DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Macrophage Biocompatibility of CoCr Wear Particles Produced under Polarization in Hyaluronic Acid Aqueous Solution

  • Pérez-Maceda, B. T.
  • López-Fernández, M.E.
  • Díaz, Iván
  • Kavanaugh, Aaron
  • Billi, Fabrizio
  • Escudero Rincón, María Lorenza
  • García-Alonso, M. C.
  • Lozano, R.M.
Macrophages are the main cells involved in inflammatory processes and in the primary response to debris derived from wear of implanted CoCr alloys. The biocompatibility of wear particles from a high carbon CoCr alloy produced under polarization in hyaluronic acid (HA) aqueous solution was evaluated in J774A.1 mouse macrophages cultures. Polarization was applied to mimic the electrical interactions observed in living tissues. Wear tests were performed in a pin-on-disk tribometer integrating an electrochemical cell in phosphate buffer solution (PBS) and in PBS supplemented with 3 g/L HA, an average concentration that is generally found in synovial fluid, used as lubricant solution. Wear particles produced in 3 g/L HA solution showed a higher biocompatibility in J774A.1 macrophages in comparison to those elicited by particles obtained in PBS. A considerable enhancement in macrophages biocompatibility in the presence of 3 g/L of HA was further observed by the application of polarization at potentials having current densities typical of injured tissues suggesting that polarization produces an effect on the surface of the metallic material that leads to the production of wear particles that seem to be macrophage-biocompatible and less cytotoxic. The results showed the convenience of considering the influence of the electric interactions in the chemical composition of debris detached from metallic surfaces under wear corrosion to get a better understanding of the biological effects caused by the wear products., Financial support received through the MAT2015-67750-C3-2-R, MAT2015-67750-C3-1-R, MAT2011 -29152-C02-01 and the MAT2011-29152-C02-02 projects from the Ministerio de Economía y Competitividad (MINECO/FEDER) from Spain.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Electrochemical reduction of Graphene Oxide on biomedical grade CoCr alloy

  • García-Argumánez, A.
  • Llorente, Irene
  • Caballero-Calero, Olga
  • González Arias, Zoraida
  • Menéndez López, Rosa María
  • Escudero Rincón, María Lorenza
  • García-Alonso, M. C.
In the present work, the characterization of Electrochemically Reduced Graphene Oxide (ErGO) films on a biomedical grade CoCr alloy has been performed. The direct electrodeposition process was carried out by means of two electrochemical techniques: chronoamperometry and cyclic voltammetry experiments, both taking into account the influence of oxygen in the solution. Characterization of the resulting ErGO films on CoCr alloys was carried out by SEM, AFM, Raman spectroscopy and XPS. Both electrochemical reduction procedures led to the deposition of graphene-based films on the CoCr surfaces after the partial removal of the oxygenated functional groups present in the graphene network of the starting material. The deconvolution of the XPS high-resolution C1s and O1s spectra mainly showed Csp2 bonding and the presence of CO and CO residual groups covering the CoCr surface. Moreover, the ErGO films that were stacked on the CoCr surfaces exhibited non-uniform thickness reaching values corresponding to the presence of 80 layers of the graphene material. In addition, Raman spectroscopy revealed a certain structural disorder in the ErGO films deposited by means of the different electrochemical techniques investigated. This fact was more evident on the film from the chronoamperometric experiments, as the fastest electrochemical reduction rate provided by the application of a high reduction potential (−2.1 Vvs. Ag/AgCl) could induce the development of defects in the resulting film, so the peaks corresponding to the CoCr substrate could be observed., This work was supported by the Spanish Ministry of Economy, Industry and Competitiveness [MAT2015-67750-C3-1-R]., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Otros (Other)

Macrophage Biocompatibility of CoCr Wear Particles Produced under Polarization in Hyaluronic Acid Aqueous Solution

  • Pérez-Maceda, B. T.
  • López-Fernández, M.E.
  • Díaz, Iván
  • Kavanaugh, Aaron
  • Billi, Fabrizio
  • Escudero Rincón, María Lorenza
  • García-Alonso, M. C.
  • Lozano, R.M.
Macrophages are the main cells involved in inflammatory processes and in the primary response to debris derived from wear of implanted CoCr alloys. The biocompatibility of wear particles from a high carbon CoCr alloy produced under polarization in hyaluronic acid (HA) aqueous solution was evaluated in J774A.1 mouse macrophages cultures. Polarization was applied to mimic the electrical interactions observed in living tissues. Wear tests were performed in a pin-on-disk tribometer integrating an electrochemical cell in phosphate buffer solution (PBS) and in PBS supplemented with 3 g/L HA, an average concentration that is generally found in synovial fluid, used as lubricant solution. Wear particles produced in 3 g/L HA solution showed a higher biocompatibility in J774A.1 macrophages in comparison to those elicited by particles obtained in PBS. A considerable enhancement in macrophages biocompatibility in the presence of 3 g/L of HA was further observed by the application of polarization at potentials having current densities typical of injured tissues suggesting that polarization produces an effect on the surface of the metallic material that leads to the production of wear particles that seem to be macrophage-biocompatible and less cytotoxic. The results showed the convenience of considering the influence of the electric interactions in the chemical composition of debris detached from metallic surfaces under wear corrosion to get a better understanding of the biological effects caused by the wear products., Funding: Financial support received through the MAT2015-67750-C3-2-R, MAT2015-67750-C3-1-R, MAT2011-29152-C02-01 and the MAT2011-29152-C02-02 projects from the Ministerio de Economía y Competitividad (MINECO/FEDER) from Spain.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Effect of Heat Treatment on the Electrochemical and Mechanical Behavior of the Ti6Al4V Alloy

