Pasar al contenido principal

MEJORA DE LA EFICIENCIA ENERGETICA EN EDIFICIOS MEDIANTE EL ALMACENAMIENTO DE ENERGIA TERMICA

ENE2011-28269-C03-03

•
Nombre agencia financiadora Ministerio de Ciencia e Innovación
Acrónimo agencia financiadora MICINN
Programa Programa Nacional de Proyectos de Investigación Fundamental
Subprograma Subprograma de Proyectos de Investigación Fundamental no Orientada
Convocatoria Proyectos I+D
Año convocatoria 2011
Plan Estatal 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Unidad de gestión Subdirección General de Proyectos de Investigación
Centro beneficiario UNIVERSITAT ROVIRA I VIRGILI
Identificador persistente http://dx.doi.org/10.13039/501100004837

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Life cycle assessment of a ventilated facade with PCM in its air chamber

  • Gracia Cuesta, Alvaro de
  • Navarro Farré, Lidia
  • Castell, Albert
  • Boer, Dieter
  • Cabeza, Luisa F.
In the buildings sector, the use of ventilated double skin facades in order to reduce the energy demand and the environmental impact of the building during its operational phase has grown significantly. However, the use of this constructive system could lead to high environmental costs during the manufacturing and dismantling phase of the building. This paper presents a life cycle assessment (LCA) study based on the EcoIndicator 99 of a ventilated facade with PCM in its air chamber. Two cubicles were built in an experimental set-up located in Puigverd de Lleida (Spain), one with this ventilated facade system and the other without. The differences in the electrical energy consumption of the HVAC systems were registered and used to determine the environmental savings produced during the operational phase of each building. The results of the LCA show that considering a lifetime of 50 years, the use of this particular ventilated facade reduces by 7.7% the overall environmental impact of the whole building. It also highlights that the environmental payback of this active system is significantly lower than other systems which use PCM in the building envelopes. The environmental payback of the system is 30 years, which can be reduced to only 6 years if instead steel wood would have been used in the structure., This work was supported by the “Corporacio´n Tecnolo ´gica de Andalucı´a” by means of the project “MECLIDE-Soluciones estructurales con materiales especiales para la climatizacio´n diferida de edificios” with the collaboration of DETEA. The work was partially funded by the Spanish government (ENE2011-28269-C03-03 and ULLE10-4E-1305) and the European Union (COST Action COST TU0802). The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2009 SGR 534).
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Plant cover and floristic composition effect on thermal behaviour of extensive green roofs

  • Bevilacqua, Piero
  • Coma Arpón, Julià
  • Pérez Luque, Gabriel
  • Chocarro, Cristina
  • Juárez Escario, Alejandro
  • Solé Cutrona, Cristian
  • De Simone, Marilena
  • Cabeza, Luisa F.
In the last few years an increasing attention has been paid to efficient energy construction systems in the building sector. Although in this contest extensive green roofs are reported to be very effective and sustainable systems, the fact that the main agents of this systems are living organisms have generated doubts, especially in locations where the development of plants and vegetation can be greatly affected by climate. This study aims to investigate the thermal performances of a 2000 m2 18 particular proprietary extensive green roof system, located on the city of Lleida (Spain), classified as Dry Mediterranean Continental climate. First, plant cover and floristic composition analysis were carried out to evaluate the dynamic of the plant layer over the surface. Then, according to the result of the botanic analysis, summer and winter study in terms of spatial and temporal factors were conducted focusing on the substrate layer, evapotranspiration effect and comparing the different behaviour of the system in low 10%) and high (80%) plant cover conditions. In this extensive green roof, the results showed temporal and spatial changes in floristic composition, with a stable cover of Sedum sp between 20 to 40 %, and a peak of colonizing species in spring and early summer. The increase in vegetation cover appears to have few effects on the above nearby roof environment because of the low moisture level in the substrate layer so that the cooling effect provided by the evapotranspiration does not take place. In addition, the increased presence of vegetation canopy may induce a limitation in substrate night cooling whereas serves as good shield for solar radiation during the day. Finally, the study also reveals the importance of the spatial factor in extensive green roofs, which can lead to not negligible variations on the thermal performance, as well as the floristic composition., The work was partially funded by the Spanish Government (ENE2011-28269-C03-02 and ENE2011-28269-C03-03), in collaboration with Gardeny Science and Technology Park in Lleida (Spain). The authors would like to thank the architect Josep Maria Puigdemasa his provision of information about the renovation project. On the other hand the authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123). Julià Coma wants to thank the Departament d'Universitats, Recerca i Societat de la Informació de la Generalitat de Catalunya for his research fellowship. Furthermore the research was supported by the Italian Ministry of Education, University and Research MIUR.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

