Pasar al contenido principal

LENGUAS ELECTRONICAS CON SISTEMAS DE RECONOCIMIENTO MEJORADOS

PID2019-107102RB-C21

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2019
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD AUTONOMA DE BARCELONA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 11
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Optimization of Sensors to be Used in a Voltammetric Electronic Tongue Based on Clustering Metrics

  • Sarma, Munmi
  • Romero, Noelia
  • Cetó, Xavier|||0000-0003-1589-6076
  • Valle, Manel del|||0000-0002-1032-8611
Herein we investigate the usage of principal component analysis (PCA) and canonical variate analysis (CVA), in combination with the F factor clustering metric, for the a priori tailored selection of the optimal sensor array for a given electronic tongue (ET) application. The former allows us to visually compare the performance of the different sensors, while the latter allows us to numerically assess the impact that the inclusion/removal of the different sensors has on the discrimination ability of the ET. The proposed methodology is based on the measurement of a pure stock solution of each of the compounds under study, and the posterior analysis by PCA/CVA with stepwise iterative removal of the sensors that demote the clustering when retained as part of the array. To illustrate and assess the potential of such an approach, the quantification of paracetamol, ascorbic acid, and uric acid mixtures were chosen as the study case. Initially, an array of eight different electrodes was considered, from which an optimal array of four sensors was derived to build the quantitative ANN model. Finally, the performance of the optimized ET was benchmarked against the results previously reported for the analysis of the same mixtures, showing improved performance.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Determination of Chemical Oxygen Demand (COD) Using Nanoparticle-Modified Voltammetric Sensors and Electronic Tongue Principles

  • Wang, Qing
  • Valle, Manel del|||0000-0002-1032-8611
This manuscript reports the use of nanoparticle-modified voltammetric sensors for the rapid and green determination of chemical oxygen demand in river waters and waters from agricultural waste. Four different variants of modified electrodes have been prepared: CuO nanoparticles electrogenerated over Cu and covered with Nafion film (CuO/Cu-Nf), and graphite-epoxy composites modified with Cu, CuO, and Cu-Ni alloy nanoparticles. The response features of these electrodes were assessed by calibrating them vs. glucose, glycine, ethyleneglycol, and hydrogenphtalate in alkaline media, as samples providing different difficulty in their (bio)degradation characteristics. The most sensitive electrode was demonstrated to be the (CuO/Cu-Nf) electrode, with an LOD of 12.3 mg O2·L-1. The joint information provided by the sensor array showed the ability of estimating both the organic load and the type of sample in terms of difficulty of degradation, in what can be named an intelligent sensor assembly.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Sensors as green tools in analytical chemistry

  • Valle, Manel del|||0000-0002-1032-8611
This article comments on green aspects of (bio)chemical sensors for qualitative and quantitative analysis applications. First, the aspects that connect chemical sensors and biosensors with the main trends of green analytical chemistry are discussed. To continue, a set of paradigmatic examples of sustainable assays pertaining to the (bio)sensing field have been selected and explored in some of their variants. These are the use of a smartphone camera together with a microfluidic paper platform to perform colorimetric or fluorometric assays, the use of the portable glucose meter as transducer for a variety of (bio)assays different of glucose, or the coupling of sensor arrays with advanced chemometric processing for smart sensing (electronic noses and electronic tongues).
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Graphene for the Building of Electroanalytical Enzyme-Based Biosensors, application to the Inhibitory Detection of Emerging Pollutants

  • Bonet-SanEmeterio, Marta|||0000-0002-5076-8136
  • Felipe Montiel, Noelia|||0000-0002-0416-0373
  • Valle, Manel del|||0000-0002-1032-8611
Graphene and its derivates offer a wide range of possibilities in the electroanalysis field, mainly owing to their biocompatibility, low-cost, and easy tuning. This work reports the development of an enzymatic biosensor using reduced graphene oxide (RGO) as a key nanomaterial for the detection of contaminants of emerging concern (CECs). RGO was obtained from the electrochemical reduction of graphene oxide (GO), an intermediate previously synthesized in the laboratory by a wet chemistry top-down approach. The extensive characterization of this material was carried out to evaluate its proper inclusion in the biosensor arrangement. The results demonstrated the presence of GO or RGO and their correct integration on the sensor surface. The detection of CECs was carried out by modifying the graphene platform with a laccase enzyme, turning the sensor into a more selective and sensitive device. Laccase was linked covalently to RGO using the remaining carboxylic groups of the reduction step and the carbodiimide reaction. After the calibration and characterization of the biosensor versus catechol, a standard laccase substrate, EDTA and benzoic acid were detected satisfactorily as inhibiting agents of the enzyme catalysis obtaining inhibition constants for EDTA and benzoic acid of 25 and 17 mmol·L-1, respectively, and a maximum inhibition percentage of the 25% for the EDTA and 60% for the benzoic acid.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

