Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Improving the accuracy of Kováts' retention indices in isothermal gas chromatography

  • Lebrón-Aguilar, Rosa
  • Quintanilla-López, Jesús Eduardo
  • García-Domínguez, José Antonio
10 pages, 6 tables, Isothermal Kováts' retention indices are currently reported as whole numbers, and are frequently deduced from a linear least mean squares fitting of the logarithms of adjusted retention times of a number of n-alkanes versus carbon number, following an iterative method that minimises errors. The currently accepted accuracy is about one retention index unit for apolar stationary phases, and lower for polar stationary phases. This paper presents results that show how the accuracy of the retention index may be safely reported to one-tenth of a retention index unit by the use of a non-linear equation, with present day gas chromatographs without electronic flow controllers. Results are presented that prove the correctness of the retention indices found for several substances on one particular capillary column. Hints on the minimum retention times needed to achieve the 0.1 retention index accuracy are mentioned, for retention times recorded in minutes and in seconds. According to results of this paper, two chromatograms, run under the appropriate conditions, are sufficient to obtain the desired accuracy. The method proposed in this paper does not require knowledge of the hold-up time of the chromatogram., The work presented in this paper has been carried out under projects PB97-1214 and PB98-0537-C02´ 01 of the Comision Interministerial de Ciencia y ´ Tecnologıa (CICYT) of Spain. The authors would ´ like to express their gratitude to Asuncion de Diago for her help with some of the experiments and numerical calculations., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

An accurate and easy procedure to obtain isothermal Kováts retention indices in gas chromatography

  • García-Domínguez, José Antonio
  • Lebrón-Aguilar, Rosa
  • Quintanilla-López, Jesús Eduardo
8 pages, 6 tables, Isothermal Kováts retention indices may be used in GC for identification purposes, but they are also useful in characterisation of stationary phases and for studying structural and physico-chemical properties of both the analyte and the stationary phase. They are currently reported as whole numbers with an accuracy of one index unit for non-polar stationary phases. The method recommended for their calculation uses a linear regression model, although non-linear models have also been applied with good results. In both cases, a computer programme and the retention times of a series of n-alkanes that elute correctly and resolved from the other compounds are needed, conditions which cannot always be fulfilled. However, it is possible to calculate retention indices with an accuracy of 0.1 retention index units (0.2 units for packed columns) with the help of only three n-alkanes using just a pocket calculator or a computer spreadsheet. The main requirement is that at least one of the n-alkanes has a retention index differing by no more than one hundred retention index units from that of the analyte being investigated. Examples are given for different stationary phases., The results presented in this paper have been obtained and elabo-rated under the Projects PB98-0537-C02 and BQU2002-03381 ofthe Dirección General de Investigación of Spain. The authors wishto express their thanks to M. A. de Diago for her help in some ofthe numerical calculations., Peer reviewed