Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Square Membrane Resonators Supporting Degenerate Modes of Vibration for High-Throughput Mass Spectrometry of Single Bacterial Cells

  • Sanz-Jiménez, Adrián
  • Ruz Martínez, José Jaime
  • Gil-Santos, Eduardo
  • Malvar, Óscar
  • García-López, Sergio
  • Kosaka, Priscila M.
  • Cano-Tortajada, Álvaro
  • Calleja, Montserrat
  • Tamayo de Miguel, Francisco Javier
In nanomechanical mass spectrometry, sensing devices are commonly placed in the vacuum environment and a stream of analytes is directed toward the sensor surface for measurement. Beam structures, such as double-clamped nanobeams and nanocantilevers, are commonly used due to their low inertial mass and the simplicity of the analytical models for mass extraction. The drawback of such structures is their low capture areas, compromising the capture efficiency and throughput of this technique. Bi-axisymmetric resonators, such as ultrathin square or circular membranes, arise as an optimal geometry to maximize capture efficiency while minimizing the device inertial mass. However, these structures present degenerate mechanical modes, whose frequency perturbations upon analyte adsorption are not well described by commonly used models. Furthermore, prior knowledge of the vibration mode shapes of the sensor is crucial for the correct calculation of the analyte’s mass, and the mode shape of degenerate modes may change significantly after every adsorption event. In this work, we present an accurate analytical theory to describe the effect of mass adsorption on the degenerate modes of square membrane resonators and propose two different methods based on the new theory to update the vibration mode shapes after every adsorption event. Finally, we illustrate the problem experimentally obtaining the mass and adsorption position of individual Escherichia coli K-12 bacterial cells on commercial square silicon nitride membranes fabricated with very small tolerances., This work was partially supported by the European Union’s Horizon 2020 Research and Innovation Program under grant agreement no. 731868 VIRUSCAN, by the ERC CoG grant 681275 “LIQUIDMASS”, and by 101034583-H2020-FETOPEN “VIRAIR”. It has received funding from the Spanish Science and Innovation Ministry through projects AES (DTS21/00136/ISCIII/Unión Europea/FEDER), “CELLBIOPHYS” (PID2021-126993OB-I00/MCIN/AEI/ 10.13039/501100011033/FEDER, UE), “ONCOLIGHT” (PDC2022-133503-I00/MCIN/AEI/10.13039/ 501100011033/European Union/Next Generation EU/ PRTR), “ONCODEEPLASM” (PLEC2021-007892/MCIN/ AEI/10.13039/501100011033/European Union/Next Generation EU/PRTR) and by Comunidad Autónoma de Madrid Y2020/BIO-65194 scCANCER-CM., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Measuring Vibrational Modes in Living Human Cells

