Pasar al contenido principal

MEJORA DE LA EFICIENCIA ENERGETICA EN EDIFICIOS MEDIANTE EL ALMACENAMIENTO DE ENERGIA TERMICA

ENE2011-28269-C03-01

•
Nombre agencia financiadora Ministerio de Ciencia e Innovación
Acrónimo agencia financiadora MICINN
Programa Programa Nacional de Proyectos de Investigación Fundamental
Subprograma Subprograma de Proyectos de Investigación Fundamental no Orientada
Convocatoria Proyectos I+D
Año convocatoria 2011
Plan Estatal 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Unidad de gestión Subdirección General de Proyectos de Investigación
Centro beneficiario UNIVERSIDAD DE ZARAGOZA
Identificador persistente http://dx.doi.org/10.13039/501100004837

Resultados relacionados

Resultados totales (Incluyendo duplicados): 29
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Performance characterization of a PCM storage tank

  • López Navarro, Alejandro
  • Biosca Taronger, Javier
  • Corberán Salvador, José Miguel
  • Peñalosa, C.
  • Lázaro, A.
  • Dolado, P.
  • Payá-Herrero, Jorge|||0000-0003-2663-3191
This paper presents the experimental results of a versatile latent heat storage tank capable of working with organic phase-change materials within a temperature range from -10 °C to 100 °C. The tank contains a paraffin with a phase-change temperature between 3 °C and 8 °C. Firstly, this study focuses on explaining the design criteria which were followed to build the tank. Secondly, a full experimental characterization of the performance has been carried out. The enthalpy temperature curve, the specific heat and density have been measured for the tested paraffin. The performance of the tank has been analyzed in terms of the vertical stratification within the PCM, the effectiveness, the reacted fraction and the total heat transfer of the tank. The results indicate that up to 78% of the maximum capacity is reached within 4 h. The performance is mainly controlled by the supply temperature and the effect of the mass flow rate is almost negligible given that all the tests are in laminar flow., The authors from the Polytechnic University of Valencia gratefully acknowledge ACCIONA Infraestructuras for the funding of the LHTS installation. The authors from University of Zaragoza would like to thank the Spanish Government for the partial funding of this work within the framework of research projects ENE2008-06687-C02-02 and ENE2011-28269-C03-01.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Life cycle assessment (LCA) and life cycle energy analysis (LCEA) of buildings and the building sector: A review

  • Cabeza, Luisa F.
  • Rincón, Lídia
  • Vilariño, Virginia
  • Pérez Luque, Gabriel
  • Castell, Albert
This review summarizes and organizes the literature on life cycle assessment (LCA), life cycle energy analysis (LCEA) and life cycle cost analysis (LCCA) studies carried out for environmental evaluation of buildings and building related industry and sector (including construction products, construction systems, buildings, and civil engineering constructions). The review shows that most LCA and LCEA are carried out in what is shown as “exemplary buildings”, that is, buildings that have been designed and constructed as low energy buildings, but there are very few studies on “traditional buildings”, that is, buildings such as those mostly found in our cities. Similarly, most studies are carried out in urban areas, while rural areas are not well represented in the literature. Finally, studies are not equally distributed around the world., The work is partially funded by the Spanish government (ENE2011-28269-C03-01 and ENE2011-28269-C03-02) and the European Union (COST Action TU0802). The authors would like to thank the Catalan Government for the quality accreditation given to their research group GREA (2009 SGR 534).
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Control of a PCM ventilated facade using reinforcement learning techniques

  • Gracia Cuesta, Alvaro de
  • Fernàndez Camon, César
  • Castell, Albert
  • Mateu Piñol, Carles
  • Cabeza, Luisa F.
Artificial intelligence techniques have been successfully applied to control dynamic systems looking for an optimal control. Among those techniques, reinforcement learning has been shown as particularly effective at reducing the dimensionality of some real problems and solving control problems by learning from experience. The use of thermal energy storage active systems in the building sector is identified as suitable option to reduce their energy demand for heating and cooling. However, these systems might be expensive and require appropriate control strategies in order to improve the performance of the building. In this paper a ventilated facade with PCM is controlled using a reinforcement learning algorithm. The ventilated facade uses mechanical ventilation during nighttime to solidify the PCM and releases this cold stored to the inner environment during the peak demand period. It is crucial to decide correctly the schedule of charge and discharge process of the PCM according to the weather and indoor conditions. An experimentally validated numerical model is used to test the performance of the control algorithm under different weather conditions. Important improvements on the energy savings due to the use of control strategies were found and supported by the data under the different tested climatic conditions., The work partially funded by the Spanish government (ENE2011-28269-C03-01, ENE2011-22722 and ULLE10-4E-1305). The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014-SGR-123). The research leading to these results has received funding from the European Union’s Seventh Framework Programme (FP7/2007-2013) under grant agreement #PIRSES-GA-2013-610692 (INNOSTORAGE). Alvaro de Gracia would like to thank Education Ministry of Chile for Grant PMI ANT1201.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Design of a prefabricated concrete slab with PCM inside the hollows