A novel electronic tongue using electropolymerized molecularly imprinted polymers for the simultaneous determination of active pharmaceutical ingredients

  • Wang, Mingyue
  • Cetó, Xavier|||0000-0003-1589-6076
  • Valle, Manel del|||0000-0002-1032-8611
The combination of chemometrics and electrochemical sensors modified with molecularly imprinted polymers (MIPs) towards the development of MIP-based electronic tongues (ETs) was explored herein. To demonstrate the potential of such an approach, the simultaneous determination of paracetamol, ascorbic acid and uric acid mixtures in pharmaceutical samples was evaluated. To this aim, MIP-based sensors for the different compounds were prepared by in situ electropolymerization of pyrrole in the presence of p-toluenesulfonate anion (pTS), which acted as functional doping ion of the polypyrrole (PPy) MIP backbone. Morphological characterization of the MIPs was done by scanning electron microscopy (SEM), while functionalization of the electrodes was monitored electrochemically. Under the optimized measuring conditions, the developed sensors showed a good performance, with good linearity at the μM level (R.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Voltammetric sensing using an array of modified SPCE coupled with machine learning strategies for the improved identification of opioids in presence of cutting agents

  • Ortiz, Dionisia|||0000-0002-5637-8120
  • De Wael, Karolien|||0000-0003-4495-0748
  • Valle, Manel del|||0000-0002-1032-8611
This work reports the use of modified screen-printed carbon electrodes (SPCEs) for the identification of three drugs of abuse and two habitual cutting agents, caffeine and paracetamol, combining voltammetric sensing and chemometrics. In order to achieve this goal, codeine, heroin and morphine were subjected to Square Wave Voltammetry (SWV) at pH 7, in order to elucidate their electrochemical fingerprints. The optimized SPCEs electrode array, which have a differentiated response for the three oxidizable compounds, was derived from Carbon, Prussian blue, Cobalt (II) phthalocyanine, Copper (II) oxide, Polypyrrole and Palladium nanoparticles ink-modified carbon electrodes. Finally, Principal Component Analysis (PCA) coupled with Silhouette parameter assessment was used to select the most suitable combination of sensors for identification of drugs of abuse in presence of cutting agents.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Resolution of opiate illicit drugs signals in the presence of some cutting agents with use of a voltammetric sensor array and machine learning strategies

  • Ortiz, Dionisia|||0000-0002-5637-8120
  • Cetó, Xavier|||0000-0003-1589-6076
  • De Wael, Karolien|||0000-0003-4495-0748
  • Valle, Manel del|||0000-0002-1032-8611
In the present work, the resolution and quantification of mixtures of different opiates compounds in the presence of common cutting agents using an electronic tongue (ET) is evaluated. More specifically, ternary mixtures of heroin, morphine and codeine were resolved in the presence of caffeine and paracetamol. To this aim, an array of three carbon screen-printed electrodes were modified with different ink-like solutions of graphite, cobalt (II) phthalocyanine and palladium, and their responses towards the different drugs were characterized by means of square wave voltammetry (SWV). Developed sensors showed a good performance with good linearity at the µM level, LODs between 1.8 and 5.33 µM for the 3 actual drugs, and relative standard deviation (RSD) ca. 2% for over 50 consecutive measurements. Next, a quantitative model that allowed the identification and quantification of the individual substances from the overlapped voltammograms was built using partial least squares regression (PLS) as the modelling tool. With this approach, quantification of the different drugs was achieved at the μM level, with a total normalized root mean square error (NRMSE) of 0.084 for the test subset.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Dummy molecularly imprinted polymers using dnp as a template molecule for explosive sensing and nitroaromatic compound discrimination