On the use of filters to facilitate the post-optimal analysis of the Pareto solutions in multi-objective optimization

  • Antipova, Ekaterina
  • Pozo, C.
  • Guillén Gosálbez, Gonzalo
  • Boer, Dieter
  • Cabeza, Luisa F.
  • Jiménez Esteller, Laureano
Multi-objective optimization (MOO) has emerged recently as a useful technique in the design andplanning of engineering systems because it allows identifying alternatives leading to significant envi-ronmental savings. MOO models typically contain an infinite number of Pareto solutions, from whichdecision-makers should choose the best one according to their preferences. An approach is here pre-sented that identifies and retains for further inspection a reduced set of Pareto solutions showing betteroverall performance. The capabilities of our approach are illustrated through its application to the designof reverse osmosis desalination plants considering simultaneously the unitary production cost and a setof environmental impacts in several damage categories. Our method reduces significantly the number ofPareto points, thereby facilitating the decision-making process in MOO., The authors would like to acknowledge financial support from the Spanish Government(ENE2011-28269-C03-03, ENE2011-22722, DPI2012-37154-C02-02, CTQ2012-37039-C02) and the Catalan Government for the quality accreditation given to their research groups SUSCAPE and GREA (2009 SGR 545, 2009 SGR 534)
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Uncertainty propagation and sensitivity analysis of thermo-physical properties of phase change materials (PCM) in the energy demand calculations of a test cell with passive latent thermal storage

  • Mazo, J.
  • El Badry, A. T.
  • Carreras, J.
  • Delgado, M.
  • Boer, D.
  • Zalba, B.
In this work uncertainty propagation and sensitivity analyses have been applied to a case study of an application where PCM is integrated into the envelope of a test cell. The aim of the study is to quantify the influence of the uncertainties associated with the measurements of the thermo-physical properties of PCM on the results of the annual energy consumption. For this purpose, EnergyPlus has been used for the building energy simulation and a Monte Carlo based method has been chosen for the uncertainty and sensitivity analysis. Considering realistic uncertainty ranges for PCM thermo-physical properties, a significant uncertainty of savings on cooling energy demand has been calculated (approximately 10%). Phase change temperature and thermal conductivity have been identified as the most influential input parameters whereas phase change enthalpy is of secondary importance. A method has been proposed in order to calculate a combination of admissible uncertainties for the input variables that reduces output uncertainty to a required value. The method can be used if input variables and the behaviour of the model comply with certain conditions. For the case study, a maximum tolerance for the error of measurements of phase change temperature and thermal conductivity of ±0.3 °C and ±8% respectively is necessary to reduce the uncertainty of savings on cooling energy demand to 5%
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Life cycle assessment of a ventilated facade with PCM in its air chamber

  • Gracia Cuesta, Alvaro de
  • Navarro Farré, Lidia
  • Castell, Albert
  • Boer, Dieter
  • Cabeza, Luisa F.
In the buildings sector, the use of ventilated double skin facades in order to reduce the energy demand and the environmental impact of the building during its operational phase has grown significantly. However, the use of this constructive system could lead to high environmental costs during the manufacturing and dismantling phase of the building. This paper presents a life cycle assessment (LCA) study based on the EcoIndicator 99 of a ventilated facade with PCM in its air chamber. Two cubicles were built in an experimental set-up located in Puigverd de Lleida (Spain), one with this ventilated facade system and the other without. The differences in the electrical energy consumption of the HVAC systems were registered and used to determine the environmental savings produced during the operational phase of each building. The results of the LCA show that considering a lifetime of 50 years, the use of this particular ventilated facade reduces by 7.7% the overall environmental impact of the whole building. It also highlights that the environmental payback of this active system is significantly lower than other systems which use PCM in the building envelopes. The environmental payback of the system is 30 years, which can be reduced to only 6 years if instead steel wood would have been used in the structure., This work was supported by the “Corporacio´n Tecnolo ´gica de Andalucı´a” by means of the project “MECLIDE-Soluciones estructurales con materiales especiales para la climatizacio´n diferida de edificios” with the collaboration of DETEA. The work was partially funded by the Spanish government (ENE2011-28269-C03-03 and ULLE10-4E-1305) and the European Union (COST Action COST TU0802). The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2009 SGR 534).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Plant cover and floristic composition effect on thermal behaviour of extensive green roofs

