Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 10
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Air-coupled and resonant pulse-echo ultrasonic technique

  • Gómez Álvarez-Arenas, Tomás
  • Camacho Sosa-Días, Jorge
© The Author(s)., An ultrasonic, resonant, pulse-echo, and air-coupled nondestructive testing (NDT) technique is presented. It is intended for components, with regular geometries where it is possible to excite resonant modes, made of materials that have a high acoustic impedance (Z) and low attenuation coefficient (α). Under these conditions, these resonances will present a very large quality factor (Q) and decay time (τ). This feature is used to avoid the dead zone, produced by the echo coming from the first wall, by receiving the resonant echo from the whole specimen over a longer period of time. This echo is analyzed in the frequency domain to determine specimen resonant frequency, which can be further used to determine either velocity or thickness. Using wideband air-coupled transducers, we tested the technique on plates (steel, aluminum, and silicone rubber) by exciting the mode of the first thickness. As expected, the higher the Z and the lower the α, the better the technique performed. Sensitivity to deviations of the angle of incidence away from normal (±2°) and the possibility to generate shear waves were also studied. Then, it was tested on steel cylindrical pipes that had different wall thicknesses and diameters. Finally, the use of this technique to generate C-Scan images of steel plates with different thicknesses was demonstrated., This research was funded by grant (DPI2016-78876-R-AEI/FEDER, UE) from the Spanish State Research Agency (AEI) and the European Regional Development Fund (ERDF/FEDER), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Instantaneous and non-destructive relative water content estimation from deep learning applied to resonant ultrasonic spectra of plant leaves

  • Fariñas, María Dolores
  • Jimenez-Carretero, Daniel
  • Sancho-Knapik, Domingo
  • Peguero-Pina, José Javier
  • Gil-Pelegrín, Eustaquio
  • Gómez Álvarez-Arenas, Tomás
[Background] Non-contact resonant ultrasound spectroscopy (NC-RUS) has been proven as a reliable technique for the dynamic determination of leaf water status. It has been already tested in more than 50 plant species. In parallel, relative water content (RWC) is highly used in the ecophysiological field to describe the degree of water saturation in plant leaves. Obtaining RWC implies a cumbersome and destructive process that can introduce artefacts and cannot be determined instantaneously., [Results] Here, we present a method for the estimation of RWC in plant leaves from non-contact resonant ultrasound spectroscopy (NC-RUS) data. This technique enables to collect transmission coefficient in a [0.15–1.6] MHz frequency range from plant leaves in a non-invasive, non-destructive and rapid way. Two different approaches for the proposed method are evaluated: convolutional neural networks (CNN) and random forest (RF). While CNN takes the entire ultrasonic spectra acquired from the leaves, RF only uses four relevant parameters resulted from the transmission coefficient data. Both methods were tested successfully in Viburnum tinus leaf samples with Pearson’s correlations between 0.92 and 0.84., [Conclusions] This study showed that the combination of NC-RUS technique with deep learning algorithms is a robust tool for the instantaneous, accurate and non-destructive determination of RWC in plant leaves., This research was supported by Grant (DPI2016-78876-R-AEI/FEDER, UE) from the Spanish State Research Agency (AEI) and the European Regional Development Fund (ERDF/FEDER). It was also partially funded by Instituto Nacional de Investigación y Tecnología Agraria y Alimentaria (INIA) Grant number RTA2015-00054-C02-01 and by Gobierno de Aragón H09_17R research group (DOC INIA-CCAA (ESF)). Funding was provided by Conselleria d’Educació, Investigació, Cultura i Esport (APOSTD/2018/203 (ESF))., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Effects of a social force model reward in robot navigation based on deep reinforcement learning

  • Gil Viyuela, Óscar
  • Sanfeliu, Alberto
Trabajo presentado en el 4th Iberian Robotics Conference, celebrado en Oporto (Portugal) en noviembre de 2019, In this paper is proposed an inclusion of the Social Force Model (SFM) into a concrete Deep Reinforcement Learning (RL) framework for robot navigation. These types of techniques have demonstrated to be useful to deal with different types of environments to achieve a goal. In Deep RL, a description of the world to describe the states and a reward adapted to the environment are crucial elements to get the desire behaviour and achieve a high performance. For this reason, this work adds a dense reward function based on SFM and uses the forces in the states like an additional description. Furthermore, obstacles are added to improve the behaviour of works that only consider moving agents. This SFM inclusion can offer a better description of the obstacles for the navigation. Several simulations have been done to check the effects of these modifications in the average performance., Work supported by the Spanish Ministry of Science and Innovation under project ColRobTransp (DPI2016-78957-RAEI/FEDER EU) and by the Spanish State Research Agency through the María de Maeztu Seal of Excellence to IRI (MDM-2016-0656). Óscar Gil is also supported by Spanish Ministry of Science and Innovation under a FPI-grant, BES-2017-082126.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Ferroelectret Ultrasonic Transducers for Pulse-Echo Water Immersion

