Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Heart Rate Variability and Exceptional Longevity

  • Hernández-Vicente, A.
  • Hernando, D.
  • Santos-Lozano, A.
  • Rodríguez-Romo, G.
  • Vicente-Rodríguez, G.
  • Pueyo, E.
  • Bailón, R.
  • Garatachea, N.
Centenarians are the paradigm of human extreme longevity and healthy aging, because they have postponed, if not avoided, mayor age-related diseases. The purpose of this study was to investigate potential differences in resting heart rate variability (HRV) between young adults, octogenarians, and centenarians and assess whether HRV variables are predictors of all-cause mortality in centenarians. To this end, three groups of participants: young adults (N = 20; 20.6 ± 2.3 years), octogenarians (N = 18; 84.1 ± 2.6 years), and centenarians (N = 17; 101.9 ± 1.9 years) were monitored for 15 min at rest (seated, without moving or talking) to measure RR intervals, from which HRV was evaluated. Our results showed a clear decrease with age in the main parasympathetic HRV variables, as well as in the standard deviation (SD) of the RR series [SD of normal-to-normal interval (SDNN)] and in low frequency (LF) heart rate (HR) oscillations, although differences between octogenarians and centenarians did not reach statistical significance. In 14 centenarians followed until death, only SDNN showed significant correlation (¿ = 0.536; p = 0.048) with survival prognosis. Additionally, SDNN <19 ms was associated with early mortality (=1 year) in centenarians (Hazard Ratio = 5.72). In conclusion, HRV indices reflecting parasympathetic outflow as well as SDNN and LF all present an age-related reduction, which could be representative of a natural exhaustion of allostatic systems related to age. Moreover, low SDNN values (<19 ms) could be associated with early mortality in centenarians. HRV seems to play a role in exceptional longevity, which could be accounted for by centenarians’ exposome.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Validity of the polar h7 heart rate sensor for heart rate variability analysis during exercise in different age, body composition and fitness level groups

  • Hernández-Vicente, A.
  • Hernando, D.
  • Marín-Puyalto, J.
  • Vicente-Rodríguez, G.
  • Garatachea, N.
  • Pueyo, E.
  • Bailón, R.
This work aims to validate the Polar H7 heart rate (HR) sensor for heart rate variability (HRV) analysis at rest and during various exercise intensities in a cohort of male volunteers with different age, body composition and fitness level. Cluster analysis was carried out to evaluate how these phenotypic characteristics influenced HR and HRV measurements. For this purpose, sixty-seven volunteers performed a test consisting of the following consecutive segments: sitting rest, three submaximal exercise intensities in cycle-ergometer and sitting recovery. The agreement between HRV indices derived from Polar H7 and a simultaneous electrocardiogram (ECG) was assessed using concordance correlation coefficient (CCC). The percentage of subjects not reaching excellent agreement (CCC > 0.90) was higher for high-frequency power (PHF) than for low-frequency power (PLF) of HRV and increased with exercise intensity. A cluster of unfit and not young volunteers with high trunk fat percentage showed the highest error in HRV indices. This study indicates that Polar H7 and ECG were interchangeable at rest. During exercise, HR and PLF showed excellent agreement between devices. However, during the highest exercise intensity, CCC for PHF was lower than 0.90 in as many as 60% of the volunteers. During recovery, HR but not HRV measurements were accurate. As a conclusion, phenotypic differences between subjects can represent one of the causes for disagreement between HR sensors and ECG devices, which should be considered specifically when using Polar H7 and, generally, in the validation of any HR sensor for HRV analysis.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Physical activity in centenarians beyond cut-point-based accelerometer metrics

  • Hernández-Vicente, A.
  • Marín Puyalto, J.
  • Pueyo, E.
  • Vicente Rodríguez, G.
  • Garatachea, N.
This study described and compared physical activity (PA) characteristics at the end of the human lifespan using conventional cut-point-based versus cut-point-free accelerometer metrics. Eighteen institutionalized centenarians (101.5 ± 2.1 years, 72.2% female, 89% frail) wore the wrist GENEActiv accelerometer for 7 days. Conventional metrics, such as time spent in light-intensity PA (LiPA) and moderate-to-vigorous intensity PA (MVPA) were calculated according to published cut-points for adults and older adults. The following cut-point-free metrics were evaluated: average acceleration, intensity gradient and Mx metrics. Depending on the cut-point, centenarians accumulated a median of 15–132 min/day of LiPA and 3–15 min/day of MVPA. The average acceleration was 9.2 mg [Q1: 6.7 mg–Q3: 12.6 mg] and the intensity gradient was −3.19 [−3.34–−3.12]. The distribution of Z-values revealed positive skew for MVPA, indicating a potential floor effect, whereas the skew magnitude was attenuated for cut-point-free metrics such as intensity gradient or M5. However, both cut-point-based and cut-point-free metrics were similarly positively associated with functional independence, cognitive and physical capacities. This is the first time that PA has been described in centenarians using cut-point-free metrics. Our results suggest that new analytical approaches could overcome cut-point limitations when studying the oldest-old. Future studies using these new cut-point-free PA metrics are warranted to provide more complete and comparable information across groups and populations.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