  • Cabeza, Luisa F.
  • Navarro Farré, Lidia
  • Gracia Cuesta, Alvaro de
  • Castell, Albert
  • Álvarez, Servando
In the recent years, the integration of heat storage systems inside building components has been applied for heating and cooling purposes. The implementation of the thermal energy storage inside the building is used to manage and smooth the peak demand. An innovative constructive system including heat storage has been designed to reduce the energy consumption of the HVAC systems, during both heating and cooling periods. It consists of a prefabricated concrete slab with macro-encapsulated PCM inside its hollows. An installation of air ducts allows the air to be forced through the inside of the slab and therefore enhancing the heat exchange with the PCM. The operational mode during summer lies in solidifying the PCM during the night time and using the cold stored as a cooling supply during the day. Moreover, a solar air collector is installed for the winter mode, where the heat from the solar radiation is used to melt the PCM and cover part of the heating demand. The objective of this study is to analyse the benefits of this new system and to quantify its potential in reducing the energy consumed both for heating and cooling., The work partially funded by the Spanish government (ENE2011-28269-C03-01 and ULLE10-4E-1305)
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Energy performance of a ventilated double skin facade with PCM under different climates

  • Gracia Cuesta, Alvaro de
  • Navarro Farré, Lidia
  • Castell, Albert
  • Cabeza, Luisa F.
New policies are being promoted worldwide to reduce the energy consumption for space heating and cooling in the building sector. As a new technology to achieve this objective, phase change material (PCM) panels were installed in a new type of ventilated facade to reduce the consumption for space heating and cooling. During winter, the PCM increases the heat storage capacity of the system exposed to solar radiation, while during summer the system can be used as a cold storage unit or as a night free cooling device. The potential of the system to provide energy benefits in the heating period has been demonstrated experimentally under Mediterranean—continental climate conditions, on the other hand, limited benefits were found during the cooling season. The aim of this study is to determine the potential and suitability of this system to operate for cooling purposes, under different weather conditions around the world. In order to accomplish this objective, an own developed numerical model, based on finite control volume approach, was developed and validated against experimental data. The numerical tool is also used to improve the design and to select the most appropriate schedule of the system under the different analysed weather conditions., This work was supported by the “Corporación Tecnológica de Andalucía” by means of the project “MECLIDE-Soluciones estructurales con materiales especiales para la climatización diferidade edificios” withthe collaborationof DETEA. The workpartially funded by the Spanish government (ENE2011-28269-C03-01 and ULLE10-4E-1305). The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123). The research leading to these results has received funding from the European Union’s Seventh Framework Programme (FP7/2007-2013) under grant agreement no PIRSESGA-2013-610692 (INNOSTORAGE).
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Vertical Greenery Systems (VGS) for energy saving in buildings: A review

  • Pérez Luque, Gabriel
  • Cabeza, Luisa F.
  • Coma Arpón, Julià
  • Martorell, Ingrid
This review paper organizes and summarizes the literature on Vertical Greenery Systems (VGS) when used as passive tool for energy savings in buildings. First, with the information obtained in the reviewed literature some key aspects to consider when working with VGS are clarified, such as the classification systems, the climate influence, the plant species used and the different operating mechanisms. Then, the main conclusions of this literature, sorted by construction system (Green Walls or Green Façades) and climatic situation, are summarized. In general, it can be concluded that VGS provide great potential in reducing energy consumption in buildings, especially in the cooling periods. However, a lack of data on operation during the heating period as well as during the whole year has been found. On the other hand, results show that the investigations of VGS are not equally distributed around the world, being basically concentrated in Europe and Asia. Moreover, the review concludes that some aspects must be studied in depth, such as which species are the most suitable for each climate, influence on energy savings of the façade orientation, foliage thickness, presence of air layers, and finally, substrate layer composition and thickness in the case of green walls., The work was partially funded by the Spanish Government (ENE2011-28269-C03-01 and ENE2011-28269-C03-02) and from the European Union's Seventh Framework Programme(FP7/2007– 2013) under Grant agreement no.PIRSES-GA-2013–610692 (INNOSTORAGE).
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Unconventional experimental technologies available for phase change materials (PCM) characterization. Part 1. Thermophysical properties

