment. To overcome these issues, we present the design of a low-cost, low-weight and personalized robotic orthosis for incomplete spinal cord injured subjects. The paper also presents a preliminary experimental evaluation of the assistive device on one subject with spinal cord injury that can control hip flexion to a certain extent, but lacks control of knee and ankle muscles. Results show that gait velocity, stride length and cadence of walking increased (24,11%, 7,41% and 15,56%, respectively) when wearing active orthoses compared to the case when the subject used the usual passive orthoses., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Influence of robotic orthosis dynamic parameters on optimization-based prediction of assisted walking

  • Febrer Nafría, Miriam
  • Font Llagunes, Josep Maria
  • García-Vallejo, Daniel
The numerical simulation by parameter optimization techniques has been proven to be a powerful tool in human walking dynamics research [1, 2]. Although there are several studies related to human walking dynamics, not much attention has been paid to the prediction of human gait assisted by robotic orthoses or exoskeletons. The aim of this work is to investigate the influence of some design parameters of an assistive orthosis on the injured subject’s gait dynamics by using a predictive parameter optimization approach., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

ABLE: assistive biorobotic low-cost exoskeleton

  • Font Llagunes, Josep Maria
  • Carnicero Carmona, Alfons
  • Vidal Samsó, Joan
  • Clos Costa, Daniel
  • Lugrís Armesto, Urbano
  • Alonso Sánchez, Francisco Javier
  • Cuadrado Aranda, Javier
Robotic gait training after spinal cord injury is of high priority to maximize independence and improve the health condition of these patients. Current rehabilitation robots are expensive and heavy, and are generally found only in the clinic. To overcome these issues, we present the design of a low-cost, low-weight, personalized and easy-to-use robotic exoskeleton for incomplete spinal cord injured subjects based on simple modular components that are assembled on the current passive orthopedic supports. The paper also presents a preliminary experimental assessment of the assistive device on one subject with spinal cord injury that can control hip flexion, but lacks control of knee and ankle muscles. Results show that gait velocity, stride length and cadence of walking increased (24,11%, 7,41% and 15,56%, respectively) when wearing the robotic exoskeleton compared to the case when the subject used the usual passive supports., Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Can the use of an auditory feedback device improve the gait pattern of paediatric patients with hemiparesis?

Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Impact of friction and gait parameters on the optimization of series elastic actuators for gait assistance

  • Stuhlenmiller, Florian
  • Clos Costa, Daniel
  • Rinderknecht, Stephan
  • Beckerle, Philipp
  • Font Llagunes, Josep Maria
Elastic actuators feature increased energy efficiency and improved human-robot interaction compared to directly driven concepts for active orthoses and prostheses. Structure and parameters of the elastic actuation system are often designed via a model-based minimization of energy consumption based on gait data gained from healthy individuals. However, natural motion exhibits variability among individuals and may not consider requirements of persons using assistive devices. A parametric study is performed examining the impact of varying gait characteristics on the energy consumption and constraints of an optimized (clutchable) series elastic actuator of the knee joint. Furthermore, friction parameters are varied to analyze the impact on actuator constraints. Results of the parametric study indicate increased energy consumption for a slower cadence compared to the healthy gait data for both systems. The clutchable series elastic actuator is less impacted by constraints than the series elastic actuator. The utilized models are evaluated experimentally at a test bench, indicating good accordance to the measured energy consumption. The results highlight the interrelation of friction and gait parameters with energy consumption and actuator constraints and indicate that the optimization procedure for the actuator design requires detailed models of component efficiency as well as subject-specific gait characteristics., Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Personalised active orthoses for SCI subjects based on optimal control prediction

  • Febrer Nafría, Miriam
  • Pallarès López, Roger
  • Fregly, Benjamin Jon
  • Font Llagunes, Josep Maria
The authors are working on the personalisation of an innovative low-cost, lightweight, and easy-to-use active orthosis to facilitate over-ground walking with crutches by individuals with spinal cord injury (SCI) who possess remaining hip function. Personalisation will involve selection of the best knee motor control strategy for each subject, using predictive walking simulations that combine OpenSim patient-specific models with GPOPS-II optimal control predictions. In the present work, we describe a direct collocation optimal control framework to obtain a dynamically consistent walking motion that reproduces experimental measurements., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Low-cost active orthosis for gait assistance of subjects with spinal cord injury

  • Font Llagunes, Josep Maria
  • Lugrís Armesto, Urbano
  • Febrer Nafría, Miriam
  • Romero Sánchez, Francisco
  • Pàmies Vilà, Rosa
  • Alonso Sánchez, Francisco Javier
  • Cuadrado Aranda, Javier
Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Dynamical analysis and design of active orthoses by aesthetic and energetic optimization

Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Kinematic model of savannah monitor locomotion

Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Evaluation of Optimal Control Approaches for Predicting Active Knee-Ankle-Foot-Orthosis Motion for Individuals With Spinal Cord Injury

  • Febrer Nafría, Miriam
  • Fregly, Benjamin Jon
  • Font Llagunes, Josep Maria
Gait restoration of individuals with spinal cord injury can be partially achieved using active orthoses or exoskeletons. To improve the walking ability of each patient as much as possible, it is important to personalize the parameters that define the device actuation. This study investigates whether using an optimal control-based predictive simulation approach to personalize pre-defined knee trajectory parameters for an active knee-ankle-foot orthosis (KAFO) used by spinal cord injured (SCI) subjects could potentially be an alternative to the current trial-and-error approach. We aimed to find the knee angle trajectory that produced an improved orthosis-assisted gait pattern compared to the one with passive support (locked knee). We collected experimental data from a healthy subject assisted by crutches and KAFOs (with locked knee and with knee flexion assistance) and from an SCI subject assisted by crutches and KAFOs (with locked knee). First, we compared different cost functions and chose the one that produced results closest to experimental locked knee walking for the healthy subject (angular coordinates mean RMSE was 5.74°). For this subject, we predicted crutch-orthosis-assisted walking imposing a pre-defined knee angle trajectory for different maximum knee flexion parameter values, and results were evaluated against experimental data using that same pre-defined knee flexion trajectories in the real device. Finally, using the selected cost function, gait cycles for different knee flexion assistance were predicted for an SCI subject. We evaluated changes in four clinically relevant parameters: foot clearance, stride length, cadence, and hip flexion ROM. Simulations for different values of maximum knee flexion showed variations of these parameters that were consistent with experimental data for the healthy subject (e.g., foot clearance increased/decreased similarly in experimental and predicted motions) and were reasonable for the SCI subject (e.g., maximum parameter values were found for moderate knee flexion). Although more research is needed before this method can be applied to choose optimal active orthosis controller parameters for specific subjects, these findings suggest that optimal control prediction of crutch-orthosis-assisted walking using biomechanical models might be used in place of the trial-and-error method to select the best maximum knee flexion angle during gait for a specific SCI subject., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Foot-ground contact modelling for computational prediction of human walking motion

Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Design of personalised active orthoses for spinal cord-injured subjects based on optimal control prediction of assisted walking motions

Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Design and experimental evaluation of a low-cost robotic orthosis for gait assistance in subjects with spinal cord injury

  • Font Llagunes, Josep Maria
  • Clos Costa, Daniel
  • Lugrís Armesto, Urbano
  • Alonso Sánchez, Francisco Javier
  • Cuadrado Aranda, Javier
Robotic gait training after spinal cord injury (SCI) is of high priority to maximize independence and improve the living conditions of these patients. Current rehabilitation robots are expensive and heavy, and are generally found only in the clinic. To overcome these issues, we present the design of a low-cost, low-weight robotic orthosis for subjects with SCI. The paper also presents a preliminary experimental evaluation of the assistive device on a subject with SCI. Results show that gait velocity, stride length and cadence of walking increased (24.11, 7.41 and 15.56 %, respectively) when wearing active orthoses compared to the case with standard passive orthoses., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Evaluation of motion/force transmission between passive/active orthosis and subject through forward dynamic analysis

  • Mouzo, Francisco
  • Lugrís Armesto, Urbano
  • Cuadrado Aranda, Javier
  • Font Llagunes, Josep Maria
  • Alonso Sánchez, Francisco Javier
Forward dynamic analysis of the acquired gait of subjects assisted by either passive or active knee-ankle-foot orthoses and crutches is used to evaluate the motion and force transmission between orthosis and subject depending on the connecting stiffness. Unlike inverse dynamic analysis, this approach allows to consider the subject’s limbs and the assistive devices as different entities, so that their relative behavior may be studied. The quality of motion transmission and the intensity of interface forces are evaluated for a range of connecting stiffness values, so that those providing the best trade-off between both aspects can be identified., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Calibration and validation of a skeletal multibody model for leg-orthosis contact force estimation

  • Mouzo, Francisco
  • Lugrís Armesto, Urbano
  • Cuadrado Aranda, Javier
  • Font Llagunes, Josep Maria
  • Alonso Sánchez, Francisco Javier
Estimation of contact forces between lower limb and orthosis duringgait is useful to prevent skin issues in subjects wearing this type of assistivedevices. While inverse-dynamics based gait analysis of multibody models isdifficult to apply due to the limited accuracy of motion capture systems, aforward-dynamics based analysis in which leg and orthosis are considered asindependent entities is shown to provide acceptable results. Contact modelparameters are calibrated through comparison of measured and calculatedbending torque at the orthosis location where a load cell is installed, and theattained correlation allows to validate the model, Peer Reviewed, Postprint (published version)