Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A rabbit model of Acanthamoeba keratitis: Use of infected soft contact lenses after corneal epithelium debridement with a diamond burr

  • Ortillés, Á.
  • Goñi, P.
  • Rubio, E.
  • Sierra, M.
  • Gámez, E.
  • Fernández, M.T.
  • Benito, M.
  • Cristóbal, J.Á.
  • Calvo, B.
PURPOSE. To develop a rabbit model of Acanthamoeba keratitis (AK) as the best method to reproduce the natural course of this disease. METHODS. To induce AK, infected contact lenses (1000 amoebae/mm2, 90% trophozoites) were placed over the previously debrided corneal surface, in combination with a temporary tarsorrhaphy. Environmental and clinical strains of Acanthamoeba spp. (genotype T4) were used. Three groups (1L, n = 32; 2L–21d, n = 5; 2L–3d, n = 23) were established according to the number of contact lenses used (1L, 1 lens; 2L–21d and 2L–3d, 2 lenses) and the placement day of these (1L, day 1; 2L–21d, days 1 and 21; 2L–3d, days 1 and 3). The infection was quantified by a clinical score system and confirmed using corneal cytology and culture, polymerase chain reaction and histopathologic analysis. RESULTS. The infection rate obtained was high (1L, 87.5%; 2L–21d, 100%; 2L–3d, 82.6%), although no clinical signs were observed in the 50% of the infected animals in group 1L. Among groups, group 2L–3d showed more cases of moderate and severe infection. Among strains, no statistically significant differences were found in the infection rate. In the control eyes, cross infection was confirmed when a sterile contact lens was placed in the previously debrided corneas but not if the eye remained intact. CONCLUSIONS. The combination of two infected contact lenses after corneal debridement seems to be an alternative model, clinically and histopathologically similar to its human counterpart, to induce the different AK stages and reproduce the course of the disease in rabbits.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Use of 2% hydroxypropyl methylcellulose to prevent the corneal swelling during the in vitro mechanical characterization

  • Ortilles, A.
  • Lanchares, E.
  • Cristóbal, J.A.
  • Calvo, B.
The aim of this study was to assess the use of 2% HPMC during in vitro uniaxial tensile tests, with corneal strips immediately obtained or after storing the eyes for 24¿h in 0.9% NaCl solution at 4¿¿. The purpose was to establish a standardized procedure to prevent phenomena which can modify the mechanical properties of the tissue. Rabbit eyes were divided into four groups. Group A had seven eyes that were preserved in NaCl solution for 24¿h before testing. Group B had seven eyes that were immediately tested. In both groups, to prevent both swelling and dehydration, 2% hydroxypropyl methylcellulose (2% HPMC) was applied. Group C had seven eyes that were preserved in NaCl solution for 24¿h before testing. Group D had seven eyes that were immediately tested. In both groups, HPMC was not applied. Regarding the mechanical response, groups with HPMC showed similar Cauchy stress–stretch curves and there were no statistically significant differences at 5%, 10% and 15% strain between them, which mean that both showed similar mechanical behavior. The same result was obtained between groups without HPMC. However, for coupled groups with and without HPMC, statistically significant differences at 10% and 15% strain were observed. On the other hand, when grouped by storage time, statistically significant differences were found between groups that had eyes preserved for 24¿h with and without HPMC, respectively, as well as between groups immediately tested with and without HPMC, respectively, at 15% strain. Nevertheless, if coupled groups were considered, between groups that were preserved for 24¿h in NaCl before testing and groups that were immediately tested, no statistically significant differences were obtained. In addition, the Cauchy stress–stretch curves of groups without HPMC showed a decreasing slope of the linear part (strain¿>¿8%) of the graph during the experiment. In summary, the use of HPMC during the handling of the tissue from excision to testing seems to prevent both swelling and dehydration.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Mechanical behavior of surgical meshes for abdominal wall repair: In vivo versus biaxial characterization

  • Simón-Allué, R.
  • Ortillés, A.
  • Calvo, B.
Despite the widespread use of synthetic meshes in the surgical treatment of the hernia pathology, the election criteria of a suitable mesh for specific patient continues to be uncertain. Thus, in this work, we propose a methodology to determine in advance potential disadvantages on the use of certain meshes based on the patient-specific abdominal geometry and the mechanical features of the certain meshes. To that purpose, we have first characterized the mechanical behavior of four synthetic meshes through biaxial tests. Secondly, two of these meshes were implanted in several New Zealand rabbits with a total defect previously created on the center of the abdominal wall. After the surgical procedure, specimen were subjected to in vivo pneumoperitoneum tests to determine the immediate post-surgical response of those meshes after implanted in a healthy specimen. Experimental performance was recorded by a stereo rig with the aim of obtaining quantitative information about the pressure-displacement relation of the abdominal wall. Finally, following the procedure presented in prior works (Simón-Allué et al., 2015, 2017), a finite element model was reconstructed from the experimental measurements and tests were computationally reproduced for the healthy and herniated cases. Simulations were compared and validated with the in vivo behavior and results were given along the abdominal wall in terms of displacements, stresses and strain. Mechanical characterization of the meshes revealed Surgipro TM as the most rigid implant and Neomesh SuperSoft® as the softer, while other two meshes (Neomesh Soft® Neopore®) remained in between. These two meshes were employed in the experimental study and resulted in similar effect in the abdominal wall cavity and both were close to the healthy case. Simulations confirmed this result while showed potential objections in the case of the other two meshes, due to high values in stresses or elongation that may led to discomfort in real tissue. The use of this methodology on human surgery may provide the surgeons with reliable and useful information to avoid certain meshes on specific-patient treatment.