  • Cabeza, Luisa F.
  • Barreneche Güerisoli, Camila
  • Martorell, Ingrid
  • Miró, Laia
  • Sari-Bey, Sana
  • Fois, Magali
  • Paksoy, Halime Ö.
  • Sahan, Nurten
  • Weber, Robert
  • Constantinescu, Mariaella
  • Anghel, Elena Maria
  • Malikova, Marta
  • Krupa, Igor
  • Delgado, Mónica
  • Dolado, Pablo
  • Furmanski, Piotr
  • Jaworski, Maciej
  • Haussmann, Thomas
  • Gschwander, Stefan
  • Fernández Renna, Ana Inés
The use of thermal energy storage by phase change materials (PCM) is increasing in interest for building applications. For the deployment of the technology, appropriate characterization of PCM and hybrid PCM is essential, but it is not always possible to carry it out with conventional equipment, mainly due to the sample size. This paper shows equipment developed in different research centers and universities to analyze thermophysical properties, such as specific heat, latent heat and melting temperature, and thermal conductivity and diffusivity of PCM and hybrid PCM materials., The work is partially funded by the European Union (COST Action COST TU0802), the Spanish government (ENE2011-28269-C03-01, ENE2011-28269-C03-02 and ENE2011- 22722), TUBITAK (project 110M032), and by Qatar National Foundation through the NPRP No.: 4-465-2-173. The authors would like to thank the Catalan Government for the quality accreditation given to the research group GREA (2009 SGR 534) and their research group DIOPMA (2009 SGR 645), both in Spain. Laia Miró would like to thank the Spanish Government for her research fellowship (BES-2012-051861).
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Experimental evaluation of a concrete core slab with phase change materials for cooling purposes

  • Navarro Farré, Lidia
  • Gracia Cuesta, Alvaro de
  • Castell, Albert
  • Cabeza, Luisa F.
Due to the high amount of energy consumed by the building sector, efforts need to focus not only on improving the building envelope but also on enhancing the energy efficiency of HVAC systems. In this study, an innovative technology for cooling application in buildings is evaluated. A prefabricated concrete slab incorporating phase change material (PCM) was used as internal separation in the active slab cubicle. The incorporated PCM is paraffin macro-encapsulated in aluminium tubes. The target is to use the internal slab as storage unit and as an active cooling supply to replace totally or partially conventional HVAC systems. The operational mode consists of solidifying the PCM with the outside cold air (below solidification temperature) during the night time for covering a later cooling demand. Experimental analysis shows the energy performance of the technology, as well as a comparison with a conventional cooling system., This work was supported by the “Corporación Tecnológica de Andalucía” by means of the project “MECLIDE-Soluciones estructurales con materiales especiales para la climatización diferida de edificios” with the collaboration of DETEA. The work partially funded by the Spanish Government (ENE2011-28269-C03-01 and ULLE10-4E-1305). The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123) and the city hall of Puigverd de Lleida. The research leading to these results has received funding from the European Union's Seventh Framework Programme (FP7/2007-2013) under grant agreement n° PIRSES-GA-2013-610692 (INNOSTORAGE). Alvaro de Gracia would like to thank Education Ministry of Chile for Grant PMI ANT1201.
Repositori Obert UdL
Publicación Artículo científico (JournalArticle)

Physicochemical and thermal study of a MPCM of PMMA shell and paraffin wax as a core

  • Giro-Paloma, Jessica
  • Barreneche Güerisoli, Camila
  • Delgado, Mónica
  • Martínez, Mònica
  • Fernández Renna, Ana Inés
  • Cabeza, Luisa F.
The present work studies a Phase Change Slurry (PCS) as a proposed Thermal Energy Storage (TES) medium. Microencapsulation is an advanced technology to implement PCMs (Phase Change Material) avoiding leakage from building materials. The morphology and physicochemical properties of this Microencapsulated Phase Change Material (MPCM) sample were analyzed using some analytical techniques like Scanning Electron Microscopy (SEM), Infrared Spectroscopy (FT-IR), Thermogravimetrical Analysis (TGA), Differential Scanning Calorimeter (DSC), and Atomic Force Microscopy (AFM). The results showed that Micronal® DS 5007 is a suitable candidate to be used as slurry in active systems due to their studied mechanical properties., The work is partially funded by the Spanish government (ENE2011-28269-C03-02, ENE2011-22722, and ENE2011-28269-C03-01). The authors would like to thank the Catalan Government for the quality accreditation given to their research group GREA (2009 SGR 534) and research group DIOPMA (2009 SGR 645).
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Physicochemical and thermal study of a MPCM of PMMA shell and paraffin wax as a core

  • Giro-Paloma, J.
  • Barreneche, C.
  • Delgado, M.
  • Martínez, M.
  • Fernández, A.I.
  • Cabeza, L.F.
The present work studies a Phase Change Slurry (PCS) as a proposed Thermal Energy Storage (TES) medium. Microencapsulation is an advanced technology to implement PCMs (Phase Change Material) avoiding leakage from building materials. The morphology and physicochemical properties of this Microencapsulated Phase Change Material (MPCM) sample were analyzed using some analytical techniques like Scanning Electron Microscopy (SEM), Infrared Spectroscopy (FT-IR), Thermogravimetrical Analysis (TGA), Differential Scanning Calorimeter (DSC), and Atomic Force Microscopy (AFM). The results showed that Micronal® DS 5007 is a suitable candidate to be used as slurry in active systems due to their studied mechanical properties.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

An approach to the integrated design of PCM-air heat exchangers based on numerical simulation: a solar cooling case study