  • Herrera-Chacon, Anna|||0000-0002-6169-147X
  • González-Calabuig, Andreu|||0000-0002-6325-138X
  • Valle, Manel del|||0000-0002-1032-8611
This work reports a rapid, simple and low-cost voltammetric sensor based on a dummy molecularly imprinted polymer (MIP) that uses 2,4-dinitrophenol (DNP) as a template for the quantification of 2,4,6-trinitrotoluene (TNT) and DNP, and the identification of related substances. Once the polymer was synthesised by thermal precipitation polymerisation, it was integrated onto a graphite epoxy composite (GEC) electrode via sol-gel immobilisation. Scanning electron microscopy (SEM) was performed in order to characterise the polymer and the sensor surface. Responses towards DNP and TNT were evaluated, displaying a linear response range of 1.5 to 8.0 µmol L for DNP and 1.3 to 6.5 µmol L for TNT; the estimated limits of detection were 0.59 µmol L and 0.29 µmol L, for DNP and TNT, respectively. Chemometric tools, in particular principal component analysis (PCA), demonstrated the possibilities of the MIP-modified electrodes in nitroaromatic and potential interfering species discrimination with multiple potential applications in the environmental field.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Electronic tongue applications for wastewater and soil analysis

  • Cetó, Xavier|||0000-0003-1589-6076
  • Valle, Manel del|||0000-0002-1032-8611
Assessment of water and soil quality is critical for the health, economy, and sustainability of any community. The release of a range of life-threatening pollutants from agriculture, industries, and the residential communities themselves into the different water resources and soil requires of analytical methods intended for their detection. Given the challenge that represents coping with the monitoring of such a diverse and large number of compounds (with over 100,000 chemicals registered, yet in continuous increase), holistic solutions such as electronic tongues (ETs) are emerging as a promising tool for a sustainable, simple, and green monitoring of soil and water resources. In this direction, this review aims to present and critically provide an overview of the basic concepts of ETs, followed by some relevant applications recently reported in the literature in environmental analysis, more specifically, the monitoring of water and wastewater, their quality and the detection of water pollutants as well as soil analysis.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Quantitative Estimation of COD Values from an Array of Metal Nanoparticle Modified Electrodes and Artificial Neural Networks †

  • Wang, Qing
  • Cetó, Xavier|||0000-0003-1589-6076
  • Valle, Manel del|||0000-0002-1032-8611
Water quality monitoring has become critical in modern societies in multiple areas and at different stages. In this regard, chemical oxygen demand (COD) has become a key index in water testing, as it readily allows the determination of its overall quality and the presence of organic contaminants. However, conventional COD determination presents several drawbacks in view of the use of toxic reagents and possible interferences. The electrochemical determination of COD can be an alternative with many advantages, especially if using an array of sensors. Herein, the use of an electronic tongue (ET) for the estimation of COD was explored. The proposed ET was formed by an array of five voltammetric electrodes modified with different metal nanoparticles. An artificial neural network (ANN) model was built based on the responses of the array towards glucose and glycine as standards. This model was then used with real and spiked water samples, and the results compared to the electrochemical calibration and the commercial COD colorimetric methods. While the COD values of the real samples were low and outside the range of the ANN model, a satisfactory prediction for the spiked samples was achieved, showing a good agreement with the reference colorimetric method, that was better than the performance of the conventional electrochemical calibration method.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Analysis of spices & herbs and its phenolic content by means of an electronic tongue

  • Cetó, Xavier|||0000-0003-1589-6076
  • Sarma, Munmi
  • Valle, Manel del|||0000-0002-1032-8611
The drying process to which herbs and spices are submitted has a significant impact on the flavour and quality of those as many compounds might be degraded or transformed. This is especially relevant for most aromatic and bioactive compounds (e.g., phenolic compounds), which values have been reported to diminish during the drying process. In this direction, herein we explore the usage of an electronic tongue (ET) as a tool to assist on the monitoring of herbs and spices quality. The proposed approach is based on the use of a simple extraction method prior to the analysis of the samples with an array of voltammetric sensors in combination with pattern-recognition methods. Firstly, a partial least squares regression (PLS) model was built, which allowed the quantification of the total phenolic content (R.