  • Quirce Aguilar, Julio
  • Svilainis, Linas
  • Camacho Sosa-Días, Jorge
  • Gómez Álvarez-Arenas, Tomás
Ferroelectrets are thin and porous polymeric films with a cellular microstructure, high porosity, permanent polarization and piezoelectric response. They have been used for different applications, where one of the most interesting ones is for the fabrication of air-coupled ultrasonic transducers. More recently they have been tested as water immersion transducers, showing a promising wide bandwidth but limited sensitivity along with other technical problems. This paper investigates ultrasonic transducers for water immersion and pulse-echo operation based on ferroelectret films. Two different ferroelectret foams with different resonant frequencies, acoustic impedances and cellular structures were tried. Flat and spherically focused prototypes (radius of curvature of 22 and 35 mm) were produced and tested. Finally, different materials and methods were tried to provide a protective surface coating. Acoustic field measurements for the focused transducers confirm the possibility to efficiently focus the ultrasonic beam by the proposed fabrication method, with focal spot size of 1.86 mm at −6 dB. Results show that in spite of the reduced sensitivity (about −115 dB), some of the tried ferroelectret films provide a very wide band response (−6 dB band from 0.29 to 2.7 MHz) and short pulse duration (2–3 us) that can be of interest for different applications, This work was supported in part by Ministerio de Economía y Competitividad under grants ECERES (DPI2016- 78876-R, AEI/FEDER, UE) and AIMUT (RTI2018-099118-A-I00, MCIU/AEI/FEDER, UE) and received partial funding (LS) from European Regional Development Fund (project No. 01.2.2-LMT-K-718-03-0026) under grant agreement with the Research Council of Lithuania (LMTLT)., This work was supported in part by Ministerio de Economía y Competitividad under grants ECERES (DPI2016- 78876-R, AEI/FEDER, UE) and AIMUT (RTI2018-099118-A-I00, MCIU/AEI/FEDER, UE) and received partial funding (LS) from European Regional Development Fund (project No. 01.2.2-LMT-K-718-03-0026) under grant agreement with the Research Council of Lithuania (LMTLT)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Interpretation of the thickness resonances in ferroelectret films based on a layered sandwich mesostructure and a cellular microstructure.

  • Quirce Aguilar, Julio
  • Muñoz, Manuel
  • Gómez Álvarez-Arenas, Tomás
Transmission coefficient spectra of two ferroelectret films (showing several thickness resonances) measured with aircoupled ultrasound (0.2–3.5MHz) are presented and an explanation for the observed behavior is provided by proposing a film layered sandwich mesostructure (skin/core/skin) and by solving the inverse problem, using a simulated annealing algorithm. This permits to extract the value of the ultrasonic parameters of the different layers in the film as well as overall film parameters. It is shown that skin layers are thinner, denser and softer than core layers and also present lower acoustic impedance. Similarly, it is also obtained that the denser film also presents lower overall acoustic impedance. Scanning Electron Microscopy was employed to analyze the films cross-section, revealing that both denser films and film layers present more flattened cells and that close to the surface cells tends to be more flattened (supporting the proposed sandwich model). The fact that more flattened cells contributes to a lower elastic modulus and acoustic impedance can be explained, as it has been made previously by several authors, by the fact that the macroscopic film elastic response is furnished by cell micromechanics which is governed, mainly, by cell wall bending. Consistency of extracted parameters with trends shown by a simple model based on a honeycomb microstructure is discussed as well as the possibilities that this sandwich mesostructure and the associated impedance gradient could offer to improve the performance of FE films in ultrasonic transducers., Ministerio de Economía y Competitividad under grant DPI2016- 78876-R, AEI/FEDER, UE)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Surface Density of the Spongy and Palisade Parenchyma Layers of Leaves Extracted From Wideband Ultrasonic Resonance Spectra