  • Dolado Bielsa, Pablo
  • Lázaro Fernández, Ana
  • Delgado Gracia, Mónica
  • Peñalosa García, Conchita
  • Mazo Olarte, Javier
  • Marín Herrero, José María
  • Zalba Nonay, Belén
A novel technique of design of experiments applied to numerical simulations is proposed in this paper as a methodology for the sizing and design of thermal storage equipment integrated in any specific application. The technique is carried out through the response surfaces in order to limit the number of simulation runs required to achieve an appropriate solution. Thus, there are significant savings on the time spent on the design as well as a potential cost saving on the experimentation if similarity relationships between the prototype and the model are met. The technique is applied here to a previously developed and validated numerical model that simulates the thermal behavior of a phase change material-air heat exchanger. The incorporation of the thermal energy storage unit is analyzed in the case of a solar cooling application, improving the system coefficient of performance. The economic viability is mainly conditioned by the price of the macroencapsulated phase change material.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

IEA SHC Task 42 / ECES Annex 29 - Working Group B: Applications of Compact Thermal Energy Storage

  • Van Helden, W
  • Yamaha, M
  • Rathgeber, C
  • Hauer, A
  • Huaylla, F
  • Le Pierrès, N
  • Stutz, B
  • Mette, B
  • Dolado, P
  • Lazaro, A
  • Mazo, J
  • Dannemand, M
  • Furbo, S
  • Campos-Celador, A
  • , Diarce, G
  • Cuypers, R
  • König-Haagen, A
  • Höhlein, S
  • Brüggemann, D
  • Fumey, B
  • Weber, R
  • Köll, R
  • Wagner, W
  • Daguenet-Frick, X
  • Gantenbein, P
  • Kuznik, F
The IEA joint Task 42 / Annex 29 is aimed at developing compact thermal energy storage materials and systems. In Working Group B, experts are working on the development of compact thermal energy storage applications, in the areas cooling, domestic heating and hot water and industry. The majority of application projects were in the field of room heating and domestic hot water. In this article, an overview is given of a large number of applications. The storage technologies used in the applications are latent heat storage, open and closed solid sorption, liquid sorption and salt hydrates and composites thereof. On a broad front, a lot of progress was made in the development of components and systems, providing knowledge and experience regarding the design, numerical modeling, building, testing and economical assessing of components and storage systems. Most important findings are that the interaction of storage materials with the materials of components can be deciding for the technical feasibility, that a number of components, like reactor, heat exchangers and evaporators are less understood than initially thought and need more development, that the inclusion of storage materials in systems generate new challenges like the occurrence of non-condensable gases and thermo-mechanical effects and that standardized and simplified system approaches are needed.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

IEA SHC Task 42 / ECES Annex 29 - A Simple Tool for the Economic Evaluation of Thermal Energy Storages

  • Rathgeber, C
  • Hiebler, S
  • Lävemann, E
  • Dolado, P
  • Lazaro, A
  • Gasia, J
  • De Gracia, A
  • Miró, L
  • Cabeza, L.F
  • König-Haagen, A
  • Brüggemann, D
  • Campos-Celador, Á
  • Franquet, E
  • Fumey, B
  • Dannemand, M
  • Badenhop, T
  • Diriken, J.j
  • Nielsen, J.E.
  • Hauer, A
Within the framework of IEA SHC Task 42 / ECES Annex 29, a simple tool for the economic evaluation of thermal energy storages has been developed and tested on various existing storages. On that account, the storage capacity costs (costs per installed storage capacity) of thermal energy storages have been evaluated via a Top-down and a Bottom-up approach. The Top-down approach follows the assumption that the costs of energy supplied by the storage should not exceed the costs of energy from the market. The maximum acceptable storage capacity costs depend on the interest rate assigned to the capital costs, the intended payback period of the user class (e.g. industry or building), the reference energy costs, and the annual number of storage cycles. The Bottom-up approach focuses on the realised storage capacity costs of existing storages. The economic evaluation via Top-down and Bottom-up approach is a valuable tool to make a rough estimate of the economic viability of an energy storage for a specific application. An important finding is that the annual number of storage cycles has the largest influence on the cost effectiveness. At present and with respect to the investigated storages, seasonal heat storage is only economical via large sensible hot water storages. Contrary, if the annual number of storage cycles is sufficiently high, all thermal energy storage technologies can become competitive.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A theoretical study on the accuracy of the T-history method for enthalpy-temperature curve measurement: Analysis of the influence of thermal gradients inside T-history samples

  • Mazo, J.
  • Delgado, M.
  • Lázaro, A.
  • Dolado, P.
  • Peñalosa, C.
  • Marín, J.M.
  • Zalba, B.
The present work analyses the effect of radial thermal gradients inside T-history samples on the enthalpy temperature curve measurement. A conduction heat transfer model has been utilized for this purpose. Some expressions have been obtained that relate the main dimensionless numbers of the experiments with the deviations in specific heat capacity, phase change enthalpy and phase change temperature estimations. Although these relations can only be strictly applied to solid materials (e.g. measurements of shape stabilized phase change materials), they can provide some useful and conservative bounds for the deviations of the T-history method. Biot numbers emerge as the most relevant dimensionless parameters in the accuracy of the specific heat capacity and phase change enthalpy estimation whereas this model predicts a negligible influence of the temperature levels used for the experiments or the Stefan number.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Porosity and density measurements of sodium acetate trihydrate for thermal energy storage

