Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Towards the development of a portable device based on modified-voltammetric sensors for the detection of illicit drugs and seized samples

  • Cetó, Xavier|||0000-0003-1589-6076
  • Truta, Florina Maria
  • Drăgan, Ana-Maria|||0000-0002-1488-5917
  • Rodríguez-Franch, Elena|||0000-0003-3638-9583
  • Tertis, Mihaela|||0000-0003-2572-6724
  • Sánchez-Pereña, Ángela
  • Comellas-Tena, Sara
  • Cristea, Cecilia|||0000-0002-4158-3324
  • Valle, Manel del|||0000-0002-1032-8611
Illicit drugs are a global burden, not only for society, but also for the various control authorities for which its rapid on-site detection remains a challenge. In this context, the potential of a voltammetric electronic tongue (ET) for the analysis of different drugs is evaluated herein. Concretely, the discrimination and identification of cocaine, heroin, 3,4-Methylenedioxymethamphetamine (MDMA), methamphetamine and ketamine in self-prepared and real samples were attempted. For its analysis, an array of three carbon-based screen-printed electrodes (SPE) was prepared, and their responses towards the different drugs and some of the more common cutting agents and adulterants were assessed by means of square wave voltammetry (SWV). To this aim, a tiny amount (ca. 3 mg) of the drug powder was added to the electrochemical cell containing phosphate buffer (pH 12), shaken, and measured directly without any other pre-treatment than its dilution. Next, to identify their characteristic fingerprint, obtained voltammograms were submitted to linear discriminant analysis (LDA), which allowed to correctly identify the different drugs regardless of the presence of the different cutting agents and other possible interfering compounds, or their concentration. Satisfactory results were obtained both for the synthetic and the "street" seized samples, with a classification rate of 100 % for the external test subset of the latter (n = 10).
Dipòsit Digital de Documents de la UAB
Publicación Artículo de revisión (ReviewArticle)

The Personal Glucose Meter as the Measurement Principle in Point-of-Care Applications

  • Cano, Mònica
  • Valle, Manel del|||0000-0002-1032-8611
A personal glucose meter (PGM) is a medical device that measures blood glucose levels and can be found worldwide. Owing to their sensitivity, simplicity, portability, and low cost, PGMs stand as one of the most frequently utilized analytical methods. This work reviews the different applied methodologies for detecting analytes other than glucose employing a PGM and how it can be incorporated for point-of-care diagnosis needs. To visualize the variants, first, a classification is made according to the biorecognition elements used (aptamers, antibodies, etc.), and where the determination of different analytes is done through the glucose signal using different glucose-generating enzymes such as invertase or glucosidase. Transduction can also be based on the use of nanocarriers that generally encapsulate glucose, although it is also possible to find a combination of the two aforementioned strategies. The PGM can also be used for the direct detection of interfering substances of the biosensor, such as NADH or paracetamol. Lastly, we discuss how a PGM might have been implemented to detect COVID-19 and how it could be used on a massive scale for the point-of-care diagnosis of a pandemic.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Electronic Tongue Based on Laser-Induced Graphene Electrodes for Monitoring Ions in Aqueous Media

  • Hensel, Rafael C.|||0000-0001-7060-6604
  • Cetó, Xavier|||0000-0003-1589-6076
  • Oliveira, Osvaldo N.|||0000-0002-5399-5860
  • Valle, Manel del|||0000-0002-1032-8611
This work describes the use of a portable 450 nm wavelength laser system to fabricate an electronic tongue (e-tongue) comprising an array of potentiometric laser-induced graphene (LIG) sensors on polyimide. The sensing units were modified with ion-selective polymer membranes for the detection of Ca , Na, and K. The sensors exhibited pseudo-Nernstian behavior, with sensitivities of 32.7 ± 0.8, 63 ± 3, and 52 ± 2 mV/dec for Ca , Na, and K, respectively, and limits of detection of 4.5 μM for Ca , 606 μM for Na, and 66 μM for K. The qualitative response of the e-tongue was evaluated using principal component analysis (PCA), which allowed a clear distinction between monovalent and divalent ions based on the first two principal components. Discrimination among the three ions at concentrations of 20 μM, 220 μM, and 4.0 mM was achieved using the K-means clustering algorithm, with a silhouette coefficient of 0.946, close to the ideal value. Quantitative analysis using artificial neural networks (ANNs) was applied to ternary mixtures of the three ions, enabling simultaneous and accurate prediction of individual ion concentrations down to 10 μM. Furthermore, we demonstrate the capability of the e-tongue to provide reliable measurements even at trace ion concentrations in mineral water samples, confirming its suitability for precise and sensitive ion monitoring in complex, real-world applications.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Resolution of Glycerol, Ethanol and Methanol Employing a Voltammetric Electronic Tongue

  • de Oliveira, João Pedro Jenson|||0000-0003-1355-2886
  • Bonet-SanEmeterio, Marta|||0000-0002-5076-8136
  • Cardoso de Sá, Acelino|||0000-0002-9811-4879
  • Cetó, Xavier|||0000-0003-1589-6076
  • Lataro Paim, Leonardo|||0000-0002-5113-6376
  • Valle, Manel del|||0000-0002-1032-8611
This paper reports the use of nanoparticles (NPs)-modified voltammetric sensors for the rapid determination of glycerol in the presence of ethanol and methanol, which are used in the transesterification reaction of biodiesel production. Two different modified electrodes have been prepared to form the electronic tongue (ET): copper hexacyanoferrate NPs obtained by chemical synthesis and mixed into graphite/epoxy (GEC) electrode, and nickel hydroxide NPs electrodeposited in reduced graphene oxide onto a GEC electrode. The response characteristics of these electrodes were first evaluated by building the respective calibration against glycerol, ethanol, and methanol. The electrodes demonstrated good stability during their analytical characterization, while principal component analysis confirmed the differentiated response against the different alcohols. Finally, the quantification of mixtures of these substances was achieved by a genetic algorithm-artificial neural networks (GA-ANNs) model, showing satisfactory agreement between expected and obtained values.