Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Automatic left ventricle volume calculation with explainability through a deep learning weak-supervision methodology

  • Pérez-Pelegrí, Manuel
  • Moratal, David|||0000-0002-2825-3646
  • Monmeneu, Jose V.
  • López-Lereu, María P.
  • Pérez-Pelegrí, Lucía
  • Maceira, Alicia M.
  • Bodi, Vicente
[EN] Background and objective: Magnetic resonance imaging is the most reliable imaging technique to assess the heart. More specifically there is great importance in the analysis of the left ventricle, as the main pathologies directly affect this region. In order to characterize the left ventricle, it is necessary to extract its volume. In this work we present a neural network architecture that is capable of directly estimating the left ventricle volume in short axis cine Magnetic Resonance Imaging in the end-diastolic frame and provide a segmentation of the region which is the basis of the volume calculation, thus offering explain-ability to the estimated value. Methods: The network was designed to directly target the volumes to estimate, not requiring any labeled segmentation on the images. The network was based on a 3D U-net with extra layers defined in a scan-ning module that learned features like the circularity of the objects and the volumes to estimate in a weakly-supervised manner. The only targets defined were the left ventricle volumes and the circularity of the object detected through the estimation of the pi value derived from its shape. We had access to 397 cases corresponding to 397 different subjects. We randomly selected 98 cases to use as test set. Results: The results show a good match between the real and estimated volumes in the test set, with a mean relative error of 8% and a mean absolute error of 9.12 ml with a Pearson correlation coefficient of 0.95. The derived segmentations obtained by the network achieved Dice coefficients with a mean value of 0.79. Conclusions: The proposed method is capable of obtaining the left ventricle volume biomarker in the end-diastole and offer an explanation of how it obtains the result in the form of a segmentation mask without the need of segmentation labels to train the algorithm, making it a potentially more trustworthy method for clinicians and a way to train neural networks more easily when segmentation labels are not readily available., The authors acknowledge financial support from the Consel-leria d'Educacio, Investigacio, Cultura i Esport, Generalitat Valenciana (grants AEST/2019/037 and AEST/2020/029) , from the Agencia Valenciana de la Innovacion, Generalitat Valenciana (ref. INNCAD00/19/085) , and from the Centro para el Desarrollo Tecnologico Industrial (Programa Eurostars2, actuacion Interempresas Internacional) , Spanish Ministerio de Ciencia, Innovacion y Universidades (ref. CIIP-20192020) .
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Characterization of protons accelerated from a 3 TW table-top laser system

  • Bellido-Millán, Pablo Jesús
  • Lera, Roberto
  • Ruiz-de la Cruz, Alexandro
  • Torres Peiró, Salvador
  • Galán, M.
  • Mur, P.
  • Sánchez, I.
  • Zaffino, R.
  • Soriano Asensi, Antonio
  • Sánchez-Góez, Sebastián
  • Rigla, J.P.
  • Iborra Carreres, Amadeo
  • Hernández Hernández, Liczandro
  • Grau-Ruiz, Daniel
  • Díaz Caballero, Elena
  • Conde-Castellanos, Pablo Eloy
  • Aguilar-Talens, Albert
  • Roso, Luis
  • Seimetz, Michael
  • Vidal San Sebastian, Luis Fernando|||0000-0001-8852-8560
  • F Sánchez
  • Rodríguez-Álvarez, M.J.|||0000-0001-8333-8792
  • Moliner Martínez, Laura
  • González Martínez, Antonio Javier
  • García-Garrigos, Juan José
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
[EN] We report on benchmark tests of a 3 TW/50 fs, table-top laser system specifically developed for proton acceleration with an intrinsic pump rate up to 100 Hz. In two series of single-shot measurements differing in pulse energy and contrast the successful operation of the diode pumped laser is demonstrated. Protons have been accelerated up to 1.6 MeV in interactions of laser pulses focused on aluminium and mylar foils between 0.8 and 25 mu m thickness. Their spectral distributions and maximum energies are consistent with former experiments under similar conditions. These results show the suitability of our system and provide a reference for studies of laser targets at high repetition rate and possible applications., This project has been funded by Centro para el Desarrollo Tecnologico Industrial (CDTI, Spain) within the INNPRONTA program, grant no. IPT-20111027, by EUROSTARS project E9113, and by the Spanish Ministry for Economy and Competitiveness within the Retos-Colaboracion 2015 initiative, ref. RTC-2015-3278-1.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Magnetic Resonance Assessment of Left Ventricular Ejection Fraction at Any Time Post-Infarction for Prediction of Subsequent Events in a Large Multicenter STEMI Registry

