Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Towards the development of a portable device based on modified-voltammetric sensors for the detection of illicit drugs and seized samples

  • Cetó, Xavier|||0000-0003-1589-6076
  • Truta, Florina Maria
  • Drăgan, Ana-Maria|||0000-0002-1488-5917
  • Rodríguez-Franch, Elena|||0000-0003-3638-9583
  • Tertis, Mihaela|||0000-0003-2572-6724
  • Sánchez-Pereña, Ángela
  • Comellas-Tena, Sara
  • Cristea, Cecilia|||0000-0002-4158-3324
  • Valle, Manel del|||0000-0002-1032-8611
Illicit drugs are a global burden, not only for society, but also for the various control authorities for which its rapid on-site detection remains a challenge. In this context, the potential of a voltammetric electronic tongue (ET) for the analysis of different drugs is evaluated herein. Concretely, the discrimination and identification of cocaine, heroin, 3,4-Methylenedioxymethamphetamine (MDMA), methamphetamine and ketamine in self-prepared and real samples were attempted. For its analysis, an array of three carbon-based screen-printed electrodes (SPE) was prepared, and their responses towards the different drugs and some of the more common cutting agents and adulterants were assessed by means of square wave voltammetry (SWV). To this aim, a tiny amount (ca. 3 mg) of the drug powder was added to the electrochemical cell containing phosphate buffer (pH 12), shaken, and measured directly without any other pre-treatment than its dilution. Next, to identify their characteristic fingerprint, obtained voltammograms were submitted to linear discriminant analysis (LDA), which allowed to correctly identify the different drugs regardless of the presence of the different cutting agents and other possible interfering compounds, or their concentration. Satisfactory results were obtained both for the synthetic and the "street" seized samples, with a classification rate of 100 % for the external test subset of the latter (n = 10).
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Voltammetric sensing using an array of modified SPCE coupled with machine learning strategies for the improved identification of opioids in presence of cutting agents

  • Ortiz, Dionisia|||0000-0002-5637-8120
  • De Wael, Karolien|||0000-0003-4495-0748
  • Valle, Manel del|||0000-0002-1032-8611
This work reports the use of modified screen-printed carbon electrodes (SPCEs) for the identification of three drugs of abuse and two habitual cutting agents, caffeine and paracetamol, combining voltammetric sensing and chemometrics. In order to achieve this goal, codeine, heroin and morphine were subjected to Square Wave Voltammetry (SWV) at pH 7, in order to elucidate their electrochemical fingerprints. The optimized SPCEs electrode array, which have a differentiated response for the three oxidizable compounds, was derived from Carbon, Prussian blue, Cobalt (II) phthalocyanine, Copper (II) oxide, Polypyrrole and Palladium nanoparticles ink-modified carbon electrodes. Finally, Principal Component Analysis (PCA) coupled with Silhouette parameter assessment was used to select the most suitable combination of sensors for identification of drugs of abuse in presence of cutting agents.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Resolution of opiate illicit drugs signals in the presence of some cutting agents with use of a voltammetric sensor array and machine learning strategies

  • Ortiz, Dionisia|||0000-0002-5637-8120
  • Cetó, Xavier|||0000-0003-1589-6076
  • De Wael, Karolien|||0000-0003-4495-0748
  • Valle, Manel del|||0000-0002-1032-8611
In the present work, the resolution and quantification of mixtures of different opiates compounds in the presence of common cutting agents using an electronic tongue (ET) is evaluated. More specifically, ternary mixtures of heroin, morphine and codeine were resolved in the presence of caffeine and paracetamol. To this aim, an array of three carbon screen-printed electrodes were modified with different ink-like solutions of graphite, cobalt (II) phthalocyanine and palladium, and their responses towards the different drugs were characterized by means of square wave voltammetry (SWV). Developed sensors showed a good performance with good linearity at the µM level, LODs between 1.8 and 5.33 µM for the 3 actual drugs, and relative standard deviation (RSD) ca. 2% for over 50 consecutive measurements. Next, a quantitative model that allowed the identification and quantification of the individual substances from the overlapped voltammograms was built using partial least squares regression (PLS) as the modelling tool. With this approach, quantification of the different drugs was achieved at the μM level, with a total normalized root mean square error (NRMSE) of 0.084 for the test subset.
Dipòsit Digital de Documents de la UAB
Publicación Capítulo o parte de un libro (BookPart)

Experiences in the detection of drugs of abuse in smuggling seizures and forensic samples using electronic tongue principles

  • Cetó, Xavier|||0000-0003-1589-6076
  • Bonet-SanEmeterio, Marta|||0000-0002-5076-8136
  • Ortiz, Dionisia|||0000-0002-5637-8120
  • Rodriguez-Franch, E.
  • Valle, Manel del|||0000-0002-1032-8611
The application of voltammetric sensors to the analysis of illicit drugs in combination with different chemometric tools to achieve their identification and quantification is explored herein. The aim is to process the whole voltammograms obtained from different sensors as a unique profile, and analyze those with the aid of pattern recognition methods that allow the extraction of a characteristic fingerprint, rather than focusing on the oxidation peaks associated to each of the drugs. To this aim, different arrays of electrodes were prepared to analyzed samples employing square wave voltammetry (SWV). Next, identification of different drugs was achieved by means of principal component analysis (PCA) and linear discriminant analysis (LDA), while their quantification was attained by partial least squares (PLS) modelling.