Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

An integrated low-power lock-in amplifier and its application to gas detection

  • Maya-Hernández, P.M.
  • Álvarez-Simón, L.C.
  • Sanz-Pascual, M.
  • Calvo-López, B.
This paper presents a new micropower analog lock-in amplifier (LIA) suitable for battery-operated applications thanks to its reduced size and power consumption as well as its operation with single-supply voltage. The proposed LIA was designed in a 0.18 µm CMOS process with a single supply voltage of 1.8 V. Experimental results show a variable DC gain ranging from 24.7 to 42 dB, power consumption of 417 µW and integration area of 0.013 mm2. The LIA performance was demonstrated by measuring carbon monoxide concentrations as low as 1 ppm in dry N2. The experimental results show that the response to CO of the sensing system can be considerably improved by means of the proposed LIA.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

Portable lock-in amplifier for microcantilever based sensor array. Application to explosives detection using Co-BEA type zeolites as sensing materials

  • García-Romeo, D.
  • Calvo, B.
  • Medrano, N.
  • Pina, M.P.
  • Almazán, F.
  • Pellejero, I.
  • Urbiztondo, M.
  • Sesé, J.
  • Santamaría, J
Recent advances in microcantilever-based sensors have led to a significant increase in sensitivity, making them a competitive solution in highly demanding applications as explosives detection. However, these sensors face severe challenges related to: reliability, sensitivity, reproducibility and throughput; that have yet to be solved for commercial applications. This paper describes our efforts in this direction, particularly on the reproducible detection of nitroaromatic type explosives by means of parallelization combined with: i) nanoporous solids as sensing materials; and, ii) a portable lowpower electronic readout interface capable of both excitation and measurement of the multisensing platform. The response of the sensor array, comprising 4 microcantilevers, due to presence of 2-nitrotoluene, a common explosive taggant, has been properly monitored. The obtained results with 4 identical Co-BEA coated Si microcantilevers underline the importance of a proper sensing material degassing on the sensor performance.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Portable low-power electronic interface for explosive detection using microcantilevers

  • García-Romeo, D.
  • Pellejero, I.
  • Urbiztondo, M. A.
  • Sesé, J.
  • Pina, M. P.
  • Martínez, P. A.
  • Calvo, B.
  • Medrano, N.
Microcantilevers have been recently revealed as a highly effective technique for gas detection at trace level when acting as chemical sensors. However, an important milestone still remains to achieve a full-scale development in commercial applications: the cumbersome systems traditionally used to read-out its responses. To accomplish this, a portable low-power electronic interface, based on an analog lock-in amplifier processing square signals, which is fully capable of creating the excitation signal as well as obtaining the response values from resonating microcantilevers functionalized with zeolite based coatings has been herein attempted. The so obtained read-out results are in good agreement with the commercial lock-in amplifier's measurements, demonstrating the accuracy and reliability of the electronic interface. Finally, its performance has been validated for 2-nitrotoluene (o-MNT) detection at ppm V level, as an example of an explosive-related molecule, with BEA zeolite coated microcantilevers. Theoretical limit of detection (LOD) values below 100 ppb have been obtained for Co exchanged BEA modified sensors.