Pasar al contenido principal

DATOS OPERACIONALES ENERGETICOS Y METEOROLOGICOS PARA SISTEMAS FOTOVOLTAICOS

PID2019-108953RB-C21

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2019
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE CADIZ

Resultados relacionados

Resultados totales (Incluyendo duplicados): 13
Encontrada(s) 1 página(s)

Helvia. Repositorio Institucional de la Universidad de Córdoba
Publicación Artículo científico (JournalArticle)

Implementation and Characterization of a High-Precision Monitoring System for Photovoltaic Power Plants Using Self-Made Phasor Measurement Units, Implementación y caracterización de un sistema de monitoreo de alta precisión para plantas fotovoltaicas utilizando unidades de medición fasorial (PMU) de fabricación propia

  • Arenas Ramos, Victoria
  • Pallarés López, Víctor
  • Real Calvo, Rafael Jesús
  • González Redondo, Miguel Jesús
  • Santiago Chiquero, Isabel
The increasing integration of photovoltaic (PV) plants into the power grid presents an ongoing challenge to prevent the instability caused by atmospheric conditions from affecting the power distribution network. To adequately control the network and implement such techniques, monitoring has been considerably improved in recent years. Due to the vast number of measurements generated, efficient management of this data has become a significant challenge. This article outlines a procedure used for simultaneously storing synchronized measured data from phasor measurement units (PMUs) and PMU-like data from acquisition data acquisition (DAQ) devices through self-made extended-PMUs (ePMUs). Throughout this article, a communication and storage environment that complies with the IEEE C37.118.2 standard for Synchrophasor Data Transfer for Power Systems will be characterized based on criteria established in the IEC 61850-90-5 standard for power utility automation. In addition, it justifies the chosen storage method through a comprehensive study of data volume and reading accessibility. The procedure and the ePMUs have been experimentally validated in field tests in two grid-connected PV plants. The procedure was proven to be valid for quasi-real-time applications for data registered and sent both in a local area network (LAN) and a wide area network (WAN). Thanks to the dataframes synchronize up to the millisecond, data can also be studied offline seamlessly.
RODIN. Repositorio de Objetos de Docencia e Investigación de la Universidad de Cádiz
Publicación Artículo científico (JournalArticle)

Site Characterization Index for Continuous Power Quality Monitoring Based on Higher-order Statistics

  • Florencias Oliveros, Olivia
  • González de la Rosa, Juan José
  • Sierra Fernández, José María
  • Agüera Pérez, Agustín
  • Espinosa Gavira, Manuel Jesús
  • Palomares Salas, José Carlos
The high penetration of distributed generation (DG) has set up a challenge for energy management and consequently for the monitoring and assessment of power quality (PQ). Besides, there are new types of disturbances owing to the uncontrolled connections of non-linear loads. The stochastic behaviour triggers the need for new holistic indicators which also deal with big data of PQ in terms of compression and scalability so as to extract the useful information regarding different network states and the prevailing PQ disturbances for future risk assessment and energy management systems. Permanent and continuous monitoring would guarantee the report to claim for damages and to assess the risk of PQ distortions. In this context, we propose a measurement method that postulates the use of two-dimensional (2D) diagrams based on higher-order statistics (HOSs) and a previous voltage quality index that assesses the voltage supply waveform in a continous monitoring campaign. Being suitable for both PQ and reliability applications, the results conclude that the inclusion of HOS measurements in the industrial metrological reports helps characterize the deviations of the voltage supply waveform, extracting the individual customers' pattern fingerprint, and compressing the data from both time and spatial aspects. The method allows a continuous and robust performance needed in the SG framework. Consequently, the method can be used by an average consumer as a probabilistic method to assess the risk of PQ deviations in site characterization., This work was supported by the Spanish Ministry of Science and Innovation (Statal Agency for Research), and the EU (AEI/FEDER/UE) via project PID2019-108953RB-C21 Strategies for Aggregated Generation of Photovoltaic Plants: Energy and Meteorological Operational Data (SAGPVEMOD), and the precedent TEC2016-77632-C3-3-R.
RODIN. Repositorio de Objetos de Docencia e Investigación de la Universidad de Cádiz
Publicación Artículo científico (JournalArticle)

The potential of publicly available weather forecasts for market operations in aggregated photovoltaic plants

