Hold-up time in gas chromatography. V. Dependence of the retention of n-alkanes on the chromatographic variables in isothermal gas chromatography

  • Quintanilla-López, Jesús Eduardo
  • Lebrón-Aguilar, Rosa
  • García-Domínguez, José Antonio
11 pages, 4 figures, 2 tables, The chromatographic behaviour of n-alkanes and other homologous series in isothermal gas chromatography has been shown to depart from the "linear" representation of the logarithms of the adjusted retention times vs. carbon number. One of the expressions proposed to describe this behaviour is tR(z)=A+exp(B+CzD). In this paper, a regression analysis shows that three of the parameters of the equation depend on different chromatographic variables such as hold-up time, average linear gas velocity, volume and polarity of the stationary phase and temperature of the column. The fourth parameter (D), responsible for the departure from the "linearity", does not depend on any chromatographic variable, and represents a gradual decrease of the contribution of the methylene groups to the general properties of n-alkanes, with no relation to the chromatographic phenomenon., This work has been carried out with financial help from the Direccion General de Investigacion Cientıfica y Tecnica (DGICYT) of Spain, under projects PB94-0218 and PB97-1214. R.L.-A. is grateful to the Ministry of Work for a short duration contract, and J.E.Q.-L. thanks Consejo Superior de Investigaciones ´ Cientıficas (CSIC) for a grant., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Improving the accuracy of Kováts' retention indices in isothermal gas chromatography

  • Lebrón-Aguilar, Rosa
  • Quintanilla-López, Jesús Eduardo
  • García-Domínguez, José Antonio
10 pages, 6 tables, Isothermal Kováts' retention indices are currently reported as whole numbers, and are frequently deduced from a linear least mean squares fitting of the logarithms of adjusted retention times of a number of n-alkanes versus carbon number, following an iterative method that minimises errors. The currently accepted accuracy is about one retention index unit for apolar stationary phases, and lower for polar stationary phases. This paper presents results that show how the accuracy of the retention index may be safely reported to one-tenth of a retention index unit by the use of a non-linear equation, with present day gas chromatographs without electronic flow controllers. Results are presented that prove the correctness of the retention indices found for several substances on one particular capillary column. Hints on the minimum retention times needed to achieve the 0.1 retention index accuracy are mentioned, for retention times recorded in minutes and in seconds. According to results of this paper, two chromatograms, run under the appropriate conditions, are sufficient to obtain the desired accuracy. The method proposed in this paper does not require knowledge of the hold-up time of the chromatogram., The work presented in this paper has been carried out under projects PB97-1214 and PB98-0537-C02´ 01 of the Comision Interministerial de Ciencia y ´ Tecnologıa (CICYT) of Spain. The authors would ´ like to express their gratitude to Asuncion de Diago for her help with some of the experiments and numerical calculations., Peer reviewed