Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Bioreceptors' immobilization by hydrogen bonding interactions and differential pulse voltammetry for completely label-free electrochemical biosensors

  • López Marzo, Adaris
  • Mas Torrent, Marta
Label-free electrochemical biosensors show great potential for the development of point-of-care devices (POCDs) for environmental and clinical applications. These sensors operate with shorter analysis times and are more economic than the labelled ones. Here, four completely label-free biosensors without electron transfer mediators were developed for hepatitis B virus (HBV) detection. The approach consisted in (i) the modification of gold surfaces with cysteamine (CT) or cysteine (CS) linkers, (ii) the subsequent antibody (Ab) immobilization, either directly by hydrogen bonding (HB) interactions or by covalent bonds (CB) using additional reagents, and (iii) measuring the biosensor response by electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV). The electrode surfaces at each stage of the modification process were characterised by X-ray photo-electron spectroscopy (XPS) and atomic force microscopy (AFM). The combination of Ab immobilization by HB with the DPV analysis displayed improved repeatability, lower interference to serum matrix and similar limits of detection and quantification than the traditional biosensors that immobilize the Ab via CB and use EIS as readout technique. The Ab immobilization by HB is shown as a simple, efficient and low-cost alternative to CB ones, while DPV was faster and showed better performance than EIS. The CT-HB biosensor displayed the lowest limits of detection and quantification of 0.14 and 0.46 ng/mL, respectively, a 0.46-12.5 ng/mL linear analytical range, and 100% of recovery for 1/10 human serum media during HBV surface antigen detection by DPV. Even, it preserved the initial sensing capability after 7 days of its fabrication., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. This work was supported by the Project CARESS PDC2021-121511-I00 funded by MCIN/AEI/10.13039/501100011033 and the European Union through “NextGeneration EU/PRTR”. The authors also thank funding from the Spanish Government within the research project PID2022-141393OB-I00 and the “Severo Ochoa” Programme for Centers of Excellence in R&D (CEX2023-001263-S). Funding was also provided by the Generalitat de Catalunya (2021 SGR 00443)., With funding from the Spanish government through the ‘Severo Ochoa Centre of Excellence’ accreditation (CEX2023-001263-S)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Electrically Readable Lateral Flow Assay Using Organic Transistors for Diagnostic Applications

  • Ortiz Aguayo, María Jesús
  • Martínez Domingo, Carme
  • Gutiérrez, Diego
  • Kos, Dean
  • Mas Torrent, Marta
Electrolyte-gated organic field-effect transistors (EGOFETs) are emerging as powerful, ultrasensitive label-free biosensors, but their applicability as portable diagnostic tools remains constrained by poor microfluidic miniaturization and complex multi-step ex situ assays. Simultaneously, paper-based lateral flow (LF) immunoassays hold significant relevance for integrated diagnostic applications in the market, but are limited by the low sensitivity of optical detection. To address these challenges, a simple EGOFET integrated with LF paper fluidics are reported to obtain a reusable, highly portable, and cost-effective point-of-care (PoC) test with rapid results (≈20–30 min). The test is validated for Human Immunoglobulin G detection, achieving a wide linear range, high selectivity, reproducibility, and a low limit of detection of 0.1 fm. The portability of the system is demonstrated in a designed prototype with a miniaturized electronic reader, operating via an adapted USB-connected smart device. This work fulfills the requirements of low-cost PoC tests and offers a foundation for the next generation of digital LF assays., This work was funded by the MCIN/AEI/10.13039/501100011033/ERDF, UE, with projects SENSATION PID2022-141393OB-I00 and PDC2021-121511-I00, and through the “Severo Ochoa” Programme for Centers of Excellence in R&D (CEX2023-001263-S). The authors also acknowledge funds from the Generalitat de Catalunya (2021-SGR-00443 and 2023 PROD 00118). M.O. acknowledges her FPI fellowship and is enrolled in the UAB Chemistry PhD program. D.K. acknowledges the Beatriu de Pinós postdoctoral programme (AGAUR 2023 BP 00236), funded by the Secretariat of Universities and Research of the Department of Business and Knowledge of the Government of Catalonia, and the Marie Skłodowska-Curie Actions programme of Horizon Europe with project “OPTOCHARGE” (ID: 101066319). Special acknowledgments to Engineer Carlos Villegas for his advice on 3D printing., With funding from the Spanish government through the ‘Severo Ochoa Centre of Excellence’ accreditation (CEX2023-001263-S)., Peer reviewed