  • Chávez-Díaz, Mercedes Paulina
  • Escudero Rincón, María Lorenza
  • Chao, Jesús
  • Arce-Estrada, Elsa Miriam
  • Cabrera-Sierra, Román
The effects of heat treatment on the hardness and electrochemical behavior of the Ti6Al4V alloy were studied. Two heat treatments were performed: one below (800 °C) and the other above (1050 °C) its beta transformation temperature (T= 980 ± 20 °C) and cooled using three conditions: water quenching, normalizing, and furnace. A microstructure observed using Optical Microscopy showed dependence on the heat treatment temperature applied; mainly three microstructures were obtained: martensitic, globular, and lamellar. Besides, alpha and beta phases were characterized by X-ray diffraction (XRD) technique. The Berkovich tests were performed to measure the hardness and reduced modulus (E). The Ti6Al4V alloy treated at 1050 °C and air-cooled exhibited hardness values closer to those of the Ti6Al4V as-received alloy. Electrochemical tests were carried out to analyze the electrochemical behavior after 7-day immersion in Hank’s solution at 37 °C and pH 7.40. Open Circuit Potentials (E) showed less negative values for Ti6Al4V and Ti6Al4V alloys, suggesting ennoblement of these materials. Furthermore, these alloys exhibited an outstanding electrochemical behavior compared to the Ti6Al4V as-received alloy by Electrochemical Impedance Spectroscopy (EIS) technique., The authors thank David Pérez-Risco for sharing his experience and useful advice on Berkovich Nano-indenter at the National Metallurgical Research Center (CENIM-CSIC Madrid, Spain), allowing this work to be carried out. Mercedes Paulina Chávez-Díaz thanks the National Science and Technology Council (CONACyT) for a doctoral fellowship to hold a research stay at CENIM-CSIC. This work was supported by the Government of Spain, through the Ministry of Economy and Competitiveness [MAT2015-67750-C3-1]. Elsa Miriam Arce-Estrada and Román Cabrera-Sierra wish to thank the National Research System (SNI) for the distinction of its members and the stipend received.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Wettability, corrosion resistance, and osteoblast response to reduced graphene oxide on CoCr functionalized with hyaluronic acid

  • Chico, Belén
  • Pérez-Maceda, B. T.
  • San José-Pinilla, Sara
  • Escudero Rincón, María Lorenza
  • García-Alonso, M. C.
  • Lozano, R.M.
14 p.-8 fig.-2 tab. Blanca Teresa Pérez-Maceda who participated actively in this research with great enthusiasm has passed away., The durability of metal–metal prostheses depends on achieving a higher degree of lubrication. The beneficial effect of hyaluronic acid (HA) on the friction and wear of both natural and artificial joints has been reported. For this purpose, graphene oxide layers have been electrochemically reduced on CoCr surfaces (CoCrErGO) and subsequently functionalized with HA (CoCrErGOHA). These layers have been evaluated from the point of view of wettability and corrosion resistance in a physiological medium containing HA. The wettability was analyzed by contact angle measurements in phosphate buffer saline-hyaluronic acid (PBS-HA) solution. The corrosion behavior of functionalized CoCr surfaces was studied with electrochemical measurements. Biocompatibility, cytotoxicity, and expression of proteins related to wound healing and repair were studied in osteoblast-like MC3T3-E1 cell cultures. All of the reported results suggest that HA-functionalized CoCr surfaces, through ErGO layers in HA-containing media, exhibit higher hydrophilicity and better corrosion resistance. Related to this increase in wettability was the increase in the expressions of vimentin and ICAM-1, which favored the growth and adhesion of osteoblasts. Therefore, it is a promising material for consideration in trauma applications, with improved properties in terms of wettability for promoting the adhesion and growth of osteoblasts, which is desirable in implanted materials used for bone repair, Financial support is received through the RTI2018-101506-B-C31 and RTI2018-101506-B-C33 from the Ministerio de Ciencia, Innovación (MICINN/FEDER), and through the MAT2015-67750-C3-2-R, MAT2015-67750-C3-1-R from the Ministerio de Economía y Competitividad (MINECO/FEDER) from Spain., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Implantation of heat treatment Ti6al4v alloys in femoral bone of Wistar rats

  • Chávez-Díaz, Mercedes Paulina
  • Aguado-Henche, Soledad
  • Rubio Yanchuck, Mónica
  • Clemente de Arriba, Celia
  • Cabrera Sierra, Román
  • Escudero Rincón, María Lorenza
  • Hallen, José M.
Two heat treatments were carried out at below (Ti6Al4V) and above (Ti6Al4V) the beta-phase transformation temperature (T = 980 °C), to study the effect of microstructural changes on osseointegration. The alloys were implanted in the femurs of hind legs of Wistar rats for 15, 30, and 60 days. Histology of the femur sections obtained for the first 15 days showed inflammatory tissue surrounding the implants and tissue contraction, which prevented osseointegration in early stages. After 30 days, trabecular bone, reduction of inflammatory tissue around the implants, and osseointegration were observed in Ti6Al4V as received and Ti6Al4V alloys, while osseointegration was detected for the three alloys after 60 days. These results were supported through morphometric studies based on the analysis of Bone Implant Contact (BIC), where there was a larger bone contact after 60 days for the Ti6Al4V alloy; indicating that microstructural features of the Ti6Al4V alloys influence their osseointegration, with the lamellar microstructure (Ti6Al4V), being the most responsive. [Figure not available: see fulltext.]., This work was supported by the Government of Spain, through the Ministry of Economy and Competitiveness RTI2018‐101506‐B‐C31 and MAT2015-67750-C3-1.