  • Dannemand, Mark
  • Delgado, Monica
  • Lazaro, Ana
  • Penalosa, Conchita
  • Gundlach, Carsten
  • Trinderup, Camilla
  • Johansen, Jakob Berg
  • Moser, Christoph
  • Schranzhofer, Hermann
  • Furbo, Simon
Sodium acetate trihydrate (SAT) can be used as phase change material in latent heat storage with or without utilizing supercooling. The change of density from liquid to solid state leads to formation of cavities inside the bulk SAT during solidification. Samples of SAT which had solidified from supercooled state at ambient temperature and samples which had solidified with a minimal degree supercooled were investigated. The temperature dependent densities of liquid and the two types of solid SAT were measured with a density meter and a thermomechanical analyzer. The cavities formed inside samples of solid SAT, which had solidified after a high or minimal degree of supercooling, were investigated by X-ray scanning and computer tomography. The apparent density of solid SAT depended on whether it solidified from a supercooled state or not. A sample which solidified from a supercooled liquid contained 15% cavities and had a density of 1.26¿g/cm3 at 25¿°C. SAT which had solidified with minimal supercooling contained 9% cavities and had a density of 1.34¿g/cm3 at 25¿°C. The apparent densities of the solid SAT samples were significant lower than the value of solid SAT reported in literature of 1.45¿g/cm3. The density of liquid and supercooled SAT with extra water was also determined at different temperatures.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Evaluation of the suitability of different calorimetric methods to determine the enthalpy-temperature curve of granular PCM composites

  • Mazo, Javier
  • Delgado, Mónica
  • Peñalosa, Conchita
  • Dolado, Pablo
  • Miranda, Inés
  • Lázaro, Ana
  • Marín, José María
  • Zalba, Belén
The present research has analyzed the complementarity of different measuring methodologies when characterizing the phase changing behaviour of a granular PCM composite (GPCC) through a comparison of their results. Specifically, the enthalpy variation of the GR31 product manufactured by Rubitherm has been measured by using: (1) An energy balance calculation of an air stream flowing through a GPCC packed bed; (2) Differential Scanning Calorimetry; (3) the T-history method. The main purpose of this study was to evaluate the suitability of these methods for the enthalpy-temperature curve determination of GPCC. The energy balance setup gave an accurate measurement of the enthalpy variation within a sufficiently high temperature interval. Obtaining a representative sample was not a problem using this method, in contrast to the DSC which requires a greater number of tests to obtain an average value representative of the packed bed. However, the energy balance method does not enable the direct determination of the enthalpy-temperature curve. The T-history methodology allows the enthalpy to be determined based on temperature while the representativeness problem of the DSC is avoided due to the higher sample volume. Nevertheless, the sample must be altered, crushed and subsequently compacted to reduce the effects of the thermal resistances provoked by the void spaces being filled by air. This comparison has shown that there is no single valid methodology for characterizing the phase changing behaviour of PCM granules.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Experimental analysis of the influence of microcapsule mass fraction on the thermal and rheological behavior of a PCM slurry

  • Delgado,M.
  • Lázaro,A.
  • Peñalosa,C.
  • Zalba,B .
A microencapsulated PCM (Phase Change Material) slurry with three different PCM mass fractions (14, 20 and 30%) has been analyzed. The present study investigates the influence of the PCM microcapsule mass fraction on the thermal and rheological characterization. Specifically, the EnthalpyeTemperature curves, the Thermal ConductivityeTemperature curves and the ViscosityeShear rate curves have been determined In addition, the physical stability under thermo-mechanical cycles has also been studied, as well as the heat transfer phenomenon and the fluid mechanics. The results have shown an enhancement in the heat transfer phenomenon, the slurry with 20% PCM microcapsules being the best option for use as a heat transfer fluid. Rupture of the PCM microcapsules was only observed for the slurry with 30% PCM microcapsules, after being pumped during three weeks and having experienced 10,000 solidification emelting cycles.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Experimental analysis of a low cost phase change material emulsion for its use as thermal storage system

  • Delgado, M.
  • Lázaro, A.
  • Mazo, J.
  • Peñalosa, C.
  • Dolado, P.
  • Zalba, B.
A 46 l commercial tank with a helical coil heat exchanger and containing a low cost phase change material emulsion has been experimentally analyzed as a thermal energy storage system in terms of volumetric energy density and heat transfer rate, for its subsequent comparison with other thermal energy storage systems. This phase change material emulsion shows a phase change temperature range between 30 and 50°C, its solids content is about 60% with an average particle size of 1 µm. The low cost phase change material emulsion shows a thermal storage capacity by mass 50% higher than water and an increase in viscosity up to 2-5 orders of magnitude. The results have shown that the global heat transfer coefficient of the phase change material emulsion tank is around 2-6 times higher than for conventional latent systems previously analyzed in literature, although 5 times lower than if it contains water. The phase change material emulsion tank presents an energy density 34% higher than the water tank, which makes it a promising solution. Measures to improve its performance are also studied in this work.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Uncertainty propagation and sensitivity analysis of thermo-physical properties of phase change materials (PCM) in the energy demand calculations of a test cell with passive latent thermal storage