  • Gómez Álvarez-Arenas, Tomás
  • Sancho-Knapik, Domingo
  • Peguero-Pina, José Javier
  • Gil-Pelegrín, Eustaquio
The wide band and air-coupled ultrasonic resonant spectroscopy together with a modified Simulated Annealing metaheuristic algorithm and a 1D layered acoustic-model are used to resolve the structure of plant leaves. In particular, this paper focuses on the extraction of the surface density of the different layers of tissue in leaves having a relatively simple structure. There are three main reasons to select the surface density as the focus of this study: (i) it is a parameter directly extracted by the proposed technique and it requires no further processing, (ii) it is relevant in order to study the dynamic of the water within the different tissues of the leaves and also to study the differential development of the different tissues, and (iii) unlike other parameters provided by this technique (like resonant frequency, impedance, ultrasonic elastic modulus, or ultrasonic damping), this parameter can be easier to understand as it is a direct measure of mass per unit surface. The selection of leaves with a simple structure is justified by the convenience of avoiding an unnecessary complication of the data extraction step. In this work, the technique was applied to determine the surface density of the palisade and spongy parenchyma layers of tissue of Ligustrum lucidum, Vitis vinifera, and Viburnum tinus leaves. The first species was used to study the variation of the surface density at full turgor with the thickness of the leaf, while the two other species were used to study the variation of the surface densities with the variation in the leaf relative water content. Consistency of the results with other conventional measurements (like overall surface density, and cross-section optical and cryo-SEM images) is discussed. The results obtained reveal the potential of this technique; moreover, the technique presents the additional advantage that can be applied in-vivo as it is completely non-invasive, non-destructive, fast, and equipment required is portable., Instituto Nacional de Investigación y Tecnología Agraria y Alimentaria (INIA) grant no. RTA2015- 00054-C02-01 and by Gobierno de Aragón H09_20R research group. Research of DS-K is supported by a DOC INIACCAA contract co-funded by INIA and European Social Fund and by the Spanish State Research Agency and European Regional Development Fund (ERDF/FEDER), grant no. DPI2016−78876−R., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

High frequency focused imaging for ultrasonic probe integrity inspection

  • Svilainis, Linas
  • Kybartas, Darius
  • Aleksandrovas, Arturas
  • Gómez Álvarez-Arenas, Tomás
Most ultrasonic probes present a layered structure that may comprise delay lines, acoustic lens, wear plates, matching layers, electrodes, piezoelectric layers, and a backing block. Probe integrity can be compromised by different defects, such as deficient bonding, presence of air bubbles or porosity, lack of electrical conductivity in electrodes, and deviations in the layers' acoustic thicknesses, impedances or attenuation values. Conventional testing procedures are based on the integral properties of the probe, such as acoustic directivity, sensitivity, and electrical impedance. An alternative technique for the non-destructive inspection of the probe's integrity is presented in this study. The proposed technique is based on imaging of the internal structure using a higher frequency focused ultrasound. Scanning the probe's surface using this focused beam provides two imaging modes: reflection and transmission. In the reflection mode, the higher intensity of the echoes indicates the presence of the defects, such as disbonds, poor acoustic matching or porosity. The main novelty of the proposed technique is in the transmission mode: the probe's electric response to the high frequency focused beam is used to get a 2D distribution of transduction efficiency. Moreover, the probe's response can be gated to separate, both front and back side, responses in the time domain, so the local integrity of an electroacoustic structure is evaluated. To verify the proposed technique, a focused 20 MHz transducer with a focal spot diameter of 0.35 mm was mounted on an ultrasonic scanner and immersed in water above the surface of the probe to be tested. Signals were gated by the layers' thickness, giving the C-scan images corresponding to the different material interfaces inside the tested probes: front face, matching layers, piezoelement and backing. It was demonstrated that the resulting C-scan images are informative in evaluating probe's integrity and layers' acoustic thickness. Comparison of the C-scan images obtained in the reflection and transmission modes shows a good agreement in the structure deficiencies evaluation. The technique proposed is attractive due to its simplicity. It can be useful in several applications: i) the probes already in use can be verified and if any deficiencies are detected, the information obtained can be used to evaluate and guide repair; ii) fabrication quality can be verified by confirming the adhesion of layers and parameters in 2D; and iii) the development of new fabrication routes can be guided, where adherence, compatibility, homogeneity, etc. of new materials or new technologies can be evaluated., Funding by grant (DPI2016-78876-R-AEI/FEDER, UE) from the Spanish State Research Agency (AEI) and the European Union, EU, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Micronized Recycle Rubber Particles Modified Multifunctional Polymer Composites: Application to Ultrasonic Materials Engineering

