Using microwave near-field reflection measurements as a non-destructive test to determine water penetration depth of concrete
A non-destructive version of a standard test for concrete permeability has been demonstrated. The
method is based on water penetration depth estimation from near-field microwave measurements using
an open-ended rectangular waveguide. In particular, water penetration is determined from the
differential measurement of reflection coefficient in the S-band before and after injection of water
under pressure. Experimental results show a good correlation between the standard destructive test and
the new method. Microwave measurements simplify the standard test avoiding the need of drilling out a
sample from the structure and thus reducing both the cost and time needed in the analysis.
& 2015 Elsevier Ltd. All rights reserved., Andres F. Castro would like to acknowledge the financial support (FI-015-13 and F1-015A-13) received from the MICITT (Ministerio de Ciencia, Tecnologia y Telecomunicaciones) and CONICIT (Consejo Nacional para Investigaciones Cientificas y Tecnologicas), both entities of the Costa Rican government.