  • Puerto Belda, Verónica
  • Ruz Martínez, José Jaime
  • Millá, Carmen
  • Cano-Tortajada, Álvaro
  • Yubero, Marina L.
  • García-López, Sergio
  • Kosaka, Priscila M.
  • Calleja, Montserrat
  • Tamayo de Miguel, Francisco Javier
The question of whether human living cells in physiological conditions exhibit mechanical resonances has remained unresolved for more than 70 years. We here construct a theoretical model to predict how these hypothetical vibration modes of a living cell can modify the stochastic response of a supporting micromechanical resonator. The key signatures that demonstrate the existence of these vibration modes are then searched for experimentally. To this aim, single human breast epithelial cells were attached to the surface of compliant small microcantilevers. Close examination of the frequency spectra of the thermal fluctuations of the microcantilever over a high-frequency range of 1 kHz–1 MHz revealed anomalies that are consistent with our theoretical predictions. We identify the stochastic coupling of the first and third vibration modes of the cell with the torsional and flexural vibration modes of the cantilever, respectively. These mechanical resonances are very broad and are located at 10–30 kHz and 150–180 kHz, respectively. The analysis of the experiments allows us to obtain information on the temporal evolution of several physical properties of the cell, in addition to the resonance frequencies, during the adhesion process—such as the mass, viscoelasticity, and contact area. These results open multiple avenues in our understanding of single cell mechanobiology, vibrational spectrometry of living cells and mechanical destruction of cancerous cells by targeting specific cell frequencies., This work was partially supported by the Spanish Science and Innovation Ministry through Projects No. RTI2018-099369-B-I00 [related Doctoral Fellowship No. (FPI) PRE2019-087448], No. AES (DTS21/00136)/ISCIII/ EU/FEDER, No. “CELLBIOPHYS” (PID2021-126993OBI00/MCIN/AEI/10.13039/501100011033/FEDER, UE), “ONCOLIGHT” (No. PDC2022-133503- I00/MCIN/AEI/ 10.13039/501100011033/European Union/Next Generation EU/PRTR), “ONCODEEPLASM” (No. PLEC2021- 007892/MCIN/AEI/10.13039/501100011033/European Union/Next Generation EU/PRTR), and by Comunidad Autónoma de Madrid No. Y2020/BIO-65194 scCANCERCM. This work has also been supported by the private FERO Foundation and Elena Torres Cancer Association funding. We acknowledge the service from the Micro and Nanofabrication Laboratory, an X-SEM laboratory at IMN-CNM funded by the Comunidad de Madrid (Project No. S2018/NMT-4291 TEC2SPACE) and by MINECO (Project No. CSIC13-4E-1794 with support from FEDER, FSE)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Rapid mechanical phenotyping of breast cancer cells based on stochastic intracellular fluctuations

  • Cano-Tortajada, Álvaro
  • Yubero, Marina L.
  • Millá, Carmen
  • Puerto Belda, Verónica
  • Ruz Martínez, José Jaime
  • Kosaka, Priscila M.
  • Calleja, Montserrat
  • Malumbres, Marcos
  • Tamayo de Miguel, Francisco Javier
Predicting the phenotypic impact of genetic variants and treatments is crucial in cancer genetics and precision oncology. Here, we have developed a noise decorrelation method that enables quantitative phase imaging (QPI) with the capability for label-free noninvasive mapping of intracellular dry mass fluctuations within the millisecond-to-second timescale regime, previously inaccessible due to temporal phase noise. Applied to breast cancer cells, this method revealed regions driven by thermal forces and regions of intense activity fueled by ATP hydrolysis. Intriguingly, as malignancy increases, the cells strategically expand these active regions to satisfy increasing energy demands. We propose parameters encapsulating key information about the spatiotemporal distribution of intracellular fluctuations, enabling precise phenotyping. This technique addresses the need for accurate, rapid functional screening methods in cancer medicine., This work was partially supported by the Spanish Science and Innovation Ministry through projects RTI2018-099369-B-I00 (related doctoral fellowship [FPI] PRE2019-087448), AES (DTS21/00136)/ISCIII/EU/FEDER, “CELLBIOPHYS” (PID2021-126993OB-I00/MCIN/AEI/10.13039/501100011033/FEDER, UE), “ONCOLIGHT” (PDC2022-133503- I00/MCIN/AEI/10.13039/501100011033/European Union/Next Generation EU/PRTR), and “ONCODEEPLASM” (PLEC2021- 007892/MCIN/AEI/10.13039/501100011033/European Union/Next Generation EU/PRTR) and by Comunidad Autónoma de Madrid (Y2020/BIO- 65194 scCANCER-CM). This work has also been supported by private FERO Foundation and Elena Torres Cancer Association funding. We acknowledge the service from the Micro and Nanofabrication Laboratory and X-SEM laboratory at IMN-CNM funded by the Comunidad Autónoma de Madrid (project S2018/NMT-4291 TEC2SPACE) and by MINECO (project CSIC13-4E-1794 with support from FEDER, FSE)., Peer reviewed