  • Genovés, Vicente
  • Fariñas, María Dolores
  • Pérez-Aparicio, Roberto
  • Saiz-Rodríguez, L.
  • Valentín, Juan L.
  • Álvarez-Arenas, Tomás G.
There is a growing interest in multifunctional composites and in the identification of novel applications for recycled materials. In this work, the design and fabrication of multiple particle-loaded polymer composites, including micronized rubber from end-of-life tires, is studied. The integration of these composites as part of ultrasonic transducers can further expand the functionality of the piezoelectric material in the transducer in terms of sensitivity, bandwidth, ringing and axial resolution and help to facilitate the fabrication and use of phantoms for echography. The adopted approach is a multiphase and multiscale one, based on a polymeric matrix with a load of recycled rubber and tungsten powders. A fabrication procedure, compatible with transducer manufacturing, is proposed and successfully used. We also proposed a modelling approach to calculate the complex elastic modulus, the ultrasonic damping and to evaluate the relative influence of particle scattering. It is concluded that it is possible to obtain materials with acoustic impedance in the range 2.35–15.6 MRayl, ultrasound velocity in the range 790–2570 m/s, attenuation at 3 MHz, from 0.96 up to 27 dB/mm with a variation of the attenuation with the frequency following a power law with exponent in the range 1.2–3.2. These ranges of values permit us to obtain most of the material properties demanded in ultrasonic engineering., This research was funded by Ministerio de Economía y Competitividad (DPI2016-78876-R and MAT2017-87204-R), CSIC (201860E045) and Signus Ecovalor, S.L. Author J.L.V. is member of the SusPlast platform of CSIC
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Non-contact ultrasonic resonant spectroscopy resolves the elastic properties of layered plant tissues

  • Álvarez-Arenas, T.E.G.
  • Sancho-Knapik, D.
  • Peguero-Pina, J.J.
  • Gómez-Arroyo, A.
  • Gil-Pelegrín, E.
This paper describes the application of the wide-band non-contact ultrasonic resonant spectroscopy technique to layered plant tissues (leaves), a method to extract the properties of main component tissues: palisade parenchyma and spongy mesophyll, a verification of the obtained properties, and a discussion of the implications of the observed elastic anisotropy. Transmission coefficient spectra of Ligustrum lucidum leaves with the thickness in the range of 250-850 µm revealing several order thickness resonances have been measured. A leaf acoustic model based on a two-layered structure and a metaheuristic (simulated annealing algorithm) is used to solve the inverse problem. The extracted parameters of these two layers of tissue are consistent with cross-sectional cryo-SEM images and other independent measurements. The extracted resonant frequency and the impedance of each layer explain the origin of the observed resonances. Finally, the elastic modulus of each layer is extracted and analyzed. The presented technique is a unique tool to study (in vivo and in a completely non-invasive way) the ultrasonic, elastic, and viscoelastic properties of layered plant tissues which could lead to a better understanding of the relationship between the tissue microstructure and the tissue function with macroscopic properties and how this may affect water relations.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Surface Density of the Spongy and Palisade Parenchyma Layers of Leaves Extracted From Wideband Ultrasonic Resonance Spectra

  • Alvarez-Arenas, T.E.G.
  • Sancho-Knapik, D.
  • Peguero-Pina, J.J.
  • Gil-Pelegrín, E.
The wide band and air-coupled ultrasonic resonant spectroscopy together with a modified Simulated Annealing metaheuristic algorithm and a 1D layered acoustic-model are used to resolve the structure of plant leaves. In particular, this paper focuses on the extraction of the surface density of the different layers of tissue in leaves having a relatively simple structure. There are three main reasons to select the surface density as the focus of this study: (i) it is a parameter directly extracted by the proposed technique and it requires no further processing, (ii) it is relevant in order to study the dynamic of the water within the different tissues of the leaves and also to study the differential development of the different tissues, and (iii) unlike other parameters provided by this technique (like resonant frequency, impedance, ultrasonic elastic modulus, or ultrasonic damping), this parameter can be easier to understand as it is a direct measure of mass per unit surface. The selection of leaves with a simple structure is justified by the convenience of avoiding an unnecessary complication of the data extraction step. In this work, the technique was applied to determine the surface density of the palisade and spongy parenchyma layers of tissue of Ligustrum lucidum, Vitis vinifera, and Viburnum tinus leaves. The first species was used to study the variation of the surface density at full turgor with the thickness of the leaf, while the two other species were used to study the variation of the surface densities with the variation in the leaf relative water content. Consistency of the results with other conventional measurements (like overall surface density, and cross-section optical and cryo-SEM images) is discussed. The results obtained reveal the potential of this technique; moreover, the technique presents the additional advantage that can be applied in-vivo as it is completely non-invasive, non-destructive, fast, and equipment required is portable.