  • Mazo, J.
  • El Badry, A. T.
  • Carreras, J.
  • Delgado, M.
  • Boer, D.
  • Zalba, B.
In this work uncertainty propagation and sensitivity analyses have been applied to a case study of an application where PCM is integrated into the envelope of a test cell. The aim of the study is to quantify the influence of the uncertainties associated with the measurements of the thermo-physical properties of PCM on the results of the annual energy consumption. For this purpose, EnergyPlus has been used for the building energy simulation and a Monte Carlo based method has been chosen for the uncertainty and sensitivity analysis. Considering realistic uncertainty ranges for PCM thermo-physical properties, a significant uncertainty of savings on cooling energy demand has been calculated (approximately 10%). Phase change temperature and thermal conductivity have been identified as the most influential input parameters whereas phase change enthalpy is of secondary importance. A method has been proposed in order to calculate a combination of admissible uncertainties for the input variables that reduces output uncertainty to a required value. The method can be used if input variables and the behaviour of the model comply with certain conditions. For the case study, a maximum tolerance for the error of measurements of phase change temperature and thermal conductivity of ±0.3 °C and ±8% respectively is necessary to reduce the uncertainty of savings on cooling energy demand to 5%
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Unconventional experimental technologies available for phase change materials (PCM) characterization. Part 1. Thermophysical properties

  • Cabeza, L. F.
  • Barreneche, C.
  • Martorell, I.
  • Miró, L.
  • Sari-Bey, S.
  • Fois, M.
  • Paksoy, H. O.
  • Sahan, N.
  • Weber, R.
  • Constantinescu, M.
  • Anghel, E. M.
  • Malikova, M.
  • Krupa, I.
  • Delgado, M.
  • Dolado, P.
  • Furmanski, P.
  • Jaworski, M.
  • Haussmann, T.
  • Gschwander, S.
  • Fernández, A. I.
The use of thermal energy storage by phase change materials (PCM) is increasing in interest for building applications. For the deployment of the technology, appropriate characterization of PCM and hybrid PCM is essential, but it is not always possible to carry it out with conventional equipment, mainly due to the sample size. This paper shows equipment developed in different research centers and universities to analyze thermophysical properties, such as specific heat, latent heat and melting temperature, and thermal conductivity and diffusivity of PCM and hybrid PCM materials
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Analysis of the physical stability of PCM slurries

  • Delgado, M.
  • Lázaro, A.
  • Peñalosa, C.
  • Mazo, J.
  • Zalba, B.
Microencapsulated phase change material slurry (mPCM slurry) is a latent heat storage fluid in which the PCM microparticles have been dispersed in water. One of the main issues to be tackled is its lack of physical stability, since stratification problems tend to occur. Generally, an unstabilization process in PCM slurries can take weeks or even months. To predict the physical stability of PCM slurries without having to wait so long, a methodology well known in the food and pharmaceutical fields has been applied. This methodology basically consists of measuring samples with a rheometer in oscillatory mode. These measurements can be related to visually obtained measurements of the unstabilization process of creaming, specifically with the creaming percentage over time. From the frequency sweeps accomplished, an exponential relationship between the creaming percentage and the elastic module of the PCM slurries have been obtained. From the strain sweeps, the cohesive energies of the PCM slurries have been calculated and related to the creaming percentage, observing a linear relationship. In this way, the dominant parameters in the unstabilization process have been obtained which manufacturers can modify in order to improve the physical stability of PCM slurries.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Design of a prefabricated concrete slab with PCM inside the hollows

  • Cabeza, Luisa F.
  • Navarro Farré, Lidia
  • Gracia Cuesta, Alvaro de
  • Castell, Albert
  • Álvarez, Servando
In the recent years, the integration of heat storage systems inside building components has been applied for heating and cooling purposes. The implementation of the thermal energy storage inside the building is used to manage and smooth the peak demand. An innovative constructive system including heat storage has been designed to reduce the energy consumption of the HVAC systems, during both heating and cooling periods. It consists of a prefabricated concrete slab with macro-encapsulated PCM inside its hollows. An installation of air ducts allows the air to be forced through the inside of the slab and therefore enhancing the heat exchange with the PCM. The operational mode during summer lies in solidifying the PCM during the night time and using the cold stored as a cooling supply during the day. Moreover, a solar air collector is installed for the winter mode, where the heat from the solar radiation is used to melt the PCM and cover part of the heating demand. The objective of this study is to analyse the benefits of this new system and to quantify its potential in reducing the energy consumed both for heating and cooling., The work partially funded by the Spanish government (ENE2011-28269-C03-01 and ULLE10-4E-1305)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Unconventional experimental technologies available for phase change materials (PCM) characterization. Part 1. Thermophysical properties

