Pasar al contenido principal

NOVEL BENDABLE THERMOPLASTIC REBARS FOR IMPROVED DURABILITY AND SUSTAINABILITY OF CONCRETE STRUCTURES

PCI2023-143361

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Afrontar las Prioridades de Nuestro Entorno
Subprograma Subprograma Estatal de Internacionalización
Convocatoria Proyectos Programación Conjunta Internacional
Año convocatoria 2023
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSITAT POLITECNICA DE CATALUNYA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Experimental response of fibre reinforced polymer (FRP) pretensioned concrete beams under 3-point bending tests

  • Ortiz Bernal, Galo Fabian|||0000-0002-9823-1637
  • Oller Ibars, Eva|||0000-0002-0845-3587
  • Marí Bernat, Antonio Ricardo|||0000-0002-0994-0715
The use of fibre-reinforced polymers (FRP) as active reinforcement in prestressed concrete structures remains limited, primarily due to the lack of specific design standards and the scarcity of experimental data. In this context, this study aims to enhance understanding of the flexural behaviour of FRP-prestressed concrete members, without shear reinforcement, when the critical shear region is flexurally cracked. An experimental program comprising 3-point bending tests was conducted on ten simply supported precast concrete beams pretensioned with FRP bars or strands. The investigated parameters were the type of reinforcement material— GFRP bars, CFRP bars, CFCC and steel strands—and the level of prestressing. Almost all beams failed due to a diagonal inclined shear crack. However, in some of them, the active reinforcement was almost reaching its ultimate strength. For most specimens, the lower stiffness of the FRP reinforcement combined with a low prestressing level, led to a pronounced increase in curvature and crack width, and a reduction of the neutral axis depth of up to 75% compared to the uncracked stage. Consequently, their shear capacity decreased to a much greater extent than its flexural capacity, leading to the observed shear failure. This behaviour has been theoretically reproduced by the Compression Chord Capacity Shear Model, combined with a nonlinear flexural analysis to determine the neutral axis depth. Beams prestressed with CFRP bars resisted 16% higher loads than those with GFRP bars at the same prestressing level, while CFCC strands showed performance comparable to steel strands. For CFCC prestressed beams, an increase in prestressing force by 25% resulted in a 23% higher load capacity. Results highlight the critical role of stiffness and prestressing level in ultimate strength and failure mode., The authors want to acknowledge the financial support provided by Spanish Ministry of Science and Innovation (MICIU/AEI/10.13039/501100011033) and by the European Funds for Regional Development in the following projects RTI2018-097314-B-C21, and PCI2023-143361. The first author would like to acknowledge to the Spanish for the PhD grant PRE2019-088919. The authors would like to acknowledge Sireg for their courtesy supplying the different FRP embedded reinforcement used in the experimental programs., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Experimental response of fibre reinforced polymer (FRP) pretensioned concrete beams under 3-point bending tests

  • Ortiz Bernal, Galo Fabian
  • Oller Ibars, Eva
  • Marí Bernat, Antonio Ricardo
The use of fibre-reinforced polymers (FRP) as active reinforcement in prestressed concrete structures remains limited, primarily due to the lack of specific design standards and the scarcity of experimental data. In this context, this study aims to enhance understanding of the flexural behaviour of FRP-prestressed concrete members, without shear reinforcement, when the critical shear region is flexurally cracked. An experimental program comprising 3-point bending tests was conducted on ten simply supported precast concrete beams pretensioned with FRP bars or strands. The investigated parameters were the type of reinforcement material— GFRP bars, CFRP bars, CFCC and steel strands—and the level of prestressing. Almost all beams failed due to a diagonal inclined shear crack. However, in some of them, the active reinforcement was almost reaching its ultimate strength. For most specimens, the lower stiffness of the FRP reinforcement combined with a low prestressing level, led to a pronounced increase in curvature and crack width, and a reduction of the neutral axis depth of up to 75% compared to the uncracked stage. Consequently, their shear capacity decreased to a much greater extent than its flexural capacity, leading to the observed shear failure. This behaviour has been theoretically reproduced by the Compression Chord Capacity Shear Model, combined with a nonlinear flexural analysis to determine the neutral axis depth. Beams prestressed with CFRP bars resisted 16% higher loads than those with GFRP bars at the same prestressing level, while CFCC strands showed performance comparable to steel strands. For CFCC prestressed beams, an increase in prestressing force by 25% resulted in a 23% higher load capacity. Results highlight the critical role of stiffness and prestressing level in ultimate strength and failure mode., The authors want to acknowledge the financial support provided by Spanish Ministry of Science and Innovation (MICIU/AEI/10.13039/501100011033) and by the European Funds for Regional Development in the following projects RTI2018-097314-B-C21, and PCI2023-143361. The first author would like to acknowledge to the Spanish for the PhD grant PRE2019-088919. The authors would like to acknowledge Sireg for their courtesy supplying the different FRP embedded reinforcement used in the experimental programs., Peer Reviewed, Postprint (published version)