Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 12
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Size Effect on Strand Bond and Concrete Strains at Prestress Transfer

  • Martí Vargas, José Rocío|||0000-0003-1665-2348
  • Serna Ros, Pedro|||0000-0001-8754-1165
  • Caro Forero, Libardo Andrés
[EN] The size-effect phenomenon has been analyzed with pretensioned prestressed concrete prismatic specimens at prestress transfer. An experimental program that includes variables such as concrete mixture design, specimen cross section size, and concrete age, has been conducted. Several series of specimens with different embedment lengths have been made and tested using a testing technique based on the bond behavior analysis by measuring prestressing strand force. In addition, some specimens have been instrumented to determine longitudinal concrete strain profiles. The tests have provided data on concrete strains, transfer length, effective prestressing force, bond stress, and concrete modulus of elasticity. Relationships between measured prestressing strand forces and effective prestressing forces obtained from concrete compressive strains have been found. A coefficient to account for the specimen crosssection size-effect on the concrete modulus of elasticity has been proposed. Comparisons between test results and theoretical predictions from pre-existing equations in the codes have been made., Funding for this research has been provided by the Spanish Ministry of Education and Science, the Ministry of Science and Innovation, and ERDF (Projects BIA2006-05521 and BIA2009-12722).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Prestress losses evaluation in prestressed concrete prismatic specimens

  • Caro Forero, Libardo Andrés
  • Martí Vargas, José Rocío|||0000-0003-1665-2348
  • Serna Ros, Pedro|||0000-0001-8754-1165
This paper presents an experimental research work to evaluate prestress losses in pretensioned prestressed concrete. An experimental program including variables such as concrete mix design, specimen cross-section size and concrete age at the prestress transfer was carried out. Several pretensioned prestressed concrete prismatic specimens were made and tested using the ECADA+ test method, based on measuring prestressing reinforcement force. In addition, specimens were instrumented to obtain the longitudinal concrete strains profiles at any time. Measurements from both techniques were taken over 1 year. Measured prestress losses included elastic shortening losses and time-dependent losses due to concrete shrinkage and creep. A coefficient to account for the relationship between the prestress losses from the measured prestressing forces and the actual prestress losses from concrete compressive strains is proposed. The experimental results were compared with the predicted prestress losses using methods from several codes., Funding for this experimental research work has been provided by the Spanish Ministry of Education and Science and ERDF (Project BIA2006-05521 and Project BIA2009-12722). Tests have been conducted at the Institute of Concrete Science and Technology (ICI-TECH), at the Universitat Politecnica de Valencia (Spain).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Slip distribution model along the anchorage length of prestressing strands

  • Martí Vargas, José Rocío|||0000-0003-1665-2348
  • Serna Ros, Pedro|||0000-0001-8754-1165
  • Hale, WM
  • García Taengua, Emilio José
An analytical model to predict strand slips within both transmission and anchorage lengths in pretensioned prestressed concrete members is presented. This model has been derived from an experimental research work by analysing the bond behavior and determining the transmission and anchorage lengths of seven-wire prestressing steel strands in different concrete mixes. A testing technique based on measuring the prestressing strand force in specimens with different embedment lengths has been used. The testing technique allows measurement of free end slip as well as indirect determination of the strand slip at different cross sections of a member without interfering with bond phenomena. The experimental results and the proposed model for strand slip distribution have been compared with theoretical predictions according to different equations in the literature and with experimental results obtained by other researchers., The content of the present paper is based on tests which were conducted in the Institute of Concrete Science and Technology (ICI-TECH), at Universitat Politecnica of Valencia (Spain), in collaboration with the companies PREVALESA and ISOCRON. Funding for this experimental research work was provided by the Spanish Ministry of Education and Science/Science and Innovation and ERDF (Project BIA2006-05521 and Project BIA2009-12722). The authors wish to thank the above companies as well as the concrete structures laboratory technicians at the Universitat Politecnica of Valencia for their cooperation. Finally, the authors also wish to pay their respects to C.A. Arbelaez.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Measuring specific parameters in pretensioned concrete members using a single testing technique