  • Agüera Pérez, Agustín
  • Espinosa Gavira, Manuel Jesús
  • Palomares Salas, José Carlos
  • Sierra Fernández, José María
  • Florencias Oliveros, Olivia
  • González de la Rosa, Juan José
Uncertainty in solar generation forecasts affects electricity market operations, forcing producers to bid conservatively and, consequently, reducing the amount of solar energy fed into the grid. This study analyses the potential of aggregated forecasts to reduce the errors of energy generation in medium-sized PV plants. To this objective, publicly available forecasts from the Global Forecasting System were processed with a basic neural network to generate hourly energy forecasts for individual PV plants of 1.1 MW and for the aggregated production of three of them (3.3 MW). The validation was carried out considering typical day-ahead and intraday market horizons, two zones with different atmospheric complexity, and discerning three types of days in terms of the received irradiation. Results show that the aggregation of forecasts would be beneficial as a general strategy in all cases, but especially in the zone of complex atmospheric dynamics and for the day-ahead horizons (36-42 h).
RODIN. Repositorio de Objetos de Docencia e Investigación de la Universidad de Cádiz
Publicación Artículo científico (JournalArticle)

Statistical Dataset and Data Acquisition System for Monitoring the Voltage and Frequency of the Electrical Network in an Environment Based on Python and Grafana

  • Fernández Morales, Javier
  • González de la Rosa, Juan José
  • Sierra Fernández, José María
  • Espinosa Gavira, Manuel Jesús
  • Florencias Oliveros, Olivia
  • Agüera Pérez, Agustín
  • Palomares Salas, José Carlos
  • Remigio Carmona, Paula
This article presents a unique dataset, from a public building, of voltage data, acquired using a hybrid measurement solution that combines Python (TM) for acquisition and Grafana (TM) for results representation. This study aims to benefit communities, by demonstrating how to achieve more efficient energy management. The study outlines how to obtain a more realistic vision of the quality of the supply, that is oriented to the monitoring of the state of the network; this should allow for better understanding, which should in turn enable the optimization of the operation and maintenance of power systems. Our work focused on frequency and higher order statistical estimators which, combined with exploratory data analysis techniques, improved the characterization of the shape of the stress signal. These techniques and data, together with the acquisition and monitoring system, present a unique combination of low-cost measurement solutions, which have the underlying benefit of contributing to industrial benchmarking. Our study proposes an effective and versatile system, which can do acquisition, statistical analysis, database management and results representation in less than a second. The system offers a wide variety of graphs to present the results of the analysis, so that the user can observe them and identify, with relative ease, any anomalies in the supply which could damage the sensitive equipment of the correspondent installation. It is a system, therefore, that not only provides information about the power quality, but also significantly contributes to the safety and maintenance of the installation. This system can be practically realized, subject to the availability of internet access.
RODIN. Repositorio de Objetos de Docencia e Investigación de la Universidad de Cádiz
Publicación Artículo científico (JournalArticle)

Characterization of the Hydropower Inlet Effect on the Electric Network Frequency

  • Álvarez Higueruela, Jesús
  • Gutiérrez Villalba, Francisco José
  • Sierra Fernández, José María
  • González de la Rosa, Juan José
  • Florencias Oliveros, Olivia
  • Palomares Salas, José Carlos
  • Agüera Pérez, Agustín
  • Espinosa Gavira, Manuel Jesús
One of the challenges posed by renewable energies is the stabilization of parameters related to the quality of electrical energy. This study demonstrates the existence of a relationship between input blocks of hydropower and the variation of the fundamental frequency of the electricity grid. By mapping production data provided by the Spanish Electric Network with frequency measured in the laboratory, it is shown that gradients of hydropower are correlated with frequency fluctuations for certain characteristic times. Considering hourly instances of energy input, the study compares two methods for calculating hydropower gradients (linear regression and pseudo-linear regression) and two methods for calculating local frequency extrema (the “specular inertia” method and analysis by comparison with the moving average) in order to corroborate the results., 13 páginas
RODIN. Repositorio de Objetos de Docencia e Investigación de la Universidad de Cádiz
Publicación Artículo científico (JournalArticle)

Meteorological contexts in the analysis of cloud-induced photovoltaic transients: A review

