Proposed criteria to determine experimentally the transmission length of prestressed reinforcement, Proponowane kryteria eksperymentalnego okre¿lania d¿ugo¿ci odcinka przekazywania si¿y zbrojenia spr¿¿aj¿cego

  • Arbeláez, C.A.
  • Martí Vargas, José Rocío|||0000-0003-1665-2348
  • Serna Ros, Pedro|||0000-0001-8754-1165
  • Castro-Bugallo, M Carmen|||0000-0001-9201-6162
[EN] In pretensioned concrete, the force in the prestressing reinforcement is transferred to the concrete by bond in the end region of the member. The distance from the end of the member over which the effective prestressing force is developed is called transmission length. Two indirect methods to determine the transmission length have been habitually used: measurement of the strain in the surface of the concrete and measurement of the reinforcement end slip. Groups of specimens with different embedment length with the objective to experimentally determine the transmission length had been tested. The ECADA method based on the analysis of the supported force by the strand in different sections of a prestressed concrete element have been applied. The specimens had also been instrument with lineal slips measurement devices, in each end of the specimen. The bond phenomena are not disturbed by any of the measurements devices. The ECADA method criteria to determine the transmission length had been applied. The force vs. strand end slips relations during the release had been analyzed. A sequence of slips values in each end of the specimen after the release, in correspondence to the embedment length tested had been obtained. The sequence of slips values (at both ends of the specimen) show a bilinear behaviour, a falling branch with increasing embedment lengths and a horizontal branch, this, corresponding to the cases of embedment length equal or higher to the transmission length. Therefore, both strand end slips sequences allow to establish new criteria to experimentally determine the transmission length., [Otros] Badano relacje pomi¿dzy si¿¿ w zbrojeniu a po¿lizgiem zbrojenia na obu kra¿cach próbki podczas zwalniania si¿y, w grupach próbek o ró¿nej d¿ugo¿ci zakotwienia. Obie sekwencje warto¿ci po¿lizgu przyjmuj¿ form¿ nieliniow¿, krzywa jest opadaj¿ca wraz ze wzrostem d¿ugo¿ci zakotwienia oraz pozioma, odpowiadaj¿ca przypadkom, kiedy odcinek przekazywania si¿y spr¿¿aj¿cej jest równy lub wi¿kszy ni¿ d¿ugo¿¿ zakotwienia. Tak wi¿c obie sekwencje warto¿ci po¿lizgu pozwalaj¿ utworzy¿ dwa nowe kryteria do¿wiadczalnego ustalania d¿ugo¿ci zakotwienia., The content of the present communication is part of a line of investigation that is carrying out by the Concrete Technology and Science Institute (ICITECH) of the Polytechnic University of Valencia in collaboration with companies PREVALESA and ISOCRON. This work counts with the financing of the Ministerio de Educación y Cultura (Project MAT2000-0346-P4-03) and Ministerio de Ciencia y Tecnología and funds FEDER (Project MAT2003-07157). We appreciate the collaboration of the companies and organizations above indicated, and the participation of the technical staff from the Concrete Structures Laboratory of the U. P. de Valencia.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Analytical model for transfer length prediction of 13 mm prestressing strand

  • Martí Vargas, José Rocío|||0000-0003-1665-2348
  • Serna Ros, Pedro|||0000-0001-8754-1165
  • Navarro-Gregori, Juan|||0000-0002-6319-7029
  • Pallarés Rubio, Luis|||0000-0003-2126-2387
  • Arbeláez, C.A.
An experimental investigation to determine the transfer length of a seven-wire prestressing strand in different concretes is presented in this paper. A testing technique based on the analysis of bond behaviour by means of measuring the force supported by the prestressing strand on a series of specimens with different embedment lengths has been used. An analytical bond model to calculate the transfer length from an inelastic bond stress distribution along the transfer length has been obtained. A relationship between the plastic bond stress for transfer length and the concrete compressive strength at the time of prestress transfer has been found. An equation to predict the average and both the lower bound and the upper bound values of transfer length is proposed. The experimental results have not only been compared with the theoretical prediction from proposed equations in the literature, but also with experimental results obtained by several researchers., The content of the present paper is part of a research that is being carried out by the Concrete Technology and Science Institute (ICITECH) of the Polytechnic University of Valencia in collaboration with the companies PREVALESA and ISOCRON. This work has been financed by the Ministerio de Ciencia y Tecnología and by FEDER funds (Project MAT2003-07157). We appreciate the collaboration of the aforementioned companies and organizations, as well as the participation of the technical staff from the Concrete Structures Laboratory of the Polytechnic University of Valencia
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Reliability of transmission length estimation from strand end slip

  • Martí Vargas, José Rocío|||0000-0003-1665-2348
  • Serna Ros, Pedro|||0000-0001-8754-1165
  • Castro-Bugallo, M Carmen|||0000-0001-9201-6162
  • Arbeláez, César A.
[EN] An experimental program on twelve series of specimens with different embedment lengths to determine the transfer length was conducted. Transfer length test results of seven-wire strand on twelve different concrete mixtures were analyzed. A testing technique based on the analysis of bond behaviour by means of measuring the force supported by the tendon has been used. The specimens had been instrumented with slip measurement devices at each end of the specimen. A sequence of slip values at each end of the specimen after release versus the embedment length has been analyzed. The expressions relating the transfer length to the tendon end slip are presented. A value of Guyon's factor for tendon stress distribution shape has been obtained. Two criteria to determine the transfer length from the slip sequences at both ends of the specimens have been analyzed., The contents of this paper are within the framework of a line of research that is currently being carried out by the Concrete Technology and Science Institute (ICITECH) of the Polytechnic University of Valencia, Valencia, Spain, in collaboration with the companies PREVALESA and ISOCRON. Financial support provided by the Ministry of Education and Science and FEDER funds (Project MAT2003-07157 and Project BIA2006-05521) made this research possible. The authors appreciate the collaboration of the aforementioned companies and organizations, as well as the participation of the technical staff of the Concrete Structures Laboratory at the Polytechnic University of Valencia for their assistance in preparing and testing specimens.