  • Martí Vargas, José Rocío|||0000-0003-1665-2348
  • Serna Ros, Pedro|||0000-0001-8754-1165
  • García Taengua, Emilio José
  • Caro Forero, Libardo Andrés
Pretensioned concrete members are designed and manufactured by using at least two materials: concrete and prestressing reinforcement. Also, two main stages must be considered: prestress transfer and member loading. Hence, the behavior of these members depends strongly on the reinforcement-to-concrete bond performance and prestress losses. In this paper, a testing technique to measure the specific parameters related with the involved phenomena is presented. The testing technique is based on the analysis of series of specimens varying in embedment length to simulate several cross sections at only one end of a pretensioned concrete member. Each specimen is characterized by means of the sequential release of the prestress transfer (detensioning) and the pull-out (loading) operation. The test provides data on prestressing force, transmission length (initial and long-term), anchorage length (without and with slip), reinforcement slips, bond stresses, longitudinal concrete strains, concrete modulus of elasticity, and prestress losses (instantaneous and time-dependent)., The content of this paper is part of the research that the Institute of Concrete Science and Technology (ICITECH) at Universitat Politecnica de Valencia is currently conducting in conjunction with PREVALESA and ISOCRON. This study has been funded by the Ministry of Education and Science/ Science and Innovation and ERDF (Projects BIA2006-05521 and BIA2009-12722). The authors wish to thank the aforementioned companies as well as the technicians at the concrete structures laboratory of the Universitat Politecnica de Valencia for their cooperation. Finally, the authors wish to pay their respects to C.A. Arbelaez.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Bond of 13 mm prestressing steel strands in pretensioned concrete members

  • Martí Vargas, José Rocío|||0000-0003-1665-2348
  • Serna Ros, Pedro|||0000-0001-8754-1165
  • Navarro-Gregori, Juan|||0000-0002-6319-7029
  • Pallarés Rubio, Luis|||0000-0003-2126-2387
This paper presents an experimental research work to determine both the transmission and the anchorage lengths of seven-wire prestressing steel strands in different concrete mixes. A testing technique based on a bond behavior analysis by measuring the force supported by the prestressing strand on a series of specimens with different embedment lengths has been used. Relationships between the average bond stress for both the transmission length and anchorage length as a function of the concrete compressive strength have been found. Equations to compute transmission and anchorage lengths of 13 mm prestressing strands have been obtained. The experimental results have been compared with the theoretical prediction from proposed equations in the literature and with experimental results from other authors. 2012 Elsevier Ltd. All rights reserved., The content of this article forms part of the research work that the Institute of Concrete Science and Technology (ICITECH) is presently conducting in conjunction with PREVALESA and ISOCRON. This study has been funded by the Spanish Ministry of Education and Science and ERDF (Project BIA2006-05521). The authors wish to thank the above companies as well as the concrete structures laboratory technicians at the Universitat Politecnica de Valencia for their cooperation. Finally, the authors also wish to pay their respects to C.A. Arbelaez.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Effects of concrete composition on transmission length of prestressing strands

  • Martí Vargas, José Rocío|||0000-0003-1665-2348
  • Serna Ros, Pedro|||0000-0001-8754-1165
  • Navarro-Gregori, Juan|||0000-0002-6319-7029
  • Bonet Senach, José Luís|||0000-0002-6687-5307
The bond behaviour of prestressing strands in precast pretensioned concrete members, and its transmission length, depends on several factors. However, no consensus exists on the main parameters to be considered in the expressions to predict the transmission length. Usually when the concrete properties are considered, only the concrete compressive strength is included. This study analyzes the influence of concrete composition made up of different cement contents and water/cement ratios on the bond behaviour in transmission of seven-wire prestressing strands. The bond properties and the transmission lengths have been determined. The results show that the influence of the water/cement ratio is very small for concretes with lows cement contents, but the influence of the water/cement ratio on the transmission lengths is highly significant when cement content is high. The effect of cement content in the transmission lengths can reveal different tendencies based on the level of the water/cement ratio, The content of this article forms a part of research that the Universitat Politecnica de Valencia's Institute of Concrete Science and Technology (ICITECH) is presently conducting in conjunction with PREVALESA and ISOCRON. This study was funded by the Ministry of Education and Science and ERDF (Project BIA2006-05521). The authors wish to thank the above companies as well as the concrete structures laboratory technicians at the Universitat Politecnica de Valencia for their cooperation. Also, the authors wish to pay their respects to C.A. Arbelaez.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Reliability of transmission length estimation from strand end slip