ECG ventricular repolarization dynamics during exercise: Temporal profile, relation to heart rate variability and effects of age and physical health

  • Hernández-Vicente, Adrián
  • Hernando, David
  • Vicente-Rodríguez, Germán
  • Bailón, Raquel
  • Garatachea, Nuria
  • Pueyo, Esther
Periodic repolarization dynamics (PRD) is a novel electrocardiographic marker of cardiac repolarization instability with powerful risk stratification capacity for total mortality and sudden cardiac death. Here, we use a time-frequency analysis approach to continuously quantify PRD at rest and during exercise, assess its dependence on heart rate variability (HRV) and characterize the effects of age (young adults/middle-aged adults/older adults), body mass index (non-overweight/overweight) and cardiorespiratory fitness level (fit/unfit). Sixty-six male volunteers performed an exercise test. RR and dT variabilities (RRV, dTV), as well as the fraction of dT variability unrelated to RR variability, were computed based on time-frequency representations. The instantaneous LF power of dT (PdTV), representing the same concept as PRD, and of its RRV-unrelated component (PdTVuRRV) were quantified. dT angle was found to mostly oscillate in the LF band. Overall, 50-70% of PdTV was linearly unrelated to RRV. The onset of exercise caused a sudden increase in PdTV and PdTVuRRV, which returned to pre-exercise levels during recovery. Clustering analysis identified a group of overweight and unfit individuals with significantly higher PdTV and PdTVuRRV values at rest than the rest of the population. Our findings shed new light on the temporal profile of PRD during exercise, its relationship to HRV and the differences in PRD between subjects according to phenotypic characteristics. © 2021 by the authors. Licensee MDPI, Basel, Switzerland.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Cardiac magnetic resonance tissue characterization in endurance athletes with paroxysmal atrial fibrillation phenotype (PAFIYAMA)

  • Garatachea, Nuria
  • Echevarría-Polo, Marcos
  • Hernández-Vicente, Adrián
  • D'Ascenzi, Flavio
  • Fabregat-Andrés, Óscar
  • Grazioli, Gonzalo
  • de la Guía-Galipienso, Fernando
  • Sanchis-Gomar, Fabian
Background Endurance athletes have an increased risk of atrial fibrillation (AF), and focal late gadolinium enhancement (LGE) is frequently detected on cardiac magnetic resonance (CMR); however, whether myocardial fibrosis or diffuse myocardial abnormalities underlie AF-related functional phenotypes remains unclear. We previously described a paroxysmal AF phenotype in male endurance athletes (PAFIYAMA), characterized by reduced forward flow despite preserved global systolic function; nonetheless, the underlying myocardial substrate remains unknown. Methods In this observational cross-sectional study, 63 competitive male endurance athletes (PAFIYAMA n = 22; controls n = 41) underwent CMR with cine imaging, LGE, native T1, extracellular volume fraction (ECV), and T2 mapping. Training load was derived from the Lifetime Total Physical Activity Questionnaire. Group comparisons and multivariable models adjusted for age, body mass index, training load, and peak exercise blood pressure. Results Focal LGE was present in 15/63 (24%) athletes and did not differ between PAFIYAMA and controls. Among LGE-positive athletes, enhancement was predominantly hinge-point/insertional (8/15, 53.3%) or limited septal intramyocardial (6/15, 40.0%), with one subepicardial lateral case (1/15, 6.7%). Athletes with LGE had larger indexed biventricular volumes but similar native T1, ECV, and T2. Compared with controls, PAFIYAMA athletes showed lower biventricular stroke volume indices and lower left ventricle mass, with a slightly lower LVEF that remained within the normal range, and no differences in LGE prevalence or mapping indices. Conclusions In endurance athletes with the PAFIYAMA phenotype, CMR tissue characterization does not support focal LGE or diffuse mapping abnormalities as the substrate of the functional phenotype; interpretation of LGE in athletes should integrate pattern and clinical context.