  • Agüera Pérez, Agustín
  • Espinosa Gavira, Manuel Jesús
  • Palomares Salas, José Carlos
  • González de la Rosa, Juan José
  • Sierra Fernández, José María
  • Florencias Oliveros, Olivia
There is a prolific literature on the mitigation of cloud-induced photovoltaic fluctuations as a key objective for the effective grid integration of this renewable energy capacity. The meteorological context is of high relevance in such a problem, but it is frequently analysed separately from electrical considerations. However, a few studies have combined both sides of the problem, thus providing valuable references for examining their interdependencies. Therefore, this review focuses on this set of studies to explore the use of meteorological information in the analysis of cloud-induced photovoltaic transients in terms of scales, elements, and objectives under consideration. This examination shows the dependence of the results on the chosen context, allowing for the identification of the strengths and weaknesses of each approach. On this basis, some recommendations for future work are drawn, such as the use of spatiotemporal descriptions of cloud passage, description of the meteorological scenario for an adequate interpretation of results, and necessity of holistic approaches to integrate advances from the meteorological and electrical perspectives of the problem., This work was supported by the Spanish Ministry of Science and Innovation (Grant Number: PID2019-108953RB-C21). The authors would like to thank the Andalusian Government for funding the Research Unit PAIDI-TIC-168.
RODIN. Repositorio de Objetos de Docencia e Investigación de la Universidad de Cádiz
Publicación Artículo científico (JournalArticle)

Methodology for the Surveillance the Voltage Supply in Public Buildings Using the ITIC Curve and Python Programming

  • González de la Rosa, Juan José
  • Sierra Fernández, José María
  • Florencias Oliveros, Olivia
  • Remigio Carmona, Paula
  • Espinosa Gavira, Manuel Jesús
  • Agüera Pérez, Agustín
  • Palomares Salas, José Carlos
  • Fernández Morales, Javier
This paper proposes an easy-to-implement method for detecting and assessing two of the most frequent PQ (Power Quality) problems: voltage sags and swells. These can affect sensitive equipment such as computers, programmable logic controllers, contactors, etc. Therefore, it is of great interest to implement it in any laboratory, not only for protection reasons but also as a safeguard for claims against the supply company. Thanks to the actual context, in which it is possible to manage big volumes of data, connect multiple devices with IoT (Internet of Things), etc., it is feasible and of great interest to monitor the voltage at specific points of the network. This makes it possible to detect voltage sags and swells and diagnose which points are more prone to this type of problems. For the detection of sags and swells, a program written in Python is in charge of crawling all the files in the database and target those RMS values that fall outside the established limits. Compared to LabVIEW, which might have been the most logical alternative, being the acquisition hardware from the same company (National Instruments), Python has a higher computational performance and is also free of charge, unlike LabVIEW. Thanks to the libraries available in Python, it allows a hardware control close to what is possible using LabVIEW. Implemented in MATLAB, the ITIC (Information Technology Industry Council) power acceptability curve reflects the impact of these power quality disturbances in electrical power systems. The results showed that the combined action of Python and MATLAB performed well on a conventional desktop computer., 10 páginas
RODIN. Repositorio de Objetos de Docencia e Investigación de la Universidad de Cádiz
Publicación Artículo científico (JournalArticle)

Improving frequency characterization for power systems using the Allan variance and a GPS-controlled reference: Measurement procedure, test and validation