  • Martí Vargas, José Rocío|||0000-0003-1665-2348
  • Serna Ros, Pedro|||0000-0001-8754-1165
  • Castro-Bugallo, M Carmen|||0000-0001-9201-6162
  • Arbeláez, César A.
[EN] An experimental program on twelve series of specimens with different embedment lengths to determine the transfer length was conducted. Transfer length test results of seven-wire strand on twelve different concrete mixtures were analyzed. A testing technique based on the analysis of bond behaviour by means of measuring the force supported by the tendon has been used. The specimens had been instrumented with slip measurement devices at each end of the specimen. A sequence of slip values at each end of the specimen after release versus the embedment length has been analyzed. The expressions relating the transfer length to the tendon end slip are presented. A value of Guyon's factor for tendon stress distribution shape has been obtained. Two criteria to determine the transfer length from the slip sequences at both ends of the specimens have been analyzed., The contents of this paper are within the framework of a line of research that is currently being carried out by the Concrete Technology and Science Institute (ICITECH) of the Polytechnic University of Valencia, Valencia, Spain, in collaboration with the companies PREVALESA and ISOCRON. Financial support provided by the Ministry of Education and Science and FEDER funds (Project MAT2003-07157 and Project BIA2006-05521) made this research possible. The authors appreciate the collaboration of the aforementioned companies and organizations, as well as the participation of the technical staff of the Concrete Structures Laboratory at the Polytechnic University of Valencia for their assistance in preparing and testing specimens.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Influence of concrete composition on anchorage bond behavior of prestressing reinforcement

  • Martí Vargas, José Rocío|||0000-0003-1665-2348
  • Serna Ros, Pedro|||0000-0001-8754-1165
  • García Taengua, Emilio José
An experimental research addressing the effects of concrete composition and strength on anchorage bond behavior of prestressing reinforcement is presented to clarify the effect of material properties that have appeared contradictory in previous literature. Bond stresses and anchorage lengths have been obtained in twelve concrete mixes made up of different cement contents (C) - 350 to 500 kg/m(3) - and water/cement (w/c) ratios - 0.3 to 0.5 - with compressive strength at 24 h ranging from 24 to 55 MPa. A testing technique based on measuring the prestressing force in specimens with different embedment lengths has been used. The results show that anchorage length increases when w/c increases, more significantly when C is higher; the effect of C reveals different trends based on w/c. The obtained anchorage bond stresses are greater for higher concrete compressive strength, and their average ratio of 1.45 with respect to transmission bond stresses implies a potential bond capacity. (C) 2013 Elsevier Ltd. All rights reserved., The content of this article is part of the research that the Institute of Concrete Science and Technology (ICITECH) at Universitat Politecnica de Valencia is currently conducting in conjunction with PREVALESA and ISOCRON. This study has been funded by the Ministry of Education and Science/Science and Innovation and ERDF (Projects BIA2006-05521 and BIA2009-12722). The authors wish to thank the aforementioned companies as well as the technicians at the concrete structures laboratory of the Universitat Politecnica de Valencia for their cooperation. Finally, the authors wish to pay their respects to C.A. Arbelaez.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Time-dependent evolution of strand transfer length in pretensioned prestressed concrete members

  • Caro Forero, Libardo Andrés
  • Martí Vargas, José Rocío|||0000-0003-1665-2348
  • Serna Ros, Pedro|||0000-0001-8754-1165
For design purposes, it is generally considered that prestressing strand transfer length does not change with time. However, some experimental studies on the effect of time on transfer lengths show contradictory results. In this paper, an experimental research to study transfer length changes over time is presented. A test procedure based on the ECADA testing technique to measure prestressing strand force variation over time in pretensioned prestressed concrete specimens has been set up. With this test method, an experimental program that varies concrete strength, specimen cross section, age of release, prestress transfer method, and embedment length has been carried out. Both the initial and long-term transfer lengths of 13-mm prestressing steel strands have been measured. The test results show that transfer length variation exists for some prestressing load conditions, resulting in increased transfer length over time. The applied test method based on prestressing strand force measurements has shown more reliable results than procedures based on measuring free end slips and longitudinal strains of concrete. An additional factor for transfer length models is proposed in order to include the time-dependent evolution of strand transfer length in pretensioned prestressed concrete members. © 2012 Springer Science+Business Media Dordrecht., Funding for this experimental research work has been provided by the Spanish Ministry of Education and Science and ERDF (Projects BIA2006-05521 and BIA2009-12722). Tests have been conducted at the Institute of Concrete Science and Technology (ICITECH), at the Universitat Politecnica de Valencia (Spain).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Experimental Technique for Measuring the Long-term Transfer Length in Prestressed Concrete