  • Cabeza, Luisa F.
  • Barreneche Güerisoli, Camila
  • Martorell, Ingrid
  • Miró, Laia
  • Sari-Bey, Sana
  • Fois, Magali
  • Paksoy, Halime Ö.
  • Sahan, Nurten
  • Weber, Robert
  • Constantinescu, Mariaella
  • Anghel, Elena Maria
  • Malikova, Marta
  • Krupa, Igor
  • Delgado, Mónica
  • Dolado, Pablo
  • Furmanski, Piotr
  • Jaworski, Maciej
  • Haussmann, Thomas
  • Gschwander, Stefan
  • Fernández Renna, Ana Inés
The use of thermal energy storage by phase change materials (PCM) is increasing in interest for building applications. For the deployment of the technology, appropriate characterization of PCM and hybrid PCM is essential, but it is not always possible to carry it out with conventional equipment, mainly due to the sample size. This paper shows equipment developed in different research centers and universities to analyze thermophysical properties, such as specific heat, latent heat and melting temperature, and thermal conductivity and diffusivity of PCM and hybrid PCM materials., The work is partially funded by the European Union (COST Action COST TU0802), the Spanish government (ENE2011-28269-C03-01, ENE2011-28269-C03-02 and ENE2011- 22722), TUBITAK (project 110M032), and by Qatar National Foundation through the NPRP No.: 4-465-2-173. The authors would like to thank the Catalan Government for the quality accreditation given to the research group GREA (2009 SGR 534) and their research group DIOPMA (2009 SGR 645), both in Spain. Laia Miró would like to thank the Spanish Government for her research fellowship (BES-2012-051861).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Life cycle assessment (LCA) and life cycle energy analysis (LCEA) of buildings and the building sector: A review

  • Cabeza, Luisa F.
  • Rincón, Lídia
  • Vilariño, Virginia
  • Pérez Luque, Gabriel
  • Castell, Albert
This review summarizes and organizes the literature on life cycle assessment (LCA), life cycle energy analysis (LCEA) and life cycle cost analysis (LCCA) studies carried out for environmental evaluation of buildings and building related industry and sector (including construction products, construction systems, buildings, and civil engineering constructions). The review shows that most LCA and LCEA are carried out in what is shown as “exemplary buildings”, that is, buildings that have been designed and constructed as low energy buildings, but there are very few studies on “traditional buildings”, that is, buildings such as those mostly found in our cities. Similarly, most studies are carried out in urban areas, while rural areas are not well represented in the literature. Finally, studies are not equally distributed around the world., The work is partially funded by the Spanish government (ENE2011-28269-C03-01 and ENE2011-28269-C03-02) and the European Union (COST Action TU0802). The authors would like to thank the Catalan Government for the quality accreditation given to their research group GREA (2009 SGR 534).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Control of a PCM ventilated facade using reinforcement learning techniques

  • Gracia Cuesta, Alvaro de
  • Fernàndez Camon, César
  • Castell, Albert
  • Mateu Piñol, Carles
  • Cabeza, Luisa F.
Artificial intelligence techniques have been successfully applied to control dynamic systems looking for an optimal control. Among those techniques, reinforcement learning has been shown as particularly effective at reducing the dimensionality of some real problems and solving control problems by learning from experience. The use of thermal energy storage active systems in the building sector is identified as suitable option to reduce their energy demand for heating and cooling. However, these systems might be expensive and require appropriate control strategies in order to improve the performance of the building. In this paper a ventilated facade with PCM is controlled using a reinforcement learning algorithm. The ventilated facade uses mechanical ventilation during nighttime to solidify the PCM and releases this cold stored to the inner environment during the peak demand period. It is crucial to decide correctly the schedule of charge and discharge process of the PCM according to the weather and indoor conditions. An experimentally validated numerical model is used to test the performance of the control algorithm under different weather conditions. Important improvements on the energy savings due to the use of control strategies were found and supported by the data under the different tested climatic conditions., The work partially funded by the Spanish government (ENE2011-28269-C03-01, ENE2011-22722 and ULLE10-4E-1305). The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014-SGR-123). The research leading to these results has received funding from the European Union’s Seventh Framework Programme (FP7/2007-2013) under grant agreement #PIRSES-GA-2013-610692 (INNOSTORAGE). Alvaro de Gracia would like to thank Education Ministry of Chile for Grant PMI ANT1201.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Energy performance of a ventilated double skin facade with PCM under different climates