  • Gavara-Doñate, Josep|||0000-0002-3483-7066
  • Moratal, David|||0000-0002-2825-3646
  • Marcos-Garces, Victor
  • Lopez-Lereu, Maria P.
  • Monmeneu, José V.
  • Rios-Navarro, César
  • De Dios, Elena
  • Pérez, Nerea
  • Merenciano, Héctor
  • Gabaldon, Ana
  • Cànoves, Joaquim
  • Racugno, Paolo
  • Bonanad, Clara
  • Miñana, Gema
  • Nunez, Julio
  • Nunez, Eduardo
[EN] Background Magnetic resonance imaging (MRI) is the most accurate imaging technique for left ventricular ejection fraction (LVEF) quantification, but as yet the prognostic value of LVEF assessment at any time after ST-segment elevation myocardial infarction (STEMI) for subsequent major adverse cardiac event (MACE) prediction is uncertain. Purpose To explore the prognostic impact of MRI-derived LVEF at any time post-STEMI to predict subsequent MACE (cardiovascular death or re-admission for acute heart failure). Study Type Prospective. Population One thousand thirteen STEMI patients were included in a multicenter registry. Field Strength/Sequence 1.5-T. Balanced steady-state free precession (cine imaging) and segmented inversion recovery steady-state free precession (late gadolinium enhancement) sequences. Assessment Post-infarction MRI-derived LVEF (reduced [r]: <40%; mid-range [mr]: 40%-49%; preserved [p]: >= 50%) was sequentially quantified at 1 week and after >3 months of follow-up. Statistical Tests Multi-state Markov model to determine the prognostic value of each LVEF state (r-, mr- or p-) at any time point assessed to predict subsequent MACE. A P-value During a 6.2-year median follow-up, 105 MACE (10%) were registered. Transitions toward improved LVEF predominated and only r-LVEF (at any time assessed) was significantly related to a higher incidence of subsequent MACE. The observed transitions from r-LVEF, mr-LVEF, and p-LVEF states to MACE were: 15.3%, 6%, and 6.7%, respectively. Regarding the adjusted transition intensity ratios, patients in r-LVEF state were 4.52-fold more likely than those in mr-LVEF state and 5.01-fold more likely than those in p-LVEF state to move to MACE state. Nevertheless, no significant differences were found in transitions from mr-LVEF and p-LVEF states to MACE state (P-value = 0.6). Data Conclusion LVEF is an important MRI index for simple and dynamic post-STEMI risk stratification. Detection of r-LVEF by MRI at any time during follow-up identifies a subset of patients at high risk of subsequent events. Level of Evidence 2 Technical Efficacy Stage 2, This work was supported by "Instituto de Salud Carlos III," "Fondos Europeos de Desarrollo Regional FEDER" (grants PI15/00531, PI17/01836, PI20/00637, and CIBERCV16/11/00486), and "Marato TV3" (grant 20153030-31-32), a grant from the Catalonian Society of Cardiology 2015 and a grant from La Caixa Foundation (HR17-00527). David Moratal and Jose Gavara acknowledge financial support from the "Conselleria d'Educacio, Investigacio, Cultura i Esport, Generalitat Valenciana" (grants AEST/2019/037 and AEST/2020/029), "Agencia Valenciana de la Innovacion, Generalitat Valenciana" (ref. INNCAD00/19/085 and INNCAD/2020/84), and "Centro para el Desarrollo Tecnologico Industrial" (Programa Eurostars-2, actuacion Interempresas Internacional), Spanish "Ministerio de Ciencia, Innovacion y Universidades" (ref. CIIP-20192020).