  • González de la Rosa, Juan José
  • Sierra Fernández, José María
  • Florencias Oliveros, Olivia
  • Espinosa Gavira, Manuel Jesús
  • Palomares Salas, José Carlos
  • Agüera Pérez, Agustín
La interconexión de las redes inteligentes modernas ha dado lugar a varias nuevas perturbaciones de la calidad de la energía (PQ) que afectan a los requisitos de estabilidad de frecuencia en los sistemas eléctricos industriales. La frecuencia, que oscila entre 50 ± 0,1 Hz para las redes interconectadas e incluso dentro del área síncrona europea, fluctúa principalmente debido al control primario. De hecho, debido al desarrollo de recursos distribuidos (por ejemplo, energías renovables), no todas las unidades de generación son accesibles y solo son controlables en unos pocos nodos de la red. Esta variabilidad, incluso entre ubicaciones cercanas, desencadena la necesidad de estrategias de medición específicas, basadas en una referencia absoluta y también concebidas para monitorear las perturbaciones de PQ. Este trabajo propone un método sincronizado con GPS, fácil de implementar, que permite la medición de frecuencia con una precisión mejor que la requerida por la regulación actual para redes interconectadas. Este trabajo explica la metodología de medición, caracterizando la incertidumbre mediante el uso de la norma ISO JCGM 100. Con el propósito de probar y validar, se llevaron a cabo tres experimentos: perturbaciones de laboratorio diseñadas por computadora y activadas por instrumentos, y una comparación con el desempeño de PMU, utilizando señales de la vida real. Los resultados mostraron que estos experimentos ofrecieron un mejor desempeño con una incertidumbre mejorada., The interconnected modern smart grid has resulted in several new power quality (PQ) disturbances that affect the frequency stability requirements in industrial power systems. Ranging between 50 +-0.1 Hz for interconnected networks, and even within the European synchronous area, the frequency fluctuates mainly because of the primary control. In fact, owing to the development of distributed resources (e.g. renewable energies), not all generation units are accessible, and are controllable in a few network nodes. This variability, even between nearby locations, triggers the need for a specific measurement strategies, based on an absolute reference and also conceived for monitoring PQ disturbances. This work proposes an easy-to-implement GPS-traceable method that allows the measurement of frequency with better accuracy than that required by the current regulation for interconnected networks. This work explains the measurement methodology, characterising the uncertainty by using ISO JCGM 100. For the purpose of testing and validation, three experiments were conducted: computer-designed, instrument-triggered lab disturbances, and a comparison vs. PMU performance, using real-life signals. The results showed that these experiments offered better performance with improved uncertainty, Ministerio de Ciencia y Educación, Gobierno de España; Universidad de Cádiz; Junta de Andalucía., 12 páginas en la versión maquetada.
RODIN. Repositorio de Objetos de Docencia e Investigación de la Universidad de Cádiz
Publicación Artículo científico (JournalArticle)

Design and Test of a High-Performance Wireless Sensor Network for Irradiance Monitoring

  • Espinosa Gavira, Manuel Jesús
  • Agüera Pérez, Agustín
  • Sierra Fernández, José María
  • González de la Rosa, Juan José
  • Palomares Salas, José Carlos
  • Florencias Oliveros, Olivia
Cloud-induced photovoltaic variability can affect grid stability and power quality, especially in electricity systems with high penetration levels. The availability of irradiance field forecasts in the scale of seconds and meters is fundamental for an adequate control of photovoltaic systems in order to minimize their impact on distribution networks. Irradiance sensor networks have proved to be efficient tools for supporting these forecasts, but the costs of monitoring systems with the required specifications are economically justified only for large plants and research purposes. This study deals with the design and test of a wireless irradiance sensor network as an adaptable operational solution for photovoltaic systems capable of meeting the measurement specifications necessary for capturing the clouds passage. The network was based on WiFi, comprised 16 pyranometers, and proved to be stable at sampling periods up to 25 ms, providing detailed spatial representations of the irradiance field and its evolution. As a result, the developed network was capable of achieving comparable specifications to research wired irradiance monitoring network with the advantages in costs and flexibility of the wireless technology, thus constituting a valuable tool for supporting nowcasting systems for photovoltaic management and control.
RODIN. Repositorio de Objetos de Docencia e Investigación de la Universidad de Cádiz
Publicación Artículo científico (JournalArticle)

Strategy for Visual Measurement of Power Quality Based on Higher-Order Statistics and Exploratory Big Data Analysis

  • González de la Rosa, Juan José
  • Florencias Oliveros, Olivia
  • Remigio Carmona, Paula
This article proposes a strategy for the visual characterization of power quality in big data analysis contexts, culminating in the development of a visualization tool based on higher-order statistics, which exhibits an efficiency between 83.33% and 100% in detecting 50 Hz synthetic and real-life simple and hybrid events, showing its significant potential for real-world applications marked by non-linear loads and non-Gaussian behaviors and surpassing the detection of traditional tools such as boxplot by up to 50%. Efficient energy management is closely accompanied by an optimum energy data management (EDM). It implies the acquisition, analysis, and interpretation of data to make decisions regarding the best energy usage with subsequent cost reductions. Through a study of indicators, including higher-order statistics, crest factor, SNR and THD, the article establishes nominal values and behavioral patterns, expanding the previous knowledge of these parameters. The indicators are presented as vertices in a radar-type charting tool, providing a multidimensional spatial visualization from individual indices that allows the behavioral pattern associated with each type of disturbance to be characterized combined with a decision tree. In addition, boxplots reflecting data processing are included, which facilitates the comparison and discussion of both visualization instruments: radar chart and boxplot., Spanish Ministry of Science and Education and the State Investigation Agency for funding the research project PID2019-108953RBC21, entitled ‘Strategies for Aggregated Generation of Photo-Voltaic Plants-Energy and Meteorological Data’ (SAGPV-EMOD), and the Andalusian Government for supporting the Research Group PAIDITIC-168, in Computational Instrumentation and Industrial Electronics (ICEI).
RODIN. Repositorio de Objetos de Docencia e Investigación de la Universidad de Cádiz
Publicación Artículo científico (JournalArticle)