  • Gracia Cuesta, Alvaro de
  • Navarro Farré, Lidia
  • Castell, Albert
  • Cabeza, Luisa F.
New policies are being promoted worldwide to reduce the energy consumption for space heating and cooling in the building sector. As a new technology to achieve this objective, phase change material (PCM) panels were installed in a new type of ventilated facade to reduce the consumption for space heating and cooling. During winter, the PCM increases the heat storage capacity of the system exposed to solar radiation, while during summer the system can be used as a cold storage unit or as a night free cooling device. The potential of the system to provide energy benefits in the heating period has been demonstrated experimentally under Mediterranean—continental climate conditions, on the other hand, limited benefits were found during the cooling season. The aim of this study is to determine the potential and suitability of this system to operate for cooling purposes, under different weather conditions around the world. In order to accomplish this objective, an own developed numerical model, based on finite control volume approach, was developed and validated against experimental data. The numerical tool is also used to improve the design and to select the most appropriate schedule of the system under the different analysed weather conditions., This work was supported by the “Corporación Tecnológica de Andalucía” by means of the project “MECLIDE-Soluciones estructurales con materiales especiales para la climatización diferidade edificios” withthe collaborationof DETEA. The workpartially funded by the Spanish government (ENE2011-28269-C03-01 and ULLE10-4E-1305). The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123). The research leading to these results has received funding from the European Union’s Seventh Framework Programme (FP7/2007-2013) under grant agreement no PIRSESGA-2013-610692 (INNOSTORAGE).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Vertical Greenery Systems (VGS) for energy saving in buildings: A review

  • Pérez Luque, Gabriel
  • Cabeza, Luisa F.
  • Coma Arpón, Julià
  • Martorell, Ingrid
This review paper organizes and summarizes the literature on Vertical Greenery Systems (VGS) when used as passive tool for energy savings in buildings. First, with the information obtained in the reviewed literature some key aspects to consider when working with VGS are clarified, such as the classification systems, the climate influence, the plant species used and the different operating mechanisms. Then, the main conclusions of this literature, sorted by construction system (Green Walls or Green Façades) and climatic situation, are summarized. In general, it can be concluded that VGS provide great potential in reducing energy consumption in buildings, especially in the cooling periods. However, a lack of data on operation during the heating period as well as during the whole year has been found. On the other hand, results show that the investigations of VGS are not equally distributed around the world, being basically concentrated in Europe and Asia. Moreover, the review concludes that some aspects must be studied in depth, such as which species are the most suitable for each climate, influence on energy savings of the façade orientation, foliage thickness, presence of air layers, and finally, substrate layer composition and thickness in the case of green walls., The work was partially funded by the Spanish Government (ENE2011-28269-C03-01 and ENE2011-28269-C03-02) and from the European Union's Seventh Framework Programme(FP7/2007– 2013) under Grant agreement no.PIRSES-GA-2013–610692 (INNOSTORAGE).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Physicochemical and thermal study of a MPCM of PMMA shell and paraffin wax as a core

  • Giro-Paloma, Jessica
  • Barreneche Güerisoli, Camila
  • Delgado, Mónica
  • Martínez, Mònica
  • Fernández Renna, Ana Inés
  • Cabeza, Luisa F.
The present work studies a Phase Change Slurry (PCS) as a proposed Thermal Energy Storage (TES) medium. Microencapsulation is an advanced technology to implement PCMs (Phase Change Material) avoiding leakage from building materials. The morphology and physicochemical properties of this Microencapsulated Phase Change Material (MPCM) sample were analyzed using some analytical techniques like Scanning Electron Microscopy (SEM), Infrared Spectroscopy (FT-IR), Thermogravimetrical Analysis (TGA), Differential Scanning Calorimeter (DSC), and Atomic Force Microscopy (AFM). The results showed that Micronal® DS 5007 is a suitable candidate to be used as slurry in active systems due to their studied mechanical properties., The work is partially funded by the Spanish government (ENE2011-28269-C03-02, ENE2011-22722, and ENE2011-28269-C03-01). The authors would like to thank the Catalan Government for the quality accreditation given to their research group GREA (2009 SGR 534) and research group DIOPMA (2009 SGR 645).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Experimental evaluation of a concrete core slab with phase change materials for cooling purposes

  • Navarro Farré, Lidia
  • Gracia Cuesta, Alvaro de
  • Castell, Albert
  • Cabeza, Luisa F.
Due to the high amount of energy consumed by the building sector, efforts need to focus not only on improving the building envelope but also on enhancing the energy efficiency of HVAC systems. In this study, an innovative technology for cooling application in buildings is evaluated. A prefabricated concrete slab incorporating phase change material (PCM) was used as internal separation in the active slab cubicle. The incorporated PCM is paraffin macro-encapsulated in aluminium tubes. The target is to use the internal slab as storage unit and as an active cooling supply to replace totally or partially conventional HVAC systems. The operational mode consists of solidifying the PCM with the outside cold air (below solidification temperature) during the night time for covering a later cooling demand. Experimental analysis shows the energy performance of the technology, as well as a comparison with a conventional cooling system., This work was supported by the “Corporación Tecnológica de Andalucía” by means of the project “MECLIDE-Soluciones estructurales con materiales especiales para la climatización diferida de edificios” with the collaboration of DETEA. The work partially funded by the Spanish Government (ENE2011-28269-C03-01 and ULLE10-4E-1305). The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2014 SGR 123) and the city hall of Puigverd de Lleida. The research leading to these results has received funding from the European Union's Seventh Framework Programme (FP7/2007-2013) under grant agreement n° PIRSES-GA-2013-610692 (INNOSTORAGE). Alvaro de Gracia would like to thank Education Ministry of Chile for Grant PMI ANT1201.