Suitability Evaluation of Multipoint Simultaneous CO2 Sampling Wireless Sensors for Livestock Buildings
[EN] The environment in livestock buildings must be controlled to ensure the health
and welfare of both workers and animals, as well as to restrict the emission of pollutants to
the atmosphere. Among the pollutants generated inside these premises, carbon dioxide
(CO2) is of great interest in terms of animal welfare and ventilation control. The use of
inexpensive sensors means that complete systems can be designed with a number of
sensors located around the building. This paper describes a study of the suitability of
multipoint simultaneous CO2 sensors operating in a wireless sensor network, which was
found to operate satisfactorily under laboratory conditions and was found to be the best
alternative for these applications. The sensors showed a highly linear response to CO2
concentrations, ranging from 500 to 5000 ppm. However, individual sensor response was
found to differ, which made it necessary to calibrate each one separately. Sensor precision
ranged between 80 and 110 ppm CO2, and sensor response to register a 95% change in
concentration was estimated at around 5 min. These features mean this type of sensor
network can be used to monitor animal welfare and also for environmental control in
poorly ventilated livestock premises. According to the tests conducted in this study, a
temporal drift may occur and therefore a regular calibration of sensors would be needed., This project was supported by the Vicerrectorado de Investigacion of the UPV (Programa de Apoyo a la Investigacion y Desarrollo, PAID-06-11 Program, Project No. 2843) and the Spanish Government under Projects CTM2011-29691-C02-01 and TIN2011-28435-C03-0. The translation of this paper was funded by the Universitat Politecnica de Valencia, Valencia, Spain.