Current Status and Future Trends of Power Quality Analysis

  • Remigio Carmona, Paula
  • González de la Rosa, Juan José
  • Florencias Oliveros, Olivia
  • Sierra Fernández, José María
  • Fernández Morales, Javier
  • Espinosa Gavira, Manuel Jesús
  • Agüera Pérez, Agustín
  • Palomares Salas, José Carlos
In this article, a systematic literature review of 153 articles on power quality analysis in PV systems published in the last 20 years is presented. This provides readers with an overview on PQ trends in several fields related to instrumental techniques that are being used in the smart grid to visualize the quality of the energy, establishing a solid literature base from which to start future research. A preliminary appreciation allows us to intuit that higher-order statistics are not implemented in measurement equipment and that traditional instrumentation is still used for the performance of measurement campaigns, not yielding the expected results since the information processed does not come from an electrical network from 20 years ago. Instead, current networks contain numerous coupled load effects; thus, new disturbances are not simple; they are usually complex events, the sum of several types of disturbances. Likewise, depending on the type of installation, the objective of the PQ analysis changes, either by detecting certain events or simply focusing on seeing the state of the network.
RODIN. Repositorio de Objetos de Docencia e Investigación de la Universidad de Cádiz
Publicación Artículo científico (JournalArticle)

Online System for Power Quality Operational Data Management in Frequency Monitoring Using Python and Grafana

  • Sierra Fernández, José María
  • Florencias Oliveros, Olivia
  • Espinosa Gavira, Manuel Jesús
  • González de la Rosa, Juan José
  • Agüera Pérez, Agustín
  • Palomares Salas, José Carlos
This article proposes a measurement solution designed to monitor the instantaneous frequency in power systems. It uses a data acquisition module and a GPS receiver for time stamping and traceability. A Python-based module receives data, computes the frequency, and finally transfers the measurement results to a database. The frequency is calculated with two different methods, which are compared in the article. The stored data is visualized using the Grafana platform, thus demonstrating its potential for comparing scientific data. The system as a whole constitutes an efficient, low-cost solution as a data acquisition system., This research is funded by the Spanish Ministry of Science and Education through the project PID2019-108953RB-C21; has been co-financed by the European Union under the 2014-2020 ERDF Operational Program. Additionally, funding for frequency monitoring comes from the Andalusian-FEDER project FEDER-UCA18-108516 (Intelligent Techniques for visualization and data compression of PQ data in the smart grid).
RODIN. Repositorio de Objetos de Docencia e Investigación de la Universidad de Cádiz
Publicación Artículo científico (JournalArticle)

A Graphical method for PQ assessment: EDA tools using traditional indices and Higher-order Statistics

  • Remigio Carmona, Paula
  • Florencias Oliveros, Olivia
  • González de la Rosa, Juan José
This paper presents a new qualitative method for assessing the power quality (PQ) of electrical systems using both time domain traditional indices and higher-order statistics. The method employs engineering data analysis (EDA) tools to analyse and interpret the PQ data coming from real datasets. Boxplot of each index are considered an essential tool that deserves to be included and studied when an external dataset it is analysed. But this research intends to go a step further, and for this reason a new tool for the spatial visualization of supply quality based on a radar chart is proposed. Each of its vertices constitutes an index, integrating from 3rd to 6 th order statistics with the traditional indicators SNR, SINAD and crest factor. The proposed methodology is applied to the analysis of real available signals and both, boxplot and radarchart, results are compared and commented. Finally, relationships are established between the altered indicators and the type(s) of event found in the signal.