  • Bevilacqua, Piero
  • Coma Arpón, Julià
  • Pérez Luque, Gabriel
  • Chocarro, Cristina
  • Juárez Escario, Alejandro
  • Solé Cutrona, Cristian
  • De Simone, Marilena
  • Cabeza, Luisa F.
In the last few years an increasing attention has been paid to efficient energy construction systems in the building sector. Although in this contest extensive green roofs are reported to be very effective and sustainable systems, the fact that the main agents of this systems are living organisms have generated doubts, especially in locations where the development of plants and vegetation can be greatly affected by climate. This study aims to investigate the thermal performances of a 2000 m2 18 particular proprietary extensive green roof system, located on the city of Lleida (Spain), classified as Dry Mediterranean Continental climate. First, plant cover and floristic composition analysis were carried out to evaluate the dynamic of the plant layer over the surface. Then, according to the result of the botanic analysis, summer and winter study in terms of spatial and temporal factors were conducted focusing on the substrate layer, evapotranspiration effect and comparing the different behaviour of the system in low 10%) and high (80%) plant cover conditions. In this extensive green roof, the results showed temporal and spatial changes in floristic composition, with a stable cover of Sedum sp between 20 to 40 %, and a peak of colonizing species in spring and early summer. The increase in vegetation cover appears to have few effects on the above nearby roof environment because of the low moisture level in the substrate layer so that the cooling effect provided by the evapotranspiration does not take place. In addition, the increased presence of vegetation canopy may induce a limitation in substrate night cooling whereas serves as good shield for solar radiation during the day. Finally, the study also reveals the importance of the spatial factor in extensive green roofs, which can lead to not negligible variations on the thermal performance, as well as the floristic composition., The work was partially funded by the Spanish Government (ENE2011-28269-C03-02 and ENE2011-28269-C03-03), in collaboration with Gardeny Science and Technology Park in Lleida (Spain). The authors would like to thank the architect Josep Maria Puigdemasa his provision of information about the renovation project. On the other hand the authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123). Julià Coma wants to thank the Departament d'Universitats, Recerca i Societat de la Informació de la Generalitat de Catalunya for his research fellowship. Furthermore the research was supported by the Italian Ministry of Education, University and Research MIUR.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

On the use of filters to facilitate the post-optimal analysis of the Pareto solutions in multi-objective optimization

  • Antipova, Ekaterina
  • Pozo, C.
  • Guillén Gosálbez, Gonzalo
  • Boer, Dieter
  • Cabeza, Luisa F.
  • Jiménez Esteller, Laureano
Multi-objective optimization (MOO) has emerged recently as a useful technique in the design andplanning of engineering systems because it allows identifying alternatives leading to significant envi-ronmental savings. MOO models typically contain an infinite number of Pareto solutions, from whichdecision-makers should choose the best one according to their preferences. An approach is here pre-sented that identifies and retains for further inspection a reduced set of Pareto solutions showing betteroverall performance. The capabilities of our approach are illustrated through its application to the designof reverse osmosis desalination plants considering simultaneously the unitary production cost and a setof environmental impacts in several damage categories. Our method reduces significantly the number ofPareto points, thereby facilitating the decision-making process in MOO., The authors would like to acknowledge financial support from the Spanish Government(ENE2011-28269-C03-03, ENE2011-22722, DPI2012-37154-C02-02, CTQ2012-37039-C02) and the Catalan Government for the quality accreditation given to their research groups SUSCAPE and GREA (2009 SGR 545, 2009 SGR 534)