Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Methodology for the Identification of Dust Accumulation Levels in Photovoltaic Panels Based in Heuristic-Statistical Techniques

  • Perez-Anaya, Eduardo
  • Elvira-Ortiz, David A.
  • Osornio-Rios, Roque A.
  • J. Antonino-Daviu|||0000-0003-1898-2228
[EN] The use of renewable energies is increasing around the world in order to deal with the environmental and economic problems related with conventional generation. In this sense, photovoltaic generation is one of the most promising technologies because of the high availability of sunlight, the easiness of maintenance, and the reduction in the costs of installation and production. However, photovoltaic panels are elements that must be located outside in order to receive the sun radiation and transform it into electricity. Therefore, they are exposed to the weather conditions and many environmental factors that can negatively affect the output delivered by the system. One of the most common issues related to the outside location is the dust accumulation in the surface of the panels. The dust particles obstruct the passage of the sunlight, reducing the efficiency of the generation process and making the system prone to experimental long-term faults. Thus, it is necessary to develop techniques that allow us to assess the level of dust accumulation in the panel surface in order to schedule a proper maintenance and avoid losses associated with the reduction of the delivered power and unexpected faults. In this work, we propose a methodology that uses a machine learning approach to estimate different levels of dust accumulation in photovoltaic panels. The developed method takes the voltage, current, temperature, and sun radiance as inputs to perform a statistical feature extraction that describes the behavior of the photovoltaic system under different dust conditions. In order to retain only the relevant information, a genetic algorithm works along with the principal component analysis technique to perform an optimal feature selection. Next, the linear discrimination analysis is carried out using the optimized dataset to reduce the problem dimensionality, and a multi-layer perceptron neural network is implemented as a classifier for discriminating among three different conditions: clean surface, slight dust accumulation, and severe dust accumulation. The proposed methodology is implemented using real signals from a photovoltaic installation, proving to be effective not only to determine if a dust accumulation condition is present but also when maintenance actions must be performed. Moreover, the results demonstrate that the accuracy of the proposed method is always above 94%., This work was supported in part by the CONACYT scholarship under grant 1078505 and by FONDEC-UAQ 2020 FIN202011 project.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Power Quality Monitoring Strategy Based on an Optimized Multi-domain Feature Selection for the Detection and Classification of Disturbances in Wind Generators

  • Elvira-Ortiz, David A.
  • Saucedo-Dorantes, Juan J.
  • Osornio-Rios, Roque A.
  • Morinigo-Sotelo, Daniel
  • J. Antonino-Daviu|||0000-0003-1898-2228
[EN] Wind generation is an essential power supply in the last time, as a renewable option. These wind generators are integrated with electrical machines that require correct functionality. However, the increasing use of non-linear loads introduces undesired disturbances that may compromise the integrity of the electrical machines inside the wind generator. Therefore, this work proposes a 5-step methodology for power quality disturbance detection in grids with injection of wind farm energy. First, a database with synthetic signals is generated to be used in the training process. Then, a multi-domain feature estimation is carried out. To reduce the problem dimensionality, the features that provide redundant information are eliminated through an optimized feature selec-tion performed by means of a genetic algorithm and the principal component analysis. Addi-tionally, each one of the characteristic feature matrices of every considered condition is modeled through a specific self-organizing map neuron grid so they can be shown in a 2-D representation. Since the SOM model provides a pattern of the behavior of every disturbance, they are used as inputs of the classifier based in a softmax layer neural network that performs the power quality disturbance detection of six different conditions: healthy or normal, sag or swell voltages, tran-sients, voltage fluctuations and harmonic distortion. Thus, the proposed method is validated using a set of synthetic signals and then it is tested using two different sets of real signals from an IEEE workgroup and from a wind park located in Spain., This research was partially funded by FONDEC-UAQ 2020 FIN202011 project. It was also supported by the Spanish `Ministerio de Ciencia Innovacion y Universidades' and FEDER program in the framework of the `Proyectos de I+D de Generacion de Conocimiento del Programa Estatal de Generacion de Conocimiento y Fortalecimiento Cientifico y Tecnologico del Sistema de I+D+i, Subprograma Estatal de Generacion de Conocimiento' (ref: PGC2018-095747-B-I00).