  • Martí Vargas, José Rocío|||0000-0003-1665-2348
  • Serna Ros, Pedro|||0000-0001-8754-1165
  • Caro Forero, Libardo Andrés
This article presents a proposal of a test set-up and methodology for testing the transfer length evolution through time of prestressing reinforcement in pretensioned prestressed concrete members, aimed at providing a basis for standardization. The proposed test method is based on the instantaneous and time-related analysis of the prestressing reinforcement force profile at only one end of a pretensioned prestressed concrete member. The basis of the test method and the requirements of the prestressing frame and its components are presented, as well as the test procedure stages and the measurement devices. The interpretation of the test results and the criteria to determine both the initial and the long-term transfer lengths are explained. A test method application and the equipment for testing seven-wire prestressing strands have been designed. Some experimental results are provided to validate the test. A comparative analysis of test reliability with other existing experimental methods is also included. © 2012 Wiley Publishing Ltd., Funding for this experimental research work was provided by the Spanish Ministry of Education and Science and ERDF (Projects BIA2006-05521 and BIA2009-12722). Tests were conducted in the Institute of Concrete Science and Technology (ICITECH), Universitat Politecnica de Valencia (Spain).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Prediction of the transfer length of prestressing strands with neural networks

  • Martí Vargas, José Rocío|||0000-0003-1665-2348
  • Yepes, V.|||0000-0001-5488-6001
  • FERRI RABASA, FRANCESC J
This paper presents a study on the prediction of transfer length of 13 mm seven-wire prestressing steel strand in pretensioned prestressed concrete members with rectangular cross-section including several material properties and design and manufacture parameters. To this end, a carefully selected database consisting of 207 different cases coming from 18 different sources spanning a variety of practical transfer length prediction situations was compiled. 16 single input features and 5 combined input features are analyzed. A widely used feedforward neural regression model was considered as a representative of several machine learning methods that have already been used in the engineering field. Classical multiple linear regression was also considered in order to comparatively assess performance and robustness in this context. The results show that the implemented model has good prediction and generalization capacity when it is used on large input data sets of practical interest from the engineering point of view. In particular, a neural model is proposed -using only 4 hidden units and 10 input variables- which significantly reduces in 30% and 60% the errors in transfer length prediction when using standard linear regression or fixed formulas, respectively., Funding for this study were received from the Spanish Ministry of Science and Innovation and ERDF (Research Project BIA2006-05521, BIA2009-12722, and BIA2011-23602) and from the Spanish Ministry of Education (TIN2009-14205-C04-03 and Consolider Ingenio 2010 CSD2007-00018), as well as the European Community with the FEDER funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Strand bond performance in prestressed concrete accounting for bondslip

  • Martí Vargas, José Rocío|||0000-0003-1665-2348
  • Serna Ros, Pedro|||0000-0001-8754-1165
  • Hale, W. M.
This paper presents the results of an experimental research program addressing the bond behavior of prestressing strands in pretensioned prestressed concrete members after anchorage failure has occurred. A test methodology based on measuring the prestressing strand force and strand end slip at the specimens free end was employed. Transmission- and anchorage-length tests were performed on several series of prestressed specimens with different embedment lengths using twelve concrete mixes. Average bond stresses along the transmission length and the anchorage length were obtained for specimens with release strengths ranging from 24 MPa to 55 MPa. For the anchorage analysis, a parameter was developed that includes strand slip to be used in determining anchorage length. Based on the test results, an analysis to experimentally substantiate the Stress Waves Theory of Janney has been proposed. Additionally, the potential bond performance of prestressing strands after anchorage failure at the end regions has been suggested., The content of the present paper is based on tests which were conducted in the Institute of Concrete Science and Technology (ICITECH), at Universitat Politecnica of Valencia (Spain), in collaboration with the companies PREVALESA and ISOCRON. Funding for this experimental research work was provided by the Spanish Ministry of Education and Science/Science and Innovation and ERDF (Project BIA2006-05521 and Project BIA2009-12722). The authors wish to thank the above companies as well as the concrete structures laboratory technicians at the Universitat Politecnica of Valencia for their cooperation. Finally, the authors also wish to pay their respects to C.A. Arbelaez.